At least 37 records · Page 2

Design and Test of Mixed-flow Impellers II : Experimental Results, Impeller Model MFI-1A

An investigation was conducted to determine the performance characteristics of a mixed-flow impeller which was designed with special emphasis on the reduction or elimination of flow decelerations along wetted surfaces. The performance was investigated over a range of equivalent impeller speeds from 700 to 1600 feet per second and over a range of flow rates from maximum adiabatic temperature-rise efficiency, measured at 1-1/2 impeller diameters in a vaneless diffuser, at the design speed of 1400 feet per second were 4.00 and 0.83, respectively.

THEORY AND EXPERIMENT↗

FORTRAN program for calculating velocities and streamlines on the hub-shroud mid-channel flow surface of an axial- or mixed-flow turbomachine. 1: User's manual

A FORTRAN 4 computer program has been developed that obtains a subsonic or shock-free transonic flow solution on the hub-shroud mid-channel flow surface of a turbomachine. The blade row may be fixed or rotating, and may be twisted and leaned. Flow may be axial or mixed, up to 45 deg from axial. Upstream and downstream flow variables may vary from hub to shroud, and provision is made to correct for loss of stagnation pressure. The results include velocities, streamlines, and flow angles on the flow surface; and approximate blade surface velocities. Subsonic solutions are obtained by a finite-difference stream-function solution. Transonic solutions are obtained by a velocity-gradient method, using information from a finite-difference stream-function solution at a reduced mass flow.

Katsanis, T.↗

Comparison of full-scale engine and subscale model performance of a mixed flow exhaust system for an energy efficient engine (E3) propulsion system

A full scale engine test of the NASA/General Electric Company (GE) Energy Efficient Engine (E3) was conducted to demonstrate the E3 engine concept and evaluate its performance. The test program, performed at the GE outdoor engine test facilities in Peebles, OH, included a detailed evaluation of the total pressure and temperature profiles at the exit of the mixed flow exhaust system to determine its mixing effectiveness. Subscale model tests of the same mixed flow exhaust system had been previously conducted at FluiDyne Engineering Corporation in Minneapolis, Minnesota as part of the GE E3 mixer aerodynamic technology development program. The scale model and full scale engine nozzle exit survey data and the calculated mixing effectiveness are compared and discussed. Results indicate the full scale engine mixing effectiveness to be five percent higher than the scale model as a result of a geometric difference and higher turbulence levels in the engne exhaust flowfield.

Kuchar, A. P.↗

An Aerodynamic Analysis of a Mixed Flow Turbine

The aerodynamic performance of a high-work Mixed Flow Turbine (MFT) is computed and compared with experimental data. A three dimensional (3-D) viscous analysis is applied to the single stage MFT geometry with a relatively long upstream transition duct. Predicted vane surface static pressures and circumferentially averaged spanwise quantities at stator and rotor exits agree favorably with data. Compared to the results of axisymmetric flow analysis from design intent, the 3-D computation agrees much better especially in the endwall regions where throughflow prediction fails to assess the loss mechanism properly. Potential sources of performance loss such as tip leakage and secondary flows are also properly captured by the analysis.

Kim, Chan M.↗

FORTRAN program for calculating velocities and streamlines on the hub-shroud mid-channel flow surface of an axial-or mixed-flow turbomachine. 2: Programmer's manual

A FORTRAN-IV computer program, MERIDL, has been developed that obtains a subsonic or shock-free transonic flow solution on the hub-shroud mid-channel flow surface of a turbomachine. The blade row may be fixed or rotating and may be twisted and leaned. Flow may be axial or mixed, up to 45 deg from axial. Upstream and downstream flow variables can vary from hub to shroud, and provision is made to correct for loss of stagnation pressure. The results include velocities, streamlines, and flow angles on the flow surface and approximate blade surface velocities. Subsonic solutions are obtained by a finite-difference stream-function solution. Transonic solutions are obtained by a velocity-gradient method, using information from a finite-difference stream-function solution at a reduced mass flow.

Katsanis, T.↗

Design and Test of Mixed-flow Impellers III : Design and Experimental Results for Impeller Model MFI-2A and Comparison with Impeller Model MFI-1A

A mixed-flow impeller was designed to give a prescribed blade-surface velocity distribution at mean blade height for a given hub-shroud profile. The blade shape at mean blade height, which was produced by the prescribed velocity distribution, was extended by means of radial lines to form the composite blade shape from hub to shroud. The resulting blade was relatively thick; therefore, it was necessary to retain the inverse blade taper which resulted from extension of the radial lines in order to prevent merging or near merging of the separate blades near the hub. For the first test version of the impeller, designated the MFI-2A, the blade height was arbitrarily made greater than that for the basic impeller (the MFI-2) to allow for viscous effects. At design equivalent speed of 1400 feet per second the peak pressure ratio and maximum adiabatic efficiency were 3.95 and 79 percent, respectively. The adiabatic efficiency of the MFI-2A is four points lower than that for impeller model MFI-1A, but because of the higher slip factor for the MFI-2A, the pressure ratios are approximately equal. The procedures followed in the design of the MFI-1A and MFI-2A were, in general, the same; and, although the prescribed initial condition resulted in geometrical configurations that were quite dissimilar, the resulting performance characteristics compare favorably with designs for which considerable development work has been necessary.

COMPRESSION AND COMPRESSORS↗

Design and performance of family of diffusing scrolls with mixed-flow impeller and vaneless diffuser

A family of diffusing scrolls was designed for use with a mixed-flow impeller and a small-diameter vaneless diffuser. The design theory, intended to maintain a uniform pressure around the scroll inlet, permits determination of the position of scroll cross sections of preassigned area by considering the radial variation in fluid density and the effects of friction along the scroll. Inasmuch as the design method leaves the cross-sectional shape undetermined, the effect of certain variations in scroll shape was investigated by studying scrolls having angles of divergence (of the scroll walls downstream of the entrance section) of 24 degrees, 40 degrees, and 80 degrees. A second 80 degree scroll was of asymmetrical construction and a third was plaster-cast instead of sand-cast. Each scroll was tested as a compressor component at actual impeller tip speeds of 700 to 1300 feet per second from full throttle to surge.

Brown, W Byron↗

Computational Analyses of Propulsion Aeroacoustics for Mixed Flow Nozzle Pylon Installation at Takeoff

A CFD analyses is presented for a set of baseline and noise suppression mixed flow nozzles with and without a pylon installation. The five model configurations are as follows; a baselinecore/fan dual-stream nozzle with an external plug, a chevron mixer nozzle with a peak on the symmetry plane with external plug, both of the above nozzles with an installed bifurcatingpylon and lastly a clocked chevron mixer nozzle such that a trough is aligned with the center of the pylon. The fluid flow is simulated by solving the asymptotically steady, compressible, Reynolds-averaged Navier-Stokes equations using an implicit, up-wind, flux-difference splitting finite volume scheme and standard two equation k-epsilon turbulence model with a linear stress representation. All computations are performed using the multiblock, parallel, structuredcode PAB3D. Results indicate that the clocked chevron with pylon case achieves the most optimal levels of average and peak turbulence kinetic energy and vorticity and therefore is expected to be the quietest of the five configurations tested. Further study is required to refine expressions which are indicative of noise and mate these with rigorous noise prediction models.

Massey, Steven J.↗

Evaluation of the longitudinal stability and control characteristics of a mixed-flow remote-lift STOVL aircraft in transition and hover

An evaluation of the longitudinal stability and control characteristics of a mixed-flow remote-lift (MFRL) STOVL aircraft in the powered-lift portion of the flight envelope is presented. A stabilization and command augmentation system was implemented on the MFRL aircraft to meet the requirements for satisfactory flying qualities. The pitch portion of this control system uses a state-rate feedback implicit model following controller to achieve the desired flying qualities and to suppress the effects of external variations and disturbances in the aircrafts characteristics over the low speed envelope.

Engelland, Shawn A.↗

The effect of prewhirl on the internal aerodynamics and performance of a mixed flow research centrifugal compressor

The internal three-dimensional steady and time-varying flow through the diffusing elements of a centrifugal impeller were investigated using a moderate scale, subsonic, mixed flow research compressor facility. The characteristics of the test facility which permit the measurement of internal flow conditions throughout the entire research compressor and radial diffuser for various operating conditions are described. Results are presented in the form of graphs and charts to cover a range of mass flow rates with inlet guide vane settings varying from minus 15 degrees to plus 45 degrees. The static pressure distributions in the compressor inlet section and on the impeller and exit diffuser vanes, as well as the overall pressure and temperature rise and mass flow rate, were measured and analyzed at each operating point to determine the overall performance as well as the detailed aerodynamics throughout the compressor.

Bryan, William B.↗

Injectant mole-fraction imaging in compressible mixing flows using planar laser-induced iodine fluorescence

A technique is described for imaging the injectant mole-fraction distribution in nonreacting compressible mixing flow fields. Planar fluorescence from iodine, seeded into air, is induced by a broadband argon-ion laser and collected using an intensified charge-injection-device array camera. The technique eliminates the thermodynamic dependence of the iodine fluorescence in the compressible flow field by taking the ratio of two images collected with identical thermodynamic flow conditions but different iodine seeding conditions.

Hartfield, Roy J., Jr.↗

Simulation evaluation of transition and hover flying qualities of a mixed-flow, remote-lift STOVL aircraft

Using a generalized simulation model developed for piloted evaluations of STOVL aircraft, an initial fixed-base simulation of a mixed-flow, remote-lift configuration has been completed. Objectives were to evaluate the integration of the aircraft's flight and propulsion controls to achieve good flying qualities throughout the low-speed flight envelope; to determine control power used during transition, hover, and vertical landing; and to evaluate the transition flight envelope considering the influence of thrust deflection of the remote-lift component. Pilots' evaluations indicated that Level 1 flying qualities could be achieved for deceleration to hover in instrument conditions, for airfield landings, and for recovery to a small ship when attitude and velocity stabilization and command augmentation control modes were provided. Level 2 flying qualities were obtained for these same tasks when only the attitude command mode was used, leaving the pilot to perform the task of thrust management required to control the flight-path and speed in transition and the horizontal and vertical translational velocities in hover. Thrust margins were defined for vertical landing as a function of ground effect and hot-gas ingestion.

Franklin, James A.↗

Selected winglet and mixed flow long duct nacelle development for DC-10 derivative aircraft

The high speed cruise drag effects of the installation of winglets and a wing tip extension and a mixed flow long duct nacelle are investigated. The winglet program utilized a 4.7 percent semispan model in an eight foot transonic wind tunnel. Winglets provided approximately twice the cruise drag reduction of wing tip extensions for about the same increase in bending moment at the wing-fuselage juncture. The long duct nacelle interference drag program utilized the same model, without the winglets, in the 11 foot transonic wind tunnel. The long duct nacelle, installed in the same position as the current short duct nacelle and with the current production symmetric pylon, was a relatively low risk installation. A pylon with an addition small rearward fairing was also tested and showed some drag reduction potential over the current pylon.

Taylor, A. B.↗