Interfacial analysis of tribological systems containing molybdenum disulfide and iron using XPS and CEMS

In the present evaluation of results from studies of the interfacial chemistry and morphology of a buried lubricant-substrate interface, specimens of increasing complexity that culminated with the effects of excess sulfur and defects were characterized by XPS and SEM, as well as conversion-electron Moessbauer spectroscopy (CEMS). In order to simulate sputtered systems, single crystals of MoS2 were damaged with Ar(+) bombardment and coated with Fe. Fe is found to react differently with MoS2 depending on surface treatments, surface defects, annealing treatments, and the presence of excess sulfur. The annealing temperature determines which compounds are formed, as well as the crystal habit and plane at the Fe-MoS2 interface.

Zabinski, J. S.↗

A Comparison of Multivariate and Pre-Processing Methods for Quantitative Laser-Induced Breakdown Spectroscopy of Geologic Samples

The ChemCam instrument selected for the Curiosity rover is capable of remote laser-induced breakdown spectroscopy (LIBS).[1] We used a remote LIBS instrument similar to ChemCam to analyze 197 geologic slab samples and 32 pressed-powder geostandards. The slab samples are well-characterized and have been used to validate the calibration of previous instruments on Mars missions, including CRISM [2], OMEGA [3], the MER Pancam [4], Mini-TES [5], and Moessbauer [6] instruments and the Phoenix SSI [7]. The resulting dataset was used to compare multivariate methods for quantitative LIBS and to determine the effect of grain size on calculations. Three multivariate methods - partial least squares (PLS), multilayer perceptron artificial neural networks (MLP ANNs) and cascade correlation (CC) ANNs - were used to generate models and extract the quantitative composition of unknown samples. PLS can be used to predict one element (PLS1) or multiple elements (PLS2) at a time, as can the neural network methods. Although MLP and CC ANNs were successful in some cases, PLS generally produced the most accurate and precise results.

Anderson, R. B.↗

Temperature-dependent hyperfine interactions in Fe2B.

Moessbauer absorption spectra have been observed for Fe2B from 290 to 1175 K. A change in the electric quadrupole interaction was observed from 460 to 480 K and interpreted as a result of the rotation of the easy axis of magnetization as a function of temperature. The effective magnetic hyperfine field is defined as a function of temperature. A discontinuity in the isomer shift of 0.018 (plus or minus 0.010) mm/sec was found across the ferromagnetic transition.

Murphy, K. A.↗

Moessbauer studies in zinc-manganese ferrites for use in measuring small velocities and accelerations with great precision

Mossbauer spectroscopy was used for a systematic study of the magnetic behavior of manganese and zinc in mixed ferrites. It was observed that Zn2+ has preference to substitute Mn2+ at interstitial sites where the metal ions are tetrahedrally coordinated with four oxygen neighbors. The internal magnetic hyperfine field at the tetrahedral iron site is larger than that at the octahedral site. The relaxation effects were observed to play an important role as the zinc contents were increased, while the spin-correlation time and the magnetic field were observed to decrease in strength. It is concluded that Mossbauer effect data on complex materials, when used in conjunction with other data, can provide useful insight into the origin of the microscopic properties of magnetic materials.

Escue, W. T.↗

Cation distributions on rapidly solidified cobalt ferrite

The cation distributions in two rapidly solidified cobalt ferrites have been determined using Moessbauer spectroscopy at 4.2 K in an 8-T magnetic field. The samples were obtained by gas atomization of a Co0-Fe2O3-P2O5 melt. The degree of cation disorder in both cases was greater than is obtainable by cooling unmelted cobalt ferrite. The more rapidly cooled sample exhibited a smaller departure from the equilibrium cation distribution than did the more slowly cooled sample. This result is explained on the basis of two competing effects of rapid solidification: high cooling rate of the solid, and large undercooling.

De Guire, Mark R.↗

Moessbauer search for ferric oxide phases in lunar materials and simulated lunar materials

Moessbauer studies were carried out on lunar fines and on simulated lunar glasses containing magnetic-like precipitates with the primary objective of determining how much, if any, ferric oxide is present in the lunar soils. Although unambiguous evidence of lunar Fe(3+) phases was not obtained, an upper limit was estimated from different portions of the Moessbauer spectra to be between 0.1 and 0.4 wt.% (as Fe3O4). A smaller than 62 microns fraction of 15021,118 showed 0.5 wt.% ferromagnetic iron at 300 K in as-returned condition. After heating to 650 C in an evacuated, sealed quartz tube for 1400 hours, the same sample exhibited 1 wt.% ferromagnetic iron at room temperature. An accompanying decrease in excess absorption area near zero velocity was noted. Thus, the result of the vacuum heat treatment was to convert fine grained iron to larger particles, apparently without the oxidation effects commonly reported.

Forester, D. W.↗

Effects of the chemical environment on the spectroscopic properties of clays: Applications for Mars

Laboratory studies of Mars soil analogs pose unique problems, since soils interact readily with their environment and exhibit variable characteristics depending on the environment. We have performed a series of experiments focusing on the spectral properties of clays and how they vary as a function of composition and environment, including examination of fundamental as well as overtone absorptions, that occur in the mid- and near-IR, respectively. Smectite clays have been selected in our laboratory experiments as a primary surface analog for Mars because of their compatibility with results of the Viking biology experiments, their stability under current martian conditions, and their compatibility with reflectance spectra of Mars. We prepared a number of monoionic montmorillonites in order to examine the influence of cations on the water molecules in the clay interlayer region. Moessbauer spectra of several montmorillonites with variable amounts of interlayer iron confirm the presence of ferrihydrite.

Bishop, Janice L.↗

Non-Destructive Classification Approaches for Equilbrated Ordinary Chondrites

Classification of meteorites is most effectively carried out by petrographic and mineralogic studies of thin sections, but a rapid and accurate classification technique for the many samples collected in dense collection areas (hot and cold deserts) is of great interest. Oil immersion techniques have been used to classify a large proportion of the US Antarctic meteorite collections since the mid-1980s [1]. This approach has allowed rapid characterization of thousands of samples over time, but nonetheless utilizes a piece of the sample that has been ground to grains or a powder. In order to compare a few non-destructive techniques with the standard approaches, we have characterized a group of chondrites from the Larkman Nunatak region using magnetic susceptibility and Moessbauer spectroscopy.

Righter, K.↗

Properties of Martian Hematite at Meridiani Planum by Simultaneous Fitting of Mars Mossbauer Spectra

Mossbauer spectrometers [1] on the two Mars Exploration Rovers (MERs) have been making measurements of surface rocks and soils since January 2004, recording spectra in 10-K-wide temperature bins ranging from 180 K to 290 K. Initial analyses focused on modeling individual spectra directly as acquired or, to increase statistical quality, as sums of single-rock or soil spectra over temperature or as sums over similar rock or soil type [2, 3]. Recently, we have begun to apply simultaneous fitting procedures [4] to Mars Mossbauer data [5-7]. During simultaneous fitting (simfitting), many spectra are modeled similarly and fit together to a single convergence criterion. A satisfactory simfit with parameter values consistent among all spectra is more likely than many single-spectrum fits of the same data because fitting parameters are shared among multiple spectra in the simfit. Consequently, the number of variable parameters, as well as the correlations among them, is greatly reduced. Here we focus on applications of simfitting to interpret the hematite signature in Moessbauer spectra acquired at Meridiani Planum, results of which were reported in [7]. The Spectra. We simfit two sets of spectra with large hematite content [7]: 1) 60 rock outcrop spectra from Eagle Crater; and 2) 46 spectra of spherule-rich lag deposits (Table 1). Spectra of 10 different targets acquired at several distinct temperatures are included in each simfit set. In the table, each Sol (martian day) represents a different target, NS is the number of spectra for a given sol, and NT is the number of spectra for a given temperature. The spectra are indexed to facilitate definition of parameter relations and constraints. An example spectrum is shown in Figure 1, together with a typical fitting model. Results. We have shown that simultaneous fitting is effective in analyzing a large set of related MER Mossbauer spectra. By using appropriate constraints, we derive target-specific quantities and the temperature dependence of certain parameters. By examining different fitting models, we demonstrate an improved fit for martian hematite modeled with two sextets rather than as a single sextet, and show that outcrop and spherule hematite are distinct. For outcrop, the weaker sextet indicates a Morin transition typical of well-crystallized and chemically pure hematite, while most of the outcrop hematite remains in a weakly ferromagnetic state at all temperatures. For spherule spectra, both sextets are consistent with weakly ferromagnetic hematite with no Morin transition. For both hematites, there is evidence for a range of particle sizes.

Agresti, D. G.↗

Titanium Mass-balance Analysis of Paso Robles Soils: Elemental Gains and Losses as Affected by Acid Alteration Fluids

The Columbia Hills soils have been exposed to aqueous alteration in alkaline [1] as well as acid conditions [2,3]. The Paso Robles class soils are bright soils that possess the highest S concentration of any soil measured on Mars [2]. Ferric-sulfate detection by Moessbauer analysis indicated that acid solutions were involved in forming these soils [4]. These soils are proposed to have formed by alteration of nearby rock by volcanic hydrothermal or fumarolic activity. The Paso Robles soils consist of the original Paso Robles-disturbed-Pasadena (PR-dist), Paso Robles- PasoLight (PR-PL), Arad-Samra, Arad-Hula, Tyrone- Berker Island1 and Tyrone-MountDarwin [2 ,3. ]Chemical characteristics indicate that the PR-dist and PR-PL soils could be derived from acid weathering of local Wishstone rocks while the Samra and Hula soils are likely derived from local Algonquin-Iroquet rock [3]. The Paso Robles soils were exposed to acidic sulfur bearing fluids; however, little else is known about the chemistry of the alteration fluid and its effects on the alteration of the proposed parent materials. The objectives of this work are to conduct titanium normalized mass-balance analysis to1) assess elemental gains and losses from the parent materials in the formation of the Paso Robles soils and 2) utilize this information to indicate the chemical nature of the alteration fluids.

Sutter, Brad↗

Coordination chemistry of iron in glasses contributing to remote-sensed spectra of the moon

Ferric iron and tetrahedrally coordinated Fe(2+) ions are identified using Moessbauer and electronic absorption spectroscopic measurements of synthetic glasses equilibrated at P(O2) less than 10 to the -11 atm, simulating the Luna 24 brown glass and Apollo 15 green glass compositions. The presence of 10-20% ferric iron in these low Ti glasses is a result of the absence of Ti(3+) ions. In the brown glass absorption spectra, tetrahedral Fe(3+) and Fe(2+) ions induce an extension of the oxygen-metal charge transfer band into the visible region further than in the green glass containing predominantly octahedral Fe(2+) and Fe(3+) ions. Whereas the glass one-micron band originates from crystal field transitions in octahedral Fe(2+), the glass two-micron band is now positively correlated with tetrahedral Fe(2+) rather than with Fe(2+) ions in pyroxene M2-like sites in the glass structure. The tetrahedral Fe(2+) do not, however, substitute for Si(4+) in glass network-forming sites, instead occurring as network modifiers in larger tetrahedral interstices. The effect of temperature is to induce a pronounced red-shift of the oxygen-iron charge transfer absorption edge, especially for the brown glass, and to intensify significantly the tetrahedral Fe(2+) crystal field two micron band.

Dyar, M. D.↗

Visible and Near-IR Reflectance Spectra of Smectite Acquired Under Dry Conditions for Interpretation of Martian Surface Mineralogy

Visible and near-IR (VNIR) spectra from the MEx OMEGA and the MRO CRISM hyper-spectral imaging instruments have spectral features associated with the H2O molecule and M OH functional groups (M = Mg, Fe, Al, and Si). Mineralogical assignments of martian spectral features are made on the basis of laboratory VNIR spectra, which were often acquired under ambient (humid) conditions. Smectites like nontronite, saponite, and montmorillionite have interlayer H2O that is exchangeable with their environment, and we have acquired smectite reflectance spectra under dry environmental conditions for interpretation of martian surface mineralogy. We also obtained chemical, Moessbauer (MB), powder X-ray diffraction (XRD), and thermogravimetric (TG) data to understand variations in spectral properties. VNIR spectra were recorded in humid lab air at 25-35C, in a dynamic dry N2 atmosphere (50-150 ppmv H2O) after exposing the smectite samples (5 nontronites, 3 montmorillionites, and 1 saponite) to that atmosphere for up to approximately l000 hr each at 25-35C, approximately 105C, and approximately 215C, and after re-exposure to humid lab air. Heating at 105C and 215C for approximately 1000 hr is taken as a surrogate for geologic time scales at lower temperatures. Upon exposure to dry N2, the position and intensity of spectral features associated with M-OH were relatively insensitive to the dry environment, and the spectral features associated with H2O (e.g., approximately 1.90 micrometers) decreased in intensity and are sometimes not detectable by the end of the 215C heating step. The position and intensity of H2O spectral features recovered upon re-exposure to lab air. XRD data show interlayer collapse for the nontronites and Namontmorillionites, with the interlayer remaining collapsed for the latter after re-exposure to lab air. The interlayer did not collapse for the saponite and Ca-montmorillionite. TG data show that the concentration of H2O derived from structural OH was invariant to the dry N2 treatment for saponite and the montmorillionites, but the nontronites had additional structural OH after treatment. Upon exposure to dry N2, the VNIR spectra also acquired a red slope with decreasing albedo between approximately 0.4 and approximately 2.0 micrometers. The magnitude of the effects covaries with exposure time to dry N2 and heating temperature. Upon re-exposure to lab air, the slope and albedo do not completely recover to pre-exposure values. MB data show that these effects do not result from partial reduction of ferric to ferrous iron, and TG data show they do not result from loss of structural OH. Possible explanations include formation of small clusters of (superparamagnetic) ferric oxide and reduced smectite crystallinity. The difference in spectral properties between spectra acquired in humid lab air and under dry conditions are consequential for interpretation of CRISM and OMEGA spectra. For example, nontronite by itself and not nontronite plus ferrihydrite can account for the red spectral slope in martian spectra where nontronite is indicated by the Fe-OH spectral features.