Search NASA⌕ Search

SEARCH · Search NASA

Results for “MONITOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Paint and Oil Locker SWMU 067 Southern Treatment Area Air Sparge System Year 2 Performance Monitoring and Paint and Oil Locker Northern Area (SWMU 067) and Supply Warehouse #3, SWMU 088 Long-Term Monitoring Kennedy Space Center, Florida

This Year 2 Air Sparge (AS) System Performance Monitoring (PM) Report for Paint and Oil Locker (POL) Solid Waste Management Unit (SWMU) 067 Southern Treatment Area and Long- Term Monitoring (LTM) Report for POL Northern Area (SWMU 067) and Supply Warehouse #3 (SW3) SWMU 088 documents ongoing remedial efforts at the POL and SW3 sites at Kennedy Space Center (KSC), Florida. The overall goal for these sites is to reduce concentrations of groundwater contaminants of concern (COCs), specifically trichloroethene (TCE), cis-1,2-dichloroethene (cDCE), trans-1,2-dichloroethene (tDCE) and vinyl chloride (VC), to below the State of Florida Groundwater Cleanup Target Levels (GCTLs). Remediation and reporting of POL and SW3 have been streamlined over the years due to the proximity of the two sites. The scope for these sites currently includes two main components: (1) LTM at SW3 and the POL Northern Area, where an AS system began operation in May 2009 (with expansion in December 2012) and June 2013, respectively, and subsequently turned off for both sites in March 2018 (NASA, 2019a); and (2) Active AS operations and PM in the POL Southern Treatment Area where an AS system was installed and began operation in 2021. The timeframe for activities covered under this report is from September 2022 to July 2023. Based on Year 2 system operation and PM results, the AS system at POL operated as designed and successfully met the performance objective of reducing VOCs to concentrations that support transition of the site from active remediation to long-term monitoring. The results from the samples collected from performance monitoring wells within the AS system ROI showed a significant decrease in COC concentrations since the baseline sampling event conducted in April 2020. Based on the Year 2 OM&M and monitoring results obtained from the POL Southern Treatment Area, the IM objective to reduce concentrations to below the LTM transition target concentrations for TCE, cDCE, tDCE, and VC has been achieved. LTM sampling events at SW3 were conducted in October 2022 and July 2023. LTM sampling was conducted at the POL Northern Area in October 2022, December 2022, March 2023, and July 2023. Analytical results from October 2022 and July 2023 generally indicate that concentrations of COCs have been stable or decreasing compared to the previous year. TCE remains greater than the NADC in one monitoring well (POL-MW0034S) and greater than the GCTL in one monitoring well (POL-MW0009S). Concentrations of cDCE were greater than the GCTL in one monitoring well (POL-MW0026S), and tDCE was non-detect or less than the GCTL in all monitoring wells sampled. VC was greater than the GCTL in four monitoring wells (MW0024, MW0025, MW0027, and MW0028) at SW3 and one monitoring well (MW0026S) at the POL Northern Area.

remediation↗

Monitoring Aqueous Reprocessing Systems for Detection of Facility Misuse

Traditional approaches to material control and accounting at used nuclear fuel reprocessing facilities relies in large part on laboratory-based destructive assay of periodic samples taken from key stages. These techniques are highly accurate, but limited inspection frequency may limit the size and operation of a reprocessing facility. Online monitoring techniques using inline detectors can be applied to fuel reprocessing systems to improve the situational awareness as the facility is operating to provide additional indicators of the evolving state of the facility between normal inspection periods, potentially alerting regulators to the need for additional inspection. The Multi-Isotope Process (MIP) Monitor combines medium-resolution gamma detectors with statistical data analysis techniques to monitor reprocessing systems for anomalous conditions resulting from process control issues or malfeasance. Gamma spectra collected from the H-Canyon reprocessing facility were modeled using principal component analysis to demonstrate the efficacy of the MIP Monitor for detecting notional diversion scenarios.

safeguards, nuclear fuel reprocessing, gamma spect↗

The Modular Borehole Monitoring Program. A research program to optimize well-based monitoring for geologic carbon sequestration

Understanding the impacts caused by injection of large volumes of CO 2 in the deep subsurface necessitates a comprehensive monitoring strategy. While surface-based and other remote geophysical methods can provide information on the general morphology of a CO 2 plume, verification of the geochemical conditions and validation of the remote sensing data requires measurements from boreholes that penetrate the storage formation. Unfortunately, the high cost of drilling deep wellbores and deploying instrumentation systems constrains the number of dedicated monitoring borings as well as limits the technologies that can be incorporated in a borehole completion. The objective of the Modular Borehole Monitoring (MBM) Program was to develop a robust suite of well-based tools optimized for subsurface monitoring of CO 2 that could meet the needs of a comprehensive well-based monitoring program. It should have enough flexibility to be easily reconfigured for various reservoir geometries and geologies. The MBM Program sought to provide storage operators with a turn-key fully engineered design that incorporated key technologies, function over the decades long time-span necessary for post-closure reservoir monitoring, and meet industry acceptable risk profiles for deep-well installations. While still within the conceptual design phase of the MBM program, the SECARB Anthropogenic Test in Citronelle, Alabama, USA was identified as a deployment site for our engineered monitoring systems. The initial step in designing the Citronelle MBM system was to down-select from the various monitoring tools available to include technologies that we considered essential to any program. Monitoring methods selected included U-tube geochemical sampling, discrete quartz pressure and temperature gauges, an integrated fibre-optic bundle consisting of distributed temperature and heat-pulse sensing, and a sparse string of conventional 3C-geophones. While not originally planned within the initial MBM work scope, the fibre-optic cable was able to also be used for the emergent technology of distributed acoustic sensing. The MBM monitoring string was installed in March, 2012. To date, the Citronelle MBM instruments continue to operate reliably. Results and lessons learned from the Citronelle MBM deployment are addressed along with examples of data being collected.

54 ENVIRONMENTAL SCIENCES↗

Historical Building Stability Monitoring by Means of a Cosmic Ray Tracking System

Cosmic ray radiation is mostly composed, at sea level, by high energy muons, which are highly penetrating particles capable of crossing kilometers of rock. The ubiquitous and steady presence at the Earth's surface and the high penetration capability have motivated the use of cosmic ray radiation also in fields beyond particle physics, from geology, archaeology, speleology to industrial applications and homeland security. In particular, in recent years, the novel technique of muon tomography has been proposed, with the aim of performing non invasive inspection of large non accessible volumes, material atomic number Z and density discrimination, and three dimension image reconstruction of the inspected volume. In the present paper, after a short recall of the physical principles and mathematical formalism on which muon tomography is based, a number of examples of application of the novel technique in industry and homeland security issues is given. Moreover, a new application of cosmic rays detection techniques in the field of civil engineering is proposed. The aim is the monitoring of the stability of large structures, in particular the static monitoring of historical buildings, where conservation constraints are more severe and the time evolution of the deformation phenomena under study may be of the order of months or years. The new technique may be seen, in some way, as the reverse problem of muon tomography. As a significant case study, the monitoring of the wooden vaulted roof of the Palazzo della Loggia in the town of Brescia, in Italy, has been considered. The feasibility as well as the performances and limitations of a monitoring system based on cosmic ray tracking have been studied by Monte Carlo simulation and discussed in comparison with more traditional monitoring systems. (authors)

42 ENGINEERING↗

Development of a Theoretical Monitoring System Design for a HLW Repository Based on the 'MoDeRn Monitoring Workflow' (A Case Study) - 12044

In this paper, a generic German disposal concept in rock salt is used as an example to discuss the design of a repository monitoring system. The approach used is based on a generic structured approach to monitoring - the MoDeRn Monitoring Workflow - which is being developed and tested as part of an on-going European Commission Seventh Framework project. As a first step in the study, the requirements on the monitoring program were identified through consideration of the national context, including regulatory guidelines, host rock properties and waste to be disposed of. These are stated as general monitoring objectives. An analysis of the German safety concept for safe confinement of the radioactive waste allows these general objectives to be converted into specific sub-objectives, and for the sub-objectives to be related to specific monitoring processes and parameters. The safety concept identified the key safety components, each of them having specific associated safety functions. The safety functions can be related to the list of features, events and processes (FEPs) that contains all processes related to the future repository evolution. By screening the FEP list, all processes that potentially can affect the safety functions have been identified. In a next step the parameters that would be affected by the individual processes were determined, leading to a preliminary list of parameters to be monitored. By evaluating available techniques and monitoring equipment, this preliminary list was investigated with respect to its technical feasibility at the intended locations. Prior to final system selection, potential impacts of the monitoring system on safety or other measurements are evaluated. To avoid potential pathways for fluids that may compromise the integrity of a barrier, considerations on the application of wireless data transmission systems and techniques for autonomous, long-term power supply were given. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Long-term monitoring experiences at the HADES underground lab and its relevance for radwaste repository monitoring

In the frame of its radwaste disposal research programme, SCK-CEN started the construction of the HADES underground research facility in 1980. Including several extensions and a comprehensive experimental programme, it has provided a lot of experience on monitoring. Monitoring is performed for many reasons: construction follow-up, field characterisation, investigation of phenomena, and model validations - in which the underground lab offers the opportunity for up-scaling conventional laboratory set-ups. Construction monitoring has allowed to develop and optimise the underground construction techniques in a previously poorly known environment, resulting in a well-mastered application of mechanised methods for gallery construction with minimal damage to the host formation. Access to this formation also allows its characterisation, both geotechnical, geological and geochemical, and the detailed investigation of phenomena such as fracturing and oxidation. Finally, instrumented set-ups allow to test various numerical models by comparing the observations with the predicted behaviour. The specific conditions of the underground laboratory put particular requirements to the sensors. These conditions include the long-term nature of many set-ups - typically several years to decades, the inaccessibility of many sensors after installation, high mechanical and water pressures, and corrosion. Combined with the fact that many sensors are custom made, obtaining and maintaining a fully functional instrumented set-up can be challenging. A lot of experience has therefore been gained which is very valuable when designing the monitoring of radwaste repositories - and it has allowed us to determine the critical success factors for monitoring. Engineers tend to look at this first from a technical viewpoint - and there are many technical aspects indeed that determine the reliability of monitoring. A first one is the combination of different observations ('redundancy') which can be implemented by the use of several sensors, different sensor principles, different (coupled) parameters, and the combination of point measurements with geophysical techniques. Cabling is also a critical issue as it is often considered as the primary enemy of barrier integrity. Minimal cabling techniques, such as distributed fibre optic monitoring and wireless signal transmission, therefore get increasing attention. Also the interpretation of the monitoring data - in particular those that are perceived as 'wrong' or 'unexpected', needs sufficient attention. The long-term experience has however also shown that the design of a monitoring programme must look beyond the technical part. In particular for long-term applications, issues such as data management and record keeping are vital to guarantee success in this. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Wind turbine sensor array for monitoring avian and bat collisions

Assessment of avian and bat collisions with wind turbines is necessary to ensure that the benefits of renewable wind power generation are not outweighed by mortality of protected species. An onboard, integrated multisensor system capable of providing detection of turbine collision events, including taxonomic information, was developed. The conceptual design of a multisensor system including a vibration sensing node, an optics node, and an bioacoustic node with an event–driven trigger architecture was field–tested on utility–scale wind turbines. A pixel density computational model was built to estimate the spatial coverage and target resolution to the optimized configuration for camera placement. Field test results of the vibration node showed that nearly half of the recorded impact events were successfully identified by visual inspection and running short–time Fourier transform on recorded vibration signals. The remaining undetected impact events were masked under background noise due to low impact energy and high background noise of the operating turbine, which result in subsequent low signal–to–noise ratio. Furthermore, our results demonstrate the feasibility of triggering the system through single impact event sensed by vibration sensors.

17 WIND ENERGY↗

Heterogeneous recurrence monitoring and control of nonlinear stochastic processes

Recurrence is one of the most common phenomena in natural and engineering systems. Process monitoring of dynamic transitions in nonlinear and nonstationary systems is more concerned with aperiodic recurrences and recurrence variations. However, little has been done to investigate the heterogeneous recurrence variations and link with the objectives of process monitoring and anomaly detection. Notably, nonlinear recurrence methodologies are based on homogeneous recurrences, which treat all recurrence states in the same way as black dots, and non-recurrence is white in recurrence plots. Heterogeneous recurrences are more concerned about the variations of recurrence states in terms of state properties (e.g., values and relative locations) and the evolving dynamics (e.g., sequential state transitions). This paper presents a novel approach of heterogeneous recurrence analysis that utilizes a new fractal representation to delineate heterogeneous recurrence states in multiple scales, including the recurrences of both single states and multi-state sequences. Further, we developed a new set of heterogeneous recurrence quantifiers that are extracted from fractal representation in the transformed space. To that end, we integrated multivariate statistical control charts with heterogeneous recurrence analysis to simultaneously monitor two or more related quantifiers. Experimental results on nonlinear stochastic processes show that the proposed approach not only captures heterogeneous recurrence patterns in the fractal representation but also effectively monitors the changes in the dynamics of a complex system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Use of the ERD for administrative monitoring of Theta

Monitoring the state of an HPC cluster in a timely and accurate fashion is critical to most system administration functions. For many Cray users, the first step in monitoring is ingestion of log files. Unfortunately, log parsing is an inherently inefficient process, requiring multiple software components to read and write from files on disk. Cray's own utilities use a message bus, the Event Router Daemon (ERD), for a wide variety of purposes. At the Argonne Leadership Computing Facility (ALCF), we have begun to use this message bus for monitoring via a client library written in Go, allowing us to read in structured data directly from Cray's services and, in many instances, bypass log files entirely. In this paper, we will examine the implementation and utilization of this approach on our 4392 node XC40, Theta, as well as the overall benefits and drawbacks to using the ERD for real-time monitoring.

Cray↗

Reference Cross Sections for Charged-particle Monitor Reactions

Evaluated cross sections of beam-monitor reactions are expected to become the de-facto standard for cross-section measurements that are performed over a very broad energy range in accelerators in order to produce particular radionuclides for industrial and medical applications. The requirements for such data need to be addressed in a timely manner, and therefore an IAEA coordinated research project was launched in December 2012 to establish or improve the nuclear data required to characterise charged-particle monitor reactions. An international team was assembled to recommend more accurate cross-section data over a wide range of targets and projectiles, undertaken in conjunction with a limited number of measurements and more extensive evaluations of the decay data of specific radionuclides. Least-square evaluations of monitor-reaction cross sections including uncertainty quantification have been undertaken for charged-particle beams of protons, deuterons, 3 He- and 4 He-particles. In conclusion, recommended beam monitor reaction data with their uncertainties are available at the IAEA-NDS medical portal www-nds.iaea.org/medical/monitor_reactions.html.

43 PARTICLE ACCELERATORS↗

Application of Condition-Based Monitoring Techniques for Remote Monitoring of a Simulated Gas Centrifuge Enrichment Plant

This paper presents research into the adaptation of monitoring techniques from maintainability and reliability (M&R) engineering for remote unattended monitoring of gas centrifuge enrichment plants (GCEPs) for international safeguards. Two categories of techniques are discussed: the sequential probability ratio test (SPRT) for diagnostic monitoring, and sequential Monte Carlo (SMC or, more commonly, particle filtering ) for prognostic monitoring. Development and testing of the application of condition-based monitoring (CBM) techniques was performed on the Oak Ridge Mock Feed and Withdrawal (F&W) facility as a proof of principle. CBM techniques have been extensively developed for M&R assessment of physical processes, such as manufacturing and power plants. These techniques are normally used to locate and diagnose the effects of mechanical degradation of equipment to aid in planning of maintenance and repair cycles. In a safeguards environment, however, the goal is not to identify mechanical deterioration, but to detect and diagnose (and potentially predict) attempts to circumvent normal, declared facility operations, such as through protracted diversion of enriched material. The CBM techniques are first explained from the traditional perspective of maintenance and reliability engineering. The adaptation of CBM techniques to inspector monitoring is then discussed, focusing on the unique challenges of decision-based effects rather than equipment degradation effects. These techniques are then applied to the Oak Ridge Mock F&W facility a water-based physical simulation of a material feed and withdrawal process used at enrichment plants that is used to develop and test online monitoring techniques for fully information-driven safeguards of GCEPs. Advantages and limitations of the CBM approach to online monitoring are discussed, as well as the potential challenges of adapting CBM concepts to safeguards applications.

Condition-Based Monitoring↗

Fourier Transform Infrared Spectroscopy and Multivariate Analysis for Online Monitoring of Dibutyl Phosphate Degradation Product in Tributyl Phosphate/n-Dodecane/Nitric Acid Solvent

In liquid–liquid extraction separation processes, accumulation of organic solvent degradation products is detrimental to the process robustness, and frequent solvent analysis is warranted. Our research explores the feasibility of online monitoring of the organic solvents relevant to used nuclear fuel reprocessing. This paper describes the first phase of developing a system for monitoring the tributyl phosphate (TBP)/n-dodecane solvent commonly used to separate used nuclear fuel. In this investigation, the effect of extraction of nitric acid from aqueous solutions of variable concentrations on the quantification of TBP and its major degradation product dibutylphosphoric acid (HDBP) was assessed. Fourier transform infrared (FTIR) spectroscopy was used to discriminate between HDBP and TBP in the nitric acid-containing TBP/n-dodecane solvent. Multivariate analysis of the spectral data facilitated the development of regression models for HDBP and TBP quantification in real time, enabling online implementation of the monitoring system. The predictive regression models were validated using TBP/n-dodecane solvent samples subjected to high-dose external ?-irradiation. The predictive models were translated to flow conditions using a hollow fiber FTIR probe installed in a centrifugal contactor extraction apparatus, demonstrating the applicability of the FTIR technique coupled with multivariate analysis for the online monitoring of the organic solvent degradation products.

99 GENERAL AND MISCELLANEOUS↗

A real-time applicator position monitoring system for gynecologic intracavitary brachytherapy

Purpose: To develop a real-time applicator position monitoring system (RAPS) for intracavitary brachytherapy using an infrared camera and reflective markers. Methods: 3D image-guided brachytherapy requires high accuracy of applicator localization; however, applicator displacement can happen during patient transfer for imaging and treatment delivery. No continuous applicator position monitoring system is currently available. The RAPS system was developed for real-time applicator position monitoring without additional radiation dose to patients. It includes an infrared camera, reflective markers, an infrared illuminator, and image processing software. After reflective markers are firmly attached to the applicator and the patient body, applicator displacement can be measured by computing the relative change in distance between the markers. The reflective markers are magnetic resonance imaging (MRI) compatible, which is suitable for MRI-guided HDR brachytherapy paradigm. In our prototype, a Microsoft Kinect sensor with a resolution of 640 by 480 pixels is used as an infrared camera. A phantom study was carried out to compare RAPS' measurements with known displacements ranging from −15 to +15 mm. A reproducibility test was also conducted. Results: The RAPS can achieve 4 frames/s using a laptop with Intel{sup ®} Core™2 Duo processor. When the pixel size is 0.95 mm, the difference between RAPS' measurements and known shift values varied from 0 to 0.8 mm with the mean value of 0.1 mm and a standard deviation of 0.44 mm. The system reproducibility was within 0.6 mm after ten reposition trials. Conclusions: This work demonstrates the feasibility of a real-time infrared camera based gynecologic intracavitary brachytherapy applicator monitoring system. Less than 1 mm accuracy is achieved when using an off-the-shelf infrared camera.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pre-commissioning of the wide-dynamic range halo monitor to be installed in the Fermilab MI-8 line

The beam halo can contribute to beam losses in accelerators and is very difficult to measure. With an increase in beam intensity following the PIP-II upgrade at Fermilab, the beam losses are expected to be higher with some coming from beam halo. Therefore, it is important to measure the sources of beam halo to minimize the beam losses. A modified Halo Monitor developed by J-PARC will be installed in Fermilab MI-8 transfer line to measure the beam halo. In this paper, an update on the beam profile monitor fabrication is covered. The updates include the location selection for the Halo Monitor in the MI-8 transfer line, shielding options for instrumentation, initial testing of equipment, and ray tracing simulations for the Offner optics and the targets used in the monitor.

Babacan, Betiay [IIT, Chicago; Fermilab]↗

Application and Certification of Comparative Vacuum Monitoring Sensors for Structural Health Monitoring of 737 Wing Box Fittings

Multi-site fatigue damage, hidden cracks in hard-to-reach locations, disbonded joints, erosion, impact, and corrosion are among the major flaws encountered in today's extensive fleet of aging aircraft and space vehicles. The use of in-situ sensors for real-time health monitoring of aircraft structures are a viable option to overcome inspection impediments stemming from accessibility limitations, complex geometries, and the location and depth of hidden damage. Reliable, structural health monitoring systems can automatically process data, assess structural condition, and signal the need for human intervention. Prevention of unexpected flaw growth and structural failure can be improved if on-board health monitoring systems are used to continuously assess structural integrity. Such systems are able to detect incipient damage before catastrophic failures occurs. Condition-based maintenance practices could be substituted for the current time-based maintenance approach. Other advantages of on-board distributed sensor systems are that they can eliminate costly, and potentially damaging, disassembly, improve sensitivity by producing optimum placement of sensors and decrease maintenance costs by eliminating more time- consuming manual inspections. This report presents a Sandia Labs-aviation industry effort to move SHM into routine use for aircraft maintenance. This program addressed formal SHM technology validation and certification issues so that the full spectrum of concerns, including design, deployment, performance and certification were appropriately considered. The Airworthiness Assurance NDI Validation Center (AANC) at Sandia Labs, in conjunction with Boeing, Delta Air Lines, Structural Monitoring Systems Ltd., Anodyne Electronics Manufacturing Corp. and the Federal Aviation Administration (FAA) carried out a certification program to formally introduce Comparative Vacuum Monitoring (CVM) as a structural health monitoring solution to a specific aircraft wing box application. Validation tasks were designed to address the SHM equipment, the health monitoring task, the resolution required, the sensor interrogation procedures, the conditions under which the monitoring will occur, the potential inspector population, adoption of CVM into an airline maintenance program and the document revisions necessary to allow for routine use of CVM as an alternate means of performing periodic structural inspects. To carry out the validation process, knowledge of aircraft maintenance practices was coupled with an unbiased, independent evaluation. Sandia Labs designed, implemented, and analyzed the results from a focused and statistically-relevant experimental effort to quantify the reliability of the CVM system applied to the Boeing 737 Wing Box fitting application. All factors that affect SHM sensitivity were included in this program: flaw size, shape, orientation and location relative to the sensors, as well as operational and environmental variables. Statistical methods were applied to performance data to derive Probability of Detection (POD) values for CVM sensors in a manner that agrees with current nondestructive inspection (NDI) validation requirements and also is acceptable to both the aviation industry and regulatory bodies. This report presents the use of several different statistical methods, some of them adapted from NDI performance assessments and some proposed to address the unique nature of damage detection via SHM systems, and discusses how they can converge to produce a confident quantification of SHM performance An important element in developing SHM validation processes is a clear understanding of the regulatory measures needed to adopt SHM solutions along with the knowledge of the structural and maintenance characteristics that may impact the operational performance of an SHM system. This report describes the major elements of an SHM validation approach and differentiates the SHM elements from those found in NDI validation. The activities conducted in this program demonstrated the feasibility of routine SHM usage in general and CVM in particular for the application selected. They also helped establish an optimum OEM-airline-regulator process and determined how to safely adopt SHM solutions. This formal SHM validation will allow aircraft manufacturers and airlines to confidently make informed decisions about the proper utilization of CVM technology. It will also streamline the regulatory actions and formal certification measures needed to assure the safe application of SHM solutions.

42 ENGINEERING↗

Using Geophysical Technologies Deployed in Inexpensive Monitoring Wells to Monitor the Evolution of a CO 2 Plume: Potential Benefits and R&D Needs

This report demonstrates the potential benefits of an R&D program designed to substantially decrease the cost of drilling monitoring wells. The study determines the costs of monitoring a commercial-scale CO 2 storage project's CO 2 plume using a vertical seismic profile (VSP) array. The VSP array consists of permanent surface orbital vibrator (SOV) seismic sources and distributed acoustic sensing (DAS) fiber optic cable receivers permanently installed in shallow monitoring wells. Several scenarios are assessed varying the costs of drilling monitoring wells for DAS to evaluate the potential benefits of an R&D program to lower well costs. The monitoring costs of VSP are compared against those of 4-D seismic surveys which deploy temporary seismic sources and receivers. If the cost of monitoring wells can be lowered about 50%, VSP monitoring is a more attractive cost option than 4-D seismic for CO 2 plume monitoring, warranting future R&D efforts to lower these costs.

58 GEOSCIENCES↗

Task 1. Monitoring real time materials degradation. NRC extended In-situ and real-time Monitoring

The overall objective of this project was to perform a scoping study to identify, in concert with the nuclear industry, those sensors and techniques that have the most promising commercial viability and fill a critical inspection or monitoring need. Candidates to be considered include sensors to monitor real-time material degradation, characterize residual stress, monitor and inspect component fabrication, assess radionuclide and associated chemical species concentrations in ground water and soil, characterize fuel properties, and monitor severe accident conditions. Under Task 1—Monitoring Real-Time Materials Degradation—scoping studies were conducted to assess the feasibility of potential inspection and monitoring technologies (i.e., a combination of sensors, advanced signal processing techniques, and data analysis methods) that could be utilized in LWR and/or advanced reactor applications for continuous monitoring of degradation in-situ. The goal was to identify those techniques that appear to be the most promising, i.e., those that are closest to being both technically and commercially viable and that the nuclear industry is most likely to pursue. Current limitations and associated issues that must be overcome before commercial application of certain techniques have also been addressed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

I35W collapse, rebuild, and structural health monitoring - challenges associated with structural health monitoring of bridge systems

During evening rush hour traffic on August 1, 2007, the major interstate highway bridge carrying I35W over the Mississippi River in Minneapolis catastrophically failed, tragically taking the lives of thirteen people and injuring many more. The steel truss bridge, constructed in 1967, was undergoing deck reconstruction during the collapse, and was estimated to carry more than 140,000 vehicles daily. This tragedy generated great interest in employment of structural health monitoring systems. The I35W St. Anthony Falls Bridge, a post-tensioned concrete box bridge constructed to replace the collapsed steel truss bridge, contains over 500 instruments to monitor the structural behavior. Numerical models of the bridge are being developed and calibrated to the collected data obtained from truck load tests and thermal effects. The data obtained over the first few years of monitoring are being correlated with the calibrated models and used to develop the baseline bridge behavior. This information is being used to develop a system to monitor and interpret the long-term behavior of the bridge. This paper describes the instrumentation, preliminary results from the data and model calibration, the plan for developing long-term monitoring capabilities, and the challenges associated with structural health monitoring of bridge systems. In addition, opportunities and directions for future research required to fully realize the objectives of structural health monitoring are described.

42 ENGINEERING↗