Search NASA⌕ Search

SEARCH · Search NASA

Results for “MRM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Update to NASA's Clinical Practice Guideline for Renal Stone Surveillance in U.S. Astronauts

BACKGROUND: For the past 9 years all NASA astronauts received specialized renal ultrasound screening for precursors to renal stones, our so called “mineralized renal material” (MRM), to reduce the possibility of sending a person to space with a renal stone that could cause morbidity and threaten mission objectives. A recent analysis of this data shows no increased incidence of clinical or sub-clinical renal stones associated with spaceflight; thus, our clinical practice guideline has been updated. OVERVIEW: Astronauts previously received a renal ultrasound screening at selection and at every annual recertification exam. In total, 73 individuals have been scanned and 282 total studies have been performed as of April 2023.This data shows no observed statistical change seen in MRM burden pre-to postflight, therefore a reduction in the frequency of the screening exams is appropriate. DISCUSSION: Data presented in this panel have shown no direct correlation between spaceflight and development of MRM or renal stones in astronaut kidneys out to at least 6 months of spaceflight. The MRM burden does not seem to change appreciably over time and so far, has no demonstrated correlation to external factors. Therefore, we find it appropriate, in lieu of yearly exams, to reduce the frequency of screening to: initial selection, first annual exam after selection, and pre/postflight. This balances the screening frequency of our astronauts, against the potential for unnecessary medical procedures, while still serving the purpose of risk reduction.

D Reyes↗

Prognostic Value of Molecular Subtypes, Ki67 Expression and Impact of Postmastectomy Radiation Therapy in Breast Cancer Patients With Negative Lymph Nodes After Mastectomy

Purpose: To determine whether Ki67 expression and breast cancer subtypes could predict locoregional recurrence (LRR) and influence the postmastectomy radiotherapy (PMRT) decision in breast cancer (BC) patients with pathologic negative lymph nodes (pN0) after modified radical mastectomy (MRM). Methods and Materials: A total of 699 BC patients with pN0 status after MRM, treated between 2001 and 2008, were identified from a prospective database in a single institution. Tumors were classified by intrinsic molecular subtype as luminal A or B, HER2+, and triple-negative (TN) using estrogen, progesterone, and HER2 receptors. Multivariate Cox analysis was used to determine the risk of LRR associated with intrinsic subtypes and Ki67 expression, adjusting for known prognostic factors. Results: At a median follow-up of 56 months, 17 patients developed LRR. Five-year LRR-free survival and overall survival in the entire population were 97%, and 94.7%, respectively, with no difference between the PMRT (n=191) and no-PMRT (n=508) subgroups. No constructed subtype was associated with an increased risk of LRR. Ki67 >20% was the only independent prognostic factor associated with increased LRR (hazard ratio, 4.18; 95% CI, 1.11-15.77; P<.0215). However, PMRT was not associated with better locoregional control in patients with proliferative tumors. Conclusions: Ki67 expression but not molecular subtypes are predictors of locoregional recurrence in breast cancer patients with negative lymph nodes after MRM. The benefit of adjuvant RT in patients with proliferative tumors should be further investigated in prospective studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accelerated kinetic Monte Carlo: A case study; vacancy and dumbbell interstitial diffusion traps in concentrated solid solution alloys

Vacancy and self-interstitial atomic diffusion coefficients in concentrated solid solution alloys can have a non-monotonic concentration dependence. Here, the kinetics of monovacancies and $\langle$100$\rangle$ dumbbell interstitials in Ni–Fe alloys are assessed using lattice kinetic Monte Carlo (kMC). The non-monotonicity is associated with superbasins, which impels using accelerated kMC methods. Detailed implementation prescriptions for first passage time analysis kMC (FPTA-kMC), mean rate method kMC (MRM-kMC), and accelerated superbasin kMC (AS-kMC) are given. The accelerated methods are benchmarked in the context of diffusion coefficient calculations. The benchmarks indicate that MRM-kMC underestimates diffusion coefficients, while AS-kMC overestimates them. In this application, MRM-kMC and AS-kMC are computationally more efficient than the more accurate FPTA-kMC. Our calculations indicate that composition dependence of migration energies is at the origin of the vacancy’s non-monotonic behavior. In contrast, the difference between formation energies of Ni–Ni, Ni–Fe, and Fe–Fe dumbbell interstitials is at the origin of their non-monotonic diffusion behavior. Additionally, the migration barrier crossover composition—based on the situation where Ni or Fe atom jumps have lower energy barrier than the other one—is introduced. KMC simulations indicate that the interplay between composition dependent crossover of migration energy and geometrical site percolation explains the non-monotonic concentration-dependence of atomic diffusion coefficients.

36 MATERIALS SCIENCE↗

Advances in targeted proteomics and applications to biomedical research

Targeted proteomics technique has emerged as a powerful protein quantification tool in systems biology, biomedical research, and increasing for clinical applications. The most widely used targeted proteomics approach, selected reaction monitoring (SRM), also known as multiple reaction monitoring (MRM), can be used for quantification of cellular signaling networks and preclinical verification of candidate protein biomarkers. As an extension to our previous review on advances in SRM sensitivity (Shi et al., Proteomics , 12, 1074–1092, 2012) herein we review recent advances in the method and technology for further enhancing SRM sensitivity (from 2012 to present), and highlighting its broad biomedical applications in human bodily fluids, tissue and cell lines. Furthermore, we also review two recently introduced targeted proteomics approaches, parallel reaction monitoring (PRM) and data‐independent acquisition (DIA) with targeted data extraction on fast scanning high‐resolution accurate‐mass (HR/AM) instruments. Such HR/AM targeted quantification with monitoring all target product ions addresses SRM limitations effectively in specificity and multiplexing; whereas when compared to SRM, PRM and DIA are still in the infancy with a limited number of applications. Thus, for HR/AM targeted quantification we focus our discussion on method development, data processing and analysis, and its advantages and limitations in targeted proteomics. Finally, general perspectives on the potential of achieving both high sensitivity and high sample throughput for large‐scale quantification of hundreds of target proteins are discussed.

Shi, Tujin↗

Postmastectomy Chest Wall Radiation to a Temporary Tissue Expander or Permanent Breast Implant-Is There a Difference in Complication Rates?

Purpose: The purpose of this study was to evaluate the likelihood of complications and cosmetic results among breast cancer patients who underwent modified radical mastectomy (MRM) and breast reconstruction followed by radiation therapy (RT) to either a temporary tissue expander (TTE) or permanent breast implant (PI). Methods and Materials: Records were reviewed of 74 patients with breast cancer who underwent MRM followed by breast reconstruction and RT. Reconstruction consisted of a TTE usually followed by exchange to a PI. RT was delivered to the TTE in 62 patients and to the PI in 12 patients. Dose to the reconstructed chest wall was 50 Gy. Median follow-up was 48 months. The primary end point was the incidence of complications involving the reconstruction. Results: There was no significant difference in the rate of major complications in the PI group (0%) vs. 4.8% in the TTE group. No patients lost the reconstruction in the PI group. Three patients lost the reconstruction in the TTE group. There were excellent/good cosmetic scores in 90% of the TTE group and 80% of the PI group (p = 0.22). On multivariate regression models, the type of reconstruction irradiated had no statistically significant impact on complication rates. Conclusions: Patients treated with breast reconstruction and RT can experience low rates of major complications. We demonstrate no significant difference in the overall rate of major or minor complications between the TTE and PI groups. Postmastectomy RT to either the TTE or the PI should be considered as acceptable treatment options in all eligible patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dummy Run of Quality Assurance Program in a Phase 3 Randomized Trial Investigating the Role of Internal Mammary Lymph Node Irradiation in Breast Cancer Patients: Korean Radiation Oncology Group 08-06 Study

Purpose: The Korean Radiation Oncology Group (KROG) 08-06 study protocol allowed radiation therapy (RT) technique to include or exclude breast cancer patients from receiving radiation therapy to the internal mammary lymph node (IMN). The purpose of this study was to assess dosimetric differences between the 2 groups and potential influence on clinical outcome by a dummy run procedure. Methods and Materials: All participating institutions were asked to produce RT plans without irradiation (Arm 1) and with irradiation to the IMN (Arm 2) for 1 breast-conservation treatment case (breast-conserving surgery [BCS]) and 1 mastectomy case (modified radical mastectomy [MRM]) whose computed tomography images were provided. We assessed interinstitutional variations in IMN delineation and evaluated the dose-volume histograms of the IMN and normal organs. A reference IMN was delineated by an expert panel group based on the study guidelines. Also, we analyzed the potential influence of actual dose variation observed in this study on patient survival. Results: Although physicians intended to exclude the IMN within the RT field, the data showed almost 59.0% of the prescribed dose was delivered to the IMN in Arm 1. However, the mean doses covering the IMN in Arm 1 and Arm 2 were significantly different for both cases (P<.001). Due to the probability of overdose in Arm 1, the estimated gain in 7-year disease-free survival rate would be reduced from 10% to 7.9% for BCS cases and 7.1% for MRM cases. The radiation doses to the ipsilateral lung, heart, and coronary artery were lower in Arm 1 than in Arm 2. Conclusions: Although this dummy run study indicated that a substantial dose was delivered to the IMN, even in the nonirradiation group, the dose differences between the 2 groups were statistically significant. However, this dosimetric profile should be studied further with actual patient samples and be taken into consideration when analyzing clinical outcomes according to IMN irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postmastectomy Radiation Therapy Is Associated With Improved Survival in Node-Positive Male Breast Cancer: A Population Analysis

Purpose: Because of its rarity, there are no randomized trials investigating postmastectomy radiation therapy (PMRT) in male breast cancer. This study retrospectively examines the impact of PMRT in male breast cancer patients in the National Cancer Institute's Surveillance, Epidemiology, and End Results (SEER) database. Methods and Materials: The SEER database 8.3.2 was queried for men ages 20+ with a diagnosis of localized or regional nonmetastatic invasive ductal/lobular carcinoma from 1998 to 2013. Included patients were treated by modified radical mastectomy (MRM), with or without adjuvant external beam radiation. Univariate and multivariate analyses evaluated predictors for PMRT use after MRM. Kaplan-Meier overall survival (OS) curves of the entire cohort and a case-matched cohort were calculated and compared by the log-rank test. Cox regression was used for multivariate survival analyses. Results: A total of 1933 patients were included in the unmatched cohort. There was no difference in 5-year OS between those who received PMRT and those who did not (78% vs 77%, respectively, P=.371); however, in the case-matched analysis, PMRT was associated with improved OS at 5 years (83% vs 54%, P<.001). On subset analysis of the unmatched cohort, PMRT was associated with improved OS in men with 1 to 3 positive nodes (5-year OS 79% vs 72% P=.05) and those with 4+ positive nodes (5-year OS 73% vs 53% P<.001). On multivariate analysis of the unmatched cohort, independent predictors for improved OS were use of PMRT: HR=0.551 (0.412-0.737) and estrogen receptor–positive disease: HR=0.577 (0.339-0.983). Predictors for a survival detriment were higher grade 3/4: HR=1.825 (1.105-3.015), larger tumor T2: HR=1.783 (1.357-2.342), T3/T4: HR=2.683 (1.809-3.978), higher N-stage: N1 HR=1.574 (1.184-2.091), N2/N3: HR=2.328 (1.684-3.218), black race: HR=1.689 (1.222-2.336), and older age 81+: HR=4.164 (1.497-11.582). Conclusions: There may be a survival benefit with the addition of PMRT for male breast cancer with node-positive disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Site specific modification of the human plasma proteome by methylglyoxal

Increasing evidence identifies dicarbonyl stress from reactive glucose metabolites, such as methylglyoxal (MG), as a major pathogenic link between hyperglycemia and complications of diabetes. MG covalently modifies arginine residues, yet the site specificity of this modification has not been thoroughly investigated. Sites of MG adduction in the plasma proteome were identified using LC–MS/MS analysis in vitro following incubation of plasma proteins with MG. Treatment of plasma proteins with MG yielded 14 putative MG hotspots from five plasma proteins (albumin [nine hotspots], serotransferrin, haptoglobin [2 hotspots], hemopexin, and Ig lambda-2 chain C regions). The search results revealed two versions of MG-arginine modification, dihydroxyimidazolidine (R + 72) and hydroimidazolone (R + 54) adducts. One of the sites identified was R257 in human serum albumin, which is a critical residue located in drug binding site I. This site was validated as a target for MG modification by a fluorescent probe displacement assay, which revealed significant drug dissociation at 300 μM MG from a prodan–HSA complex (75 μM). Moreover, twelve human plasma samples (six male, six female, with two type 2 diabetic subjects from both genders) were analyzed using multiple reaction monitoring (MRM) tandem mass spectrometry and revealed the presence of the MG-modified albumin R257 peptide. These data provide insights into the nature of the site-specificity of MG modification of arginine, which may be useful for therapeutic treatments that aim to prevent MG-mediated adverse responses in patients. - Highlights: • Methylglyoxal (MG) selectively modifies arginine sites in human plasma proteome. • Dihydroxyimidazolidine and hydroimidazolone adducts on serum albumin identified • MG modification on albumin R257 associated with loss of drug site I binding capacity • MRM-tandem mass spectrometry enables sensitive detection of albumin MG-R257. • Site-specific MG modification may represent a useful monitor of effective therapy of T2DM.

60 APPLIED LIFE SCIENCES↗

Single Quadrupole Multiple Fragment Ion Monitoring Quantitative Mass Spectrometry

Single quadrupole mass spectrometry (MS) with enhanced in-source multiple fragment ion monitoring was designed to perform high sensitivity quantitative mass analyses. Enhanced in-source fragmentation amplifies fragmentation from traditional soft electrospray ionization producing fragment ions that have been found to be identical to those generated in tandem MS. We have combined enhanced in-source fragmentation data with criteria established by the European Union Commission Directive 2002/657/EC for electron ionization single quadrupole quantitative analysis to perform quantitative analyses. These experiments were performed on multiple types of complex samples that included a mixture of 50 standards, as well as cell and plasma extracts. The dynamic range for these quantitative analyses was comparable to triple quadrupole multiple reaction monitoring (MRM) analyses at up to 5 orders of magnitude with the cell and plasma extracts showing similar matrix effects across both platforms. Amino acid and fatty acid measurements performed from certified NIST 1950 plasma with isotopically labeled standards demonstrated accuracy in the range of 91–110% for the amino acids, 76–129% for the fatty acids, and good precision (coefficient of variation <10%). To enhance specificity, a newly developed correlated ion monitoring algorithm was designed to facilitate these analyses. This algorithm autonomously processes, aligns, filters, and compiles multiple ions within one chromatogram enabling both precursor and in-source fragment ions to be correlated within a single chromatogram, also enabling the detection of coeluting species based on precursor and fragment ion ratios. Single quadrupole instrumentation can provide MRM level quantitative performance by monitoring/correlating precursor and fragment ions facilitating high sensitivity analysis on existing single quadrupole instrumentation that are generally inexpensive, easy to operate, and technically less complex.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Metagenome-Guided Proteomic Quantification of Reductive Dehalogenases in the Dehalococcoides mccartyi -Containing Consortium SDC-9

At groundwater sites contaminated with chlorinated ethenes, fermentable substrates are often added to promote reductive dehalogenation by indigenous or augmented microorganisms. Contemporary bioremediation performance monitoring relies on nucleic acid biomarkers of key organohalide-respiring bacteria, such as Dehalococcoides mccartyi (Dhc). In this work, metagenome sequencing of the commercial, Dhc-containing consortium, SDC-9, identified 12 reductive dehalogenase (RDase) genes, including pceA (two copies), vcrA, and tceA, and allowed for specific detection and quantification of RDase peptides using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Shotgun (i.e., untargeted) proteomics applied to the SDC-9 consortium grown with tetrachloroethene (PCE) and lactate identified 143 RDase peptides, and 36 distinct peptides that covered greater than 99% of the protein-coding sequences of the PceA, TceA, and VcrA RDases. Quantification of RDase peptides using multiple reaction monitoring (MRM) assays with 13 C-/ 15 N-labeled peptides determined 1.8 × 10 3 TceA and 1.2 × 10 2 VcrA RDase molecules per Dhc cell. Ultimately, the MRM mass spectrometry approach allowed for sensitive detection and accurate quantification of relevant Dhc RDases and has potential utility in bioremediation monitoring regimes.

59 BASIC BIOLOGICAL SCIENCES↗

Rapidly Assessing the Quality of Targeted Proteomics Experiments through Monitoring Stable-Isotope Labeled Standards

Selected reaction monitoring (SRM), also known as multiple reaction monitoring (MRM), is a data acquisition technique used in targeted analysis of molecules, including targeted proteomic studies. It exploits the unique capability of triple-quadrupole (QQQ) mass spectrometers to monitor the predefined precursor and fragment ion pairs of specific molecules of interest throughout a liquid chromatography (LC) elution profile. Compared to shotgun proteomics, targeted proteomics using SRM has high selectivity, high sensitivity, and a wide linear dynamic range,(1-3) which makes it especially useful in the accurate and reproducible quantification of low-abundance proteins in highly complex biological samples. SRM has been widely used in the fields of biomarker discovery,(4-7) analysis of protein post-translational modifications(8) and characterization of biological protein networks.(4,9) In the recent years, multiple technical advances have greatly improved the throughput of SRM analyses, allowing for the quantification of hundreds of peptides in a single analysis.(6,7,10) For example, a single 800-plex SRM assay (e.g., 400 unlabeled and heavy-labeled peptide pairs and 2400 transitions with retention time scheduling) using ultrahigh-performance liquid chromatography (UHPLC) has been developed to quantify proteins in plasma.(11) Advanced labeling techniques utilizing in vitro proteome-assisted MRM for protein absolute quantification (iMPAQT) demonstrated the capability of SRM in genome-wide protein quantification of over 18?000 human proteins.(12) Moreover, the scan speed of QQQ instrumentation has been greatly improved in recent releases of commercial instrumentation. The newly developed TSQ Altis (released in 2017) can scan more than 600 transitions per second, which is 6 times more than a traditional QQQ scan speed of 100 transitions per second. The breadth of measurement enabled by these technological improvements to QQQ mass spectrometry has increased the feasibility and popularity of large scale targeted proteomics studies,(13) a major application of which will be in clinical studies in which up to hundreds of protein candidates need to be quantified in hundreds of clinical specimens.(14) Quantitative accuracy is a primary motivating factor for utilizing a targeted proteomics protocol. The precise and reproducible absolute quantification produced by SRM assays is essential to many clinical and laboratory experiments.(15,16) Because the abundance of an endogenous peptide is calculated from the measurement of the spiked-in reference standard, it is essential to assess the data quality of these references.(17) In early applications of targeted proteomics, when instrument speed greatly limited the number of transitions that could be monitored, much of this quality assessment was done manually. However, recent improvements in instrument performance and experimental design have enabled a dramatic increase in the number of target peptides and associated SRM transitions, which makes manual quality assessment an untenable and laborious task. A variety of computational tools assist in SRM experiment design and data analysis. The first task in creating an SRM experiment is the choice of proteins and representative peptides to monitor. Achieving a reliable protein abundance requires appropriately choosing peptides that have a strong signal and are free from interferences in the biological matrix. Numerous computational tools exist to facilitate assay design by identifying peptides and refining SRM transitions.(18-21) To help share these assays and eliminate time spent designing the same transitions at multiple institutions, community portals have begun to host well-designed and vetted assays.(22-24) Analyzing the experimental data requires significant computational effort to align files across replicates and experimental conditions, pick peaks and produce quantitative values, normalize data and perform statistical tests, etc.(25-27)

Gibbons, Bryson C.↗

Reliability enhancement of Navier-Stokes codes through convergence enhancement

Reduction of total computing time required by an iterative algorithm for solving Navier-Stokes equations is an important aspect of making the existing and future analysis codes more cost effective. Several attempts have been made to accelerate the convergence of an explicit Runge-Kutta time-stepping algorithm. These acceleration methods are based on local time stepping, implicit residual smoothing, enthalpy damping, and multigrid techniques. Also, an extrapolation procedure based on the power method and the Minimal Residual Method (MRM) were applied to the Jameson's multigrid algorithm. The MRM uses same values of optimal weights for the corrections to every equation in a system and has not been shown to accelerate the scheme without multigriding. Our Distributed Minimal Residual (DMR) method based on our General Nonlinear Minimal Residual (GNLMR) method allows each component of the solution vector in a system of equations to have its own convergence speed. The DMR method was found capable of reducing the computation time by 10-75 percent depending on the test case and grid used. Recently, we have developed and tested a new method termed Sensitivity Based DMR or SBMR method that is easier to implement in different codes and is even more robust and computationally efficient than our DMR method.

Choi, K.-Y.↗

Four Generations of Maintenance Resource Management Programs in the United States: An Analysis of the Past, Present, and Future

This paper analyzes four generations of Maintenance Resource Management (MRM) programs implemented by aviation maintenance organizations in the United States. Data collected from over ten years of survey research and field observations are used for this analysis; they are presented in a case-study format. The first three generations of MRM programs were episodic efforts to increase safety through teamwork, focus group discussions, and awareness courses, respectively. Now, the fourth generation programs, characterized by a commitment to long-term communication and behavioral changes in maintenance, are set to build on those earlier generations, toward a culture of mutual trust between mechanics, their managers, and regulators.

Taylor, James C.↗

Science Requirements for a Space Flight Experiment Entitled Critical Viscosity of Xenon

We propose to measure in low gravity the viscosity of xenon close to its critical point. The accuracy will be sufficient to eliminate uncertainties currently associated with the analysis of l-g experiments. The measurements will provide the first direct observation of the predicted power-law divergence of viscosity in a pure fluid. The measurements will also strengthen Zeno's test of mode coupling theory by greatly increasing the reliability of the extrapolation of viscosity to low reduced temperatures. Our scientific objectives are described in more detail in one of the attached reports. The low-gravity experiment will be the final stage of a program whose completed ground-based stages are: (1) theoretical studies by one of the principal investigators (MRM) and coworkers, (2) critical viscosity measurements of binary liquid mixtures, (3) critical viscosity measurements of pure fluids in l-g, and development of a suitable vibration-insensitive viscometer. Our technical approach is described in the draft Science Requirements Document. One of us (MRM) has reviewed opportunities for critical phenomena research in low gravity. Both of us were co-principal investigators in the Thermal Equilibration Experiment in the Critical Point Facility, flown on IML-1 in 1992. From this experience, and from the technical maturity of our ground-based work, we believe our critical point viscometer is ready for development as a flight experiment.

Berg, Robert F.↗

Extraction of Oxygen from the Martian Atmosphere

A mechanical process was designed for direct extraction of molecular oxygen from the martian atmosphere based on liquefaction of the majority component, CO2, followed by separation of the lower-boiling components. The atmospheric gases are compressed from about 0.007 bar to 13 bar and then cooled to liquefy most of the CO2. The uncondensed gases are further compressed to 30 bar or more, and then cooled again to recover water as ice and to remove much of the remaining CO2. The final gaseous products consisting mostly of nitrogen, oxygen, and carbon monoxide are liquefied and purified by cryogenic distillation. The liquefied CO2 is expanded back to the low-pressure atmosphere with the addition of heat to recover a majority of the compression energy and to produce the needed mechanical work. Energy for the process is needed primarily as heat to drive the CO2-based expansion power system. When properly configured, the extraction process can be a net producer of electricity. The conceptual design, termed 'MARRS' for Mars Atmosphere Resource Recovery System, was based on the NASA/JSC Mars Reference Mission (MRM) requirement for oxygen. This mission requires both liquid oxygen for propellant, and gaseous oxygen as a component of air for the mission crew. With single redundancy both for propellant and crew air, the oxygen requirement for the MRM is estimated at 5.8 kg/hr. The process thermal power needed is about 120 kW, which can be provided at 300-500 C. A lower-cost nuclear reactor made largely of stainless steel could serve as the heat source. The chief development needed for MARRS is an efficient atmospheric compression technology, all other steps being derived from conventional chemical engineering separations. The conceptual design describes an exceptionally low-mass compression system that can be made from ultra-lightweight and deployable structures. This system adapts to the rapidly changing martian environment to supply the atmospheric resource to MARRS at constant conditions.

England, C.↗

Detection of Asymptomatic Renal Calcifications in Astronauts Using a Novel Ultrasound Protocol

Ultrasound (US) specifically looking for asymptomatic renal calcifications that may be renal stones is typically not done in the terrestrial setting. Standard abdominal US without a renal focus may discover incidental, mineralized renal material (MRM); however punctate solid areas of MRM is less than 3 mm are usually considered subclinical. Detecting these early calcifications before they become symptomatic renal stones is critical to prevent adverse medical and mission outcomes during spaceflight.

Garcia, Kathleen↗

Beyond the Western front: Targeted proteomics and organelle abundance profiling

The application of westerns or immunoblotting techniques for assessing the composition, dynamics, and purity of protein extracts from plant material has become common practice. While the approach is reproducible, can be readily applied and is generally considered robust, the field of plant science suffers from a lack of antibody variety against plant proteins. The development of approaches that employ mass spectrometry to enable both relative and absolute quantification of many hundreds of proteins in a single sample from a single analysis provides a mechanism to overcome the expensive impediment in having to develop antibodies in plant science. Here, we consider it an opportune moment to consider and better develop the adoption of multiple reaction monitoring (MRM)-based analyses in plant biochemistry.

59 BASIC BIOLOGICAL SCIENCES↗

Mass Spectrometry-based Assay for High Throughput and High Sensitivity Biomarker Verification

Searching for disease specific biomarkers has become a major undertaking in the biomedical research field as the effective diagnosis, prognosis and treatment of many complex human diseases are largely determined by the availability and the quality of the biomarkers. A successful biomarker as an indicator to a specific biological or pathological process is usually selected from a large group of candidates by a strict verification and validation process. To be clinically useful, the validated biomarkers must be detectable and quantifiable by the selected testing techniques in their related tissues or body fluids. Due to its easy accessibility, protein biomarkers would ideally be identified in blood plasma or serum. However, most disease related protein biomarkers in blood exist at very low concentrations (<1ng/mL) and are “masked” by many none significant species at orders of magnitude higher concentrations. The extreme requirements of measurement sensitivity, dynamic range and specificity make the method development extremely challenging. The current clinical protein biomarker measurement primarily relies on antibody based immunoassays, such as ELISA. Although the technique is sensitive and highly specific, the development of high quality protein antibody is both expensive and time consuming. The limited capability of assay multiplexing also makes the measurement an extremely low throughput one rendering it impractical when hundreds to thousands potential biomarkers need to be quantitatively measured across multiple samples. Mass spectrometry (MS)-based assays have recently shown to be a viable alternative for high throughput and quantitative candidate protein biomarker verification. Among them, the triple quadrupole MS based assay is the most promising one. When it is coupled with liquid chromatography (LC) separation and electrospray ionization (ESI) source, a triple quadrupole mass spectrometer operating in a special selected reaction monitoring (SRM) mode, also known as multiple reaction monitoring (MRM), is capable of quantitatively measuring hundreds of candidate protein biomarkers from a relevant clinical sample in a single analysis. The specificity, reproducibility and sensitivity could be as good as ELISA. Furthermore, SRM MS can also quantify protein isoforms and post-translational modifications, for which traditional antibody-based immunoassays often don’t exist.

Environmental Molecular Sciences Laboratory↗