At least 37 records · Page 2

Physics-Based Limiter Redesign and Bit Performance Analysis at The Geysers

As part of a U.S. DOE Geothermal Technologies Office funding opportunity, Geysers Power Company, LLC (GPC), an indirect subsidiary of Calpine Corporation, partnered with Sandia National Labs, EGI at the University of Utah, and Texas A&M University to demonstrate increased drilling performance at The Geysers Geothermal Field. The performance target in the drilling demonstrations is at least a 25% improvement in rates of penetration, with increased footage on bottom for each bit coupled with increased bit life and time drilling. The project leverages advances in oil and gas drilling technologies including PDC bits, along with the physics-based limiter redesign techniques championed in drilling demonstrations conducted at the Utah FORGE geothermal site. The planned drilling demonstrations are being conducted as part of an existing drilling campaign intended to enhance reservoir utilization. The wells are typically drilled to the top of the reservoir with mud and then air-drilled to total depth (TD) through fractured zones at temperatures ≥ 450°F. A major goal of the project is to assess the effectiveness of implementing mechanical specific energy (MSE) and drilling dysfunction diagnosis and remediation in these challenging environments, as well as alternate rock reduction technologies. The first demonstration well has been completed, with 15 PDC bit runs in the 17.5”, 12.25” and 8.5” sections. Initial analysis shows ROP gains in all three sections, especially in the 17.5” and 12.25” sections, compared with conventional roller cone bit runs in the demonstration well and offset wells. However, in the 8.5” hole, wear and damage to the PDC bits resulted in relatively short bit runs. Analysis is underway to take advantage of the positive results and remediate the challenges. This paper provides updates on drilling activities conducted since the Phase 1 demonstration well at GDC-36 which was drilled from November 2023-January 2024. Additional analysis of the bit performance has been conducted. Furthermore, in subsequent wells drilled by GPC, PDC bits have been used extensively, building on the gains realized at GDC-36. GPC has continued to work with bit vendors to identify designs that last longer in the harsh, air-drilled 8.5” portions of the wells. Planning for the Phase 2 demonstration at Prati-44 is ongoing.

15 GEOTHERMAL ENERGY↗

Material Goals Towards Equity Along the STEM and LGBTQIA+ Spectra

Materials Science and Engineering (MSE) is an exciting interdisciplinary field that promises to secure an understanding of materials underpin technologies that enable modern life. We often champion the properties of the materials we study, we must remember that these advances are afforded by the people ‘behind’ the research and applications. This warrants us to consider the impact of our academic & industrial research climate, and whether there is equal access/support to participate. As such, this article focusses on disparities for members of the LGBTQIA+ (lesbian, gay, bisexual, transgender, queer, intersex, asexual, and more) community. Furthermore, we hope to support actions that create a more equitable community, where there is a sense of inclusion and belonging and power shared amongst LGBTQIA+ and non-LGBTQIA+ identifying individuals.

99 GENERAL AND MISCELLANEOUS↗

Final Report - Energy Reduction and Advanced Water Removal via Membrane Solvent Extraction Technology

3M and Archer Daniels Midland (ADM) collaborated with the U.S. Department of Energy (DOE) to develop and demonstrate a novel membrane solvent extraction (MSE) process that can substantially reduce energy and water consumption in ethanol production, and accelerate the fermentation process. A cross-flow membrane module was developed, using porous membrane manufactured by 3M. A pilot process was developed that integrates fermentation, MSE and vacuum distillation. Extended experiments of 48-72 hours each were conducted to develop the process, verify its performance and begin establishing commercial viability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The multi-spectral line-polarization MSE system on Alcator C-Mod

A multi-spectral line-polarization motional Stark effect (MSE-MSLP) diagnostic has been developed for the Alcator C-Mod tokamak wherein the Stokes vector is measured in multiple wavelength bands simultaneously on the same sightline to enable better polarized background subtraction. A ten-sightline, four wavelength MSE-MSLP detector system was designed, constructed, and qualified. This system consists of a high-throughput polychromator for each sightline designed to provide large étendue and precise spectral filtering in a cost-effective manner. Each polychromator utilizes four narrow bandpass interference filters and four custom large diameter avalanche photodiode detectors. Two filters collect light to the red and blue of the MSE emission spectrum while the remaining two filters collect the beam pi and sigma emission generated at the same viewing volume. The filter wavelengths are temperature tuned using custom ovens in an automated manner. All system functions are remote controllable and the system can be easily retrofitted to existing single-wavelength line-polarization MSE systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Energetics for Aeronautical Applications. Volume II

NASA has identified water vapor emission into the upper atmosphere from commercial transport aircraft, particularly as it relates to the formation of persistent contrails, as a potential environmental problem. Since 1999, MSE has been working with NASA-LaRC to investigate the concept of a transport-size emissionless aircraft fueled with liquid hydrogen combined with other possible breakthrough technologies. The goal of the project is to significantly advance air transportation in the next decade and beyond. The power and propulsion (P/P) system currently being studied would be based on hydrogen fuel cells (HFCs) powering electric motors, which drive fans for propulsion. The liquid water reaction product is retained onboard the aircraft until a flight mission is completed. As of now, NASA-LaRC and MSE have identified P/P system components that, according to the high-level analysis conducted to date, are light enough to make the emissionless aircraft concept feasible. Calculated maximum aircraft ranges (within a maximum weight constraint) and other performance predictions are included in this report. This report also includes current information on advanced energy-related technologies, which are still being researched, as well as breakthrough physics concepts that may be applicable for advanced energetics and aerospace propulsion in the future.

Alexander, David S.↗

Improved spectral analysis for the motional Stark effect diagnostic

The magnetic pitch angle and the magnitude from reversed field pinch plasmas in the Madison symmetric torus (MST) have been routinely obtained from fully resolved motional Stark effect (MSE) spectrum analyses. Recently, the spectrum fit procedure has been improved by initializing and constraining the fit parameters based on the MSE model in the atomic data and analysis structure. A collisional-radiative model with level populations nlm-resolved up to n= 4 and a simple Born approximation for ion-impact cross sections is used for this analysis. Measurement uncertainty is quantified by making MSE measurements with multiple views of a single spatial location, ranging 5%-15% for typical MST operation conditions. A multi-view fit improves the goodness of fit of MSE spectral features and background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrumentation for a multichord motional Stark effect diagnostic in KSTAR

The motional Stark effect (MSE) diagnostic is used to measure the radial magnetic pitch angle profile in neutral beam heated plasmas. This information is used to calculate the safety factor, q, with magnetic equilibrium reconstruction codes such as EFIT. The MSE diagnostic is important during active shaping of the q profile to optimize confinement and stability, and it has become a key diagnostic in high performance tokamaks. A multichord photo-elastic modulator (PEM) based MSE system is being developed for a real-time plasma current profile control in Korea Superconducting Tokamak Advanced Research (KSTAR). The PEM-based approach is a standard method that measures the polarization direction of a single Stark line with narrow tunable bandpass filters. A tangential view of the heating beam provides good spatial resolution of 1–3 cm, which provides an opportunity to install 25 spatial channels spanning the major radius from 1.74 m to 2.84 m. Application of real-time control is a long-term technical goal after commissioning the diagnostic in KSTAR, which is expected in 2015. In this paper, we describe the design of this newly-constructed multichord MSE diagnostic in KSTAR.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using motional Stark splitting of D$_α$ emission to constrain MHD equilibrium analysis in DIII-D plasmas

Herein we report tests of an alternate technique for constraining MHD equilibrium analysis in tokamak plasmas using internal magnetic field measurements based on |$B$| measurements from the motional Stark splitting of D$_α$ spectral lines emitted by a neutral heating beam (MSE-LS). We compare results using MSE-LS with those of the standard equilibrium analysis technique based on line polarization of the D$_α$ emission (MSE-LP). An alternative to MSE-LP is needed in future devices such as ITER where MSE-LP will be difficult due to a plasma-induced coating of the first optical element. The tests utilized data from 10 DIII-D shots with 7 MSE-LS and 14 MSE-LP views covering a range of radii along the outer midplane of the plasma. Seven MSE-LS measurements can contribute significantly to the equilibrium reconstruction of pressure and q profiles using both synthetic and experimental DIII-D MSE-LS data. For example, 7 MSE-LS plus seven MSE-LP measurements give a fit quality that is as good as the same cases with 14 MSE-LP measurements. Analyzing synthetic data for 14 MSE-LS measurements shows significant improvement in fitting quality over the case with 7 MSE-LS locations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of the Motional Stark Effect Diagnostic Using Laser-Induced Fluorescence (Final Technical Report)

This report describes the development of the motional Stark Effect diagnostic with laser induced fluorescence (MSE-LIF). The MSE concept relies upon observation of the Balmer-alpha (n=3 to n=2) emission from a neutral hydrogen beam traversing a plasma. As a beam at high velocity, $\vec{v}$, passes through the magnetic field in the plasma, $\vec{B}$, it experiences in its reference frame a Lorentz electric field, $\vec{E} = \vec{v} × \vec{B}$. This electric field causes the spectral emission to be split and polarized as described by the Stark effect. The transition is separated into a set of lines in which the line spacing is linearly proportional to the electric field magnitude, and the line polarization is dependent on the electric field direction. Traditionally, MSE has used polarimetry to determine the polarization angle of the light, and related that to the magnetic field pitch angle in the plasma. The MSE diagnostic was developed under high magnetic field (> 1 T) conditions, and the lower fields of recent high-beta experiments such as NSTX posed challenges to the technique. At low magnetic fields Doppler broadening effects mask the Stark effect. With the use of a narrow band laser to pump the Balmer-alpha transition many of the broadening effects are eliminated or mitigated so that MSE measurements at very low magnetic fields can be obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Disruption Prediction and Avoidance in High Beta Long Pulse KSTAR Plasmas

DoE Grant DE-SC0016409 (Disruption Prediction and Avoidance in High Beta Long Pulse KSTAR Plasmas) supported a collaboration among Columbia University, the Princeton Plasma Physics Laboratory (PPPL), and the Plasma Science and Fusion Center (PSFC) at MIT to conduct research on the KSTAR tokamak at the National Fusion Research Institute (NFRI) in Korea to improve predictive capability for disruptions in tokamaks. This initiative included upgrades to kinetic diagnostics at KSTAR whose measurements form the basis for the disruption prediction models. The major thrust of the PPPL and PSFC work was implementing a capability at KSTAR to allow partially-polarized background light seen by the KSTAR Motional Stark Effect (MSE) diagnostic to be compensated by ‘wavelength interpolation’ rather than the traditional ‘beam modulation’ technique. This objective was completed on time and on budget, and the MSE Background Polychromator is currently functioning at KSTAR. Primary responsibility for maintaining and operating the MSE-BP was transferred to Nova Photonics, Inc. in 2019.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectral Effects on Fast Wave Core Heating and Current Drive

Recent results obtained with high harmonic fast wave (HHFW) heating and current drive (CD) on NSTX strongly support the hypothesis that the onset of perpendicular fast wave propagation right at or very near the launcher is a primary cause for a reduction in core heating efficiency at long wavelengths that is also observed in ICRF heating experiments in numerous tokamaks. A dramatic increase in core heating efficiency was first achieved in NSTX L-mode helium majority plasmas when the onset for perpendicular wave propagation was moved away from the antenna and nearby vessel structures. Efficient core heating in deuterium majority L mode and H mode discharges, in which the edge density is typically higher than in comparable helium majority plasmas, was then accomplished by reducing the edge density in front of the launcher with lithium conditioning and avoiding operational points prone to instabilities. These results indicate that careful tailoring of the edge density profiles in ITER should be considered to limit rf power losses to the antenna and plasma facing materials. Finally, in plasmas with reduced rf power losses in the edge regions, the first direct measurements of high harmonic fast wave current drive were obtained with the motional Stark effect (MSE) diagnostic. The location and radial dependence of HHFW CD measured by MSE are in reasonable agreement with predictions from both full wave and ray tracing simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development and validation of a critical gradient energetic particle driven Alfven eigenmode transport model for DIII-D tilted neutral beam experiments

Recent experiments with the DIII-D tilted neutral beam injection (NBI) varying the beam energetic particle (EP) source profiles have provided strong evidence that unstable Alfven eigenmodes (AE) drive stiff EP transport at a critical EP density gradient. Here the critical gradient is identified by the local AE growth rate being equal to the local ITG/TEM growth rate at the same low toroidal mode number. The growth rates are taken from the gyrokinetic code GYRO. Simulation show that the slowing down beam-like EP distribution has a slightly lower critical gradient than the Maxwellian. The ALPHA EP density transport code, used to validate the model, combines the low-n stiff EP critical density gradient AE mid-core transport with the energy independent high-n ITG/TEM density transport model controling the central core EP density profile. For the on-axis NBI heated DIII-D shot 146102, while the net loss to the edge is small, about half the birth fast ions are transported from the central core r/a < 0.5 and the central density is about half the slowing down density. Lastly, these results are in good agreement with experimental fast ion pressure profiles inferred from MSE constrained EFIT equilibria.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Robotic calibration of the motional Stark effect diagnostic on Alcator C-Mod

The capability to calibrate diagnostics, such as the Motional Stark Effect (MSE) diagnostic, without using plasma or beam-into-gas discharges will become increasingly important on next step fusion facilities due to machine availability and operational constraints. A robotic calibration system consisting of a motorized three-axis positioning system and a polarization light source capable of generating arbitrary polarization states with a linear polarization angle accuracy of <0.05° has been constructed and has been used to calibrate the MSE diagnostic deployed on Alcator C-Mod. The polarization response of the complex diagnostic is shown to be fully captured using a Fourier expansion of the detector signals in terms of even harmonics of the input polarization angle. The system's high precision robotic control of position and orientation allow it to be used also to calibrate the geometry of the instrument's view. Combined with careful measurements of the narrow bandpass spectral filters, this system fully calibrates the diagnostic without any plasma discharges. The system's high repeatability, flexibility, and speed has been exploited to quantify several systematics in the MSE diagnostic response, providing a more complete understanding of the diagnostic performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of DIII-D plasmas for Future Measurements of the Driven Current Density in the DIII-D High Field Side Lower Hybrid Experiment

High field side (HFS) lower hybrid current drive (LHCD) is a promising method for efficiently driving off-axis current in steady state tokamak power plants. The first test of this technology is underway at the DIII-D tokamak. The initial physics goal is to measure the LH-driven current density profile in order to validate the ray-tracing/Fokker-Plank codes GENRAY/CQL3D and gain confidence in their ability to predict LH deposition in future DIII-D experiments and fusion power plants. DIII-D’s motional Stark effect (MSE) diagnostic will be used to constrain the magnetic equilibrium reconstructions. From these reconstructions, the ohmic, bootstrap, and driven non-inductive components of the current density profile can be extracted. Several recent DIII-D plasmas have been identified in which GENRAY/CQL3D predict measurable amounts of current with only 100 kW of coupled power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements with magnetic field in the National Spherical Torus Experiment using the motional Stark effect with laser induced fluorescence diagnostic

The motional Stark effect with laser-induced fluorescence diagnostic (MSE-LIF) has been installed and tested on the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Lab. The MSE-LIF diagnostic will be capable of measuring radially resolved profiles of magnetic field magnitude or pitch angle in NSTX plasmas. The system includes a diagnostic neutral hydrogen beam and a laser which excites the n = 2 to n = 3 transition. A viewing system has been implemented which will support up to 38 channels from the plasma edge to past the magnetic axis. First measurements of MSE-LIF signals in the presence of small applied magnetic fields in neutral gas are reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimizing Geothermal Drilling: Oil and Gas Technology Transfer

There is a significant amount of financial risk associated with geothermal drilling. This study of drilling operations seeks opportunities to improve upon current practices and technologies. The scope of this study included analyzing 21 geothermal wells and 21 oil and gas wells. The goal was to determine a 'Perfect Well' using historical data to compare the best oil and gas well to the best geothermal well. Unfortunately, limitations encountered in the study included missing data (bit records, mud information, etc.) and poor data collection practices An online software database was used to format drilling data to IADC coded daily drilling reports and generate figures for analysis. Six major issues have been found in geothermal drilling operations. These problems include lost circulation, rig/ equipment selection, cementing, penetration rate, drilling program, and time management. As a result of these issues, geothermal drilling averaged 56.4 days longer than drilling comparable oil and gas wells in the wells in this study. Roughly $13.9 million was spent on non-productive time in the 21 geothermal wells, compared with only $1.3 million in the oil and gas wells, assuming a cost of $50,000 per day. Comparable events such as drilling the same sized hole, tripping in/out, cementing, and running the same size casing took substantially less time in the oil and gas wells. Geothermal wells were drilled using older and/or less advanced technology to depths less than 10,000 feet, while oil and gas wells reached 12,500 feet faster with purpose built rigs. A new approach is now underway that will optimize drilling programs throughout the drilling industry using Mechanical Specific Energy (MSE) as a tool to realize efficient drilling processes. Potential improvements for current geothermal operations are: the use of electronic records, real time services, and official glossary terms to describe rig operations, and advanced drilling rigs/technology.

15 GEOTHERMAL ENERGY↗

Measurements of the internal magnetic field using the B-Stark motional Stark effect diagnostic on DIII-D (inivited)

Results are presented from the B-Stark diagnostic installed on the DIII-D tokamak. This diagnostic provides measurements of the magnitude and direction of the internal magnetic field. The B-Stark system is a version of a motional Stark effect (MSE) diagnostic based on the relative line intensities and spacing of the Stark split D{sub {alpha}} emission from injected neutral beams. This technique may have advantages over MSE polarimetry based diagnostics in future devices, such as the ITER. The B-Stark diagnostic technique and calibration procedures are discussed. The system is shown to provide accurate measurements of B{sub {theta}}/B{sub T} and |B| over a range of plasma conditions. Measurements have been made with toroidal fields in the range of 1.2-2.1 T, plasma currents in the range 0.5-2.0 MA, densities between 1.7 and 9.0x10{sup 19} m{sup -3}, and neutral beam voltages between 50 and 81 keV. The viewing direction and polarization dependent transmission properties of the collection optics are found using an in situ beam into gas calibration. These results are compared to values found from plasma equilibrium reconstructions and the MSE polarimetry system on DIII-D.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial operation of a newly developed multichord motional Stark effect diagnostic in KSTAR

A photo-elastic modulator based 25-chord motional Stark effect (MSE) diagnostic has been successfully developed and commissioned in Korea Superconducting Tokamak Advanced Research. The diagnostic measures the radial magnetic pitch angle profile of the Stark splitting of a D-alpha line at 656.1 nm by the electric field associated with the neutral deuterium heating beam. A tangential view of the neutral beam provides a good spatial resolution of 1–3 cm for covering the major radius from 1.74 m to 2.28 m, and the time resolution is achieved at 10 ms. An in-vessel calibration before the vacuum closing as well as an in situ calibration during the tokamak operation was performed by means of specially designed polarized lighting sources. In this work, we present the final design of the installed MSE diagnostic and the first results of the commissioning.