Search NASA⌕ Search

SEARCH · Search NASA

Results for “Magnetic Field Measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Advancing Reel-to-Reel Inspection Techniques for Long HTS Conductors: Comparison and Innovations

The continuous advancement of high-temperature superconductor (HTS) technologies has greatly accelerated the development and deployment of HTS applications. Among the critical tools supporting these advancements are reel-to-reel (R2R) critical current (I c ) measurement techniques, which are extensively used by both manufacturers and end users to characterize long-length REBCO conductors. These techniques play a vital role in quality assurance and quality control (QA/QC), ensuring the reliability and performance of HTS conductors and applications throughout the production cycle. We have developed a range of in-house devices for R2R measurements at the University of Houston and Princeton Plasma Physics Laboratory. These include one-dimensional (1D) scan using a magnetic circuit (MC) and two-dimensional (2D) magnetic field mapping systems based on scanning probe array microscope (SPAM) or scanning probe microscopy (SPM). Each technique offers distinct advantages: the MC system provides ultra-fast scanning speeds, ideal for rapid inspection in large-scale industrial production; the high-resolution SPM delivers detailed insights for conductor research and development; and the SPAM, with its simpler mechanical setup, can be upgraded for higher field and lower temperature conditions with a balanced 2D resolution. Here we compared the magnetization and detection capabilities of these techniques through experiments on rare-earth barium copper oxide (REBCO) coated conductor samples, with data analysis supported by numerical simulations. Based on our comprehensive comparative studies, we propose enhancements for each measurement system and provide guidelines for selecting the optimal technique combinations to meet specific application requirements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of Magnetic Field using Doppler-Free Saturation Spectroscopy (DFSS) in C-2W FRC Plasma

The Cooperative Research and Development Agreement (CRADA) between Oak Ridge National Laboratory (ORNL) and TAE Technologies (TAE) focused on implementing an existing mobile Doppler-free saturation spectroscopy (DFSS) diagnostic to determine the direction of the equilibrium magnetic field within TAE’s C-2W field-reversed configuration (FRC) fusion device. Non-perturbative measurements of magnetic fields in the core of FRCs can provide critical information needed to constrain equilibrium models and for the continued advancement of the fusion research program at TAE. DFSS is a well-established, laser-based absorption spectroscopy technique used to suppress inhomogeneous (Doppler) broadening and reveal the Zeeman fine structure of the target emission lines. The collaboration involved the use of ORNL’s recently constructed mobile DFSS diagnostic. The DFSS diagnostic was shipped and installed on C- 2W in February 2023. TAE’s expertise was used to design and construct the mechanic support structures required to mount the optical hardware on C-2W. Additionally TAE provide critical input to minimize the noise imposed on the DFSS signal by vibrations of the mechanic support structure during operations. DFSS data was obtained for over 500 C-2W shots and will continue until the expiration of this CRADA on September 30 th 2023. Over the course of this work, significant progress was made to maximize the signal to noise (SNR) ratio. Analysis of recently acquired data is on-going, however, initial indications are highly suggestive that a DFSS signal above background has been successfully acquired in C-2W.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magneto-optical measurement of magnetic field and electrical current on a short pulse high energy pulsed power accelerator

We describe a direct magneto-optical approach to measuring the magnetic field driven by a narrow pulse width (<10 ns), 20 kA electrical current flow in the transmission line of a high energy pulsed power accelerator. The magnetic field and electrical current are among the most important operating parameters in a pulsed power accelerator and are critical to understanding the properties of the radiation output. However, accurately measuring these fields and electrical currents using conventional pulsed power diagnostics is difficult due to the strength of ionizing radiation and electromagnetic interference. Our approach uses a fiber coupled laser beam with a rare earth element sensing crystal sensor that is highly resistant to electromagnetic interference and does not require external calibration. Here, we focus on device theory, operating parameters, results from an experiment on a high energy pulsed power accelerator, and comparison to a conventional electrical current shunt sensor.

42 ENGINEERING↗

Concept Design of Active Shielding for Dynamic Wireless Charging of Light-duty EV

Dynamic wireless charging of electric vehicles is a flexible and state of the art charging technology with the potential capability of enabling fully automated in-motion charging. With charging power increasing to more than 100 kW for light duty vehicles, electromagnetic field (EMF) emission becomes a critical challenge. Due to the high costs of ferrite materials, this paper proposes an active shielding solution with multiple canceling coils installed on the ground side to supplement ferrite passive shielding to ensure electromagnetic safety. Two canceling coils are designed on two sides of the ground side coil. The canceling coils are small in size and 180 degree opposite in phase to the ground coil. Simulation and modeling shows that the canceling coils can reduce EMF emission from 37.2 µT to 18.2 µT at 0.8 m during 100 kW operation with only 2.5% of ground side current flowing in the canceling coils. These results have been preliminarily verified by inductance measurements and magnetic field measurement at 1.1 m distance without canceling coils. By further increasing the canceling coils’ currents to 4%, EMF emission can also be mitigated at 200 kW, although the canceling coils’ shape, position, and phase angle can be further optimized to improve the three-dimensional field distribution.

25 ENERGY STORAGE↗

Measurements of Magnetic Field Penetration of Materials for Superconducting Radiofrequency Cavities

Superconducting Radio Frequency (SRF) cavities used in particle accelerators are typically formed from or coated with superconducting materials. Currently high purity niobium is the material of choice for SRF cavities which have been optimized to operate near their theoretical field limits. This brings about the need for significant R&D efforts to develop next generation superconducting materials which could outperform Nb and keep up with the demands of new accelerator facilities. To achieve high quality factors and accelerating gradients, the cavity material should be able to remain in the superconducting Meissner state under high RF magnetic field without penetration of quantized magnetic vortices through the cavity wall. Therefore, the magnetic field at which vortices penetrate in a supercon- ductor is one of the key parameters of merit of SRF cavities. Techniques to measure the onset of magnetic field penetration on thin film samples need to be developed to mitigate the issues with the conventional magnetometry measurements which are strongly influenced by the film orientation and shape and edge effects. The applied magnetic field is also needed to be parallel to the one side of the superconductor to resemble the magnetic field profile at the surface of the SRF cavities operating at fundamental accelerating mode. In this work we report the development of an experimental setup called Magnetic Field Penetration (MFP) magnetometer to measure the field of full flux penetration through bulk, thin films and multilayered superconductors. Our system combines a small superconducting solenoid which can generate the magnetic field up to 500 mT at the sample surface and three Hall probes to detect the full flux penetration through the planner superconductor with 2 inch diameter. This setup was used to study alternative materials which could potentially outperform niobium, as well as SIS multilayer coatings on niobium.

Senevirathne, Iresha↗

Measurements of Magnetic Field Penetration in Superconducting Materials for SRF Cavities

Superconducting radiofrequency (SRF) cavities used in particle accelerators operate in the Meissner state. To achieve high accelerating gradients, the cavity material should stay in the Meissner state under high RF magnetic field without penetration of vortices through the cavity wall. The field onset of flux penetration into a superconductor is an important parameter of merit of alternative superconducting materials other than Nb which can enhance the performance of SRF cavities. There is a need for a simple and efficient technique to measure the onset of field penetration into a superconductor directly. We have developed a Hall probe experimental setup for the measurement of the flux penetration field through a superconducting sample placed under a small superconducting solenoid magnet which can generate magnetic fields up to 500 mT. The system has been calibrated and used to measure different bulk and thin film superconducting materials. This system can also be used to study SIS multilayer coatings that have been proposed to enhance the vortex penetration field in Nb cavities.

Senevirathne, I. H.↗

3D modeling of deep borehole electromagnetic measurements with energized casing source for fracture mapping at the Utah Frontier Observatory for Research in Geothermal Energy

Here, we present a 3D numerical modelling analysis evaluating the deployment of a borehole electromagnetic measurement tool to detect and image a stimulated zone at the Utah Frontier Observatory for Research in Geothermal Energy geothermal site. As the depth to the geothermal reservoir is several kilometres and the size of the stimulated zone is limited to several 100 m, surface-based controlled-source electromagnetic measurements lack the sensitivity for detecting changes in electrical resistivity caused by the stimulation. To overcome the limitation, the study evaluates the feasibility of using a three-component borehole magnetic receiver system at the Frontier Observatory for Research in Geothermal Energy site. To provide sufficient currents inside and around the enhanced geothermal reservoir, we use an injection well as an energized casing source. To efficiently simulate energizing the injection well in a realistic 3D resistivity model, we introduce a novel modelling workflow that leverages the strengths of both 3D cylindrical-mesh-based electromagnetic modelling code and 3D tetrahedral-mesh-based electromagnetic modelling code. The former is particularly well-suited for modelling hollow cylindrical objects like casings, whereas the latter excels at representing more complex 3D geological structures. In this workflow, our initial step involves computing current densities along a vertical steel-cased well using a 3D cylindrical electromagnetic modelling code. Subsequently, we distribute a series of equivalent current sources along the well's trajectory within a complex 3D resistivity model. We then discretize this model using a tetrahedral mesh and simulate the borehole electromagnetic responses excited by the casing source using a 3D finite-element electromagnetic code. This multi-step approach enables us to simulate 3D casing source electromagnetic responses within a complex 3D resistivity model, without the need for explicit discretization of the well using an excessive number of fine cells. We discuss the applicability and limitations of this proposed workflow within an electromagnetic modelling scenario where an energized well is deviated, such as at the Frontier Observatory for Research in Geothermal Energy site. Using the workflow, we demonstrate that the combined use of the energized casing source and the borehole electromagnetic receiver system offer measurable magnetic field amplitudes and sensitivity to the deep localized stimulated zone. The measurements can also distinguish between parallel-fracture anisotropic reservoirs and isotropic cases, providing valuable insights into the fracture system of the stimulated zone. Besides the magnetic field measurements, vertical electric field measurements in the open well sections are also highly sensitive to the stimulated zone and can be used as additional data for detecting and imaging the target. We can also acquire additional multiple-source data by grounding the surface electrode at various locations and repeating borehole electromagnetic measurements. This approach can increase the number of monitoring data by several factors, providing a more comprehensive dataset for analysing the deep-localized stimulated zone. The numerical analysis indicates that it is feasible to use the combination of the energized casing and downhole electromagnetic measurements in monitoring localized stimulated zone at large depths.

58 GEOSCIENCES↗

Magnetic Field Mapping Design for the MOLLER Spectrometer Magnets at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) has developed a unique spectrometer system to study the weak interaction between electrons. The "Measurement of Lepton-Lepton Electroweak Reaction" (MOLLER) experiment, utilizing JLab's recent 12 GeV electron beam upgrade, is scheduled to operate for three years. Central to the MOLLER experiment are five water-cooled toroidal magnets, each with a unique geometry and seven-fold symmetry, designed to focus the particles. These magnets generate the magnetic field needed to separate incident beam electrons scattered from target electrons (Møller scattering) and protons (elastic e-p scattering) within a liquid hydrogen target. Here, this paper details the magnet field measuring technique developed to map all five MOLLER toroidal magnets at multiple locations inside and along the bore. It covers the design, mounting, and operation of the probe, along with the calibration procedure to determine the field and to prepare a field map for GEANT4 analysis. Additionally, the paper addresses the challenges of accurately measuring low magnetic fields.

Ghoshal, Probir K. [Thomas Jefferson National Acce↗

Systematic and statistical uncertainties of the hilbert-transform based high-precision FID frequency extraction method

Pulsed nuclear magnetic resonance (NMR) is widely used in high-precision magnetic field measurements. The absolute value of the magnetic field is determined from the precession frequency of nuclear magnetic moments. The Hilbert transform is widely used to extract the phase function from the observed free induction decay (FID) signal and then its frequency. In this paper, a detailed implementation of a Hilbert-transform based FID frequency extraction method is described. How artifacts and noise level in the FID signal affect the extracted phase function are derived analytically. A method of mitigating the artifacts in the extracted phase function of an FID is discussed. Correlations between noises of the phase function samples are studied for different noise spectra. We discovered that the error covariance matrix for the extracted phase function is nearly singular and improper for constructing the $\chi^2$ used in the fitting routine. A down-sampling method for fixing the singular covariance matrix has been developed, so that the minimum $\chi^2$-fit yields properly the statistical uncertainty of the extracted frequency. Other practical methods of obtaining the statistical uncertainty are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced flip-coil system for magnetic field integral measurements of insertion devices

A novel flip-coil measurement system has been developed for the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Laboratory. This paper describes the design, implementation, and commissioning of the new measurement bench, highlighting its key features, including improved mechanical stability, advanced data acquisition, and enhanced reproducibility. The system enables precise characterization of field integrals and multipole components, ensuring the optimal performance of Insertion Devices (IDs) before installation in the NSLS-II storage ring. The flip-coil system incorporates an innovative approach to minimize mechanical and electrical errors, which significantly improves the reproducibility of measurements. In addition, the system features a state-of-the-art data acquisition system that enables real-time monitoring and analysis, further enhancing the efficiency and accuracy of the measurement process. Furthermore, preliminary tests have demonstrated that the new system meets the stringent requirements for magnetic field characterization of advanced insertion devices, making it an essential tool for future ID commissioning and quality assurance at NSLS-II.

36 MATERIALS SCIENCE↗

Magnetic Navigation for GPS-Denied Airborne Applications

Most current flight systems are dependent on GPS for navigation. Recently, however, navigation in GPS-denied environments has become an area of intensive research. Additional navigation sensor data can be obtained from visual observations (stars or terrain), inertial measurement units, radar, measurements of the local magnetic field, or perhaps even gravity. Absolute and relative positioning via magnetic field measurements have been shown to be viable in many applications including ground navigation, low altitude aircraft flight, and spaceflight. There is greater variability in the magnetic field over shorter distances when flying at low altitude and in ground applications, leading to more accurate positioning. However, ground-based magnetic navigation is often heavily influenced by man-made structures, especially in urban environments. This is not the case for airborne magnetic navigation since the influence of buildings, roads, etc. is negligible for typical aircraft altitudes. For absolute magnetic navigation, the positioning accuracy decreases as altitude increases for a given vehicle velocity, but the observed time variability in the field can be reclaimed by traveling faster through the field. Thus, navigation accuracy becomes a balance of speed and altitude since the higher altitude can be counterbalanced by higher velocity. To understand these effects quantitatively, we explored various techniques to aid a simulated inertial measurement unit with magnetic information. Using a technique known as two-dimensional magnetic map matching, we simulated the performance of airborne magnetic navigation at fixed speed while varying the altitude, flight direction, magnetometer data collection time, reference magnetic map bias error, and type of trajectory (over land or over ocean).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An assessment of generating quasi-static magnetic fields using laser-driven “capacitor” coils

Over the previous decade, numerous experiments have been performed using a laser to drive a strong, quasi-static magnetic field. Field strength and energy density measurements of these experiments have varied by many orders of magnitude, painting a confusing picture of the effectiveness of these laser-driven coils (LDCs) as tools for generating consistent fields. At the higher end of the field energy spectrum, kilotesla field measurements have been used to justify future experimental platforms, theoretical work, and inertial confinement fusion concepts. In this paper, we present the results from our own experiments designed to measure magnetic fields from LDCs as well as a review of the body of experiments that have been undertaken in this field. Here, we demonstrate how problems with prior diagnostic analyses have led to overestimations of the magnetic fields generated from LDCs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Doppler-Free Saturation Spectroscopy (DFSS) for Magnetic and Electric Field Measurements in an FRC plasma

The Cooperative Research and Development Agreement (CRADA) between Oak Ridge National Laboratory (ORNL) and TAE Technologies (TAE) focused on a feasibility study of Doppler-free saturation spectroscopy (DFSS) as a diagnostic strategy to measure the internal magnetic and electric fields of TAE’s C-2W field-reversed configuration (FRC) fusion device. Non-perturbative measurements of magnetic and electric fields in the core of FRCs can provide critical information needed to constrain equilibrium models and for the continued advancement of the fusion research program at TAE. DFSS is a well-established, laser-based absorption spectroscopy technique used to suppress inhomogeneous (Doppler) broadening linewidths and reveal Zeeman/Stark split hyperfine structures of target emission lines. The collaboration involved the use of ORNL’s suite of experimentally validated quantum mechanical modelling codes to simulate theoretical atomic spectra for a variety of machine parameters and laser beam configurations. TAE’s expertise was heavily used to provide measurements/models of the required machine parameters needed as inputs to the simulations. Results of an all-encompassing error analysis demonstrate the favourable capabilities of the diagnostic and provided invaluable insights as to how DFSS can be best used to accurately measure internal B/E-fields in C-2W.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High repetition rate exploration of the Biermann battery effect in laser produced plasmas over large spatial regions

Abstract In this paper we present a high repetition rate experimental platform for examining the spatial structure and evolution of Biermann-generated magnetic fields in laser-produced plasmas. We have extended the work of prior experiments, which spanned over millimeter scales, by spatially measuring magnetic fields in multiple planes on centimeter scales over thousands of laser shots. Measurements with magnetic flux probes show azimuthally symmetric magnetic fields that range from 60 G at 0.7 cm from the target to 7 G at 4.2 cm from the target. The expansion rate of the magnetic fields and evolution of current density structures are also mapped and examined. Electron temperature and density of the laser-produced plasma are measured with optical Thomson scattering and used to directly calculate a magnetic Reynolds number of $1.4\times {10}^4$ , confirming that magnetic advection is dominant at $\ge 1.5$ cm from the target surface. The results are compared to FLASH simulations, which show qualitative agreement with the data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A custom high-stability pulse generator for the test of a novel in-situ magnetic sensor developed to detect radiation damage in undulators

High-performance analog-to-digital converters (ADC) have been widely applied in many areas of science. For instance, magnetic field measurements based on the Faraday’s induction law require high-precision voltmeters to measure induced voltages. In this study in the context of free-electron lasers technology, the Magnetic Measurements Team at SLAC National Accelerator Laboratory proposed a novel in-situ radiation damage detection system (RDDS) for detecting small field variations in undulators. The system measures the flux change in a flexible printed-circuit coil attached to the magnet array during the undulator gap movement. The gap movement changes the magnetic field, which induces a voltage signal in the coil that is measured and integrated with an ADC. Although the system is capable of detecting relative flux changes better than 100 ppm, drift in the ADC’s gain or offset can cause apparent changes in the relative flux. This paper describes the first attempt to developed a high-precision verification circuit to perform ADC testing in the framework of the novel RDDS. The circuit generates a reference voltage pulse with a voltage–time integral relative precision better than 50 ppm for a few hundreds of mVs — the typical order of magnitude measured with the RDDS. The circuit’s design combines a fast and precise switch with a low-noise voltage reference. Long-term measurements allowed statistical analysis and showed that averaging the voltage–time integral of ten pulses gives the required 50 ppm stability. Moreover, reproducibility tests confirmed that the circuit’s output is invariable under small power supply instabilities and equipment shutdown. Instruments and applications designed to quantify the magnetic field by integrating voltage signals may use the pulse generator proposed in this paper for verification purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Small bore magnetic measurement system, method for measuring small bore magnets

The invention provides a system for measuring magnets, the system comprising a guide tube removably received by a beam chamber tunnel, wherein said guide tube has a first end terminating at a first end of the tunnel and a second end terminating at a second end of the tunnel; a flexible substrate removably and slidably received by the tube, wherein the flexible substrate has a first end and a second end; a first rotary stage removably attached to the first end of said flexible substrate and a second rotary stage removably attached to the second end of said flexible substrate wherein the first rotary stage and the second rotary stage effects movement of the substrate through the tube; and a Hall probe supported by the flexible substrate. Also provided is a method for measuring magnetic fields, the method comprising extending a measuring probe into a magnetic core while maintaining the probe at ambient temperature and pressure.

Kasa, Matthew T.↗

Diagnosing magnetic fields in cylindrical implosions with oblique proton radiography

Two experiments at the OMEGA Laser System used oblique proton radiography to measure magnetic fields in cylindrical implosions with and without an applied axial magnetic field. Although the goal of both experiments was to measure the magnitude of the compressed axial magnetic field in the core of the implosion, this field was obfuscated by two features in the coronal plasma produced by the compression beams: an azimuthal self-generated magnetic field and small length scale, high-amplitude structures attributed to collisionless effects. In order to understand these features, synthetic radiographs are generated using fields produced by 3D HYDRA simulations. These synthetic radiographs reproduce the features of the experimental radiographs with the exception of the small-scale structures. A direct inversion algorithm is successfully applied to a synthetic radiograph but is only partially able to invert the experimental radiographs in part because some protons are blocked by the field coils. The origins of the radiograph features and their dependence on various experimental parameters are explored. Furthermore, the results of this analysis should inform future measurements of compressed axial magnetic fields in cylindrical implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗