Search NASA⌕ Search

SEARCH · Search NASA

Results for “Magnetic Resonance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Identification of preferred multimodal ligand‐binding regions on IgG1 F C using nuclear magnetic resonance and molecular dynamics simulations

Abstract In this study, the binding of multimodal chromatographic ligands to the IgG1 F C domain were studied using nuclear magnetic resonance and molecular dynamics simulations. Nuclear magnetic resonance experiments carried out with chromatographic ligands and a perdeuterated 15 N‐labeled F C domain indicated that while single‐mode ion exchange ligands interacted very weakly throughout the F C surface, multimodal ligands containing negatively charged and aromatic moieties interacted with specific clusters of residues with relatively high affinity, forming distinct binding regions on the F C . The multimodal ligand‐binding sites on the F C were concentrated in the hinge region and near the interface of the C H 2 and C H 3 domains. Furthermore, the multimodal binding sites were primarily composed of positively charged, polar, and aliphatic residues in these regions, with histidine residues exhibiting some of the strongest binding affinities with the multimodal ligand. Interestingly, comparison of protein surface property data with ligand interaction sites indicated that the patch analysis on F C corroborated molecular‐level binding information obtained from the nuclear magnetic resonance experiments. Finally, molecular dynamics simulation results were shown to be qualitatively consistent with the nuclear magnetic resonance results and to provide further insights into the binding mechanisms. An important contribution to multimodal ligand‐F C binding in these preferred regions was shown to be electrostatic interactions and π–π stacking of surface‐exposed histidines with the ligands. This combined biophysical and simulation approach has provided a deeper molecular‐level understanding of multimodal ligand–F C interactions and sets the stage for future analyses of even more complex biotherapeutics.

Gudhka, Ronak B.↗

Operando nuclear magnetic resonance rotor insert

A magic angle sample spinning nuclear magnetic resonance system including a housing, a cryogenic fluid in the housing, a magnet in the housing, a probe in the housing, a magic angle sample spinning insert in the probe, a sample battery in the magic angle sample spinning insert, a photovoltaic cell in the magic angle sample spinning insert wherein the photovoltaic cell is connected to the sample battery, an optic fiber operatively connected to the photovoltaic cell, and a laser operatively connected to the optic fiber wherein the laser provides power to charge the sample battery during the magic angle sample spinning nuclear magnetic resonance.

Marple, Maxwell↗

Neural Network Analysis of Nuclear Magnetic Resonance and Infrared Spectra

Nuclear magnetic resonance (NMR) spectroscopy and infrared (IR) spectroscopy are powerful chemical characterization techniques with broad general usage. However, the manual evaluation of the resulting spectra is time-consuming and requires significant expertise, preventing insights from being used in real-time applications. With recent advances in computation and artificial intelligence (AI), new tools are available for automating spectral interpretation. In this work, machine learning (ML) algorithms using 1-dimensional convolutional neural networks (CNNs) were applied to identify common functional groups from spectral information. Raw spectra were collected virtually from the Human Metabolome Database (HMDB) and National Institute of Standards and Technology (NIST) Chemistry WebBook and processed into a suitable standard. Algorithm design was tailored to best fit the nature of the problem, with built-in flexibility to accommodate relevant parameters beyond the raw spectral input, specifically solvent identity and magnetic frequency for NMR. The predictive capability of the algorithm in identifying functional groups is displayed in several examples. This methodology has been compiled into a code repository and could easily be modified to adapt alternative data sources, including other spectrum types. To mitigate overfitting, a common problem in mathematical modeling where overfamiliarity with training data produces trends that are not representative of the general data, a novel metric was developed, referred to as Accufit. Accufit includes a parameter that penalizes substantial differences in the training accuracy and the accuracy of an independent validation set. Examples are presented showing the effectiveness of Accufit in maintaining the model’s predictive capability while controlling the overfitting when used as a custom metric for hyperparameter tuning.

Sturgill, James↗

Design and evaluation of an open-source, conformable skin-cooling system for body magnetic resonance guided focused ultrasound treatments

Magnetic resonance guided focused ultrasound (MRgFUS) treatment of tumors uses inter-sonication delays to allow heat to dissipate from the skin and other near-field tissues. Despite inter-sonication delays, treatment of tumors close to the skin risks skin burns. This work has designed and evaluated an open-source, conformable, skin-cooling system for body MRgFUS treatments to reduce skin burns and enable ablation closer to the skin. A MR-compatible skin cooling system is described that features a conformable skin-cooling pad assembly with feedback control allowing continuous flow and pressure maintenance during the procedure. System performance was evaluated with hydrophone, phantom and in vivo porcine studies. Sonications were performed 10 and 5 mm from the skin surface under both control and forced convective skin-cooling conditions. 3D MR temperature imaging was acquired in real time and the accumulated thermal dose volume was measured. Gross analysis of the skin post-sonication was further performed. Device conformability was demonstrated at several body locations. Hydrophone studies demonstrated no beam aberration, but a 5–12% reduction of the peak pressure due to the presence of the skin-cooling pad assembly in the acoustic near field. Phantom evaluation demonstrated there is no MR temperature imaging precision reduction or any other artifacts present due to the coolant flow during MRgFUS sonication. The porcine studies demonstrated skin burns were reduced in size or eliminated when compared to the control condition. An open-source design of an MRgFUS active skin cooling system demonstrates device conformability with a reduction of skin burns while ablating superficial tissues.

60 APPLIED LIFE SCIENCES↗

The Natural Products Magnetic Resonance Database (NP-MRD) for 2025

The Natural Products Magnetic Resonance Database or NP-MRD (https://np-mrd.org) is a comprehensive, freely accessible, web-based resource for the deposition, distribution, extraction and retrieval of nuclear magnetic resonance (NMR) data on natural products. The NP-MRD was initially established to support compound de-replication and data dissemination for the natural products community. However, that community has now grown to include many users from the metabolomics, microbiomics, foodomics and nutrition science fields. Indeed, since its launch in 2021, the NP-MRD has expanded enormously in size, scope and popularity. The current version of NP-MRD now contains nearly 7X more compounds (281,859 vs. 40,908) and 7X more NMR spectra (5.1 million vs. 817,000) than the first release. More specifically, an additional 4.6 million predicted spectra and another 11,000 spectra simulated from experimental chemical shifts were deposited into the database. Likewise, the number of NMR raw spectral data depositions has grown from a 165 spectra per year to more than 10,000 per year. As a result of this expansion, the number of monthly webpage views has grown from 55 to 20,000 and the number of monthly visitors has increased from 7 to 2500. To address this growth and to better support the expanding needs of its diverse community of users, many additional improvements to the NP-MRD have been made. These include significant enhancements to the data submission process, important improvements to the visualization and display of NMR spectra, notable updates to the database’s spectral search utilities and useful additions to support better NMR spectral analysis/prediction. Significant efforts have also been undertaken to remediate and update many of NP-MRD’s database entries. This manuscript describes these database improvements and expansion efforts, along with how they have been implemented and what future upgrades to the NP-MRD are planned.

Artifical Intelligence↗

Opportunities and Limitations of Nuclear Magnetic Resonance Spectroscopy in Astrobiology

For decades, Nuclear Magnetic Resonance (NMR) spectroscopy has been utilized as a powerful tool in various scientific disciplines, most prominently in chemistry, to determine molecular structures or monitor reactions. While well established in various fields, NMR applications in astrobiology are still unclear. This work aims to explore the potential of NMR in astrobiology, highlighting strengths but also weaknesses. We illustrate capabilities of NMR with two applications: (1) recently developed methods for position-specific carbon isotope analysis of complex organics; and (2) well-established tools for performing quantitative compositional analysis of complex organic mixtures. By utilizing samples relevant to astrobiology, specifically the amino acid valine and analogue mixtures of organics, we showcase that molecules retain a source dependent and distinct intramolecular carbon isotope fingerprint. We demonstrate that compositional sample analysis provides an independent and complementary line of evidence pointing towards the origin of a molecule or mixture. Together, these NMR tools have the potential to support life detection efforts, and aid in distinguishing between biotic and abiotic samples. Finally, we discuss sensitivity, detection limits, the portability of NMR, and propose how integration with mass-spectrometry techniques will be imperative to enable more targeted and comprehensive analyses relevant to astrobiology, including in-situ analysis but also sample return missions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Correction of Q Factor Effects for Simultaneous Collection of Elemental Analysis and Relaxation Times by Nuclear Magnetic Resonance

A new method for measurement of elemental analysis by nuclear magnetic resonance (NMR) of unknown samples is discussed in this report as a quick and robust means to measure elemental ratios without the use of internal or external calibration standards. The determination of elemental ratios was done by normalizing the signal intensities by the frequency dependent quality factor (Q) and the gyromagnetic ratios (γ) for each measured nucleus. The correction for the frequency dependence was found by characterizing the output signal of the probe as a function of the quality factor (Q) and the frequency, and the correction for γ was discussed in a previous study. A Carr–Purcell–Meiboom–Gill (CPMG) pulse sequence was used for evaluation of the relative signal intensities, which allows for derivation of elemental ratios, and was correspondingly used to simultaneously measure the T 2 * of samples for an added parameter for more accurate identification of unknown samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calibration of the Solid‐State Nuclear Magnetic Resonance Search for Axion‐Like Dark Matter

Abstract Calibration of nuclear‐magnetic‐resonance‐based searches for axion‐like dark matter can be performed by free induction decay (FID) measurements. This manu‐ script describes FID experiments on several solid materials, motivated by the Cosmic Axion Spin Precession Experiment (CASPEr) program. Experiments with 207 Pb nuclear spins in ferroelectrics, lead magnesium niobate‐lead titanate (PbMg 1/3 Nb 2/3 O 3 ) (PbTiO 3 ) 1/3 (PMN‐PT) and lead zirconium titante PbZr 0.52 Ti 0.48 O 3 (PZT) are directly relevant to the CASPEr‐electric search for the electric dipole moment interaction of axion‐like dark matter. Experiments with 31 P nuclear spins in gadolinium‐doped hydroxypyromorphite Pb 4.95 Gd 0.05 (PO 4 ) 3 OH (HPM:Gd) are used for apparatus calibration. The measurements characterized the nuclear spin ensemble coherence time and the magnetic resonance detection sensitivity for these samples. Calibration is performed using small tip‐angle pulses.

Winter, Andrew J.↗

Spatially-resolved dynamic sampling of different phasic magnetic resonances of nanoparticle ensembles in a magnetotactic bacterium Magnetospirillum magnetotacticum

Abstract Nanoscaled magnetic particle ensembles are promising building blocks for realizing magnon based binary logic. Element-specific real-space monitoring of magnetic resonance modes with sampling rates in the GHz regime is imperative for the experimental verification of future complex magnonic devices. Here we present the observation of different phasic magnetic resonance modes using the element-specific technique of time-resolved scanning transmission x-ray microscopy within a chain of dipolarly coupled Fe 3 O 4 nanoparticles (40–50 nm particle size) inside a single cell of a magnetotactic bacterium Magnetospirillum magnetotacticum . The particles are probed with 25 nm resolution at the Fe L 3 x-ray absorption edge in response to a microwave excitation of 4.07 GHz. A plethora of resonance modes is observed within multiple particle segments oscillating in- and out-of-phase, well resembled by micromagnetic simulations.

time-resolved scanning transmission x-ray microsco↗

Inching toward the QCD axions with axion magnetic resonance in helioscopes

Utilizing a helical magnet profile to enhance axion-photon conversion showed great promise in laboratory searches for high axion masses. We extend the mechanism, known as the axion-magnetic resonance (AMR), from laser experiments to axion helioscopes and demonstrate its potential in covering QCD axion parameter space. Specifically, we apply AMR to the CAST experiment legacy, make projections for the upcoming IAXO experiment, and assess its implications for both axion-like particles and QCD axions. We observe considerable improvement in the experiment’s sensitivity reach in all cases.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Integrated control of edge localized modes and divertor flux using mixed toroidal harmonic resonant magnetic perturbations in EAST

Mixed harmonic resonant magnetic perturbations (RMPs) for integrated edge localized modes (ELMs) and divertor flux control are demonstrated in EAST target plasmas of low input torque and normalized beta β N ~1.7–1.9, which are close to the equivalent value in ITER high Q operation. The applied RMPs are designed to combine a static harmonic of the toroidal mode number n = 3 with a static or rotating harmonic of n = 2. ELM suppression is achieved without a drop of plasma energy confinement, and tungsten concentration is effectively reduced during the application of RMPs. With mixed harmonics, the toroidal varying steady state heat and particle fluxes on the divertor target can be modified with the rotating n = 2 harmonic, which agrees with the numerical modeling of three-dimensional magnetic topology, with plasma responses being taken into account. ELM suppression correlates with the times of larger n = 3 response with mixed n = 2 and n = 3 RMPs. The mixture of harmonics and the rotating n = 2 harmonic does not require additional coil current because the variation is only in the upper-lower coil current phase space. Furthermore, these results further affirm the effectiveness of integrated ELM and divertor flux control using RMPs with mixed harmonics and improve the understanding of the role of plasma responses in ELM suppression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-sensitivity in vivo contrast for ultra-low field magnetic resonance imaging using superparamagnetic iron oxide nanoparticles

Magnetic resonance imaging (MRI) scanners operating at ultra-low magnetic fields (ULF; <10 mT) are uniquely positioned to reduce the cost and expand the clinical accessibility of MRI. A fundamental challenge for ULF MRI is obtaining high-contrast images without compromising acquisition sensitivity to the point that scan times become clinically unacceptable. Here, we demonstrate that the high magnetization of superparamagnetic iron oxide nanoparticles (SPIONs) at ULF makes possible relaxivity- and susceptibility-based effects unachievable with conventional contrast agents (CAs). We leverage these effects to acquire high-contrast images of SPIONs in a rat model with ULF MRI using short scan times. This work overcomes a key limitation of ULF MRI by enabling in vivo imaging of biocompatible CAs. These results open a new clinical translation pathway for ULF MRI and have broader implications for disease detection with low-field portable MRI scanners.

42 ENGINEERING↗

Tailoring resonant magnetic perturbation to optimize fast-ion confinement during ELM control in KSTAR

Abstract 3D resonant magnetic perturbation (RMP) is one promising way to control edge localized modes that can cause excessive material erosion of tokamak first walls. However, RMP can lead to undesired degradation of plasma confinement, including fast-particle losses, which can impact the performance and safety of the reactor. This work investigates the optimization of the poloidal spectrum of the 3D field to optimize fast ion confinement during edge localized mode (ELM) suppression. In the initial step, the validity of the modeling framework is tested against experimental data. Simulations successfully replicate an increase in poloidal limiter temperature with different poloidal spectra. Then, the simulation shows improvement of fast ion confinement with a reduction of core resonant response, while edge resonant magnetic fields are maintained above the threshold to sustain the ELM suppression. Reduction of the core resonant fields keeps the Kolmogorov–Arnold–Moser surface and reduces the fast particle losses due to the stochastic magnetic field lines. The results highlight the potential of edge localization of the resonant fields to enhance the performance of fusion reactors, but further investigation is needed to improve the validation of this approach.

3D field↗

The effect of magnetic susceptibility and magnetic field strength on porosity estimates determined from low-field nuclear magnetic resonance

The presence of materials with high magnetic susceptibility are known to have an impact on 1H nuclear magnetic resonance (NMR) measurements and in laboratory data this often results in poor estimates of porosity from NMR data. To quantify and understand the cause of the poor NMR porosity estimations, in this laboratory study, we examine the effect of magnetic susceptibility, NMR measurement parameters, and NMR instrument design on NMR measurements. Data were collected with two instruments, each with a different Larmor frequency (2 MHz and 485 kHz), on water-saturated unconsolidated sediments with magnetic susceptibility values ranging from 3.6 × 10 -6 to 7020 × 10 -6 SI. The results show that for materials with low magnetic susceptibility (<378 × 10 -6 SI), the gravimetric porosity is accurately predicted from the NMR measurements. For the samples with high magnetic susceptibility (>987 × 10 -6 SI) the gravimetric porosity is poorly predicted from the 2 MHz NMR measurements made at all echo times (from 0.2 to 3.0 ms). In contrast, the gravimetric porosity is more accurately predicted at an echo time of 0.2 ms for measurements made using the 485 kHz instrument, although at larger echo times (>1.0 ms), the porosity estimate becomes poor. The 485 kHz NMR instrument has non-zero internal magnetic field gradients, similar to those found in borehole instruments, in contrast to the 2 MHz NMR instrument, which has a homogeneous applied magnetic field. Finally, we conclude that differences is the magnetic field strength and higher magnetic field inhomogeneities in the 485 kHz NMR instrument contribute to a reduction of the impact of inhomogeneities in the magnetic field caused by materials with high magnetic susceptibility, allowing for improved porosity estimation. These results indicate that NMR measurements collected at short echo times in low, inhomogeneous static fields, e.g., borehole instruments, may provide accurate estimates of porosity in water saturated sediments, even in the presence of magnetic minerals.

58 GEOSCIENCES↗

Localizing resonant magnetic perturbations for edge localized mode control in KSTAR

An external 3D magnetic perturbation typically drives a resonant response at the rational surfaces from the core to the edge of tokamak plasmas, due to strong mode coupling and amplification. In this paper, we present a method to isolate the edge from core resonant fields using the ideal perturbed equilibrium code and to design an edge-localized resonant magnetic perturbation (RMP) for effective edge localized mode (ELM) control. A robust feature of the edge-localized RMP is the curtailed response to the field at the low-field-side (LFS) midplane, as opposed to typical RMPs which strongly resonate with the LFS fields. This emphasizes the importance of off-midplane coils to improve ELM control without provoking a large core response that could lead to devastating instabilities. The conceptual design of new ELM control coils based on the edge-localized RMP in KSTAR shows how this new insight can be utilized to enhance the efficiency of our ELM suppression capabilities. Simple window-pane coils matching the edge-localized resonant mode structure substantially expand in the ELM suppression window beyond the existing coil. Further optimization using the flexible optimized coils using space-curves code leads to additional enhancement in the edge-localized control.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of stationary filaments with resonant magnetic perturbations in NSTX

The application of resonant magnetic perturbations (RMPs) induces striated heat fluxes on the divertor plate in tokamaks. These striated heat fluxes were previously considered strike point splitting by the intersection between the divertor and predicted magnetic lobe structures. Recently, the existence of stationary 3D filaments has been observed for the first time in National Spherical Torus Experiment (NSTX) plasmas with toroidal mode number n = 3 RMPs. Magnetic field line tracing of these filaments from the midplane to the divertor is consistent with the quantity and the radial and toroidal location of striated heat fluxes observed on the divertor. This study suggests that divertor striated heat flux patterns are linked to these stationary filaments rather than to strike point splitting or magnetic lobe structures for NSTX. This finding will help guide future efforts to understand the heat flux striations in NSTX with RMPs in order to control and reduce the divertor peak heat flux.

RMPs↗

Divertor detachment in the pre-fusion power operation phase in ITER during application of resonant magnetic perturbations

Detachment of the divertor plasma during application of resonant magnetic perturbation (RMP) fields is evaluated for hydrogen H-mode plasma during the first pre-fusion power operation (PFPO-1) phase in ITER by 3D plasma boundary modelling with EMC3–EIRENE. Plasma response effects from a linearized, resistive, single fluid MHD model are discussed, which includes partial screening of the externally applied field—but also field amplification near the separatrix. Furthermore, this field amplification is found to play a pivotal role for the magnetic footprint on the divertor targets, but is sensitive to model parameters. Extensions of the footprint beyond the straight portions of the ITER vertical divertor targets, optimized for high stationary heat flux handling, may be possible depending on the level of toroidal rotation in the plasma. Exhaust from the bulk plasma is guided by the helical corrugations (lobes) of the perturbed separatrix, and this results in an upstream heat flux that is distributed over these lobes with lower peak values than in the typical radial heat flux profiles seen in the absence of magnetic perturbations. As a consequence, an earlier onset (with respect to the upstream density) of detachment is found in the traditional strike zone when RMPs are applied, but secondary, non-axisymmetric strike locations appear—and those remain attached at temperatures above 10 eV. Neon seeding can mitigate these non-axisymmetric heat loads, but this becomes less efficient for large magnetic footprints.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic resonance force microscopy with matching frequencies of cantilever and spin

We have studied theoretically magnetic resonance force microscopy with a high-frequency nanomechanical cantilever when the cantilever frequency matches the resonant frequency of a single electron spin. Our analysis shows that in this situation, there is a small probability that the cantilever will oscillate with a large frequency shift. In conclusion, this can open new experimental opportunities for increasing the sensitivity in the detection of a single electron spin or even a single nuclear spin by using a high-frequency cantilever.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗