Search NASA⌕ Search

SEARCH · Search NASA

Results for “Magnetometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

High field magnetometry with hyperpolarized nuclear spins

Abstract Quantum sensors have attracted broad interest in the quest towards sub-micronscale NMR spectroscopy. Such sensors predominantly operate at low magnetic fields. Instead, however, for high resolution spectroscopy, the high-field regime is naturally advantageous because it allows high absolute chemical shift discrimination. Here we demonstrate a high-field spin magnetometer constructed from an ensemble of hyperpolarized 13 C nuclear spins in diamond. They are initialized by Nitrogen Vacancy (NV) centers and protected along a transverse Bloch sphere axis for minute-long periods. When exposed to a time-varying (AC) magnetic field, they undergo secondary precessions that carry an imprint of its frequency and amplitude. For quantum sensing at 7T, we demonstrate detection bandwidth up to 7 kHz, a spectral resolution < 100mHz, and single-shot sensitivity of 410pT $$/\sqrt{{{{{{{{\rm{Hz}}}}}}}}}$$ / Hz . This work anticipates opportunities for microscale NMR chemical sensors constructed from hyperpolarized nanodiamonds and suggests applications of dynamic nuclear polarization (DNP) in quantum sensing.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A physically unclonable function using NV diamond magnetometry and micromagnet arrays

A physically unclonable function (PUF) is an embedded hardware security measure that provides protection against counterfeiting. In this article, we present our work on using an array of randomly magnetized micrometer-sized ferromagnetic bars (micromagnets) as a PUF. We employ a 4μm thick surface layer of nitrogen-vacancy (NV) centers in diamond to image the magnetic field from each micromagnet in the array, after which we extract the magnetic polarity of each micromagnet using image analysis techniques. Finally, after evaluating the randomness of the micromagnet array PUF and the sensitivity of the NV readout, we conclude by discussing the possible future enhancements for improved security and magnetic readout.

Electromagnetism↗

Electron beam characterization via quantum coherent optical magnetometry

We present a quantum optics-based detection method for determining the position and current of an electron beam. As electrons pass through a dilute vapor of rubidium atoms, their magnetic field perturbs the atomic spin's quantum state and causes polarization rotation of a laser resonant with an optical transition of the atoms. By measuring the polarization rotation angle across the laser beam, we recreate a 2D projection of the magnetic field and use it to determine the e-beam position, size, and total current. We tested this method for an e-beam with currents ranging from 30 to 110 μA. Our approach is insensitive to electron kinetic energy, and we confirmed that experimentally between 10 and 20 keV. In conclusion, this technique offers a unique platform for noninvasive characterization of charged particle beams used in accelerators for particle and nuclear physics research.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fault localization in a microfabricated surface ion trap using diamond nitrogen-vacancy center magnetometry

Here, as quantum computing hardware becomes more complex with ongoing design innovations and growing capabilities, the quantum computing community needs increasingly powerful techniques for fabrication failure root-cause analysis. This is especially true for trapped-ion quantum computing. As trapped-ion quantum computing aims to scale to thousands of ions, the electrode numbers are growing to several hundred, with likely integrated photonic components also adding to the electrical and fabrication complexity, making faults even harder to locate. In this work, we used a high-resolution quantum magnetic imaging technique, based on nitrogen-vacancy centers in diamond, to investigate short-circuit faults in an ion trap chip. We imaged currents from these short-circuit faults to ground and compared them to intentionally created faults, finding that the root cause of the faults was failures in the on-chip trench capacitors. This work, where we exploited the performance advantages of a quantum magnetic sensing technique to troubleshoot a piece of quantum computing hardware, is a unique example of the evolving synergy between emerging quantum technologies to achieve capabilities that were previously inaccessible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-accuracy absolute magnetometry with application to the Fermilab Muon g-2 experiment

We present details of a high-accuracy absolute scalar magnetometer based on pulsed proton NMR. The B-field magnitude is determined from the precession frequency of proton spins in a cylindrical sample of water after accounting for field perturbations from probe materials, sample shape, and other corrections. Features of the design, testing procedures, and corrections necessary for qualification as an absolute scalar magnetometer are described. The device was tested at B = 1.45 T but can be modified for a range exceeding 1–3 T. The magnetometer was used to calibrate other NMR magnetometers and measure absolute magnetic field magnitudes to an accuracy of 19 parts per billion as part of a measurement of the muon magnetic moment anomaly at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spin magnetometry as a probe of stripe superconductivity in twisted bilayer graphene

The discovery of alternating superconducting and insulating ground states in magic angle graphene has suggested an intriguing analogy with cuprate high-T c materials. In this paper we argue that the network states of small angle twisted bilayer graphene (TBG) afford a further perspective on the cuprates by emulating their stripe-ordered phases, as in La 1.875 Ba 0.125 CuO 4 . We show that the spin and valley quantum numbers of stripes in TBG graphene fractionalize, developing characteristic signatures in the tunneling density of states and the magnetic noise spectrum of impurity spins. By examining the coupling between the charge rivers we determine the superconducting transition temperature. Our study suggests that twisted bilayer graphene can be used for a controlled emulation of stripe superconductivity and quantum sensing experiments of emergent anyonic excitations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nanoscale covariance magnetometry with diamond quantum sensors

Nitrogen vacancy (NV) centers in diamond are atom-scale defects that can be used to sense magnetic fields with high sensitivity and spatial resolution. Typically, the magnetic field is measured by averaging sequential measurements of single NV centers, or by spatial averaging over ensembles of many NV centers, which provides mean values that contain no nonlocal information about the relationship between two points separated in space or time. In this work, we propose and implement a sensing modality whereby two or more NV centers are measured simultaneously, and we extract temporal and spatial correlations in their signals that would otherwise be inaccessible. We demonstrate measurements of correlated applied noise using spin-to-charge readout of two NV centers and implement a spectral reconstruction protocol for disentangling local and nonlocal noise sources.

47 OTHER INSTRUMENTATION↗

Spin-squeezed vector atomic magnetometry

Atomic magnetometers based on Zeeman shift measurement have the potential for high sensitivity and long-term stability. Like other atomic sensors, including atomic clocks and atom interferometers, the atomic magnetometer could, in principle, be augmented with spin squeezing for further sensitivity enhancement. However, existing atomic magnetometers are not compatible with spin squeezing because the atoms can hardly be in a pure quantum state during operation. Moreover, a natural challenge faced by an atomic magnetometer is the arbitrary direction of the magnetic field. In this paper, we propose a cold-atom-based magnetometer with spin squeezing that can measure both the magnitude and the direction of an arbitrary magnetic field. For experimentally accessible parameters, we show that the technique described above could potentially achieve a sensitivity nearly two orders of magnitude higher than that of the best existing magnetometers.

Li, Jinyang [Northwestern U.] (ORCID:0000000194328↗

Optically pumped, radio-frequency atomic magnetometry with feedback stabilization

An optically pumped, atomic magnetometer incorporates a feedback system for stabilizing the magnetic bias field and suppressing unwanted background fields. The magnetic bias field is applied to a vapor cell containing host atoms of two different species, each of which resonates at a different Larmor frequency when both are subjected to the same magnetic bias field. One species provides the feedback for stabilizing the bias field, thereby creating a stabilizing magnetometer portion that nulls out the unwanted background fields. The other species provides magnetic field detection or signal reception on a radio communication frequency of interest, thereby creating a signal magnetometer portion that permits detection of the signal at the radio communication frequency.

Schwindt, Peter D. D.↗

Light dark matter search with nitrogen-vacancy centers in diamonds

We propose an approach to directly search for light dark matter, such as the axion or the dark photon, by using magnetometry with nitrogen-vacancy centers in diamonds. If the dark matter couples to the electron spin, it affects the evolution of the Bloch vectors consisting of the spin triplet states, which may be detected through several magnetometry techniques. We give several concrete examples with the use of dc and ac magnetometry and estimate the sensitivity on dark matter couplings.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Wide-field microwave magnetic field imaging with nitrogen-vacancy centers in diamond

Non-invasive imaging of microwave (MW) magnetic fields with microscale lateral resolution is pivotal for various applications, such as MW technologies and integrated circuit failure analysis. Diamond nitrogen-vacancy (NV) center magnetometry has emerged as an ideal tool, offering micrometer-scale resolution, millimeter-scale field of view, high sensitivity, and non-invasive imaging compatible with diverse samples. However, up until now, it has been predominantly used for imaging of static or low-frequency magnetic fields or, concerning MW field imaging, to directly characterize the same microwave device used to drive the NV spin transitions. In this work, we leverage an NV center ensemble in diamond for wide-field imaging of MW magnetic fields generated by a test device employing a differential measurement protocol. The microscope is equipped with a MW loop to induce Rabi oscillations between NV spin states, and the MW field from the device-under-test is measured through local deviations in the Rabi frequency. This differential protocol yields magnetic field maps of a 2.57 GHz MW field with a sensitivity of ∼9 μT Hz −1/2 for a total measurement duration of T=357 s, covering a 340 × 340 μm 2 field of view with a micrometer-scale spatial resolution and a device-under-test input power dynamic range of 30 dB. This work demonstrates a novel NV magnetometry protocol, based on differential Rabi frequency measurement, that extends NV wide-field imaging capabilities to imaging of weak MW magnetic fields that would be difficult to measure directly through standard NV Rabi magnetometry.

crystallographic defects↗

Determining the nature of magnetism in altermagnetic candidate RuO 2

The terminology “altermagnetism” has recently been adopted to describe collinear magnetic order with no net magnetization and nonrelativisitic, momentum-dependent spin splitting. The archetypal material used to theoretically explore altermagnetism is RuO 2 , but there has been significant debate as to whether RuO 2 possesses magnetic, let alone altermagnetic, order. To address questions surrounding the nature of magnetism in RuO 2 , we combine symmetry-sensitive torque magnetometry and magnetization measurements in single crystals up to 31 T. The data are inconsistent with collinear magnetic order possessing a Néel vector along the 𝑐 axis. Torque magnetometry further demonstrates an isotropic, field-independent magnetic susceptibility within the 𝑎⁢𝑏 plane, indicative of neither a Néel vector within the 𝑎⁢𝑏 plane nor a field-induced Néel vector reorientation. Magnetic quantum oscillations from both techniques reveal a nearly spherical Fermi surface pocket at the Brillouin zone center, in agreement with paramagnetic electronic structure calculations. Taken together, these data indicate that high-quality RuO 2 single crystals are itinerant paramagnets with no detectable long-range magnetic order and, by extension, no altermagnetism.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗