Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measure control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Measurement and Control of Beam Energy at the Fermilab 400 MeV Transfer Line

Linac is the first machine in the Accelerator chain at Fermilab where particles are accelerated from 35 keV to 400 MeV and travel to the Booster where they are stripped of the extra electrons to become protons. Tuning Linac is performed using diagnostics to ensure stable intensity and energy while minimizing uncontrolled particle loss. I have been revisiting diagnostics in the Linac in order to understand their signals and to ensure their data is reliable. I revisited Beam Loss Monitors (BLMs) for the loss data confidence. For the confidence of energy data there were two approaches. The first approach was time-of-flight measurements using Beam Position Monitors (BPMs) and beam velocity stripline pick-up that provides beam phase data. The second approach used the relation between beam position data from BPMs and dispersion values from MAD-X simulation to calculate energy. Our goal after understanding the data from the Linac diagnostics and finding the data reliable is to control the L inac parameters using Machine Learning techniques to increase the reliability and quality of beam delivered from Linac.

43 PARTICLE ACCELERATORS↗

Dynamic projection of anthropogenic emissions in China: methodology and 2015–2050 emission pathways under a range of socio-economic, climate policy, and pollution control scenarios

Abstract. Future trends in air pollution and greenhouse gas (GHG)emissions for China are of great concern to the community. A set of globalscenarios regarding future socio-economic and climate developments, combiningshared socio-economic pathways (SSPs) with climate forcing outcomes asdescribed by the Representative Concentration Pathways (RCPs), was createdby the Intergovernmental Panel on Climate Change (IPCC). Chinese researchers have also developed various emission scenarios by considering detailed local environmental and climate policies. However, a comprehensive scenario set connecting SSP–RCP scenarios with local policies and representing dynamic emission changes under local policies is still missing. In this work, to fill this gap, we developed a dynamic projection model, the Dynamic Projection model for Emissions in China (DPEC), to explore China'sfuture anthropogenic emission pathways. The DPEC is designed tointegrate the energy system model, emission inventory model, dynamicprojection model, and parameterized scheme of Chinese policies. The modelcontains two main modules, an energy-model-driven activity rate projectionmodule and a sector-based emission projection module. The activity rateprojection module provides the standardized and unified future energyscenarios after reorganizing and refining the outputs from the energy systemmodel. Here we use a new China-focused version of the Global ChangeAssessment Model (GCAM-China) to project future energy demand and supply inChina under different SSP–RCP scenarios at the provincial level. Theemission projection module links a bottom-up emission inventory model, theMulti-resolution Emission Inventory for China (MEIC), to GCAM-China andaccurately tracks the evolution of future combustion and production technologiesand control measures under different environmental policies. We developedtechnology-based turnover models for several key emitting sectors (e.g.coal-fired power plants, key industries, and on-road transportationsectors), which can simulate the dynamic changes in the unit/vehicle fleetturnover process by tracking the lifespan of each unit/vehicle on an annualbasis. With the integrated modelling framework, we connected five SSP scenarios(SSP1–5), five RCP scenarios (RCP8.5, 7.0, 6.0, 4.5, and 2.6), and threepollution control scenarios (business as usual, BAU; enhanced controlpolicy, ECP; and best health effect, BHE) to produce six combined emissionscenarios. With those scenarios, we presented a wide range of China's futureemissions to 2050 under different development and policy pathways. We foundthat, with a combination of strong low-carbon policy and air pollutioncontrol policy (i.e. SSP1-26-BHE scenario), emissions of major airpollutants (i.e. SO 2 , NO x , PM 2.5 , and non-methane volatile organic compounds – NMVOCs) in China willbe reduced by 34%–66% in 2030 and 58%–87% in 2050 compared to 2015. End-of-pipe control measures are more effective for reducing air pollutant emissions before 2030, while low-carbon policy will play a more important rolein continuous emission reduction until 2050. In contrast, China's emissionswill remain at a high level until 2050 under a reference scenario without activeactions (i.e. SSP3-70-BAU). Compared to similar scenarios set from theCMIP6 (Coupled Model Intercomparison Project Phase 6), our estimates ofemission ranges are much lower than the estimates from the harmonized CMIP6 emissions dataset in2020–2030, but their emission ranges become similar in the year 2050.

54 ENVIRONMENTAL SCIENCES↗

Resilience of the Electric Grid Through Trustable IoT-Coordinated Assets

The electricity grid has evolved from a physical system to a cyberphysical system with digital devices that perform measurement, control, communication, computation, and actuation. The increased penetration of distributed energy resources (DERs) including renewable generation, flexible loads, and storage provides extraordinary opportunities for improvements in efficiency and sustainability. However, they can introduce new vulnerabilities in the form of cyberattacks, which can cause significant challenges in ensuring grid resilience. We propose a framework in this paper for achieving grid resilience through suitably coordinated assets including a network of Internet of Things devices. A local electricity market is proposed to identify trustable assets and carry out this coordination. Situational Awareness (SA) of locally available DERs with the ability to inject power or reduce consumption is enabled by the market, together with a monitoring procedure for their trustability and commitment. With this SA, we show that a variety of cyberattacks can be mitigated using local trustable resources without stressing the bulk grid. Multiple demonstrations are carried out using a high-fidelity cosimulation platform, real-time hardware-in-the-loop validation, and a utility-friendly simulator.

distributed energy resources↗

Measurement and control of optical nonlinearities in dispersive dielectric multilayers

Dispersive dielectric multilayer mirrors, high-dispersion chirped mirrors in particular, are widely used in modern ultrafast optics to manipulate spectral chirps of ultrashort laser pulses. Dispersive mirrors are routinely designed for dispersion compensation in ultrafast lasers and are assumed to be linear optical components. In this work, we report the experimental characterization of an unexpectedly strong nonlinear response in these chirped mirrors. At modest peak intensities <2 TW/cm 2 —well below the known laser-induced damage threshold of these dielectric structures—we observed a strong reflectivity decrease, local heating, transient spectral modifications, and time-dependent absorption of the incident pulse. Through computational analysis, we found that the incident laser field can be enhanced by an order of magnitude in the dielectric layers of the structure. The field enhancement leads to a wavelength-dependent nonlinear absorption, that shows no signs of cumulative damage before catastrophic failure. The nonlinear absorption is not a simply two-photon process but instead is likely mediated by defects that facilitate two-photon absorption. To mitigate this issue, we designed and fabricated a dispersive multilayer design that strategically suppresses the field enhancement in the high-index layers, shifting the high-field regions to the larger-bandgap, low-index layers. This strategy significantly increases the maximum peak intensity that the mirror can sustain. However, our finding of an onset of nonlinear absorption even at ‘modest’ fluence and peak intensity has significant implications for numerous past published experimental works employing dispersive mirrors. Additionally, our results will guide future ultrafast experimental work and ultrafast laser design.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sodium Void Worth and Control Rod Worth Measurements in ZPPR 15

Sodium void worth and control rod worth were measured in Phases A, B, C and D of the ZPPR15 experimental program. Sodium voiding was simulated by replacing stainless steel cans containing sodium by empty stainless steel cans of the same sizes. The control rod worth measurements were measurements of simulated control rods (CRs) and simulated empty control rod positions (CRPs). A CRP consisted of a 2 x 2 array of drawers filled with sodium plates. A CR consisted of a 2 x 2 array of drawers containing alternating columns of boron carbide plates and sodium plates in the front 18 inches and just sodium plates in the back 18 inches. The ZPPR staff published the measured sodium void worths and control rod worths and the statistical uncertainties in the measured values. In reality, the published uncertainty for each of these measurements is only one component of the total uncertainty. There are additional contributions from uncertainties related to measurement technique, plate compositions and reproducibility. However, the dominant uncertainty for the sodium void worth and control rod worth measurements is the uncertainty in βeff which is required to convert from the natural measurement units, cents, to the calculation units, pcm or Δ/k 1 k 2 . A full uncertainty analysis was performed for the sodium void worth and control rod worth measurements. The significant uncertainties were quantified, and a total uncertainty was derived for each sodium void worth or control rod worth measurement. The ZPPR-15 experimental records were used to create detailed as-built Monte Carlo models of the sodium void worth and control rod worth configurations. These models were used to compute the sodium void worths and control rod worths. (C/E – 1) and the related uncertainty in (C/E – 1) were derived for the measured worths.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Managing Army Plug Load Equipment Energy Use: Breakroom Appliances

Breakroom equipment is the third highest energy-consuming plug load category in Army buildings. In addition to the vending machine measures described separately, improved purchasing and control measures for breakroom appliances can save the Army more than 9 million kWh and $550K per year in the building types evaluated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RCT: Module 2.06, Airborne Sampling Program/Methods [Slides]

The inhalation of radioactive particles is the largest cause of internal dose in workplace incidents. Airborne radioactivity measurements are necessary to ensure that the control measures are, and continue to be, effective. Typically, airborne radioactivity levels are maintained well below allowable levels to keep the total effective dose equivalent small.

61 RADIATION PROTECTION AND DOSIMETRY↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shedding in Large Offices

This documentation focuses on a single End-Use Savings Shape measure - thermostat control for load shedding. The thermostat control for load shedding measure applies heating and cooling temperature setpoint offsets for reducing the heating and cooling load during peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the peak window, and then adjusts the thermostat cooling and/or heating setpoints by an offset value from original schedules during the peak window to reduce the HVAC or whole building daily peak load. The measure is flexible and allows users to adjust the heating and cooling offset values respectively, but for this study, the adjustment for heating and cooling setpoints are set to -2 degrees Celsius and +2 degrees Celsius by default. The measure provides options of adding rebound control period (default 2 hours) after peak windows for the setpoints to be ramped back to default values, to prevent the system from generating higher peak demand with step changes of setpoints in post-peak periods . This measure is applicable t o large offices equipped with electric HVAC system (either electric cooling only or both electric heating and cooling), which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shedding measure demonstrates 2-5% daily peak demand reduction and 0.068% total site energy savings (3 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Lighting Control for Load Shedding

This report describes the modeling methodology for a single end-use savings shape measure - lighting control for load shedding - and briefly introduces key results. The lighting control for load shedding measure applies lighting dimming control to reduce the lighting load during the building's electricity peak window every weekday. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the predicted peak window, and then adjusts the lighting dimming level by a percentage reduction from the original schedules during the peak window to reduce the peak demand. The measure is applicable to (large, medium and small) offices, warehouses, and primary and secondary schools, which correspond to approximately 68% of the stock floor area of commercial buildings in ComStock analysis. The measure demonstrates 2%-7% daily peak demand reduction performance for applicable buildings, and 0.43% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shifting in Large Offices

This documentation focuses on a single end-use savings shape measure - thermostat control for load shifting. The thermostat control for load shifting measure applies heating and cooling temperature setpoint adjustment for pre-conditioning before the peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start time of the peak window, and then adjusts the thermostat cooling or heating setpoints by a specified offset value from original schedules to precool or preheat the space , for a specified length of time before the start of peak window, and thus shifts load in the peak window to the pre-conditioning period. The measure is flexible and allows users to adjust the heating and cooling offset values and length of pre-conditioning period, but for this study, the load shifting strategy is applied as pre-cooling only (adjusting only cooling setpoints). The default adjustment for cooling setpoints is set to -1 degrees Celsius , and the default duration of pre-cooling is 1 hour. This measure is applicable to large offices equipped with electric HVAC system, which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shifting measure demonstrates -1% daily peak demand reduction and 0% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the impact of human mobility to predict regional excess death in Ecuador

Abstract COVID-19 outbreaks have had high mortality in low- and middle-income countries such as Ecuador. Human mobility is an important factor influencing the spread of diseases possibly leading to a high burden of disease at the country level. Drastic control measures, such as complete lockdown, are effective epidemic controls, yet in practice one hopes that a partial shutdown would suffice. It is an open problem to determine how much mobility can be allowed while controlling an outbreak. In this paper, we use statistical models to relate human mobility to the excess death in Ecuador while controlling for demographic factors. The mobility index provided by GRANDATA, based on mobile phone users, represents the change of number of out-of-home events with respect to a benchmark date (March 2nd, 2020). The study confirms the global trend that more men are dying than expected compared to women, and that people under 30 show less deaths than expected, particularly individuals younger than 20 with a death rate reduction between 22 and 27%. The weekly median mobility time series shows a sharp decrease in human mobility immediately after a national lockdown was declared on March 17, 2020 and a progressive increase towards the pre-lockdown level within two months. Relating median mobility to excess deaths shows a lag in its effect: first, a decrease in mobility in the previous two to three weeks decreases excess death and, more novel, we found an increase of mobility variability four weeks prior increases the number of excess deaths.

59 BASIC BIOLOGICAL SCIENCES↗

End-Use Savings Shapes Measure Documentation: Demand Control Ventilation

This documentation focuses on a single end-use savings shape measure - Demand Control Ventilation (DCV). DCV can save energy by reducing the rate at which outdoor air (OA) is delivered during periods of less-than-design occupancy. This measure will enable DCV for air loops using applicable HVAC system types (all except dedicated outdoor air systems [DOAS], packaged systems, or that have an energy recovery ventilator [ERV]) and serving applicable space types (all except kitchens, dining areas, patient spaces, mechanical rooms, stairwells and corridors, or high exhaust space types) using model occupancy schedules to control the DCV. The measure is applicable to 72.7% of the stock floor area. As office buildings outside of California in ComStock are modeled using a single, whole-building space type, DCV is not applied to these building types. The DCV measure demonstrates 2.6% total site energy savings (119 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Low Cost SIPM Evaluation and Control Prototyping System including accurate bias voltage generation, leakage current measurement, and temperature control using Peltier cooling

We describe an electronics system to operate SIPMs in the laboratory. The system is comprised of a single channel amplifier board (SIPM Amp) and a 4-channel control board to which up to 4 SIPM Amp boards can be connected. The control board supplies a common low voltage power for the amplifiers. All channels feature individually regulated bias and Peltier power voltages, along withPt10K RTD readout. A graphical user interface allows control of the bias voltages, amplifier voltage, Peltier voltages, and also provides for readback of leakage currents and other voltages. The GUI app has a feedback loop to measure the SIPM temperature (with the PT10K) and generate correction voltages to the Peltier to regulate the temperature. The temperatures, which can be achieved by Peltier cooling depend on the thermal design of the setup, the practical limit being about 50C below ambient. The SIPM Amp. board is a small (3x5cm) PCB that has a single SIPM readout channel. The SIPM scan be surface mounted on the pcb or connected to a 2-pin 0.100" socket. The area around the SIPM footprint is thermally isolated by perforations in the PCB. The RTD is located inside the thermal break. Onboard is BV and LV filtering. The 10X amplifier is based on MiniCircuits' GALI-S66+ integrated circuit, tweaked for a 6V power. The amplifier was selected for a combination of high bandwidth, low noise, and low power. An accoupled amplifier output is connected to an SMA connector. For best operation of this inverting amplifier the output signal should be in the range of 0 to -1V.The Amplifier board is connected to the Control board with a 10-conductor 0.025" pitch ribbon cable, carrying all the services. Peltier power for currents more than 1A should use a separate 2-contact connector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗