Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement Science and Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Highly charged ion approach to measure nuclear charge radii of Fr, Ra, and Rn isotopes for precision measurements

Conventional electron scattering and muonic atom spectroscopy techniques are challenging to apply to heavy ions unless the element has at least one stable or extremely long-lived isotope. To overcome this limitation, a recently introduced method for determining nuclear charge radii relies on extreme-ultraviolet (EUV) spectroscopy of the D 1 line in highly charged Na-like ions. In this work, we present an experimental approach to measure the nuclear charge radii of isotopes of radioactive elements such as Fr, Ra, and Rn using this method at TRIUMF’s Ion Trap for Atomic and Nuclear Science (TITAN) instrument, located at the ISAC radioactive beam facility. We also explore the potential of using Na-like D 2 lines in the soft x-ray region for future measurements.

Electron beam ion trap↗

Atmospheric Radiation Measurement (ARM) airborne field campaign data products between 2013 and 2018

Airborne measurements are pivotal for providing detailed, spatiotemporally resolved information about atmospheric parameters and aerosol and cloud properties, thereby enhancing our understanding of dynamic atmospheric processes. For 30 years, the US Department of Energy (DOE) Office of Science supported an instrumented Gulfstream 1 (G-1) aircraft for atmospheric field campaigns. Data from the final decade of G-1 operations were archived by the Atmospheric Radiation Measurement (ARM) Data Center and made publicly available at no cost to all registered users. To ensure a consistent data format and to improve the accessibility of the ARM airborne data, an integrated dataset was recently developed covering the final 6 years of G-1 operations (2013 to 2018, https://doi.org/10.5439/1999133; Mei and Gaustad, 2024). The integrated dataset includes data collected from 236 flights (766.4 h), which covered the Arctic, the US Southern Great Plains (SGP), the US West Coast, the eastern North Atlantic (ENA), the Amazon Basin in Brazil, and the Sierras de Córdoba range in Argentina. These comprehensive data streams provide much-needed insight into spatiotemporal variability in the thermodynamic quantities and aerosol and cloud properties for addressing essential science questions in Earth system process studies. This paper describes the DOE ARM merged G-1 datasets, including information on the acquisition, data collection challenges and future potentials, and quality control processes. It further illustrates the usage of this merged dataset to evaluate the Energy Exascale Earth System Model (E3SM) with the Earth System Model Aerosol–Cloud Diagnostics (ESMAC Diags) package.

54 ENVIRONMENTAL SCIENCES↗

Passive Temperature Sensors for Nuclear Applications

In April 2007, the Department of Energy (DOE) designated the Advanced Test Reactor (ATR) a National Scientific User Facility (NSUF) to advance US leadership in nuclear science and technology. By attracting new users from universities, laboratories, and industry, this program supports basic and applied nuclear research to help address the nation's energy security needs. In support of this program, the Idaho National Laboratory (INL) established in-house capabilities to develop, fabricate, test, and qualify new and enhanced temperature sensors for irradiation testing. This effort is continuing today through the DOE?s Advanced Sensors and Instrumentation (ASI) program. Although most efforts emphasize sensors capable of providing real-time data, selected tasks have been completed to enhance passive sensors for irradiations where instrumentation leads cannot be included. These sensors include silicon carbide (SiC) monitors, melt wires and the sublime temperature monitor. SiC monitors are available to detect peak irradiation temperatures between 200°C and 800°C in reactor locations where instrumentation leads cannot be used. SiC monitors may be evaluated using specialized equipment installed at INL?s Measurement Sciences Laboratory (MSL). A melt wire inventory is also maintained at MSL. This inventory contains wires for specific use in irradiation experiments ranging in temperatures from 30°C to 1500°C. Melt wires and SiC monitors have had decades of research and application. Recent research has produced a passive monitor known as the sublime temperature monitor. This passive sensor has the capability of recording temperature gradients. This paper will discuss passive temperature sensors currently being researched and implemented under the ASI program.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron detector development for high-rate neutron reflectometry at the Second Target Station of Oak Ridge National Laboratory

The Second Target Station (STS) at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) is expected to produce a neutron source that is the brightest in the world, having a significantly higher peak brightness compared to the First Target Station (FTS), where the reflectometry instruments already fall short of being able to handle the highest available flux by a factor of ~100. The neutron reflectometers at the SNS FTS are not suitable for the reflectometers planned for the SNS STS because of its unprecedentedly high peak brightness and the already limited capabilities of these instruments at high count rates. Furthermore, the high rate instruments that are now under development are expected to underperform with regard to gamma sensitivity, meaning that signal-to-noise will be reduced and they will be unable to measure weaker reflectance phenomena in the presence of the significant prompt gamma flash at SNS. To address these challenges, we conducted research to advances associated instruments, techniques, and capabilities for the SNS STS reflectometers. More specifically, we investigated the development of a scalable, 2-D positive-sensitive, pixelated, scintillator-based neutron detector module based on a newly developed scintillator. The work has potential for impact on future neutron reflectometry instruments and neutron science performed at the SNS STS. In particular, the improved background rejection capability of the developed detector could extend the available experimental dynamic Q range, allowing it to measure weak reflectance phenomena.

reflectometry, radiation instrumentation, neutron ↗

Proton discrimination in CLYC for fast neutron spectroscopy

The Cs 2 LiYCl 6 :Ce (CLYC) elpasolite scintillator is known for its response to fast and thermal neutrons along with good γ-ray energy resolution. While the 35 Cl(n,p) reaction has been identified as a potential means for CLYC-based fast neutron spectroscopy in the absence of time-of-flight (TOF), previous efforts to functionalize CLYC as a fast neutron spectrometer have been thwarted by the inability to isolate proton interactions from 6 Li(n,α) and 35 Cl(n,α) signals. This work introduces a new approach to particle discrimination in CLYC for fission spectrum neutrons using a multi-gate charge integration algorithm that provides excellent separation between protons and heavier charged particles. Neutron TOF data were collected using a 252 Cf source, an array of EJ-309 organic liquid scintillators, and a 6 Li-enriched CLYC scintillator outfitted with fast electronics. Modal waveforms were constructed corresponding to the different reaction channels, revealing significant differences in the pulse characteristics of protons and heavier charged particles at ultrafast, fast, and intermediate time scales. These findings informed the design of a pulse shape discrimination algorithm, which was validated using the TOF data. This study also proposes an iterative subtraction method to mitigate contributions from confounding reaction channels in proton and heavier charged particle pulse height spectra, opening the door for CLYC-based fast neutron and γ-ray spectroscopy while preserving sensitivity to thermal neutron capture signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual Design of Neutron Sensor Qualification Device

The Advanced Sensors and Instrumentation Program at Idaho National Laboratory has been formulating strategies to qualify sensors for use in nuclear environments, particularly in irradiation experiments and advanced reactors. When qualifying neutron sensors for use in high-temperature environments, the wide range of neutron flux levels and representative energy spectra presents significant challenges. This paper discusses the development of the Neutron Sensor Qualification Device (NQD), which is designed to test neutron sensors in high temperature controlled environments with known neutron spectra, addressing the spatial and spectral complexities of neutron fluxes in reactor cores. The proposed NQD will be situated in the exposure room at the Armed Forces Radiobiology Research Institute, thus affording a unique capability to expose sensors to high neutron and gamma fluxes. To achieve thermal control, the device will utilize a radiation-hardened tube furnace, accommodating multiple sensors and neutron activation dosimetry wires. Titanium, iron, and cobalt dosimeter wires are chosen from the American Society for Testing and Materials and International Reactor Dosimetry and Fusion File libraries as references for providing energy-dependent fluence measurements. The design ensures precise sensor positioning to minimize mutual shielding and flux perturbation, which are evaluated via Monte Carlo N particle Transport Code (MCNP) simulations. These simulations have informed the development of guidelines on sensor placement within the NQD. The NQD is essential to the qualification of neutron sensors for advanced reactor technologies. It enables controlled testing of a statistically significant number of sensors, thereby supporting assessments of sensor performance across various neutron flux levels and temperatures. This paper highlights the detailed planning for the NQD prototype, along with its inaugural irradiation (scheduled for fiscal year [FY] 2025). The results from this initial testing will be fundamental in evaluating the device’s performance and establishing measurement uncertainty for in-pile neutron sensor measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Non-Science Grade DESI CCDs and Creating Additional ICARUS Monitoring Metrics for Data Quality

DESI, otherwise known as the Dark Energy Spectroscopic Instrument, is an astronomical project measuring millions of optical spectra to characterize Dark Energy. The survey has been running for 3 years. My work delves into the data taking/analysis side of the DESI CCDs (Charge-Coupled Devices) which will help in swapping out broken CCDs on the instrument. Additionally, I worked on making new metrics for ICARUS, Imaging Cosmic and Rare Underground Signals for their monitoring of run data. This paper will talk about the types of characterizations done for DESI and additional metrics for data quality and tools used for ICARUS monitoring.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Improved Beam Position Monitor for Scorpius and the DARHT Multi-Pulse Test Line

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). A frequently used BPM detector is the B-dot loop, which generates a signal from the EMF generated by the time varying magnetic flux through the loop. We have developed a second generation BPM that avoids previously observed diffusion effects in earlier stainless steel through the use of exceptionally high conductivity copper alloy for its construction.

43 PARTICLE ACCELERATORS↗

Assessment of Thin Plastic Scintillation Detectors for Beta-Particle Measurements at the Advanced Test Reactor Critical Facility

The Fission Wire Measurement System is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical facility. The Advanced Test Reactor Critical facility is an open-pool, low-power test reactor used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in the Advanced Test Reactor. Power distribution measurements in ATR-C use uranium-aluminum wires that are distributed throughout the core to validate simulation and modeling results. These measurements require from 340 to 1500 wires to be irradiated and measured within a 12-hour window. The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. The gas flow detectors are of a custom design for this detector system that use methane gas with a large anode wire compared to modern proportional counters. These detectors, which are nearly 60 years old are irreplaceable. The measurements from these gas detectors are affected by the gas flow rate, atmospheric and line pressure, and are very sensitive to the applied high voltage. Recent improvements have been made to the control and data acquisition system, but the detectors have remained the same. The nature of the measurement of the fission product decay activity is such that the energy spectrum of the signal is changing with time. Thin, 250-um thick, plastic scintillators were commercially obtained as a potential replacement for the gas flow detectors. The original calibration of the uranium-aluminum fission wires was conducted in 1965 using a series of irradiations of gold foils and the wires in a well-characterized thermal neutron field. These measurements provided a time-dependent fission rate conversion factor from the gold foil data to calibrate the fission wires based on the response from the 2-pi proportional gas detectors. Transitioning to the new detectors requires qualification and testing. The sensitivity of the scintillators to changes in the energy spectrum of the fission wires and translation of the calibration factor have been completed. These measurements indicated that the sensitivity of the scintillators over time changes at a different rate than the sensitivity of the gas flow detectors. However, the inverse activity of measurements of both detector types is linear with time. Initial results indicate that the scintillator detectors will be a sufficient replacement for the gas detectors with minor adjustments to the fission rate conversion factor. Replacement of the detectors will improve the fission wire measurements and provide a more stable and reliable measurement system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Initial Findings in Qualifying the Instrument Thimble 11 Position in the Advanced Test Reactor Critical

The Advanced Test Reactor (ATR) is a versatile nuclear research reactor located at the Idaho National Laboratory (INL) in Eastern Idaho, United States of America. It is one of the most powerful and flexible research reactors in the world and is primarily used for materials testing, isotope production and basic nuclear science research. The ATR is a light-water-cooled, beryllium-moderated reactor with a nominal thermal power capacity of 250 MW utilizing specially designed fuel, arranged in a serpentine pattern to create 9 flux traps. The special design of ATR allows for the neutron flux within each of the flux traps providing flexibility for experiments, programs and allowing experiments with different dose requirements to be irradiated simultaneously. The Advance Test Reactor Critical (ATRC) is a full-scale replica of the ATR core but is housed in a pool instead of a pressure vessel. ATRC is usually operated at less than 600 watts [1]. There are 12 dry instrument thimbles located around the outside of the core tank where a variety of measurement equipment is housed to facilitate reactor operations. Currently Instrument Thimble 11 (IT-11) is not utilized in ATR or ATRC. A range of measurements is ongoing to qualify IT-11 as a test platform for nuclear instrumentation research, development and further experimentation.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Special Nuclear Geometric Modeling

This report is a summary of our summer interns project that focused on investigating the usefulness of the Gamma Detector Response and Analysis Software (GADRAS) into the Material Control & Accountability (MC&A) Measurements Team. The project's findings highlight the advantages of using GADRAS and demonstrate its value in improving the MC&A Measurements Team's analytical capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FPMS_XPeRT_INL_Poster

As nuclear energy expands and experimental programs increasingly rely on the facilities at Idaho National Laboratory (INL) for reactor and fuel testing, research capabilities must also expand to meet these demands. A new Fission Product Monitoring System (FPMS) has been deployed at the Advanced Test Reactor (ATR) at the Auxiliary Lead-out Experiment (ALE) House to support this expanding fuel testing mission. By tracking gaseous fission products releases from test fuel in near real-time, release rates, calculated from FPMS data, can be used to characterize the effectiveness of fuel cladding, especially for Tri-structural Isotropic (TRISO) fuel concepts. The new iteration of the FPMS supports up to 14 fission product monitors for online fission-product tracking via gamma-ray spectroscopy of the experiment’s effluent gas. Each monitor consists of a nominally 10% HPGe detector housed in a copper-lined lead shield with a warm gas trap. The new system features gamma-ray count rate information with a five-second temporal resolution and provides isotopic activity every five minutes, capable of resolving multiple overlapping fission product releases over a broad range of activities in near real-time. This work includes data from ATR cycle 175D data to demonstrate these capabilities. The hourly resolution data shows general trends and significant releases over the cycle, while the 5-minute resolution data allows for a more detailed examination of events due to unexpected particle releases.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

DICER: A new instrument at LANSCE to constrain neutron capture rates on radionuclides

With very few exceptions, direct measurements of neutron capture rates on radionuclides have not been possible. A number of indirect methods have been pursued such as the surrogate method, the γ-ray strength function method, the Oslo method and the β-Oslo method. Substantial effort has been devoted to quantify the usually large systematic errors that accompany the results from these techniques. A new instrument has been developed at the Los Alamos Neutron Science Center (LANSCE) to provide more accurate data on several radionuclides relevant to nuclear criticality safety, radiochemical diagnostics, astrophysics, nuclear forensics and nuclear security, by measuring the transmission of neutrons through radioactive samples and studying resonance properties. The Device for Indirect Capture on Radionuclides (DICER) and associated radionuclide production at the Isotope Production Facility (IPF), both at LANSCE, as well radioactive sample fabrication, have been under development the last few years. A description of the new apparatus, data on a few mid-weight stable isotopes and efforts on radionuclide measurements will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the Dark Energy Spectroscopic Instrument (DESI) and Year 1 Cosmology results

The Dark Energy Spectroscopic Instrument (DESI) will measure the effect of dark energy on the expansion of the universe. It will obtain optical spectra for tens of millions of galaxies and quasars, constructing a 3D map spanning the nearby universe to 11 billion light years. The DESI Survey is being conducted on the Mayall 4-meter telescope at Kitt Peak National Observatory. DESI is supported by the Department of Energy Office of Science to perform this Stage IV dark energy measurement using baryon acoustic oscillations and other techniques that rely on spectroscopic measurements. I will discuss the status of the Dark Energy Spectroscopic Instrument (DESI) survey and present our Year 1 Baryon Acoustic Oscillation measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗