Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

New measurement techniques for gear-changing research using DESIREE

In this work we cover some of the newer techniques developed to measure the effects of a gear changing system maintained in DESIREE at Stockholm University. Gear-changing is a collider synchronization method where two rings with different harmonic numbers in them maintain collisions through different velocities, pathlengths or a combination of the two. This system has been demonstrated using the low energy ion collider DESIREE at Stockholm university. We have not only continued our previous methods of studying the beam using a repeating pattern technique where one bucket in each ring is intentionally left empty, but we now also use recently installed pickups outside of the merger region to study the beams separately while they collide.

Accelerator Physics↗

A measurement technique to determine the calibration accuracy of an electromagnetic tracking system to radiation isocenter

Purpose: To present and characterize a measurement technique to quantify the calibration accuracy of an electromagnetic tracking system to radiation isocenter.Methods: This technique was developed as a quality assurance method for electromagnetic tracking systems used in a multi-institutional clinical hypofractionated prostate study. In this technique, the electromagnetic tracking system is calibrated to isocenter with the manufacturers recommended technique, using laser-based alignment. A test patient is created with a transponder at isocenter whose position is measured electromagnetically. Four portal images of the transponder are taken with collimator rotations of 45° 135°, 225°, and 315°, at each of four gantry angles (0°, 90°, 180°, 270°) using a 3 × 6 cm{sup 2} radiation field. In each image, the center of the copper-wrapped iron core of the transponder is determined. All measurements are made relative to this transponder position to remove gantry and imager sag effects. For each of the 16 images, the 50% collimation edges are identified and used to find a ray representing the rotational axis of each collimation edge. The 16 collimator rotation rays from four gantry angles pass through and bound the radiation isocenter volume. The center of the bounded region, relative to the transponder, is calculated and then transformed to tracking system coordinates using the transponder position, allowing the tracking system's calibration offset from radiation isocenter to be found. All image analysis and calculations are automated with inhouse software for user-independent accuracy. Three different tracking systems at two different sites were evaluated for this study.Results: The magnitude of the calibration offset was always less than the manufacturer's stated accuracy of 0.2 cm using their standard clinical calibration procedure, and ranged from 0.014 to 0.175 cm. On three systems in clinical use, the magnitude of the offset was found to be 0.053 ± 0.036, 0.121 ± 0.023, and 0.093 ± 0.013 cm.Conclusions: The method presented here provides an independent technique to verify the calibration of an electromagnetic tracking system to radiation isocenter. The calibration accuracy of the system was better than the 0.2 cm accuracy stated by the manufacturer. However, it should not be assumed to be zero, especially for stereotactic radiation therapy treatments where planning target volume margins are very small.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of measurement techniques and sorption of radium-226 in low and high salinity aqueous samples

Human activities have the potential to redistribute radium (Ra) in the marine environment in a manner that may necessitate monitoring or management of subsequent human or environmental exposures. There is therefore a need to identify accurate and accessible techniques for Ra measurement in high salinity samples and to describe the distribution of Ra in estuarine and marine environments, but most efforts in these areas have focused on low salinity matrices. In addition, rapid and reliable measurements are crucial for time-sensitive samples such as short-lived isotopes or emergency situations. The objective of this study is to describe the limits of detection, cost, and relative ease for measurement of Ra in both low and high salinity aqueous samples via three analytical methods: liquid scintillation counting (LSC), high purity germanium (HPGe) gamma spectrometry, and inductively coupled plasma mass spectrometry (ICP-MS). To contextualize these measurements for real-world scenarios, the partitioning of 226 Ra to substrates relevant to the marine environment was also characterized. Although HPGe detection with solid phase extraction had the lowest limit of detection for low salinity samples (0.27 Bq L −1 ), poor 226 Ra recovery for high salinity samples and high materials costs make this method prohibitive for many users. Limits of detection for high salinity samples were lower for LSC (1.28 Bq L −1 ) than for ICP-MS without dilution (11.4 Bq L −1 ), but significant and unexpected degradation of the high salinity LSC standards was observed after six months. Furthermore, our preferred measurement method for high salinity Ra samples is ICP-MS with sample dilution as necessary to reduce matrix effects.

07 ISOTOPE AND RADIATION SOURCES↗

Superpartner Mass Measurement Technique using 1D Orthogonal Decompositions of the Cambridge Transverse Mass Variable M{sub T2}

We propose a new model-independent technique for mass measurements in missing energy events at hadron colliders. We illustrate our method with the most challenging case of a single-step decay chain. We consider inclusive same-sign chargino pair production in supersymmetry, followed by leptonic decays to sneutrinos {chi}{sup +{chi}+{yields}}l{sup +}l{sup '+{nu}}-tilde{sub l{nu}}-tilde{sub l}{sup '} and invisible decays {nu}-tilde{sub l{yields}{nu}l{chi}}-tilde{sub 1}{sup 0}. We introduce two one-dimensional decompositions of the Cambridge M{sub T2} variable: M{sub T2{sub |{sub |}}} and M{sub T2{sub p{sub e{sub r{sub p{sub e{sub n{sub d{sub i{sub c{sub u{sub l{sub a{sub r}}}}}}}}}}}}}}), on the direction of the upstream transverse momentum P-vector{sub T} and the direction orthogonal to it, respectively. We show that the sneutrino mass M{sub c} can be measured directly by minimizing the number of events N(M-tilde{sub c}) in which M{sub T2} exceeds a certain threshold, conveniently measured from the end point M{sub T2{sub perpendicular}}{sup max}(M-tilde{sub c}).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of Ionic Conductivity and Electrode Polarization at Low Temperatures on 8YSZ by a DC Technique

Measurement of ionic conductivity and electrode polarization resistance on a 8YSZ sample with platinum paste electrodes was conducted using a DC method with high input impedance meters over a temperature range from 119°C to 589°C. Over the entire temperature range, the meter resistance was much larger than the sample resistance including the polarization resistance. At lower temperatures, a faraday cage was used to minimize noise. The measured polarization resistance was also verified using electrochemical impedance spectroscopy. Ionic conductivity of 8YSZ exhibited Arrhenius behavior with an activation energy of ~1.1 eV, in good agreement with the literature. In the low current regime, electrode kinetics could be described by the linearized form of the Butler-Volmer equation. At higher current densities, electrode kinetics exhibited Tafel behavior. The polarization resistance exhibited Arrhenius behavior with the activation energy ranging between 1.05 and 1.27 eV. The present work shows that electrode polarizations can be investigated using a DC method. The approach may allow study of different electrodes in various atmospheres using one sample.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

UNESE Argon-39 Measurement Techniques: Developing an above-ground Argon-39 Measurement Capability

The Underground Nuclear Explosion Signatures Experiment (UNESE) sought to use 37 Ar as a tracer for measuring noble-gas migration in the soil surrounding historic Underground Nuclear Explosions (UNE). One unexpected observation was the presence of the much longer-lived isotope 39 Ar from historic UNEs. Quantifying the activity of 39 Ar proved difficult due to the lack of capability to measure significantly-above-background levels of 39 Ar and a general discomfort to repeatedly expose Ultra-Low-Background Proportional Counters (ULBPCs) to significant radioactivity. Because the whole-air samples collected for the 37 Ar tracer measurement were already being measured on the above-ground argon capability, it was decided to expand that capability to include 39 Ar. This document describes the efforts required to achieve quantitative reporting of the 39 Ar backgrounds measured during experiments at the sites of the historic Barnwell and Disko Elm UNEs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of measurement technique for carbon atoms employing vacuum ultraviolet absorption spectroscopy with a microdischarge hollow-cathode lamp and its application to diagnostics of nanographene sheet material formation plasmas

This study describes the development of a compact measurement technique for absolute carbon (C) atom density in processing plasmas, using vacuum ultraviolet absorption spectroscopy (VUVAS) employing a high-pressure CO{sub 2} microdischarge hollow-cathode lamp (C-MHCL) as the light source. The characteristics of the C-MHCL as a resonance line source of C atoms at 165.7 nm for VUVAS measurements of the absolute C atom density are reported. The emission line profile of the C-MHCL under typical operating conditions was estimated to be the Voigt profile with a DELTAnu{sub L}/DELTAnu{sub D} value of 2.5, where DELTAnu{sub L} is the Lorentz width and DELTAnu{sub D} is the Doppler width. In order to investigate the behavior of C and H atoms in the processing plasma used for the fabrication of two-dimensional nanographene sheet material, measurements of the atom densities were carried out using the VUVAS technique. The H atom density increased with increasing pressure, while the C atom density was almost constant at 5x10{sup 12} cm{sup -3}. The density ratio of C to H atoms in the plasma was found to influence the morphology of carbon nanowalls (CNWs). With increasing H/C density ratio, the growth rate decreased and the space between the walls of the CNWs became wider.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Characterization of uranium bearing material using x-ray fluorescence and direct gamma-rays measurement techniques

Uranium ore can be easily detected due to various gamma-ray energies emitted from uranium daughters particularly from {sup 238}U daughters such as {sup 214}Bi, {sup 214}Pb and {sup 226}Ra. After uranium is extracted from uranium ore, only low energy gamma-rays emitted from {sup 235}U may be detected if the detector is placed in close contact to the specimen. In this research, identification and characterization of uranium bearing materials is experimentally investigated using direct measurement of gamma-rays from {sup 235}U in combination with the x-ray fluorescence (XRF) technique. Measurement of gamma-rays can be conducted by using high purity germanium (HPGe) detector or cadmium telluride (CdTe) detector while a {sup 57}Coradioisotope-excited XRF spectrometer using CdTe detector is used for elemental analysis. The proposed technique was tested with various uranium bearing specimens containing natural, depleted and enriched uranium in both metallic and powder forms.

07 ISOTOPE AND RADIATION SOURCES↗

Measurement techniques using the electron beam profile scanner at the Fermilab Main Injector

This work presents techniques for non-invasive transverse profile measurements of high-intensity proton beams using an Electron Beam Profile Scanner (EBPS). The EBPS utilizes low-energy electrons as a probe to analyze the transverse size of proton beams, allowing for potential analysis on a single-bunch basis. Recent upgrades to the Fermilab Main Injector have enhanced beam power on target to 1 MW, with future developments targeting 2 MW. The higher beam power has increased the demand for non-invasive diagnostics, as invasive methods can disrupt operations.The techniques presented include 1) the slow scan technique, which serves as a proof of concept for the probe beam, 2) the one-shot scan technique for measuring horizontal beam profiles, and 3) the raster scan technique for analyzing horizontal beam profiles as a function of the longitudinal distribution of the beam. The profiles obtained will be crucial for studying and understanding instabilities in high-power, high-intensity proton beams. This will contribute to optimizing the operation of high-power proton accelerators by minimizing beam loss, activation, and damage to both the diagnostics and the accelerator components.

Mwaniki, Matilda [IIT, Chicago]↗

Experimental study on the startup of the annular wick type heat pipe using fiber optical temperature measurement technique

This study used optical fiber-distributed temperature sensors to measure the internal and external temperature distributions of a water-cooled heat pipe. The sensor technology used in this study is fiber optical distributed temperature sensing, a distributed sensing technique based on the naturally occurring Rayleigh backscatter in optical fibers. This measurement technique provides maximum spatial resolution for static and semi-static applications. Using this sensor, the temperature distribution of the heat pipe's internal, external, vapor core, and the wick was measured with a spatial resolution of 0.65 mm, a sampling frequency of 40 Hz, and a temperature resolution of 0.1 °C. Through the measured temperature distribution database, the starting phenomenon, the effective length trend, and the limitation onset were observed. From the results, it is found that a high-temperature peak appears at the evaporator if a high initial power (75 W) is imposed on the heat pipe, even after the heat pipe approaches the normal operating status. The peak is not observed in a slower startup (30 W initial power then slowly increased to 75 W). It is also found that the temperature distributions and effective condenser length of the heat pipe highly depend on the cooling conditions. There are variations in the temperature according to the radial direction of the horizontal heat pipe due to gravity. In conclusion, lead and lag of the temperature evolution were observed at the onset of the operating limitations.

42 ENGINEERING↗

An inkjet vision measurement technique for high-frequency jetting

Inkjet technology has been used as manufacturing a tool for printed electronics. To increase the productivity, the jetting frequency needs to be increased. When using high-frequency jetting, the printed pattern quality could be non-uniform since the jetting performance characteristics including the jetting speed and droplet volume could vary significantly with increases in jet frequency. Therefore, high-frequency jetting behavior must be evaluated properly for improvement. However, it is difficult to measure high-frequency jetting behavior using previous vision analysis methods, because subsequent droplets are close or even merged. In this paper, we present vision measurement techniques to evaluate the drop formation of high-frequency jetting. The proposed method is based on tracking target droplets such that subsequent droplets can be excluded in the image analysis by focusing on the target droplet. Finally, a frequency sweeping method for jetting speed and droplet volume is presented to understand the overall jetting frequency effects on jetting performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis Background & Noise in Stretched Wire Alignment Technique Measurements

The Stretched-Wire Alignment Technique (SWAT) is one method of magnet alignment for linear induction accelerators. The applications of SWAT have been implemented for aligning solenoid magnets on the Scorpius linear induction accelerator which will be sited at the Nevada National Security Site and the Flash X-Ray (FXR) linear induction accelerator at Lawrence Livermore National Laboratory’s Contained Firing Facility. This article describes both systematic (repeatable) and random sources of background and noise as well as practical ways to eliminate or reduce them to acceptable levels. Systematic sources include reflections from wire ends, rapid sag due to ohmic heating of the wire, magnetic materials, and shot rate. Random sources include air currents, vibration of nearby equipment, mechanical stability of test equipment, and the instruments used to measure the wire motion. Mitigations include curve fitting and adaptive noise signal cancellation, and mechanical damping. Finite Element Analysis (FEA) was used to identify and resolve a repeatable wire vibration frequency interfering with the signal resolution. Two stretched wire alignment technique set ups from Sandia National Labs and Lawrence Livermore National Lab have shown background noise sources and ways of mitigating them by either analysis methods or change of mechanical configuration. Conclusions that were drawn included the severe sensitivity of the deflection to even small external interferences of the SWAT wire such that it requires attention to detail in mechanical set up and analysis.

Linear Inductive Accelerator↗

Gas-mapping 3D imager measurement techniques and method of data processing

Measurement approaches and data analysis methods are disclosed for combining 3D topographic data with spatially-registered gas concentration data to increase the efficiency of gas monitoring and leak detection tasks. Here, the metric for efficiency is defined as reducing the measurement time required to achieve the detection, or non-detection, of a gas leak with a desired confidence level. Methods are presented for localizing and quantifying detected gas leaks. Particular attention is paid to the combination of 3D spatial data with path-integrated gas concentration measurements acquired using remote gas sensing technologies, as this data can be used to determine the path-averaged gas concentration between the sensor and points in the measurement scene. Path-averaged gas concentration data is useful for finding and quantifying localized regions of elevated (or anomalous) gas concentration making it ideal for a variety of applications including: oil and gas pipeline monitoring, facility leak and emissions monitoring, and environmental monitoring.

Thorpe, Michael↗

A surface work function measurement technique utilizing constant deflected grazing electron trajectories: Oxygen uptake on Cu(001)

We report on the application of a novel nondestructive in-vacuum technique for relative work function measurements, employing a grazing incidence electron deflection above a sample with a planar surface. Two deflected electron beam detectors are used as a position sensitive detector to control feedback to the sample potential as the sample work function changes. With feedback the sample potential exactly follows the surface sample-size averaged work function variation, so that the deflected beam trajectory remains stable. We also discuss methods to optimize the initial electron trajectories for this method, so as to minimize unwanted effects such as from uncontrolled external magnetic fields. As the electron beam does not impinge on the surface in this new technique electron induced desorption, ionization, dissociation, and/or decomposition is not induced at the interface. Importantly also the technique allows for free access to the surfaces enabling simultaneous deposition/evaporation and/or application of other surface characterization methods. We demonstrate its application in concurrent measurements of helium atom reflectivity and work function changes taking place during molecular oxygen exposure of a Cu(001) surface. A work function measurement sensitivity and stability is demonstrated at {approx}10 mV at a sampling rate of 1 Hz and after application of an {approx}7 s smoothing routine. In comparison to the helium atom reflectivity measurements, the work function measurements are more sensitive to the initial O uptake, and less so to the final coverage variations and possible surface reordering at higher O coverages.

43 PARTICLE ACCELERATORS↗

An X-band waveguide measurement technique for the accurate characterization of materials with low dielectric loss permittivity

In this work, we present a new X-band waveguide (WR90) measurement method that permits the broadband characterization of the complex permittivity for low dielectric loss tangent material specimens with improved accuracy. An electrically long polypropylene specimen that partially fills the cross-section is inserted into the waveguide and the transmitted scattering parameter (S{sub 21}) is measured. The extraction method relies on computational electromagnetic simulations, coupled with a genetic algorithm, to match the experimental S{sub 21} measurement. The sensitivity of the technique to sample length was explored by simulating specimen lengths from 2.54 to 15.24 cm, in 2.54 cm increments. Analysis of our simulated data predicts the technique will have the sensitivity to measure loss tangent values on the order of 10{sup −3} for materials such as polymers with relatively low real permittivity values. The ability to accurately characterize low-loss dielectric material specimens of polypropylene is demonstrated experimentally. The method was validated by excellent agreement with a free-space focused-beam system measurement of a polypropylene sheet. This technique provides the material measurement community with the ability to accurately extract material properties of low-loss material specimen over the entire X-band range. This technique could easily be extended to other frequency bands.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗