Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Designing a minimum-functionality neutron and gamma measurement instrument with a focus on authentication

During the design and construction of the Next-Generation Attribute-Measurement System, which included a largely commercial off-the-shelf (COTS), nondestructive assay (NDA) system, we realized that commercial NDA equipment tends to include numerous features that are not required for an attribute-measurement system. Authentication of the hardware, firmware, and software in these instruments is still required, even for those features not used in this application. However, such a process adds to the complexity, cost, and time required for authentication. To avoid these added authenticat ion difficulties, we began to design NDA systems capable of performing neutron multiplicity and gamma-ray spectrometry measurements by using simplified hardware and software that avoids unused features and complexity. This paper discusses one possible approach to this design: A hardware-centric system that attempts to perform signal analysis as much as possible in the hardware. Simpler processors and minimal firmware are used because computational requirements are kept to a bare minimum. By hard-coding the majority of the device's operational parameters, we could cull large sections of flexible, configurable hardware and software found in COTS instruments, thus yielding a functional core that is more straightforward to authenticate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Qualification of Mitutoyo RA-2200 Roundness Tester Measuring Instrument for Clad Vent Set Cup Roundness and Flatness Inspections

Roundness (or circularity) and flatness measurements are made as part of the dimensional inspection process to certify that iridium alloy Clad Vent Set (CVS) cups meet the dimensional requirements of Iridium Alloy Cup Drawing M2D920101A005, Rev. 4 (see Figure 1). A Mahr Federal (Providence, RI) MarForm MMQ 400 Formtester is specified in the cup inspection Procedure GPHS-C-3624/25, Rev. 25 for roundness (dimension 16) and flatness (dimension 17). The Mahr Federal (Providence, RI) MarForm MMQ 400 Formtester stopped functioning in 2019. A new Mitutoyo RA-2200 Roundness Tester was purchased to replace the MMQ 400. Evaluations were conducted to qualify the new RA-2200 for CVS cup dimensional inspection work. The criterion for qualification was to ensure that the new RA-2200 instrument would yield roundness and flatness inspection results equivalent to or better than the predecessor MMQ 400 instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High precision tilt stage as a key element to a universal test mirror for characterization and calibration of slope measuring instruments

The ultimate performance of surface slope metrology instrumentation, such as long trace profilers and auto-collimator based deflectometers, is limited by systematic errors that are increased when the entire angular range is used for metrology of significantly curved optics. At the ALS X-Ray Optics Laboratory, in collaboration with the HZB/BESSY-II and PTB (Germany) metrology teams, we are working on a calibration method for deflectometers, based on a concept of a universal test mirror (UTM) [V. V. Yashchuk et al., Proc. SPIE 6704, 67040A (2007)]. Potentially, the UTM method provides high performance calibration and accounts for peculiarities of the optics under test (e.g., slope distribution) and the experimental arrangement (e.g., the distance between the sensor and the optic under test). At the same time, the UTM calibration method is inherently universal, applicable to a variety of optics and experimental arrangements. In this work, we present the results of tests with a key component of the UTM system, a custom high precision tilt stage, which has been recently developed in collaboration with Physik Instrumente, GmbH. The tests have demonstrated high performance of the stage and its capability (after additional calibration) to provide angular calibration of surface slope measuring profilers over the entire instrumental dynamic range with absolute accuracy better than 30 nrad. The details of the stage design and tests are presented. We also discuss the foundation of the UTM method and calibration algorithm, as well as the possible design of a full scale UTM system.

47 OTHER INSTRUMENTATION↗

Correcting systematic bias and instrument measurement drift with mzRefinery

Systematic bias in mass measurement adversely affects data quality and negates the advantages of high precision instruments. We introduce the mzRefinery tool into the ProteoWizard package for calibration of mass spectrometry data files. Using confident peptide spectrum matches, three different calibration methods are explored and the optimal transform function is chosen. After calibration, systematic bias is removed and the mass measurement errors are centered at zero ppm. Because it is part of the ProteoWizard package, mzRefinery can read and write a wide variety of file formats. In conclusion, we report on availability; the mzRefinery tool is part of msConvert, available with the ProteoWizard open source package at http://proteowizard.sourceforge.net/

47 OTHER INSTRUMENTATION↗

Uncertainty analysis of signal deconvolution using a measured instrument response function

A common analysis procedure minimizes the ln-likelihood that a set of experimental observables matches a parameterized model of the observation. The model includes a description of the underlying physical process as well as the instrument response function (IRF). Here, we investigate the National Ignition Facility (NIF) neutron time-of-flight (nTOF) spectrometers, the IRF is constructed from measurements and models. IRF measurements have a finite precision that can make significant contributions to the uncertainty estimate of the physical model’s parameters. Finally, we apply a Bayesian analysis to properly account for IRF uncertainties in calculating the ln-likelihood function used to find the optimum physical parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparison and Analysis of Instruments Measuring Plane-of-Array Irradiance for One-Axis Tracking Systems: Preprint

A variety of sensors are studied on a one-axis tracking surface and a horizontal surface in Golden, Colorado, and Eugene, Oregon. This is the first year of a long-term study that will look at not only a comparison between the instruments but also the longer-term degradation in calibration and/or performance. Initially, results from each location will be analyzed, and then results will be compared and contrasted between the two locations. A quick comparison at Eugene indicates that reference solar cells seem to compare better against a secondary standard pyranometer on a one-axis tracker than photodiode-based pyranometers. More study is needed to characterize and confirm this finding.

14 SOLAR ENERGY↗

A Traditional Look at SPE Phase 1 Surface Seismic Data: Far-Field Instruments, Measurements, and Analysis

We visually examined surface seismic data from the Source Physics Experiment (SPE) Phase-1 chemical explosions in preparation for waveform analysis and interpretation. Recording stations included far-field (near source) geophone lines, and both permanent network, reoccupied USArray, and temporary stations at local and regional distances. We found that near-source waveforms are dominated by broad band compressional (P), and band limited surface wave (Rg) (< 10 Hz) phases. Distinct, consistent shear (S) phases are difficult to observe visually even with a comprehensive bank of frequency bands. Secondary phases are indistinct at near-local distances, unlike for earthquake sources, especially at the high frequencies of interest for discrimination (e.g. 4-8 Hz), likely due to intense near surface scattering. S phases begin to emerge from the scattered background at and beyond 100 km. We identified regional Pn, Pg and Lg phases to 446 km for SPE-5. The data set is, unfortunately, plagued by poorly recorded instrument responses, or, possibly, time varying site amplification due to human interaction with sensors. Instrument response issues should be fixable, and this should be attempted to make this a truly, high-quality data set for use by the monitoring community.

58 GEOSCIENCES↗

Performance Refactoring of Instrumentation, Measurement, and Analysis Technologies for Petascale Computing: the PRIMA Project

The growing number of cores provided by today’s high-end computing systems present substantial challenges to application developers in their pursuit of parallel efficiency. To find the most effective optimization strategy, application developers need insight into the runtime behavior of their code. The University of Oregon (UO) and the Julich Supercomputing Centre of Forschungszentrum Julich (FZJ) developed the performance analysis tools TAU and Scalasca, respectively, which allow high-performance computing (HPC) users to collect and analyze relevant performance data – even at very large scales. TAU and Scalasca are considered among the most advanced parallel performance systems available, and are used extensively across HPC centers in the U.S., Germany, and around the world.

97 MATHEMATICS AND COMPUTING↗

HTGR Measurements and Instrumentation Systems

This report provides an integrated overview of measurements and instrumentation for near-term future high-temperature gas-cooled reactors (HTGRs). Instrumentation technology has undergone revolutionary improvements since the last HTGR was constructed in the United States. This report briefly describes the measurement and communications needs of HTGRs for normal operations, maintenance and inspection, fuel fabrication, and accident response. The report includes a description of modern communications technologies and also provides a potential instrumentation communications architecture designed for deployment at an HTGR. A principal focus for the report is describing new and emerging measurement technologies with high potential to improve operations, maintenance, and accident response for the next generation of HTGRs, known as modular HTGRs, which are designed with passive safety features. Special focus is devoted toward describing the failure modes of the measurement technologies and assessing the technology maturity.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

System and method for predicting the presence of rare earth elements

A system for predicting rare earth elements (REEs) in a feedstock sample includes a measurement instrument that records a measurement for a sample, a processor communicatively coupled to the measuring instrument, and a memory communicatively coupled to the processor and containing machine readable instructions that, when executed by the processor, cause the processor to correlate the measurement series using a model; and predict a presence of one or more rare earth element based at least in part on the correlation. A method for predicting rare earth elements includes measuring feedstock samples via XRF or PGNAA, to generate a measurements of elements of interest with a lower atomic weight than REEs; correlating the measurements with a model; and predicting a presence of one or more rare earth elements based at least in part on the correlation.

Fuka, Matthew↗

DESIGN AND TEST OF AN INSTRUMENT FOR MEASURING MICROTHERMAL SEEING ON THE MAGDALENA RIDGE

We have constructed and operated an automated instrument for measuring ground-level microthermal seeing at the Magdalena Ridge Observatory (MRO). The MRO is located at an altitude of 10500' in the Cibola National Forest in New Mexico, USA. It is the planned site for the MRO Optical Interferometer (MROI) planned for up to 10 collecting elements, each with a diameter of 1.4 m, and baselines eventually up to approximately 400 m. As part of the preparation for construction we deployed a system to characterize the ground-level seeing across the observatory site. The instrument is built largely of off-the-shelf components, with only the sensor head and power supply requiring electronic board assembly. Even in those cases the board architecture is very simple. The first proof-of-concept system was deployed for several weeks in the autumn of 2004, and has since undergone several iterations. The latest configuration operates entirely off batteries, incorporates wireless data acquisition, and is thus able to operate in an area with no shelter, power, or communications. In this paper we present the design of the instrument, and show initial data. The microthermal tower has four sensor pairs at heights from 0.8 to 4.41 m, significantly lower than other microthermal experiments, because of the need to characterize the seeing near the ground. We find significant variation in the contribution of this range of heights to the seeing, contributing up to 0.''3 of the seeing at some times and only 0.''02 at other times. The individual sensor power spectra have a slope in the range of 1.4--1.5, which is lower than the 1.67 slope predicted by Kolmogorov turbulence theory. We measure the well known effect of improved seeing immediately around sunset. While we find significant variation in the microthermal seeing, we did not find a pattern of corresponding variations in weather conditions, suggesting that a complicated set of factors control microthermal turbulence.

79 ASTRONOMY AND ASTROPHYSICS↗

Steam Generators: Thermal Hydraulic Measurements and Instrumentation

Steam generators are integral components of both conventional and advanced reactors utilizing steam power cycles, as they influence the power conversion performance. Steam generator designs are highly influenced by the type of reactor coolant used, which mainly governs the different control, monitoring, and safety system actuation requirements. Therefore, the present work reviews the thermal hydraulics instrumentation within steam generators designed for pressurized water reactors (PWRs), high-temperature gas-cooled reactors (HTGRs), sodium fast reactors (SFRs), and molten salt cooled reactors (MSRs). Emphasis is given to measurement techniques that are either unique or particularly important to specific reactor types. Lastly, a discussion is provided on the instrumentation and measured parameters. The work identifies standard parameters of interest and is expected to aid the development of test beds and novel measurements techniques.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Current status and prospects for development of thermometry

The paper deals with results of an analysis carried out at the VNIIM with the purpose to ascertain the current status of thermometry as well as to make an attempt to determine a line of development of this field of measurements in future. The analysis was based on a survey of 150 industrial enterprises and scientific organizations. The results of the survey showed that during two last decades the accuracy of measuring instruments used in science and industry was increased almost tenfold. However, advances in the improvement of temperature measuring instruments were achieved not owing to new principles of designing thermometers, but due to rapid development of electronics, which allowed to solve the problem of accurate measurements of resistance and electromotive force and automatize measurement information processing. In most cases the contemporary measuring instruments perfectly meet the requirements to the measurement accuracy claimed by the enterprises surveyed and are provided with a necessary metrological assurance. Although there is a general understanding of the necessity to use the thermodynamic scale rather than the conditional one, we have no objective evidence with regard to how close we have to bring the international scale used in our everyday practice to the thermodynamic scale and what will be a benefit for development of science and industry. Increasing the accuracy of national standards does not affect, as a rule, the accuracy of temperature measurements in industry and scientific research since the main contribution to a total measurement error is made by components caused by an improper measurement procedure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗