Search NASA⌕ Search

SEARCH · Search NASA

Results for “Micro Ion Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Sub-Optical Lithography With Nanometer Definition Masks

Nanometer feature size lithography represents a major paradigm shift for the electronics and micro-electro-mechanical industries. In this paper, we discuss the capacity of dynamic focused reactive ion beam (FIB) etching systems to undertake direct and highly anisotropic erosion of thick evaporated gold coatings on boron-doped silicon X-ray mask membranes. FIB offers a new level of flexibility in micro fabrication, allowing for fast fabrication of X-ray masks, where pattern definition and surface alteration are combined in the same step which eliminates the whole lithographic process, in particular resist, resist development, electro-deposition and resist removal. Focused ion beam diameters as small as 7 nm can be obtained enabling fabrication well into the sub-20 nm regime. In preliminary demonstrations of this X-ray mask fabrication technique 22 nm width lines were milled directly through 0.9 microns of gold and a miniature mass spectrometer pattern was milled through over 0.5 microns of gold. Also presented are the results of the shadow printing, using the large depth of field of synchrotron high energy parallel X-ray beam, of these and other sub-optical defined patterns in photoresist conformally coated over surfaces of extreme topographical variation. Assuming that electronic circuits and/or micro devices scale proportionally, the surface area of devices processed with X-ray lithography and 20 nm critical dimension X-ray masks would be 0.5% that of contemporary devices (350 nm CD). The 20 CD mask fabrication represents an initial effort - a further factor of three reduction is anticipated which represents a further order-of-magnitude reduction in die area.

Hartley, Frank T.↗

Science Observations of Deep Space One

During the Deep Space One (DS1) primary mission, the spacecraft will fly by asteroid 1992 KD and possibly comet Borrelly. There are two technologies being validated on DS1 that will provide science observations of these targets, the Miniature Integrated Camera Spectrometer (MICAS) and the Plasma Experiment for Planetary Exploration (PEPE). MICAS encompasses a camera, an ultraviolet imaging spectrometer and an infrared imaging spectrometer. PEPE combines an ion and electron analyzer designed to determine the three-dimensional distribution of plasma over its field of view. MICAS includes two visible wavelength imaging channels, an ultraviolet imaging spectrometer, and an infrared imaging spectrometer all of which share a single 10-cm diameter telescope. Two types of visible wavelength detectors, both operating between about 500 and 1000 nm are used: a CCD with 13-microrad pixels and an 18-microrad-per-pixel, metal-on-silicon active pixel sensor (APS). Unlike the CCD the APS includes the timing and control electronics on the chip along with the detector. The UV spectrometer spans 80 to 185 nm with 0.64-nm spectral resolution and 316-microrad pixels. The IR spectrometer covers the range from 1200 to 2400 nm with 6.6-nm resolution and 54-microrad pixels PEPE includes a very low-power, low-mass micro-calorimeter to help understand plasma-surface interactions and a plasma analyzer to identify de individual molecules and atoms in the immediate vicinity of the spacecraft that have been eroded off the surface of asteroid 1992 KD. It employs common apertures with separate electrostatic energy analyzers. It measures electron and ion energies spanning a range of 3 eV to 30 keV, with a resolution of five percent. and measures ion mass from one to 135 atomic mass units with 5 percent resolution. It electrostatically sweeps its field of view both in elevation and azimuth. Both MICAS and PEPE represent a new direction for the evolution of science instruments for interplanetary spacecraft. These two instruments incorporate a large fraction of the capability of five instruments that had typically flown on NASA's deep space missions The Deep Space One science team acknowledges the support of Philip Varghese, David H. Lehman, Leslie Livesay, and Marc Rayman for providing invaluable assistance in making the science observations possible.

Nelson, Robert M.↗

A Micro-Thermionic Ionization Source for Chemical Detection

The major goal of this project was to develop an ionization-based detector that could be integrated into the portable gas chromatography systems currently produced by Defiant Technologies. This new detector would allow Defiant to analyze a broader range of analytes and enter new markets. There was also an interest in testing the new ionization source in an ion mobility spectrometer (IMS) that is produced by Sandia National Laboratories. Not only could this eliminate the need for a radioactive material in the IMS, it would offer Defiant the opportunity to add a whole new product line to their chemical analysis systems. Significant progress was made in the development of a thermionic ionization source (TIS) and detector. Using a MEMs heater was an attractive concept, but it proved to be an unfruitful approach because of the fragility of the devices at elevated temperatures. A rugged alternative heater was developed using nichrome wire and alumina tubes. These heaters are simple to make, and, for low quantity production, will be considerably cheaper to construct than MEMs devices. This work has provided a firm basis for follow-on projects. There is now a solid concept for constructing heater elements where, prior to this work, there was only the hope that MEMs heaters would work. In addition, the electrometer that was developed works better than the commercial rack-mounted system that was originally used in this study. Overcoming these two obstacles provides a clear technical approach for product development. There will be follow on efforts at Defiant Technologies to refine the development of the thermal ionization detector. Designs are being made to combine the TIS and electrometer electronics into a single package with a simple-to-replace TIS element. Further work will also focus on integrating this new detector into portable gas chromatography products and testing to optimize the performance.

47 OTHER INSTRUMENTATION↗

Recent Advances in Water Analysis with Gas Chromatograph Mass Spectrometers

We report on progress made in developing a water sampling system for detection and analysis of volatile organic compounds in water with a gas chromatograph mass spectrometer (GCMS). Two approaches are described herein. The first approach uses a custom water pre-concentrator for performing trap and purge of VOCs from water. The second approach uses a custom micro-volume, split-splitless injector that is compatible with air and water. These water sampling systems will enable a single GC-based instrument to analyze air and water samples for VOC content. As reduced mass, volume, and power is crucial for long-duration, manned space-exploration, these water sampling systems will demonstrate the ability of a GCMS to monitor both air and water quality of the astronaut environment, thereby reducing the amount of required instrumentation for long duration habitation. Laboratory prototypes of these water sampling systems have been constructed and tested with a quadrupole ion trap mass spectrometer as well as a thermal conductivity detector. Presented herein are details of these water sampling system with preliminary test results.

quadrupole ion trap↗

Micro-ion Traps for Detection of (Pre)-Biotic Organic Compounds on Comets

Comets are currently believed to be a mixture of interstellar and nebular material. Many of the volatiles in comets are attributed to interstellar chemistry, because the same species of carbonaceous compounds are also observed in ices in interstellar molecular (ISM) clouds. Comets are thus likely to be a relatively pristine reservoir of primitive material and carbonaceous compounds in our solar system. They could be a major contributor to the delivery of prebiotic organic compounds, from which life emerged through impacts on early Earth. Mass spectrometers are very powerful tools to identify unknown chemicals, and much progress bas been made in miniaturizing mas spectrometers for space applications. Most miniatu rized mass spectrometers developed to date, however, are still relatively large, power hungry, complicated to assemble, and would have significant impact on space flight vehicle total payload and resource allocations.

vanAmerom, Friso H. W.↗

Titan Ice and Dust Experiment (TIDE): Detection and Analysis of Compounds of Interest to Astrobiology in the Lower Atmosphere and Surface of Titan

The Titan Orbiter Aerorover Mission (TOAM) is a proposed concept for the Solar System Exploration Visions Mission, Titan Explorer, a follow-on to the Cassini-Huygens mission. TOAM would use a Titan polar orbiter and a lighter-than-air aerorover to investigate the surface and atmosphere of Titan. Astrobiology issues will be addressed though TOAM investigations including, for example: Distribution and composition of organics (atmospheric, aerosol, surface); Organic chemical processes, their chemical context and energy sources; and Seasonal variations and interactions of the atmosphere and surface. The TIDE instrument will perform in-situ analyses to obtain comprehensive and sensitive molecular and elemental assays of volatile organics in the atmosphere, oceans and surface. TIDE chemical analyses are conducted by a Gas Chromatograph-Ion Mobility Spectrometer (GC-IMS). This TIDE GC-IMS was a component of the mini-Cometary Ice and Dust Experiment (mini-CIDEX) developed for the chemical analysis of a cometary environment. Both the GC and helium IMS of mini-CIDEX have been further developed to better meet the analytical and operational requirements of the TOAM. application. A Micro-ElectroMechanical System (MEMS) GC and Mini-Cell helium IMS are under development to replace their respective mini-CIDEX components, providing similar or advanced analytical capabilities.

Kojiro, Daniel R.↗

Ion Chromatography-on-a-chip for Water Quality Analysis

We report progress towards developing a Micro-Electro-Mechanical Systems (MEMS)- based ion chromatograph (IC) for crewed spacecraft water analysis. This IC-chip is an offshoot of a NASA-funded effort to produce a high performance liquid chromatograph (HPLC)-chip. This HPLC-chip system would require a desalting (i.e. ion chromatography) step. The complete HPLC instrument consists of the Jet Propulsion Labortory's (JPL's) quadrupole ion trap mass spectrometer integrated with a state-of-the-art MEMS liquid chromatograph (LC) system developed by the California Institute of Technology's (Caltech's) Micromachining Laboratory. The IC version of the chip consist of an electrolysis-based injector, a separation column, two electrolysis pumps for gradient generation, mixer, and a built-in conductivity detector. The HPLC version of the chip also includes a nanospray tip. The low instrument mass, coupled with its high analytical capabilities, makes the LC chip ideally suitable for wide range of applications such as trace contaminant, inorganic analytical science and, when coupled to a mass spectrometer, a macromolecular detection system for either crewed space exploration vehicles or robotic planetary missions.

Kidd, R. D.↗

NASA Tech Briefs, June 2008

Topics covered include: Charge-Control Unit for Testing Lithium-Ion Cells; Measuring Positions of Objects Using Two or More Cameras; Lidar System for Airborne Measurement of Clouds and Aerosols; Radiation-Insensitive Inverse Majority Gates; Reduced-Order Kalman Filtering for Processing Relative Measurements; Spaceborne Processor Array; Instrumentation System Diagnoses a Thermocouple; Chromatic Modulator for a High-Resolution CCD or APS; Commercial Product Activation Using RFID; Cup Cylindrical Waveguide Antenna; Aerobraking Maneuver (ABM) Report Generator; ABM Drag_Pass Report Generator; Transformation of OODT CAS to Perform Larger Tasks; Visualization Component of Vehicle Health Decision Support System; Mars Reconnaissance Orbiter Uplink Analysis Tool; Problem Reporting System; G-Guidance Interface Design for Small Body Mission Simulation; DSN Scheduling Engine; Replacement Sequence of Events Generator; Force-Control Algorithm for Surface Sampling; Tool for Merging Proposals Into DSN Schedules; Micromachined Slits for Imaging Spectrometers; Fabricating Nanodots Using Lift-Off of a Nanopore Template; Making Complex Electrically Conductive Patterns on Cloth; Special Polymer/Carbon Composite Films for Detecting SO2; Nickel-Based Superalloy Resists Embrittlement by Hydrogen; Chemical Passivation of Li+-Conducting Solid Electrolytes; Organic/Inorganic Polymeric Composites for Heat-Transfer Reduction; Composite Cathodes for Dual-Rate Li-Ion Batteries; Improved Descent-Rate Limiting Mechanism; Alignment-Insensitive Lower-Cost Telescope Architecture; Micro-Resistojet for Small Satellites; Using Piezoelectric Devices to Transmit Power through Walls; Miniature Latching Valve; Apparatus for Sampling Surface Contamination; Novel Species of Non-Spore-Forming Bacteria; Chamber for Aerosol Deposition of Bioparticles; Hyperspectral Sun Photometer for Atmospheric Characterization and Vicarious Calibrations; Dynamic Stability and Gravitational Balancing of Multiple Extended Bodies; Simulation of Stochastic Processes by Coupled ODE-PDE; Cluster Inter-Spacecraft Communications; Genetic Algorithm Optimizes Q-LAW Control Parameters; Low-Impact Mating System for Docking Spacecraft; Non-Destructive Evaluation of Materials via Ultraviolet Spectroscopy; Gold-on-Polymer-Based Sensing Films for Detection of Organic and Inorganic Analytes in the Air; and Quantum-Inspired Maximizer.

Source record↗

CLUST - EVAP Monte Carlo Simulation Applications for Determining Effective Energy Deposition in Silicon by High Energy Protons

The CLUST-EVAP is a Monte Carlo simulation of the interaction of high energy (25 - 400 MeV) protons with silicon nuclei. The initial nuclear cascade stage is modeled using the CLUST model developed by Indiana University over 30 years ago. The second stage, in which the excited nucleus evaporates particles in random directions, is modeled according to the evaporation algorithm provided by H. H. K. Tang of IBM. Using the CLUST-EVAP code to model fragment produ6tion and the Vavilov-Landau theory to model fluctuations in direct ionization in thin silicon layers, we have predicted energy deposition in silicon components for various geometrical configurations. We have compared actual measurements with model predictions for geometry's such as single, thin silicon particle detectors, telescopic particle detectors flown in space to measure the environment, and thin sensitive volumes of modern micro-electronic components. We have recently compared the model predictions with actual measurements made by the DOSTEL spectrometer flown in the Shuttle payload bay on STS-84. The model faithfully reproduces the features and aids in interpretation of flight results of this instrument. We have also applied the CLUST-EVAP model to determine energy deposition in the thin sensitive volumes of modern micro-electronic components. We have accessed the ability of high energy (200 MeV) protons to induce latch-up in certain devices that are known to latch up in heavy ion environments. However, some devices are not nearly as susceptible to proton induced latch-up as expected according to their measured heavy ion latch-up cross sections. The discrepancy is believed to be caused by the limited range of the proton-silicon interaction fragments. The CLUST-EV AP model was used to determine a distribution of these fragments and their range and this is compared to knowledge of the ranges required based on the known device structure. This information is especially useful in accessing the risk to on-orbit perfonnance in a heavy ion environment based on testing performed with only protons.

ONeill, Pat M.↗

Tandem LA-ICP-MS & LIBS; A New Micro-Analytical Technique for the Measurement of Every Element in the Periodic Table

Laser Ablation ICP-MS (LA-ICP-MS) has been widely accepted as a microanalytical technique for in-situ trace (ppb) elemental analysis on the micron scale in a variety of geologic materials. LA-ICP-MS (single or multi-collector) provides both elemental and isotopic measurements critical for a wide range of geological research by generating a fine grained aerosol (nm scale) during the laser ablation event and delivering that aerosol to the ICP ion source of the mass spectrometer via an inert carrier gas. LA-ICP-MS, however, suffers from limitations in analyzing high ionization potential elements as well as elements subject to atmospheric and argon based interferences. LA-ICP-MS also has limitations in analyzing major elements due to detector saturation. An alternative laser ablation technique, Laser Induced Breakdown Spectroscopy (LIBS), employs an optical spectrometer integrated into the laser ablation system that analyzes the laser induced plasma at the sample surface across the entire optical spectrum for emission lines of every element in the periodic table. Elements that are difficult or impossible to measure with LA-ICP-MS are now possible to analyze with LIBS down to low ppm levels with CCD and/or ICCD detection. We introduce a new laser based technique, “Tandem LA-LIBS”, that combines LA for ICP-MS and LIBS into one integrated laser ablation system. This system has the effect of expanding the elemental coverage and the dynamic range of the laser ablation experiment as measurements from ppb to % level matrix elements can now be analyzed in a single ablation experiment. We present both femtosecond and nanosecond Tandem LA-LIBS quantitative and qualitative data on wide range of geological materials for those elements that are difficult or impossible by traditional LA-ICP-MS techniques such as F, H, O, N, C, S, halogens, etc. We also demonstrate that the simultaneous measurement of trace, minor and major elements are now possible in a single laser ablation experiment with Tandem LA-LIBS technology.

LA-ICP-MS↗

Analytical/Operational Requirements for the In Situ Chemical Analysis of Cometary and Planetary Environments Using GC-IMS

Exobiology flight experiments require highly sensitive instrumentation for the in situ analysis of the volatile chemical species that occur in the atmospheres and surfaces of various bodies within the solar system. The complex mixtures encountered place a heavy burden on the analytical instrumentation to detect and identify all species present. The minimal resources available onboard for such missions mandate that the instruments provide maximum analytical capabilities with minimal requirements of volume, weight and consumables. The miniCIDEX instrument was developed for the chemical analysis of a cemetery environment. It combined a Gas Chromatograph (GC) with a helium based Ion Mobility Spectrometer (IMS) to fulfill the analytical requirements of a cemetery exobiology mission: universal response; ppb sensitivity; low mass, volume and consumable MiniCIDEX is now a candidate for the chemical analysis instrument of a Titan Aero-rover Mission. The complexity of the analyses will be similar to the comet application with a heavier emphasis on organic molecules. Because the Titan Aero-Rover will be a balloon powered rover, much more attention is placed on the total mass of the instrument package. The GC will likely be a Micro-Electro-Mechanical-System (MEMS) design, smaller than the initial miniCIDEX GC by a factor of ten (with a similar reduction in consumable use). Similar miniaturization of the helium-based IMS will be necessary while maintaining the analytical capabilities. The two mission applications, the analytical requirements, and the evolution of the IMS design to accommodate these requirements will be presented.

Kojiro, Daniel R.↗

Perturbative analysis of low-frequency instabilities in high-field ST40 experiments

Abstract Linear and nonlinear perturbative analyses of low-frequency instabilities are presented for ST40 spherical torus high field plasmas, with simultaneous neutral beam heating due to two tangential sources at 25 keV and 55 keV. Initial plasma profiles on which the TRANSP and NUBEAM codes were based were obtained using an integrated analysis of several diagnostics including line-of-sight integrated and volume average measurements, as well as limited profile information from a charge-exchange-recombination spectrometer. Magnetohydrodynamics (MHD) analysis using the NOVA/NOVA-K codes suggests that the modes in the experiments are core-localized n = 1 eigenmodes with mixed acoustic and electromagnetic Alfvénic polarization. The global transport combined with the perturbative mode analysis indicates that there is greater tendency for bursty chirping response as the level of background micro-turbulence decreases in time and those predictions are shown to be consistent with the experimental data. This finding is interpreted in terms of the suppression of coherent phase-space structures that support chirping when the resonant fast ion dynamics is dominated by frequent stochastic, orbit-decorrelating events.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact high repetition rate Thomson parabola ion spectrometer

Here, we present the development of a compact Thomson parabola ion spectrometer capable of characterizing the energy spectra of various ion species of multi-MeV ion beams from >10 20 W/cm 2 laser produced plasmas at rates commensurate with the highest available from any of the current and near-future PW-class laser facilities. This diagnostic makes use of a polyvinyl toluene based fast plastic scintillator (EJ-260), and the emitted light is collected using an optical imaging system coupled to a thermoelectrically cooled scientific complementary metal–oxide–semiconductor camera. This offers a robust solution for data acquisition at a high repetition rate, while avoiding the added complications and nonlinearities of micro-channel plate based systems. Different ion energy ranges can be probed using a modular magnet setup, a variable electric field, and a varying drift-distance. We have demonstrated operation and data collection with this system at up to 0.2 Hz from plasmas created by irradiating a solid target, limited only by the targeting system. With the appropriate software, on-the-fly ion spectral analysis will be possible, enabling real-time experimental control at multi-Hz repetition rates.

47 OTHER INSTRUMENTATION↗

Ion Bombardment Experiments Suggesting an Origin for Organic Particles in Pre-Cometary and Cometary Ices

Simple molecules frozen as mantles of interstellar and circumstellar grains and incorporated into comets are subjected to ion bombardment in the form of cosmic rays, stellar flares, stellar winds, and ions accelerated in stellar wind shocks. The total expected dosage for the variety of situations range from 10 eV/molecule for interplanetary dust subjected to solar flares to 10(exp 6) eV/molecule for material in the T Tauri environment. Utilizing a Van de Graaff accelerator and a target chamber having cryogenic and mass spectrometer capabilities, we have bombarded frozen gases in the temperature range of 10 K to 30 K with 175 keV protons. After irradiation, removal of the ice by sublimation at an elevated temperature in vacuum reveals a fluffy residue. These experiments suggest that processes resulting in the formation of organic particles found in the coma of Comet Halley, "CHON", may have included ion bombardment. Also, the moderate energy (100 keV to 500 keV) shock accelerated ion environment of bipolar outflow of stars in the planetary nebula stage such as the Red Rectangle, could produce complex molecular species which emit the observed unidentified infrared bands at 3.3 micro-m, 6.2 micro-m, 7.7 micro-m, 8.6 micro-m, and 11.3 micro-m.

Wdowiak, Thomas J.↗

Galileo Ultraviolet Spectrometer experiment

The Galileo ultraviolet spectrometer experiment uses data obtained by the Ultraviolet Spectrometer (UVS) mounted on the pointed orbiter scan platform and from the Extreme Ultraviolet Spectrometer (EUVS) mounted on the spinning part of the orbiter with the field of view perpendicular to the spin axis. The UVS is a Ebert-Fastie design that covers the range 113-432 nm with a wavelength resolution of 0.7 nm below 190 and 1.3 nm at longer wavelengths. The UVS spatial resolution is 0.4 deg x 0.1 deg for illuminated disk observations and 1 deg x 0.1 deg for limb geometries. The EUVS is a Voyager design objective grating spectrometer, modified to cover the wavelength range from 54 to 128 nm with wavelength resolution 3.5 nm for extended sources and 1.5 nm for point sources and spatial resolution of 0.87 deg x 0.17 deg. The EUVS instrument will follow up on the many Voyager UVS discoveries, particularly the sulfur and oxygen ion emissions in the Io torus and molecular and atomic hydrogen auroral and airglow emissions from Jupiter. The UVS will obtain spectra of emission, absorption, and scattering features in the unexplored, by spacecraft, 170-432 nm wavelength region. The UVS and EUVS instruments will provide a powerful instrument complement to investigate volatile escape and surface composition of the Galilean satellites, the Io plasma torus, micro- and macro-properties of the Jupiter clouds, and the composition structure and evolution of the Jupiter upper atmosphere.

Hord, C. W.↗

Vibrational signatures of HNO 3 acidity when complexed with microhydrated alkali metal ions, M + ∙(HNO 3 )(H 2 O) n =5 (M = Li, K, Na, Rb, Cs), at 20 K

The speciation of strong acids like HNO 3 under conditions of restricted hydration is an important factor in the rates of chemical reactions at the air-water interface. Here we explore the trade-offs in play when HNO 3 is attached to alkali ions (Li + -Cs + ) with four water molecules in their primary hydration shells. This is achieved by analyzing the vibrational spectra of the M + ∙(HNO 3 )(H 2 O) 5 clusters cooled to about 20 K in a cryogenic photofragmentation mass spectrometer. The local acidity of the acidic OH group is estimated by the extent of the red shift in its stretching frequency when attached to a single water molecule. Here, the persistence of this local structural motif (HNO 3 -H 2 O) in all of these alkali metal clusters enables us to determine the competition between the effect of the direct complexation of the acid with the cation, which acts to enhance acidity, and the role of the water network in the first hydration shell around the ions, which acts to counter (screen) the intrinsic effect of the ion. Analysis of the vibrational features associated with the acid molecule as well as those of the water network reveal how cooperative interactions in the micro hydration regime conspire to effectively offset the intrinsic enhancement of HNO 3 acidity afforded by attachment to the smaller cations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulation of MEMS for the Next Generation Space Telescope

The NASA Goddard Space Flight Center (GSFC) is developing optical micro-electromechanical system (MEMS) components for potential application in Next Generation Space Telescope (NGST) science instruments. In this work, we present an overview of the electro-mechanical simulation of three MEMS components for NGST, which include a reflective micro-mirror array and transmissive microshutter array for aperture control for a near infrared (NIR) multi-object spectrometer and a large aperture MEMS Fabry-Perot tunable filter for a NIR wide field camera. In all cases the device must operate at cryogenic temperatures with low power consumption and low, complementary metal oxide semiconductor (CMOS) compatible, voltages. The goal of our simulation efforts is to adequately predict both the performance and the reliability of the devices during ground handling, launch, and operation to prevent failures late in the development process and during flight. This goal requires detailed modeling and validation of complex electro-thermal-mechanical interactions and very large non-linear deformations, often involving surface contact. Various parameters such as spatial dimensions and device response are often difficult to measure reliably at these small scales. In addition, these devices are fabricated from a wide variety of materials including surface micro-machined aluminum, reactive ion etched (RIE) silicon nitride, and deep reactive ion etched (DRIE) bulk single crystal silicon. The above broad set of conditions combine to be a formidable challenge for space flight qualification analysis. These simulations represent NASA/GSFC's first attempts at implementing a comprehensive strategy to address complex MEMS structures.

Mott, Brent↗

Laboratory Astrophysics using a Microcalorimeter and Bragg Crystal Spectrometer on an Electron Beam Ion Trap

When we last reported, our new microcalorimeter system was being prepared for delivery and permanent installation at the NIST EBIT. This occurred in June 2003 and check-out with the internal calibration source and EBIT plasma x-rays took place over the next several months during which time we modified several component parts to improve the performance. These changes included: 1) A redesign of the x-ray calibration source from a direct electron impact source to one that irradiates the microcalorimeter with fluorescent x-rays. The resulting calibration lines are free of bremsstrahlung background; 2) The microcalorimeter electronic circuit has been significantly improved to ensure long-term stability for the lengthy upcoming runs of the EBIT. Both the preamplifier feedback resistors were changed and the first stage of the preamplifier redesigned. Several photos of the new system are shown in slides 3 and 4. This microcalorimeter spectrometer only requires helium refills every three days (as opposed to every 24 hours in our earlier system) and it will hold a temperature of 65 mK for up to 48 hours (as opposed to 8 hours). Consequently, the efficiency of data acquisition will improve dramatically. The first x-ray spectra of the new calibration source made with the 4-element detector array is shown. An example of the temperature control capabilities of the ADR for a 23 hour interval is shown. The horizontal line shows the temperature stability (about +/- 3 micro kelvin). There are a few short-lived heating excursions caused by technical staff working on the EBIT machine simultaneously. During actual experimental runs these are absent. This temporal profile was interrupted to test additional components of the system; otherwise, the temperature controlling would have continued for another 24 hours.

Silver, Eric↗