Search NASASearch

SEARCH · Search NASA

Results for “Microcalorimeter Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The EBIT Calorimeter Spectrometer: A New, Permanent User Facility at the LLNL EBIT

The EBIT Calorimeter Spectrometer (ECS) has recently been completed and is currently being installed at the EBIT facility at the Lawrence Livermore National Laboratory. The ECS will replace the smaller XRS/EBIT spectrometer that has been in almost continuous operation since 2000. The XRS/EBIT was based on a spare laboratory cryostat and an engineering model detector system from the Suzaku/XRS observatory. The new ECS spectrometer was built from the ground up to be a low maintenance, high performance microcalorimeter spectrometer with 4 eV resolution at 6 keV, 32 detector channels, 10 us event timing, and capable of uninterrupted acquisition sessions of over 70 hours at 50 mK. The XRSIEBIT program has been extremely successful, producing over two-dozen refereed publications on topics such as laboratory astrophysics, atomic physics, nuclear physics, and calibration of the spectrometers for the National Ignition Facility, with many more publications in preparation. The ECS spectrometer will continue this work into the future with improved spectral resolution, integration times, and ease-of-use. We designed the ECS instrument with TES detectors in mind by using the same highly successful magnetic shielding as our laboratory TES cryostats. This design will lead to a future TES instrument at the LLNL EBIT. This proposed future instrument would include a hybrid detector system with 0.8 eV resolution in the band from 0.1-1.0 keV, 2 eV from 0.1-10 keV, and 30 eV from 0.5-100 keV, with high quantum efficiency in each band. Here we discuss the legacy of the XRS/EBIT program, the performance of the new ECS spectrometer, and plans for a future TES spectrometer.

Porter, S.

X-ray Spectrometer

The X-ray Spectrometer (XRS) instrument is a revolutionary non-dispersive spectrometer that will form the basis for the Astro-E2 observatory to be launched in 2005. We have recently installed a flight spare X R S microcalorimeter spectrometer at the EBIT-I facility at LLNL replacing the XRS from the earlier Astro-E mission and providing twice the resolution. The X R S microcalorimeter is an x-ray detector that senses the heat deposited by the incident photon. It achieves a high energy resolution by operating at 0.06K and by carefully controlling the heat capacity and thermal conductance. The XRS/EBIT instrument has 32 pixels in a square geometry and achieves an energy resolution of 6 eV at 6 keV, with a bandpass from 0.1 to 12 keV (or more at higher operating temperature). The instrument allows detailed studies of the x-ray line emission of laboratory plasmas. The XRS/EBIT also provides an extensive calibration "library" for the Astro-E2 observatory.

Porter, F. Scott

Progress Towards Microcalorimeter Gamma Spectroscopy Analysis for Nuclear Fuel Separations

The High Efficiency and Resolution Microcalorimeter Spectrometer, 400 pixels (HERMES-400) is an ultra-high resolution gamma-ray spectrometer at Idaho National Laboratory’s Materials and Fuels Complex. HERMES-400 is intended to enable precise nondestructive analysis of advanced fuel cycle materials. Key upgrades and repairs of the instrument were performed this year to improve performance. First, the fourth and final microcalorimeter detector module was installed, meeting the milestone for its integration into the system. Operation with all four modules enables higher detector efficiency than any previous microcalorimeter gamma-ray system. Second, a thinner magnetic shield was installed. This shields the sensitive microcalorimeter pixels from stray magnetic fields while allowing transmission of lower-energy gamma rays, which are important to isotopic analysis. Finally, the cryostat, which provides cooling of the modules to their operating temperature, was found to have a helium coolant leak, which was repaired. HERMES-400 is in a stable state to perform repeated, long-term gamma-ray measurements with good detector efficiency and energy resolution. In FY25, irradiated TRISO fuel and salts from advanced electrochemical recycling techniques are candidates for microcalorimeter measurements. A final upgrade of the magnetic shielding and vibration damping of the system is also planned to maximize the system performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

The Suzaku High Resolution X-ray Spectrometer

The high resolution X-Ray Spectrometer (XRS) has been designed to provide the Suzaku Observatory with very high spectral resolution, non-dispersive spectroscopy from 0.3 to 12 keV. This energy range encompasses the most diagnostically-rich part of the x-ray band. The sensor consists of a 32 channel array of x-ray of microcalorimeters, each with an energy resolution of about 6 eV. The very low temperature required for operation of the array (60 mK) is provided by a four-stage cooling system containing a single stage ADR, superfluid He Cryostat, solid Ne Dewar, and a single-stage Stirling-cycle cooler. The Suzaku/XRS is the first orbiting x-ray microcalorimeter spectrometer and has been designed to last more than three years in orbit. The early verification phase of the mission demonstrated that the instrument was working properly and that the cryogen consumption rate was low enough to ensure a mission lifetime exceeding 3 years. However, the liquid He cryogen was completely vaporized two weeks after opening the dewar guard vacuum vent. The problem has been traced to inadequate venting of the dewar He and Ne gases out of the spacecraft into space. In this paper we present the design of the XRS instrument and describe the in-flight performance.

Kelley, Richard L.

Measuring X-Ray Emission Line Shapes in Neutral Species for XRISM Calibration

Space X-ray spectrometers such as the Resolve instrument on XRISM require precise calibration in order to interpret the spectra of astrophysical objects. Key components of the calibration are the energy scale and the core line spread function, both of which vary with photon energy. A major issue in the calibration of high-resolution spectrometers is locating good calibrators with well-known and stable intrinsic line shapes. Neutral fluorescence is widely used, but inner-shell transitions in neutral atoms often exhibit complex, poorly documented line shapes that vary with excitation conditions. Here, in this study, we present empirical measurements of K-shell transitions in neutral O and F below 1 keV using an engineering model XRISM calorimeter array, an electron bombardment modulated X-ray source, and an electron beam ion trap (EBIT) to provide a precise energy reference. In addition, we report measurements of the Mo Lα complex with the transition-edge microcalorimeter spectrometer (TEMS), which reveal strong satellite structure and sensitivity of the line shape to the incident exciting spectrum. Together, these results demonstrate the need for empirical line-shape models, highlight the nonstationary nature of neutral fluorescence features, and define a path toward developing transfer standards for XRISM and future precision instruments such as Athena/X-IFU.

Astronomy and AstroPhysics

Spectroscopic diagnostics of high-temperature plasma in stellar coronae using Fe XXIV-XXIV K-shell lines with XRISM

The RS CVn type binary star GT Muscae was observed during its quiescence using the Resolve X-ray microcalorimeter spectrometer onboard XRISM. The main and satellite lines of the Fe XXIV-XXIV K-shell transitions were resolved for the first time from stellar sources. We conducted line ratio analysis to investigate any deviations from collisional ionization equilibrium and Maxwell electron energy distribution with a single temperature. By using five combinations of direct excitation lines and dielectronic recombination satellite lines in three line complexes (Fe He$\alpha$, Ly$\alpha$, and He$\beta$), we found that the plasma is well characterized by two-temperature thermal plasmas with temperatures of 1.7 and 4.3 keV, which is consistent with thermal broadening of Fe xxv, and the broad-band fitting results in the 1.7–10 keV band. Other forms of deviation from a single-temperature plasma, such as different ionization and electron temperatures or the $\kappa$ distribution for the electron energy distributions, are not favored, which is reasonable for stellar coronae at quiescence. This study demonstrates the utility of the Fe K-shell line ratio diagnostics to probe plasma conditions using X-ray microcalorimeters.

X-rays: stars

Overionized plasma in the supernova remnant Sagittarius A East anchored by XRISM observations

Sagittarius A East is a supernova remnant with a unique surrounding environment, as it is located in the immediate vicinity of the supermassive black hole at the Galactic center, Sagittarius A$^{*}$. The X-ray emission of the remnant is suspected to show features of overionized plasma, which would require peculiar evolutionary paths. We report on the first observation of Sagittarius A East with the X-Ray Imaging and Spectroscopy Mission (XRISM). Equipped with a combination of a high-resolution microcalorimeter spectrometer and a large field-of-view CCD imager, we for the first time resolved the Fe xxv K-shell lines into fine structure lines and measured the forbidden-to-resonance intensity ratio to be $1.39 \pm 0.12$, which strongly suggests the presence of overionized plasma. We obtained a reliable constraint on the ionization temperature just before the transition into the overionization state, of $\gt\! 4\:$keV. The recombination timescale was constrained to be $\lt\! 8 \times 10^{11} \:$cm$^{-3}\:$s. The small velocity dispersion of $109 \pm 6\:$km$\:$s$^{-1}$ indicates a low Fe ion temperature $\lt\! 8\:$keV and a small expansion velocity $\lt\! 200\:$km$\:$s$^{-1}$. The high initial ionization temperature and small recombination timescale suggest that either rapid cooling of the plasma via adiabatic expansion from dense circumstellar material or intense photoionization by Sagittarius A$^{*}$ in the past may have triggered the overionization.

galaxy center

XRISM view of a stellar flare: High-resolution Fe K spectra of HR 1099, an RS CVn-type star

A high-resolution X-ray spectroscopic observation was made of the RS CVn-type binary star HR 1099 using the Resolve instrument onboard XRISM for its calibration purposes. During the $\sim$400 ks telescope time covering 1.5 binary orbit, a flare lasting for $\sim$100 ks was observed with a released X-ray radiation energy of ${\sim }10^{34}$ erg, making it the first stellar flare ever observed with an X-ray microcalorimeter spectrometer. The flare peak count rate is 6.4 times higher than that in quiescence and is distinguished clearly in time thanks to the long telescope time. Many emission lines were detected in the 1.7–10 keV range both in the flare and quiescent phases. Using the high spectral resolution of Resolve in the Fe K band (6.5–7.0 keV), we resolved the inner-shell lines of Fe XIX-XXVI as well as the outer-shell lines of Fe XXV-XXVI . These lines have peaks in the contribution functions at different temperatures over a wide range, allowing us to construct the differential emission measure (DEM) distribution over the electron temperature of 1–10 keV (roughly 10–100 MK) based only on Fe lines, thus without an assumption of the elemental abundance. The reconstructed DEM has a bimodal distribution, and only the hotter component increased during the flare. The elemental abundance was derived based on the DEM distribution thus constructed. A significant abundance increase was observed during the flare for Ca and Fe, which are some of the elements with the lowest first ionization potential among those analyzed, but not for Si, S, and Ar. This behavior is seen in some giant solar flares and the present result is a clear example in stellar flares.

Astronomy and AstroPhysics

Energy shift of Fe-K fluorescence lines due to low ionization demonstrated with XRISM in Centaurus X-3

The Fe K$\alpha$ fluorescence line at 6.4 keV is a powerful probe of cold matter surrounding X-ray sources and has been widely used in various astrophysical contexts. The X-ray microcalorimeter spectrometer onboard XRISM can measure line shifts with unprecedented precision of ${\sim }$0.2 eV, equivalent to a line-of-sight velocity of ${\sim }$10 km s$^{-1}$. At this level of accuracy, however, several factors that influence the line energy must be carefully considered prior to astrophysical interpretation. One such important factor is the ionization degree, Fe$^{q+}$. The K$\alpha$ line shifts redward by ${\sim }$4 eV as q increases from 0 (neutral) to 8 (Ar-like). Additionally, the accompanying Fe K$\beta$ line at 7.06 keV shifts blueward by ${\sim }$30 eV from $q=0$ to 8. We demonstrate that this effect is actually observable in the XRISM data of the high-mass X-ray binary Centaurus X-3 (Cen X-3). We advocate that the differential energy shift between the K$\alpha$ and K$\beta$ line provides a robust estimate of q by decoupling from other effects that shift the two lines in the same direction. We derived $q \sim 5$ (Sc-like) for the fluorescing matter by comparing the observation with atomic structure calculations of our own and in the literature. By accounting for the derived charge state and the corresponding shift in the rest-frame line energy, we made corrections for this effect and reached a consistent residual shift among the K$\alpha$, K$\beta$, and the optical measurement attributable to the systemic velocity of the system. Consequently, we obtained a new constraint on the location of the cold matter. This ionization effect needs to be assessed in all use cases of the Fe K$\alpha$ line shift beyond Cen X-3, and the proposed metric is generally applicable to all of them.

Astronomy and AstroPhysics

Kinematic Evidence for Bipolar Ejecta Flows in the Galactic Supernova Remnant W49B

W49B is a unique Galactic supernova remnant with centrally peaked, “bar”-like ejecta distribution, which was once considered evidence for a hypernova origin that resulted in a bipolar ejection of the stellar core. However, chemical abundance measurements contradict this interpretation. Closely connected to the morphology of the ejecta is its velocity distribution, which provides critical details for understanding the explosion mechanism. We report the first ever observational constraint on the kinematics of the ejecta in W49B using the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM). Using XRISM/Resolve, we measured the line-of-sight velocity traced by the Fe Heα emission, which is the brightest feature in the Resolve spectrum, to vary by ±300 km s −1 with a smooth east-to-west gradient of a few tens of kilometers per second per parsec along the major axis. Similar trends in the line-of-sight velocity structure were found for other Fe-group elements Cr and Mn, traced by the Heα emission, and also for intermediate-mass elements Si, S, Ar, and Ca, traced by the Lyα emission. The discovery of the east–west gradient in the line-of-sight velocity, together with the absence of a twin-peaked line profile or enhanced broadening in the central region, clearly rejects the equatorially expanding disk model. In contrast, the observed velocity structure suggests bipolar flows reminiscent of a bipolar explosion scenario. An alternative scenario would be a collimation of the ejecta by an elongated cavity sculpted by bipolar stellar winds.

High resolution spectroscopy

Microcalorimeters for High Resolution X-Ray Spectroscopy of Laboratory and Astrophysical Plasmas

The proposal has three major objectives. The first focuses on advanced neutron-transmutation-doped (NTD)-based microcalorimeter development. Our goal is to develop an array of microcalorimeters with sub- 5 eV energy resolution that can operate with pile-up-free throughput of at least 100 Hz per pixel. The second objective is to establish our microcalorimeter as an essential x-ray diagnostic for laboratory astrophysics studies. We propose to develop a dedicated microcalorimeter spectrometer for the EBIT (electron beam ion trap). This instrument will incorporate the latest detector and cryogenic technology that we have available. The third objective is to investigate innovative ideas related to possible flight opportunities. These include compact, long lived cryo-systems, ultra-low temperature cold stages, low mass and low power electronics, and novel assemblies of thin windows with high x-ray transmission.

Silver, E.

Measurements of K Shell Emission of Highly Charged Ions with the XRS at EBIT

The XRS/EBIT is a 32 channel microcalorimeter spectrometer operating at the electron beam ion trap (EBIT) facility at Lawrence Livermore National Laboratory. The system contains a flight candidate detector array from the XRS instrument for the Astro-E2 mission. The detector array in the XRS/EBIT is functionally identical to the flight array integrated into the XRS instrument and benefits from the enormous amount of calibration data from the XRS program. Since the XRSEBIT was upgraded with the new detector array in October 2003, the system has been used for a number of experiments including a survey of the K shell emission from He-like and H-like O, Ne, Ar, Fe, Ni and Kr as well as for L shell emission to measure the 3C/3D line ratio in Ni. Here we present some basic operational parameters of the instrument as well as direct excitation and simulated maxwellian spectra of He-like and E-like Fe. We show that the XRS instrument can resolve the Lyal and Lya2 lines from each other as well as from the dielectronic recombination satellites in thermal H-like Fe. We also show exactly how well the XRS instrument on Astro-E2 will resolve the thermal He-like triplet in collisionally excited Fe. This work was funded under NASA's Research Opportunities in Space Science program.

Porter, F. Scott

Development and Operation of Arrays of TES x-ray Microcalorimeters Suitable for Constellation-X

Having already developed a transition-edge-sensor (TES) microcalorimeter design that enables uniform and reproducible high spectral resolution (routinely better than 3 eV resolution at 6 keV) and is compatible with high fill-factor arrays, we are now working towards demonstrating this performance at high count rates and with the multiplexed read-out needed for instrumenting the Constellation-X X-ray Microcalorimeter Spectrometer (XMS) focal plane array. Design changes that increase the speed of the individual XMS pixels, such as lowering the heat capacity or increasing the thermal conductance of the link to the 50-mK heatsink, result in larger, faster signals, thus the coupling to the multiplexer and the overall bandwidth of the electronics must accommodate this increase in slew rate. In order to operate the array with high incident x-ray flux without unacceptable degradation of the spectral resolution, the magnitude of thermal and electrical crosstalk must be controlled. We will discuss recent progress in the thermal and electrical designs of our close-packed TES arrays, and we will present spectra acquired through the read-out chain from the multiplexer electronics, through the demultiplexer software, to real-time signal processing.

Kilbourne, C. A.

Laboratory Astrophysics using a Microcalorimeter and Bragg Crystal Spectrometer on an Electron Beam Ion Trap

When we last reported, our new microcalorimeter system was being prepared for delivery and permanent installation at the NIST EBIT. This occurred in June 2003 and check-out with the internal calibration source and EBIT plasma x-rays took place over the next several months during which time we modified several component parts to improve the performance. These changes included: 1) A redesign of the x-ray calibration source from a direct electron impact source to one that irradiates the microcalorimeter with fluorescent x-rays. The resulting calibration lines are free of bremsstrahlung background; 2) The microcalorimeter electronic circuit has been significantly improved to ensure long-term stability for the lengthy upcoming runs of the EBIT. Both the preamplifier feedback resistors were changed and the first stage of the preamplifier redesigned. Several photos of the new system are shown in slides 3 and 4. This microcalorimeter spectrometer only requires helium refills every three days (as opposed to every 24 hours in our earlier system) and it will hold a temperature of 65 mK for up to 48 hours (as opposed to 8 hours). Consequently, the efficiency of data acquisition will improve dramatically. The first x-ray spectra of the new calibration source made with the 4-element detector array is shown. An example of the temperature control capabilities of the ADR for a 23 hour interval is shown. The horizontal line shows the temperature stability (about +/- 3 micro kelvin). There are a few short-lived heating excursions caused by technical staff working on the EBIT machine simultaneously. During actual experimental runs these are absent. This temporal profile was interrupted to test additional components of the system; otherwise, the temperature controlling would have continued for another 24 hours.

Silver, Eric

Laboratory Astrophysics using a Microcalorimeter and Bragg Crystal Spectrometer on an Electron Beam Ion Trap

During the past year we have been preparing our new microcalorimeter system for permanent delivery to the NIST EBIT. Unfortunately, there have been delays due to technical difficulties in the fabrication of the two-stage adiabatic demagnetization refrigerator and in the life expectancy of the thin windows used for internal thermal baffling of the infrared radiation. These problems have been solved and we are completing tests of the entire system and it will be set up at NIST during the first week of May. Several photos of the new system are shown in Figures 1A and 1B. This microcalorimeter spectrometer only requires helium refills every three days (as opposed to every 24 hours) and it will hold a temperature! of 65 mK for up to 48 hours (as opposed to 8 hours). Consequently, the efficiency of data acquisition will improve dramatically. In parallel we have published a paper that reviews our previous work (Takacs et al. 2003), especially on Fe XVII, in the context of recent measurements by other groups. This paper is included. We highlight a recent measurement of a broad band spectrum of Fe in Figure 2 that simultaneously includes L and K radiation. It is compared with the simulated spectrum of the Perseus Cluster that one could expect to obtain with a microcalorimeter in the focus of a grazing incidence telescope such as the one being designed for Constellation X. Both the charge state distributions and the relative intensity ratios of the emission lines within the particular charge state are very similar in the two spectra. This further demonstrates the importance and relevance of the laboratory measurements in predicting the components of cosmic spectra.

Brinton, John C.

Toward Large Field-of-view X-ray Spectrometers with Magnetic Microcalorimeters

A future X-ray telescope mission like Lynx, a X-ray flagship mission concept, requires a large field of view, high energy resolution, and high spatial resolution. The Magnetic Microcalorimeter (MMC) detectors we are developing for such a mission feature a 5-arcminute field of view, approximately 100,000 pixels, each spanning 0.5–1 arcsecond. These detectors require the readout of 8,000 sensors. Three different array types have been designed to meet scientific goals, two of which utilize thermal multiplexing to reduce the number of readout channels in a scheme called “Hydra.” We are currently fabricating detectors on a recently completed buried wiring wafer with connections to every sensor. The sensors are read out using a microwave multiplexer (μMUX) with flux ramp modulation. A single μMUX can read out approximately 1,000 sensors with only two feed lines. We will report on the test of the first two-dimensional μMUX chip, consisting of 78 resonators. μMUX chips that pass screening will be directly bonded to MMC array chips using indium bump bonding. In parallel, we have tested a kinetic inductance traveling wave parametric amplifier (KI-TWPA) to amplify signals at low temperatures. The KI-TWPA exhibits extremely low internal noise, approaching the standard quantum limit. Since the energy resolution of an MMC is primarily limited by the readout system, the KI-TWPA is an ideal amplifier for MMCs with μMUX readout. We recently measured the readout noise of a μMUX with a KI-TWPA, demonstrating its capability for reading out MMC arrays. We present the design and fabrication of the latest MMC detectors, along with its readout performance.

Magntic Microcalorimeters

The High Resolution Microcalorimeter Soft X-Ray Spectrometer for the Astro-H Mission

We are developing the Soft X-Ray Spectrometer for the JAXA Astro-H mission. The instrument features a 5 eV, 36-pixel array of micro calorimeters designed for high spectral resolution from 0.3-12 keV at the focus of an x-ray mirror, providing a field of view of3 x 3 arcmin. The principal components of the spectrometer are the microcalorimeter detector system, a 3-stage ADR and dewar. The dewar is a long-life, hybrid design with a superfluid He cryostat, Joule-Thomson cooler, and Stirling coolers. We describe the present design of the SXS instrument and initial engineering model test results.

Kelley, Richard L.

Laboratory Astrophysics Using a Microcalorimeter and Bragg Crystal Spectrometer on an Electron Beam Ion Trap

We completed modifications to the new microcalorimeter system dedicated for use on the EBIT at NIST, which included: 1) a redesign of the x-ray calibration source from a direct electron impact source to one that irradiates the microcalorimeter with fluorescent x-rays. The resulting calibration lines are free of bremsstrahlung background; 2) the microcalorimeter electronic circuit was significantly improved to ensure long-term stability for lengthy experimental runs

Brinton, John