Search NASASearch

SEARCH · Search NASA

Results for “Microcalorimeter Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

25 records · Page 2

Optimization of X-ray event screening using ground and in-orbit data for the Resolve instrument onboard the XRISM satellite

The X-Ray Imaging and Spectroscopy Mission (XRISM) satellite was successfully launched and put into a low-Earth orbit on September 6, 2023 (UT). The Resolve instrument onboard XRISM hosts an X-ray microcalorimeter detector, which was designed to achieve a high-resolution ( ≤ 7 eV FWHM at 6 keV), high-throughput, and non-dispersive spectroscopy over a wide energy range. It also excels in a low background with a requirement of < 2 × 10 -3 s -1 keV -1 (0.3 to 12.0 keV), which is equivalent to only one background event per spectral bin per 100-ks exposure. Event screening to discriminate X-ray events from background is a key to meeting the requirement. We present the result of the Resolve event screening using data sets recorded on the ground and in orbit based on the heritage of the preceding X-ray microcalorimeter missions, in particular, the Soft X-ray Spectrometer onboard ASTRO-H. We optimize and evaluate 19 screening items of three types based on (1) the event pulse shape, (2) relative arrival times among multiple events, and (3) good time intervals. We show that the initial screening, which is applied for science data products in the performance verification phase, reduces the background rate to 1.8 × 10 -3 s -1 keV -1 meeting the requirement. We further evaluate the additional screening utilizing the correlation among some pulse shape properties of X-ray events and show that it further reduces the background rate, particularly in the < 2 keV band. Over 0.3 to 12 keV, the background rate becomes 1.0 × 10 -3 s -1 keV -1 .

47 OTHER INSTRUMENTATION

Outflowing photoionized plasma in Circinus X-1 using the high-resolution X-ray spectrometer Resolve onboard XRISM and the radiative transfer code cloudy

High-resolution X-ray spectroscopy is a key to understanding the mass inflow and outflow of compact objects. Spectral lines carry information about the ionization, density, and velocity structures through their intensity ratios and profiles. They are formed in non-local thermodynamic equilibrium conditions under the intense radiation field from the compact objects; thus radiative transfer (RT) calculation is a requisite for proper interpretations. We present such a study for a low-mass X-ray binary, Circinus X-1, from which the P Cygni profile was discovered using the X-ray grating spectrometer onboard Chandra. We observed the source using the X-ray microcalorimeter onboard XRISM at an orbital phase of 0.93–0.97 and revealed many spectral features unidentified before: the higher series transitions ($n{\rightarrow }1$; $n>2$) of highly ionized (H- and He-like) S, Ca, Ar, and Fe in emission and absorption, the Fe K$\alpha$ and K$\beta$ inner-shell excitation absorption of mildly ionized (O- to Li-like) Fe, and resolved fine-structure level transitions in the Fe Ly$\alpha$ and He$\alpha$ complexes. They blend with each other at different velocity shifts on top of apparently variable continuum emission that changed its flux by an order of magnitude within a 70 ks telescope time. Despite such complexity in the observed spectra, most of them can be explained by a simple model consisting of the photoionized plasma outflowing at $\sim$300 km s$^{-1}$ and the variable blocking material in the line of sight of the incident continuum emission from the accretion disk. We demonstrate this with the aid of the RT code cloudy for the line ratio diagnostics and spectral fitting. We further constrain the physical parameters of the outflow and argue that the outflow is launched close to the outer edge of the accretion disk and can be driven radiatively by being assisted by the line force calculated using the RT simulation.

X-rays: binaries

Pre- and post-launch operation of the Resolve soft X-ray spectrometer onboard the XRISM satellite

Resolve is a high-resolution X-ray spectrometer onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), launched on September 6 (UT), 2023. The Resolve has performed better than its required spectral resolution (7 eV at full width at half maximum at 6 keV), both on the ground and in orbit, and has been confirmed to have comparable performance to the soft X-ray spectrometer onboard the ASTRO-H (Hitomi) satellite. The focal plane is composed of an array of microcalorimeter detectors operated at 50 mK to achieve the required energy resolution, and the cooling system is designed to satisfy the lifetime requirement of over 3 years. The focal plane and cooling system are contained in a vacuum-insulated dewar. The cooling system is equipped with a two-stage adiabatic demagnetization refrigerator (ADR) that uses superfluid liquid helium (LHe) as its heat sink. The system includes a third ADR stage that can be used to provide the heat sink when the helium is exhausted. A Joule–Thomson cooler and several two-stage Stirling coolers are used to reduce the heat load on the LHe. During pre-launch operations, we carried out a superfluid LHe top-off operation. The resultant amount of LHe onboard Resolve was over 35 L before launch, which is sufficient to meet the lifetime requirement. During post-launch operation, the LHe vent valve was opened 5 min after launch during rocket acceleration, and the cryocoolers were turned on after several orbits, as planned, which established stable cooling within the dewar. Pre- and post-launch operations for the Resolve instrument were planned around multiple constraints from launch vehicle operations; all were successfully completed, and the launch requirements were fully met.

X-Ray Imaging and Spectroscopy Mission

Detection of the Orbital Modulation of Fe Kα Fluorescence Emission in Centaurus X-3 Using the High-resolution Spectrometer Resolve on board XRISM

Abstract The Fe K α fluorescence line emission in X-ray spectra is a powerful diagnostic tool for various astrophysical objects to reveal the distribution of cold matter around photoionizing sources. The advent of the X-ray microcalorimeter on board the XRISM satellite will bring new constraints on the emission line. We present one of the first such results for the high-mass X-ray binary Centaurus X-3, which is composed of an O-type star and a neutron star (NS). We conducted a 155 ks observation covering an entire binary orbit. A weak Fe K α line was detected in all orbital phases at an equivalent width (EW) of 10–20 eV. We found for the first time that its radial velocity (RV) is sinusoidally modulated by the orbital phase. The RV amplitude is 248 ± 13 km s −1 , which is significantly smaller than the value (391 km s −1 ) expected if the emission is from the NS surface, but is consistent if the emission takes place at the O star surface. We discuss several possibilities of the line production site, including the NS surface, O star surface, O star wind, and accretion stream from the O star to the NS. We ran radiative transfer calculation for some of them assuming spherically symmetric density and velocity profiles and an isotropic distribution of X-ray emission from the NS. None of them explains the observed EW and velocity dispersion dependence on the orbital phase, suggesting that more elaborated modeling is needed. In other words, the present observational results have the capability to constrain deviations from these assumptions.

High energy astrophysics

Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission

We present an overview of the design and in-flight performance of the Resolve soft X-ray spectrometer on the X-Ray Imaging and Spectroscopy Mission that was successfully launched on September 7, 2023, on a JAXA H-IIA rocket from the Tanegashima Space Center of Japan. The instrument has a 36-pixel array of microcalorimeters, 35 of which are at the focus of a high-throughput grazing-incidence X-ray mirror. The instrument has achieved its required operational base temperature of 0.05 K and a spectral resolution of 4.5 eV (FWHM) at 6 keV. The cooling chain was designed to provide a lifetime of at least 3 years in orbit and operate with and without liquid helium to provide redundancy and the longest operational lifetime for the instrument. Early indications are that the cryogen lifetime may reach 6 years with a cryogen-free mode thereafter. A series of onboard X-ray calibration sources produces energy scale calibration lines simultaneously while observing celestial sources. The overall design and in-flight performance of Resolve are described.

Astronomy and AstroPhysics

Resolve instrument onboard XRISM: design, integration, and instrument test results

The Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM) consists of an array of 6 × 6 silicon-thermistor microcalorimeters cooled down to 50 mK and a high-throughput X-ray mirror assembly (XMA) with a focal length of 5.6 m. XRISM is a recovery mission of ASTRO-H/Hitomi, and the Resolve instrument is a rebuild of the ASTRO-H Soft X-ray spectrometer (SXS) and the Soft X-ray Telescope (SXT) that achieved energy resolution of ∼ 5 eV FWHM on orbit, with several important changes based on lessons learned from ASTRO-H. The flight models of the Dewar and the electronics boxes were fabricated, and the instrument test and calibration were conducted in 2021. By tuning the cryocooler frequencies, energy resolution better than 4.9 eV FWHM at 6 keV was demonstrated for all 36 pixels and high-resolution grade events, as well as energy-scale accuracy better than 2 eV up to 30 keV. The immunity of the detectors to microvibration, electrical conduction, and radiation was evaluated. The instrument was delivered to the spacecraft system in April 2022. The XMA was tested and calibrated separately. Its angular resolution is 1.27′, and the effective area of the mirror itself is 570 cm 2 at 1 keV and 424 cm 2 at 6 keV. We report the design and the major changes from the ASTRO-H SXS, the integration, and the results of the instrument test.

X-ray

In-flight performance of the XRISM/Resolve detector system

The Resolve instrument was launched on board the XRISM observatory in early September 2023. The Resolve spectrometer is based on a high-sensitivity X-ray calorimeter detector system (DS) that has been successfully deployed in many ground and sub-orbital spectrometers. However, the Resolve instrument is the first long-term implementation in space. The instrument will provide essential diagnostics for nearly every class of X-ray emitting objects, from galactic supernova remnants to the outskirts of galaxy clusters, without degradation for spatially extended objects. The Resolve DS consists of a 36-pixel microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the DS demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous bandpass from below 0.3 keV to above 12 keV and a timing precision better than 100μs. An anti-coincidence detector placed directly behind the microcalorimeter array effectively suppresses background. The detector energy-resolution budget included terms for interference from the Resolve cooling system and the spacecraft. Additional terms for energy-scale stability, on-orbit effects, and use of mid-grade events were also included, predicting an end-of-life, on-orbit performance for high- and mid-resolution grade events that meet the requirement of 7 eV FWHM at 6 keV. Here, we discuss the actual on-orbit performance of the Resolve DS and compare this with the performance in pre-flight testing, on-orbit predictions, and the almost identical Hitomi/SXS instrument. We will also discuss the on-orbit gain stability, an assessment of on-orbit interference, and measurements of the on-orbit background.

Astronomy and AstroPhysics