Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microchannel plate detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Comparative lifetesting results for microchannel plates in windowless EUV photon detectors

Microchannel plates (MCPs) from seven manufacturers were subjected to a series of tests to determine their suitability for the Extreme Ultraviolet Explorer satellite. Comparative data are presented for sixteen MCP tandem pairs with channel length to diameter ratios (l/d) ranging from 40:1 to 60:1 and for two saturable (curved channel) MCPs with l/d's of 80:1. Results for MCPs with funnelled channel throats are also discussed. Properties of the MCPs which were monitored include: background count rate, output charge pulse height distribution (PHD), modal gain, PHD full width half maximum (FWHM), and extreme ultraviolet (EUV) photon quantum efficiency. Five detectors were chosen for further lifetime testing consisting of a mild bake to 100 C, and charge extraction to 0.01 coulombs, repeated high voltage cycling and reexposure to one atmosphere conditions. The results of these tests and their implications for the flight detectors are discussed. Erratic events in the detector background were recorded, probably due to field emission from high voltage surfaces or the absorption of water vapor into the electrode following exposure to air. The steps taken to control the detector background are discussed.

Malina, R. F.↗

Dead-time effects in microchannel-plate imaging detectors

The observed counting rates of microchannel plate (MCP) based detectors for high resolution observations of celestial EUV and X-ray sources vary over many orders of magnitude; the counting capability of an individual channel, however, is not high, and is associated with dead-times ranging from 0.1 msec to 1 sec. The dead-time increases with the area illuminated; attention is presently given to laboratory determinations of the count rate characteristics of a MCP detector as a function of illuminated area, and a model is developed for these results' use in the interpretation of space observations.

Zombeck, Martin V.↗

Microchannel plate EUV detectors for the Extreme Ultraviolet Explorer

The design and operating characteristics of the prototype imaging microchannel plate (MCP) detector for the Extreme Ultraviolet Explorer (EUVE) Satellite are discussed. It is shown that this detector has achieved high position resolution performance (greater than 512 x 512 pixels) and has low (less than one percent) image distortion. In addition, the channel plate scheme used has tight pulse height distributions (less than 40 percent FWHM) for UV radiation and displays low (less than 0.2 cnt/sq cm-s) dark background counting rates. Work that has been done on EUV filters in relation to the envisaged filter and photocathode complement is also described.

Siegmund, O. H. W.↗

Microchannel Plate Imaging Detectors for the Ultraviolet

There has been significant progress over the last few years in the development of technologies for microchannel plate imaging detectors in the Ultraviolet (UV). Areas where significant developments have occurred include enhancements of quantum detection efficiency through improved photocathodes, advances in microchannel plate performance characteristics, and development of high performance image readout techniques. The current developments in these areas are summarized, with their applications in astrophysical instrumentation.

Siegmund, O. H. W.↗

Performance of microchannel plate based detectors for <25 keV x rays: Monte Carlo simulations and comparisons with experimental results

We present the results of Monte Carlo simulations of the microchannel plate (MCP) response to x rays in the 250 eV to 25 keV energy range as a function of both x-ray energy and impact angle and their comparisons with the experimental results from the X8A beamline at the National Synchrotron Light Source at Brookhaven National Laboratory. Incoming x rays interact with the lead glass of the microchannel plate, producing photoelectrons. Transport of the photoelectrons is neglected in this model, and it is assumed that photoelectrons deposit all their energy at the point they are created. This deposition leads to the generation of many secondary electrons, some fraction of which diffuse to the MCP pore surface where they can initiate secondary electron cascades in the pore under an external voltage bias. X-ray penetration through multiple MCP pore walls is increasingly important above 5 keV, and the effect of this penetration on MCP performance is studied. In agreement with past measurements, we find that the dependence of MCP sensitivity with angle relative to the pore bias changes from a cotangent dependence to angular independence and then proceeds to a secant dependence as the x-ray energy increases. We also find that with the increasing x-ray energy, the MCP gain sensitivity as a function of bias voltage decreases. The simulations also demonstrate that for x rays incident normal to the MCP surface, spatial resolution shows little dependence on the x-ray energy but degrades with the increasing x-ray energy as the angle of incidence relative to the surface normal increases. This agrees with experimental measurements. Simulation studies have also been completed for MCPs gated with a subnanosecond voltage pulse. In this work, we find that the optical gate profile width increases as the x-ray energy is increased above 5 keV, a consequence of increased x-ray penetration at energies >5 keV. Simulations of the pulsed dynamic range show that the dynamic range varies between ~100 and 1000 depending on x-ray energy and peak voltage.

47 OTHER INSTRUMENTATION↗

Hybrid Ion-Detector/Data-Acquisition System for a TOF-MS

A modified ion-detector/data-acquisition system has been devised to increase the dynamic range of a time-of-flight mass spectrometer (TOF-MS) that, previously, included a microchannel-plate detector and a data-acquisition system based on counting pulses and time-tagging them by use of a time-to-digital converter (TDC). The dynamic range of the TOF-MS was limited by saturation of the microchannel plate detector, which can handle no more than a few million counts per second. The modified system includes (1) a combined microchannel plate/discrete ion multiplier and (2) a hybrid data-acquisition system that simultaneously performs analog current or voltage measurements and multianode single-ion-pulse-counting time-of-flight measurements to extend the dynamic range of a TDC into the regime in which a mass peak comprises multiple ions arriving simultaneously at the detector. The multianode data are used to determine, in real time, whether the detector is saturated. When saturation is detected, the data-acquisition system selectively enables circuitry that simultaneously determines the ion-peak intensity by measuring the time profile of the analog current or voltage detector-output signal.

Burton, William D., Jr.↗

Two-dimensional ultraviolet imagery with a microchannel-plate/resistive-anode detector

An imaging ultraviolet detector has been designed for use with a precision pointed telescope flown on a sounding rocket. Resolution of better than 80 microns over a field of 5 mm has been achieved. The ultraviolet image is converted to electrons at the front surface of a CsI coated chevron microchannel-plate electron multiplier. For each photoelectron, the multiplier produces a burst of about 3,000,000 electrons, which impinges on a tellurium-coated resistive anode with four evaporated hyperbolic readout electrodes. The sizes of the four resulting output pulses are digitized to 10 bit accuracy and telemetered to the ground, where they are divided in pairs to give the x and y coordinates of the photoelectron event. The coordinates are used to generate a picture in real time, and are recorded for computer processing later. The detector was successfully flown in December 1978. Good images of Jupiter and Capella in hydrogen Lyman alpha emission were obtained.

Opal, C. B.↗

Synchrotron radiation calibration of the EUVE variable line-spaced diffraction gratings at the NBS SURF II facility

The Extreme Ultraviolet Explorer (EUVE) has a spectrometer which utilizes variable line-spaced, plane diffraction gratings in the converging beam of a Wolter-Schwarzschild type II mirror. The gratings, microchannel plate detector, and thin film filters have been calibrated with continuum radiation provided by the NBS SURF II facility. These were calibrated in a continuum beam to find edges or other sharp spectral features in the transmission of the filters, quantum efficiency of the microchannel plate detector, and efficiency of the gratings. The details of the calibration procedure and the results of the calibration are presented.

Jelinsky, P.↗

Hex-square moire patterns in imagers using microchannel plates

In electronic imaging detectors using microchannel plates, the mismatch between the pixels on a square mesh and the microchannels on a hexagonal mesh produces moire image defects. Theoretical statistical estimates of the sizes of the microposition offsets and the flat field intensity errors are calculated, showing the trade-off between resolution and position accuracy. A distinction is made between moments of spot images and moments of the single-pixel-response functions. As the resolution between the hex and square meshes is improved, the detector resolution is improved, but at the expense of an about 10 percent moire pattern. These moire patterns will not be properly corrected by dividing by the flat field image.

Lawrence, George M.↗

Nuclear Science Symposium, 27th, and Symposium on Nuclear Power Systems, 12th, Orlando, Fla., November 5-7, 1980, Proceedings

Advances in instrumentation for use in nuclear-science studies are described. Consideration is given to medical instrumentation, computerized fluoroscopy, environmental instrumentation, data acquisition techniques, semiconductor detectors, microchannel plates and photomultiplier tubes, reactor instrumentation, neutron detectors and proportional counters, and space instrumentation.

Martini, M.↗

A rocket-borne faint object spectrograph with a codacon detector

A rocket payload, consisting of a Rowland circle spectrograph with a multi-anode, microchannel plate detector, located at the focus of a 40 cm mirror, has been constructed to observe faint astronomical objects in the 900 to 1800 A spectral region. It can obtain the spectrum of an unreddened, V = 10m OB star with 3 A resolution and + or 3% precision in a 60 second observation.

Lillie, C. F.↗

X-ray instrumentation in astronomy; Proceedings of the Meeting, Cannes, France, December 2-4, 1985

Recent developments in X-ray and EUV astronomical instrumentation are discussed in reviews and reports. Topics examined include optical systems for the NASA Advanced X-ray Astrophysics Facility (AXAF), specialized X-ray systems, advanced X-ray optics, gas-filled X-ray detectors, instrumentation for spectrometry on AXAF, X-ray and EUV spectrometers, microchannel plate detectors, and solid-state detectors.

Culhane, J. L.↗

Wedge and strip image readout systems for photon-counting detectors in space astronomy

EUV and far UV applications of wedge and strip anodes in photon-counting microchannel plate detector systems are discussed in light of performance data obtained as a result of EUV Explorer spacecraft open face detector and FAUST-Spacelab far UV sealed tube sensor calibrations. CsI quantum detection efficiencies of about 80 percent at 114 A and about 40 percent at 600 and 1300 A have been achieved; a position sensitivity of less than 10 microns is demonstrated, and the position resolution, image linearity, background rate, and flat-field characteristics are discussed.

Siegmund, O. H. W.↗

Uniformity and transmission of proportional counter window materials for use with AXAF

The X-ray detection system used to calibrate the Advanced X-ray Astrophysics Facility (AXAF) mirrors will include gas flow and sealed proportional counters. To meet the ultimate 1 percent goal of the calibration project, the transmission and uniformity of the windows must be well known for the soft X-ray wavelengths involved. Various window materials for use with proportional counters are examined for transmission at X-ray wavelengths in the range of 0.1 to 5.9 keV. These include the usual window materials (polypropylene and beryllium), as well as materials only recently employed for detector applications (polyimide and diamond). The transmission uniformity of beryllium at 1.49 keV is examined with a microchannel plate detector, producing a 'shadowgraph' of the window material illuminated with soft X-rays. This technique allows us to investigate nonuniformities on a spatial scale of about .2 mm.

Flanagan, K.↗

Development and testing of a prototype mosaic wedge-and-strip anode detector

A preliminary laboratory study of a prototype mosaic wedge-and-strip anode, a new class of readout system that will furnish large format, high resolution microchannel plate detectors with comparatively simple readout electronics is described. The goals of this study were to demonstrate the linearity of the mosaic anode algorithm, and to verify the predicted resolution performance in a realistic detector configuration. It is found that the nonlinearity introduced at the boundary between two anodes is limited to 50-100 microns. It is also shown that the spatial resolution of the detector is limited mainly by partition noise to about 35 microns (FWHM) at a gain of 2 x 10 to the 7th. A systematic investigation of the charge distribution arriving at the anode is also described. Using the relative charges arriving on the two anodes of the mosaic pattern, the detailed shape of the distribution and its dependence on MCP-anode voltage, MCP voltage, and pulse height are determined. A significant dependence of the profile on pulse height, which can introduce a pulse height dependence to the centroid calculation, particularly near the anode edges is found. Improved anode designs which will achieve the optimal performance are discussed.

Rasmussen, A.↗

High resolution decoding techniques and single-chip decoders for multi-anode microchannel arrays

While the pixel size in a standard multianode microchannel array (MAMA) photon-counting detector is determined by the spacing of the anode array, the factor most fundamentally limiting pixel resolution is the spacing of the channels in the microchannel plate. Detector resolution can be improved by means of digitization followed by a centroiding procedure. The decoding hardware and the techniques for enhanced pixel resolution are presently discussed with a view to the factors of speed and complexity. A single-chip CMOS gate-array implementation of the decoder is devised and compared with existing multichip decoders' performance.

Kasle, David B.↗

Observations of the 3-D distribution of interplanetary electrons and ions from solar wind plasma to low energy cosmic rays

The 3-D Plasma and Energetic Particle instrument on the GGS Wind spacecraft (launched November 1, 1994) is designed to make measurements of the full three-dimensional distribution of suprathermal electrons and ions from solar wind plasma to low energy cosmic rays, with high sensitivity, wide dynamic range, good energy and angular resolution, and high time resolution. Three pairs of double-ended telescopes, each with two or three closely sandwiched passivated ion implanted silicon detectors measure electrons and ions from approximately 20 keV to greater than or equal to 300 keV. Four top-hat symmetrical spherical section electrostatic analyzers with microchannel plate detectors, a large and a small geometric factor analyzer for electrons and a similar pair for ions, cover from approximately 3 eV to 30 keV. We present preliminary observations of the electron and ion distributions in the absence of obvious solar impulsive events and upstream particles. The quiet time electron energy spectrum shows a smooth approximately power law fall-off extending from the halo population at a few hundred eV to well above approximately 100 keV The quiet time ion energy spectrum also shows significant fluxes over this energy range. Detailed 3-D distributions and their temporal variations will be presented.

Lin, R. P.↗