At least 37 records · Page 2

Development, Fabrication, and Testing of a Liquid/Liquid Microchannel Heat Exchanger for Constellation Spacecrafts

Minimizing mass and volume is critically important for space hardware. Microchannel technology can be used to decrease both of these parameters for heat exchangers. Working in concert with NASA, Pacific Northwest National Laboratories (PNNL) has developed a microchannel liquid/liquid heat exchanger that has resulted in significant mass and volume savings. The microchannel heat exchanger delivers these improvements without sacrificing thermal and pressure drop performance. A conventional heat exchanger has been tested and the performance of it recorded to compare it to the microchannel heat exchanger that PNNL has fabricated. The microchannel heat exchanger was designed to meet all of the requirements of the baseline heat exchanger, while reducing the heat exchanger mass and volume. The baseline heat exchanger was designed to have an transfer approximately 3.1 kW for a specific set of inlet conditions. The baseline heat exchanger mass was 2.7 kg while the microchannel mass was only 2.0 kg. More impressive, however, was the volumetric savings associated with the microchannel heat exchanger. The microchannel heat exchanger was an order of magnitude smaller than the baseline heat exchanger (2180cm3 vs. 311 cm3). This paper will describe the test apparatus designed to complete performance tests for both heat exchangers. Also described in this paper will be the performance specifications for the microchannel heat exchanger and how they compare to the baseline heat exchanger.

Hawkins-Reynolds, Ebony↗

Bubble confinement in flow boiling of FC-72 in a ''rectangular'' microchannel of high aspect ratio

Boiling in microchannels remains elusive due to the lack of full understanding of the mechanisms involved. A powerful tool in achieving better comprehension of the mechanisms is detailed imaging and analysis of the two-phase flow at a fundamental level. Boiling is induced in a single microchannel geometry (hydraulic diameter 727 {mu}m), using a refrigerant FC-72, to investigate the effect of channel confinement on bubble growth. A transparent, metallic, conductive deposit has been developed on the exterior of the rectangular microchannel, allowing simultaneous uniform heating and visualisation to be achieved. The data presented in this paper is for a particular case with a uniform heat flux applied to the microchannel and inlet liquid mass flowrate held constant. In conjunction with obtaining high-speed images and videos, sensitive pressure sensors are used to record the pressure drop across the microchannel over time. Bubble nucleation and growth, as well as periodic slug flow, are observed in the microchannel test section. The periodic pressure fluctuations evidenced across the microchannel are caused by the bubble dynamics and instances of vapour blockage during confined bubble growth in the channel. The variation of the aspect ratio and the interface velocities of the growing vapour slug over time, are all observed and analysed. We follow visually the nucleation and subsequent both 'free' and 'confined' growth of a vapour bubble during flow boiling of FC-72 in a microchannel, from analysis of our results, images and video sequences with the corresponding pressure data obtained. (author)

42 ENGINEERING↗

Flow boiling in geometrically modified microchannels

Microchannels are a promising solution for high-heat-flux thermal management scenarios, including high-performance microelectronics cooling and power electronics cooling. However, thermohydraulic instabilities result from the rapid vapor bubble formation. The prior literature has examined several methods, including constricted inlet microchannels, expanding microchannels, and auxiliary jetting microchannels, to mitigate the effect of these instabilities. Computational fluid dynamics and heat transfer (CFD/HT) modeling of the flow boiling phenomena in these microchannel configurations has seen limited examination, and one-to-one numerical comparisons of the different mitigation strategies have not been performed. In the present investigation, CFD/HT analyses using a three-dimensional (3D) volume of fluid model coupled with a phase-change model for the interfacial heat and mass transfer were performed for multiple microchannel configurations (constricted inlet, expanding, and auxiliary jetting microchannels). A benchmark case of a rectangular microchannel was examined to quantify baseline thermohydraulic performance. Results demonstrated slight to significant thermal performance improvements for all cases, and significant pressure benefits for the expanding and jetting cases, consistent with experimental results in the literature. Bubble dynamics and visualization for the baseline and alternative configurations are provided to give insight into their underlying physics, and the differences in performance were investigated and compared with available literature.

Broughton, Justin (ORCID:000000026848457X)↗

High power density fuel cell comprising an array of microchannels

A fuel cell according to one embodiment includes a porous electrolyte support structure defining an array of microchannels, the microchannels including fuel and oxidant microchannels; fuel electrodes formed along some of the microchannels; and oxidant electrodes formed along other of the microchannels. A method of making a fuel cell according to one embodiment includes forming an array of walls defining microchannels therebetween using at least one of molding, stamping, extrusion, injection and electrodeposition; processing the walls to make the walls porous, thereby creating a porous electrolyte support structure; forming anode electrodes along some of the microchannels; and forming cathode electrodes along other of the microchannels. Additional embodiments are also disclosed.

30 DIRECT ENERGY CONVERSION↗

Ultrasonic oscillatory two-phase flow in microchannels

Experimental and numerical investigations are performed to provide an assessment of the transport behavior of an ultrasonic oscillatory two-phase flow in a microchannel. The work is inspired by the flow observed in an innovative ultrasonic fabric drying device using a piezoelectric bimorph transducer with microchannels, where a water-air two-phase flow is transported by harmonically oscillating microchannels. The flow exhibits highly unsteady behavior as the water and air interact with each other during the vibration cycles, making it significantly different from the well-studied steady flow in microchannels. Here, the computational fluid dynamics (CFD) modeling is realized by combing the turbulence Reynolds-averaged Navier-Stokes (RANS) k – ω model with the phase-field method to resolve the dynamics of the two-phase flow. The numerical results are qualitatively validated by the experiment. Through parametric studies, we specifically examined the effects of vibration conditions (i.e., frequency and amplitude), microchannel taper angle, and wall surface contact angle (i.e., wettability) on the flow rate through the microchannel. The results will advance the potential applications where oscillatory or general unsteady microchannel two-phase flows may be present.

42 ENGINEERING↗

Addressing Two-Phase Flow Maldistribution in Microchannel Heat and Mass Exchangers

Multiphase flow phenomena in single micro and minichannels have been widely studied. Characteristics of two-phase flow through a large array of microchannels are investigated here. An air–water mixture is used to represent the two phases flowing through a microchannel array representative of those employed in practical applications. Flow distribution of the air and water flow across 52 parallel microchannels of 0.4 mm hydraulic diameter is visually investigated using high-speed photography. Two microchannel configurations are studied and compared, with mixing features incorporated into the second configuration. Slug and annular flow regimes are observed in the channels. Void fractions and interfacial areas are calculated for each channel from these observations. The flow distribution is tracked at various lengths along the microchannel array sheets. Statistical distributions of void fraction and interfacial area along the microchannel array are measured. The design with mixing features yields improved flow distribution. Void fraction and interfacial area change along the length of the second configuration, indicating a change in fluid distribution among the channels. The void fraction and interfacial area results are used to predict the performance of different microchannel array configurations for heat and mass transfer applications. Results from this study can help inform the design of compact thermal-fluid energy systems.

Engineering↗

Field-effect Flow Control in Polymer Microchannel Networks

A new Bio-MEMS electroosmotic flow (EOF) modulator for plastic microchannel networks has been developed. The EOF modulator uses field-effect flow control (FEFC) to adjust the zeta potential at the Parylene C microchannel wall. By setting a differential EOF pumping rate in two of the three microchannels at a T-intersection with EOF modulators, the induced pressure at the intersection generated pumping in the third, field-free microchannel. The EOF modulators are able to change the magnitude and direction of the pressure pumping by inducing either a negative or positive pressure at the intersection. The flow velocity is tracked by neutralized fluorescent microbeads in the microchannels. The proof-of-concept of the EOF modulator described here may be applied to complex plastic ,microchannel networks where individual microchannel flow rates are addressable by localized induced-pressure pumping.

Sniadecki, Nathan↗

Scanning Microscopes Using X Rays and Microchannels

Scanning microscopes that would be based on microchannel filters and advanced electronic image sensors and that utilize x-ray illumination have been proposed. Because the finest resolution attainable in a microscope is determined by the wavelength of the illumination, the xray illumination in the proposed microscopes would make it possible, in principle, to achieve resolutions of the order of nanometers about a thousand times as fine as the resolution of a visible-light microscope. Heretofore, it has been necessary to use scanning electron microscopes to obtain such fine resolution. In comparison with scanning electron microscopes, the proposed microscopes would likely be smaller, less massive, and less expensive. Moreover, unlike in scanning electron microscopes, it would not be necessary to place specimens under vacuum. The proposed microscopes are closely related to the ones described in several prior NASA Tech Briefs articles; namely, Miniature Microscope Without Lenses (NPO-20218), NASA Tech Briefs, Vol. 22, No. 8 (August 1998), page 43; and Reflective Variants of Miniature Microscope Without Lenses (NPO-20610), NASA Tech Briefs, Vol. 26, No. 9 (September 2002) page 6a. In all of these microscopes, the basic principle of design and operation is the same: The focusing optics of a conventional visible-light microscope are replaced by a combination of a microchannel filter and a charge-coupled-device (CCD) image detector. A microchannel plate containing parallel, microscopic-cross-section holes much longer than they are wide is placed between a specimen and an image sensor, which is typically the CCD. The microchannel plate must be made of a material that absorbs the illuminating radiation reflected or scattered from the specimen. The microchannels must be positioned and dimensioned so that each one is registered with a pixel on the image sensor. Because most of the radiation incident on the microchannel walls becomes absorbed, the radiation that reaches the image sensor consists predominantly of radiation that was launched along the longitudinal direction of the microchannels. Therefore, most of the radiation arriving at each pixel on the sensor must have traveled along a straight line from a corresponding location on the specimen. Thus, there is a one-to-one mapping from a point on a specimen to a pixel in the image sensor, so that the output of the image sensor contains image information equivalent to that from a microscope.

Wang, Yu↗

High power density fuel cell comprising an array of microchannels

A phosphoric acid fuel cell according to one embodiment includes an array of microchannels defined by a porous electrolyte support structure extending between bottom and upper support layers, the microchannels including fuel and oxidant microchannels; fuel electrodes formed along some of the microchannels; and air electrodes formed along other of the microchannels. A method of making a phosphoric acid fuel cell according to one embodiment includes etching an array of microchannels in a substrate, thereby forming walls between the microchannels; processing the walls to make the walls porous, thereby forming a porous electrolyte support structure; forming anode electrodes along some of the walls; forming cathode electrodes along other of the walls; and filling the porous electrolyte support structure with a phosphoric acid electrolyte. Additional embodiments are also disclosed.

25 ENERGY STORAGE↗

Impact of aspect ratio on flow boiling of water in rectangular microchannels

In this paper we focus on the impact of varying the aspect ratio of rectangular microchannels, on the overall pressure drop involving water boiling. An integrated system comprising micro-heaters, sensors and microchannels has been realized on (110) silicon wafers, following CMOS compatible process steps. Rectangular microchannels were fabricated with varying aspect ratios (width [W] to depth [H]) but constant hydraulic diameter of 142{+-}2{mu}m and length of 20 mm. The invariant nature of the hydraulic diameter is confirmed through two independent means: physical measurements using profilometer and by measuring the pressure drop in single-phase fluid flow. The experimental results show that the pressure drop for two-phase flow in rectangular microchannels experiences minima at an aspect ratio of about 1.6. The minimum is possibly due to opposing trends of frictional and acceleration pressure drops, with respect to aspect ratio. In a certain heat flux and mass flux range, it is observed that the two-phase pressure drop is lower than the corresponding single-phase value. This is the first study to investigate the effect of aspect ratio in two-phase flow in microchannels, to the best of our knowledge. The results are in qualitative agreement with annular flow model predictions. These results improve the possibility of designing effective heat-sinks based on two-phase fluid flow in microchannels. (author)

42 ENGINEERING↗

Measurement of Particulate Retention in Microchannel Flows

The purpose of this study was to explore the flow rates and aerosol retention of an engineered microchannel with characteristic dimensions similar to those of stress corrosion cracks (SCCs) that could form in dry cask storage systems (DCSS) for spent nuclear fuel. Additionally, pressure differentials covering the upper limit of commercially available DCSS were studied. Given the scope and resources available, these data sets should be considered preliminary and are intended to demonstrate a new capability to characterize SCC under well-controlled boundary conditions. The gap of the microchannel tested was 28.9 gm (0.00110 in.), the width was 12.7 mm (0.500 in.), and the length was 8.86 mm (0.349 in.). Over a nine-hour period, the average mass concentration upstream of the microchannel was 0.048 mg/m 3 while the average concentration downstream was 0.030 mg/m 3 . By the end of the test, the mass of aerosols that entered the test section upstream of the microchannel was 0.207 mg and the mass of aerosols that exited the microchannel was 0.117 mg. Therefore, 44% of the aerosols available for transmission was retained upstream of microchannel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Enabling Microliquid Chromatography by Microbead Packing of Microchannels

The microbead packing is the critical element required in the success of on-chip microfabrication of critical microfluidic components for in-situ analysis and detection of chiral amino acids. In order for microliquid chromatography to occur, there must be a stationary phase medium within the microchannel that interacts with the analytes present within flowing fluid. The stationary phase media are the microbeads packed by the process discussed in this work. The purpose of the microliquid chromatography is to provide a lightweight, low-volume, and low-power element to separate amino acids and their chiral partners efficiently to understand better the origin of life. In order to densely pack microbeads into the microchannels, a liquid slurry of microbeads was created. Microbeads were extracted from a commercially available high-performance liquid chromatography column. The silica beads extracted were 5 microns in diameter, and had surface coating of phenyl-hexyl. These microbeads were mixed with a 200- proof ethanol solution to create a microbead slurry with the right viscosity for packing. A microfilter is placed at the outlet via of the microchannel and the slurry is injected, then withdrawn across a filter using modified syringes. After each injection, the channel is flushed with ethanol to enhance packing. This cycle is repeated numerous times to allow for a tightly packed channel of microbeads. Typical microbead packing occurs in the macroscale into tubes or channels by using highly pressurized systems. Moreover, these channels are typically long and straight without any turns or curves. On the other hand, this method of microbead packing is completed within a microchannel 75 micrometers in diameter. Moreover, the microbead packing is completed into a serpentine type microchannel, such that it maximizes microchannel length within a microchip. Doing so enhances the interactions of the analytes with the microbeads to separate efficiently amino acids and amino acid enantiomers.

Balvin, Manuel↗

Enabling Microliquid Chromatography by Microbead Packing of Microchannels

The microbead packing is the critical element required in the success of on-chip microfabrication of critical microfluidic components for in-situ analysis and detection of chiral amino acids. In order for microliquid chromatography to occur, there must be a stationary phase medium within the microchannel that interacts with the analytes present within flowing fluid. The stationary phase media are the microbeads packed by the process discussed in this work. The purpose of the microliquid chromatography is to provide a lightweight, low-volume, and low-power element to separate amino acids and their chiral partners efficiently to understand better the origin of life. In order to densely pack microbeads into the microchannels, a liquid slurry of microbeads was created. Microbeads were extracted from a commercially available high-performance liquid chromatography column. The silica beads extracted were 5 microns in diameter, and had surface coating of phenyl-hexyl. These microbeads were mixed with a 200- proof ethanol solution to create a microbead slurry with the right viscosity for packing. A microfilter is placed at the outlet via of the microchannel and the slurry is injected, then withdrawn across a filter using modified syringes. After each injection, the channel is flushed with ethanol to enhance packing. This cycle is repeated numerous times to allow for a tightly packed channel of microbeads. Typical microbead packing occurs in the macroscale into tubes or channels by using highly pressurized systems. Moreover, these channels are typically long and straight without any turns or curves. On the other hand, this method of microbead packing is completed within a microchannel 75 micrometers in diameter. Moreover, the microbead packing is completed into a serpentine type microchannel, such that it maximizes microchannel length within a microchip. Doing so enhances the interactions of the analytes with the microbeads to separate efficiently amino acids and amino acid enantiomers.

Balvin, Manuel↗

Rate capability and magnetic field tolerance measurements of fast timing microchannel plate photodetectors

Microchannel plate photodetectors provide both picosecond time resolution and sub-millimeter position resolution, making them attractive photosensors for particle identification detectors of a future U.S. Electron Ion Collider. In this paper, we have tested the rate capability and magnetic field tolerance of 6 x 6 cm 2 microchannel plate photodetectors fabricated at Argonne National Laboratory. The microchannel plate photodetector is designed as a low-cost all-glass vacuum package with a chevron pair stack of next-generation microchannel plates functionalized by atomic layer deposition. The rate capability test was performed using Fermilab’s 120 GeV/c primary proton beam, and the magnetic field tolerance test was performed using a solenoid magnetic with tunable magnetic field strength up to 4 T. Finally, the measured gain of the microchannel plate photodetector is stable up to 75 kHz/cm 2 and varies depending on the applied magnetic field strength and the rotation angle relative to the magnetic field direction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AN INTERNAL CONVECTIVE HEATING TECHNIQUE FOR DIFFUSION BONDING ARRAYED MICROCHANNEL ARCHITECTURES

Diffusion bonding cycle times can be a large factor in the production cost of metal microchannel devices. The challenge is to significantly minimize bonding cycle times through rapid heating and cooling within the bonding process. A novel method is described which takes advantage of the internal flow passages within microchannel devices for convective heat transfer during the bonding process. The internal convective heating (ICH) technique makes use of heated inert gas to provide the microchannel assembly with rapid and uniform heat input. Results demonstrate that the ICH technique is feasible, capable of producing microchannels with higher dimensional integrity and shorter bonding cycle times than traditional vacuum hot press methods. Results suggest that this may be due to smaller thermal gradients within microchannel devices during the ICH bonding cycle.

42 ENGINEERING↗

Development of HPWH System Model, Using All Microchannel Heat Exchangers

In this report, 24-hour energy factor (EF) and first-hour draw rating (FHR) simulations were conducted on two heat pump water heater systems (HPWHs), one using a fin-and-tube evaporator and wrapped-tank condenser coil with D-shape tubes, and the other using a micro-channel evaporator and wrapped-tank condenser coil with microchannel tubes. Alternative refrigerants as drop-in replacements of R-134a were evaluated, including R-1234yf, R-1234ze(E), propane (R-290), R-450A and R-513A. The results are summarized below: 1.Microchannel heat exchangers can decrease the system charge down to 30% relative to fin-and-tube evaporator and wrapped-tank D tubes.2.Having the same contact surface area to the water tank and evaporator frontal flow area, the system using microchannel heat exchangers (MHXs) results in 5% efficiency degradation. Due to the very small cross-sectional flow area of a microchannel tube, MHXs tend to have multiple parallel tubes to restrict the refrigerant pressure drop. The parallel pattern can’t utilize the water temperature stratification as effectively as the D-shape tubes, which are arranged in one or two circuits and counter flow to the water stratification. 3.Refrigerant drop-in system simulations were conducted for R-1234yf, R-1234ze(E), propane, R450A and R513A in comparison to R-134a. Among the alternatives, propane has the largest volumetric capacity, which results in shortest HPWH run time and highest first-hour rating. Propane leads to the smallest energy factor because its largest volumetric capacity overloads the heat exchangers. R-1234ze(E) has the smallest volumetric capacity, highest energy factor, but smallest first-hour rating. R-1234yf, R-450A and R-513A achieve similar performance indices as R-134a. 4.Propane requires the least refrigerant mass (45% relative to R-134a). If a wrapped-tank microchannel condenser and microchannel evaporator are used, the required system charge can be limited below 150 grams, which makes it feasible to use propane for domestic HPWH.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multiple-Dynode-Layer Microchannel Plate

Improved microchannel-plate electron image amplifier made of stack of discrete microchannel-plate layers. New plates easier to manufacture because no need to etch long, narrow holes, to draw and bundle thin glass tubes, or to shear plates to give microchannels curvatures necessary for reduction of undesired emission of ions. Discrete dynode layers stacked with slight offset from layer to layer to form microchannel plate with curved channels. Provides for relatively fast recharging of microchannel dynodes, with consequent enhancement of performance.

Woodgate, Bruce E.↗

Experimental study of the maximum resolution and packing density achievable in sintered and non-sintered binder-jet 3D printed steel microchannels

Developing high resolution 3D printed metallic microchannels is a challenge especially when there is an essential need for high packing density of the primary material. While high packing density could be achieved by heating the structure to the sintering temperature, some heat sensitive applications require other strategies to improve the packing density of primary materials. In this study the goal is to develop high green or pack densities microchannels on the scale of 2-300 microns which have a robust mechanical structure. Binder-jet 3D printing is an additive manufacturing process in which droplets of binder are deposited via inkjet into a bed of powder. By repeatedly spreading thin layers of powder and depositing binder into the appropriate 2D profiles, complex 3D objects can be created one layer at time. Microchannels with features on the order of 500 microns were fabricated via binder jetting of steel powder and then sintered and/or infiltrated with a secondary material. The average particle size of the steel powder was varied along with the droplet volume of the inkjet-deposited binder. The resolution of the process, packing density of the primary material, the subsequent features sizes of the microchannels, and the overall microchannel quality were characterized as a function of particle size distribution, droplet sizes and heat treatment temperatures.

Elliott, Amy M↗