Search NASA⌕ Search

SEARCH · Search NASA

Results for “Micron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Azimuthally averaged radial S(sub 100 microns)/S(sub 60 microns) dust color temperatures in spiral galaxies

The IRAS S(sub 100 micron)/S(sub 60 micron) dust color temperature profiles are presented for two nearby spiral galaxies M 101 and M 81. The radial dust temperature profiles provided an important constraint on the origin of the far-infrared luminosity. The observed dust temperature is compared with that expected for diffuse interstellar dust heated by the general interstellar radiation field within each galaxy. The implications for the contribution of cirrus to the far-infrared luminosity of M 101 and M 81 are discussed.

Devereux, Nick A.↗

Performance of an X-Ray Microcalorimeter with a 240 Micron Absorber and a 50 Micron TES Bilayer

We have been developing superconducting transition-edge sensor (TES) microcalorimeters for a variety of potential astrophysics missions, including Athena. The X-ray Integral Field Unit (X-IFU) instrument on this mission requires close-packed pixels on a 0.25 mm pitch, and high quantum efficiency between 0.2 and 12 keV. The traditional approach within our group has been to use square TES bilayers on molybdenum and gold that are between 100 and 140 microns in size, deposited on silicon nitride membranes to provide a weak thermal conductance to a 50 mK heat bath temperature. It has been shown that normal metal stripes on top of the bilayer are needed to keep the unexplained noise at a level consistent with the expected based upon estimates for the non-equilibrium non-linear Johnson noise.In this work we describe a new approach in which we use a square TES bilayer that is 50 microns in size. While the weak link effect is much stronger in this size of TES, we have found that excellent spectral performance can be achieved without the need for any normal metal strips on top of the TES. A spectral performance of 1.58 eV at 6 KeV has been achieved, the best resolution seen in any of our devices with this pixel size. The absence of normal metal stripes has led to more uniform transition shapes, and more reliable excellent spectral performance. The smaller TES size has meant that that the thermal conductance to the heat bath, determined by the perimeter length of the TES and the membrane thickness, is lower than on previous devices, and thus has a lower count rate capability. This is an advantage for low count-rate applications where the slower speed enables easier multiplexing in the read-out, thus potential higher multiplexing factors. In order to recover the higher count rate capabilities, a potential path exits using thicker silicon nitride membranes to increase the thermal conductance to the heat bath.

Miniussi, Antoine R.↗

The Apollo 16 regolith - Comparative petrology of the greater than 20 micron and 20-10 micron soil fractions, lateral transport and differential volatilization

The present investigation is concerned with questions regarding a preferential transport of finer-grained material on the lunar surface. Attention is also given to a possible appearance of volatization effects in the case of fine-grained glass beads. It is found that preferential lateral transport of fine-grained material is not efficient over the distances required to introduce mare material into the Apollo-16 (A-16) lunar highlands. The presence of granitic glasses found in the 20-10 micron fractions is attributed to comminution of mesostasis. The composition of mesostasis and the silica-rich phases contained within it reported by other investigators supports this conclusion. No evidence could be found of increased volatilization in the finer grained samples.

Kempa, M. J.↗

Laser materials for the 0.67-microns to 2.5-microns range

Basic requirements for obtaining injection laser action in III-V semiconductors are discussed briefly. A detailed review is presented of materials suitable for lasers emitting at 0.67, 1.44, 1.93, and 2.5 microns. A general approach to the problem is presented, based on curves of materials properties published by Sasaki et al. It is also shown that these curves, although useful, may need correction in certain ranges. It is deduced that certain materials combinations, either proposed in the literature or actually tried, are not appropriate for double heterostructure lasers, because the refractive index of the cladding material is higher than the index of the active material, thus resulting in no waveguiding, and high threshold currents. Recommendations are made about the most promising approach to the achievement of laser action in the four wavelengths mentioned above.

Toda, Minoru↗

Pulsed coherent solid-state 1.06-micron and 2.1-micron laser radar systems for remote velocity measurement

A low average power, pulsed, solid-state, 1.06-micron coherent laser radar (CLR) for range and velocity measurements of atmospheric and hard targets has been developed. The system has been operating at a field test site near Boulder, CO since September, 1988. Measurements have been taken on moving targets such as atmospheric aerosol particles, belt sanders, spinning disks, and various stationary targets. The field measurements have shown that this system exhibits excellent velocity measurement performance. A fast-tuning CW Nd:YAG oscillator has also been developed which has a frequency tuning range of greater than 30 GHz (which spans a target radial velocity range of over 16 km/s) and a tuning speed greater than 30 GHz/ms.

Henderson, Sammy W.↗

Theoretical interpretation of the Venus 1.05-micron CO2 band and the Venus 0.8189-micron H2O line.

The synthetic-spectrum technique was used in the analysis. The synthetic spectra were constructed with a model which takes into account both isotropic scattering and the inhomogeneity in the Venus atmosphere. The Potter-Hansen correction factor was used to correct for anisotropic scattering. The synthetic spectra obtained are, therefore, the first which contain all the essential physics of line formation. The results confirm Potter's conclusion that the Venus cloud tops resemble terrestrial cirrus or stratus clouds in their scattering properties.

Regas, J. L.↗

Detection of CO J = 21-20 /124.2 microns/ and J = 22-21 /118.6 microns/ emission from the Orion nebula

The first observation of far-infrared molecular line emission from the interstellar medium is reported. Strong emission from the J = 21-20 and J = 22-21 rotational transitions of carbon monoxide was detected in the Kleinmann-Low/shocked H2 region of the Orion Molecular Cloud. The results imply that the region is optically thin in these lines and that much of the carbon is in the form of CO. This work also represents the first use of an antimony-doped germanium photoconductor in an astronomical application.

Watson, D. M.↗

The galactic center - 16-30 micron observations and the 18 micron extinction

Within the galactic center, ionized gas, stars, and heated dust are in close proximity to each other. Observations of the galactic center were made during two flight series on NASA aircraft flying at altitudes of more than 12 km. In both series the instrument used was a 10-channel liquid helium cooled grating spectrometer. Three 16-30 micrometers continuum spectra are presented along with two-color scans of the galactic center. No 18.71 micrometers line emission has been detected from Sgr A West. This is consistent with large dust extinction and normal S III/H II abundances. All three 16-30 micrometers continuum spectra show a broad depression centered at about 18 micrometers. This observation is attributed to absorption by cold silicate dust grains. The characteristics of a silicate model are discussed.

Mccarthy, J. F.↗