Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microphonics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

LCLS-II and HE Cryomodule Microphonics at CMTF at Fermilab

Microphonics causes the cavity to detune. This study discusses the microphonics of 16 cryomodules, 14 for LCLS-II and 2 for LCLS-II HE tested at CMTF. The peak detuning, as well as the RMS detuning for each cryomodule, will be discussed. For each cryomodule, the data was taken with enough soaking time to prevent any thermalization effects which can show up in the detuning. Each data capture taken was 30 minutes or longer and sampled at 1 kHz.

43 PARTICLE ACCELERATORS↗

Microphonics Passive Damping

Different types of external loads on the resonator walls predetermine the main working conditions of the SRF cavities. The most important of them are very high electromagnetic fields that result in strong Lorentz forces and the pressure on cavity walls from the helium tank that also deforms the cavity shape. For pulsed operation, the Lorentz forces usually play the decisive role for the cavity design. For CW operation, the liquid helium vessel pressure instability even for 2K operations is the source of large microphonics. All deformations resulting from any type of external loads on cavity walls lead to shifts in the working RF frequency in the range of hundreds of kHz. Taking into account high Q-factor of SC cavities such a large frequency shift takes the cavity out of operation. Here we present and discuss the achievements and problems of microphonics passive damping in different type SRF cavities.

43 PARTICLE ACCELERATORS↗

Preliminary Investigation in removing microphonic noise from nuclear detectors

Developing tools to perform nuclear spectroscopy using unattended sensor nodes would greatly enhance LANL’s ability to address nuclear material identification and detection challenges in the non‐proliferation and treaty verification domains. High purity germanium crystals are the gold standard detector used for performing high‐resolution nuclear spectroscopy. In order to function properly, these crystals must be brought down to liquid nitrogen temperatures. In practice the required temperature is typically achieved using liquid nitrogen dewars. The shortcoming with this strategy is that the dewars must be refilled roughly every week. This requirement is not practical for applications that require collecting nuclear spectroscopy data in remote/inaccessible areas. An alternative is to use a piston‐driven cryocooler to achieve liquid nitrogen temperatures. Piston‐driven cryocoolers, can operate unattended, but the microphonic noise induced by the vibrations produced by these coolers causes the resolution of the spectroscopic measurements to severely degrade, making identification of nuclear materials significantly more difficult. The goal of this research effort was to reduce the effects of microphonic noise.

42 ENGINEERING↗

Frequency stability of the SRF cavities (microphonics)

There are several proposed experiments to search for Dark Matter that will utilize SRF cavities submerged into liquid Helium. Extremely narrow bandwidth of SRF cavities (<1 Hz) and requirements for cavity frequency stability will be obligated special measures to mitigate any vibrations from external sources that will be penetrated and re-tuned cavity. In the talk recent FNAL experience of measuring microphonics of SRF cavities used for Dark Photon experiment will be presented. FNAL’s program to mitigate SRF cavity microphonics (in passive and active way) will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An OVERVIEW of MICROPHONICS in CEBAF and CURRENT MODERATION TECHNIQUES

Superconducting RF (SRF) structures are susceptible to frequency detuning from external vibrations and modal mechanical resonances in the structure. These small disturbances, known as microphonics, require additional RF power in CW accelerating structures since the frequency is constantly shifting. In the Jefferson Lab CEBAF accelerator, time and frequency data of this frequency shift have been recorded for many years, allowing a retrospective analysis of different microphonics-mitigation techniques. Some of these techniques are specific to the design of each CEBAF cryomodule, for example implementing BNNT damping material on the cavity string. Other techniques are universal such as affixing vacuum lines and reinforcing waveguide structures.

Powers, Tom↗

Closed Loop Testing of Microphonics Algorithms Using a Cavity Emulator

An analog crystal filter based cavity emulator is modified with reverse biased varactor diodes to provide a tuning range of around 160 Hz. The piezo drive voltage of the resonance controller is used to detune the cavity through the bias voltage. A signal conditioning and summing circuit allows the introduction of microphonics disturbance from a signal source or using real microphonics data from cavity testing. This setup is used in closed loop with a cavity controller and resonance controller to study the effectiveness of resonance control algorithms suitable for superconducting cavities.

43 PARTICLE ACCELERATORS↗

The Acoustic Emission signal acquired by the microphones placed in the CABRI test device along the fourteen last R.I.A. experiments: an example of reproducible research in nuclear science

The CABRI facility is an experimental nuclear reactor of the French Atomic Energy Commission. It is located at the Cadarache Research Centre in southern France and it is designed to act as a support to the French nuclear infrastructure. The purpose of the new testing programme termed, 'CABRI International Programme' (CIP) is to study the behaviour of PWR-type fuel rods at high burnup, equipped with an 'advanced' cladding, under Reactivity Initiated Accident (RIA) conditions (such as the scenario of a control rod ejection). Within the framework of this programme, piloted and funded by the French Institute of Nuclear Radioprotection and Safety (IRSN), ten tests are to be conducted with a frequency of two tests per year. The LPRE laboratory of the CEA which is in charge of the Preparation, realisation and breakdown of the test results studies the possibility to set up a new test analysis based on the processing of signals coming from sensors placed within the test equipment. During the experimental phase, the behaviour of the fuel element generates acoustic waves which can be detected by two microphones placed upstream and downstream of the test device. Studies showed the interest to realize temporal and spectral analyses on these signals by showing the existence of signatures which can be correlated with physical phenomena as the rod failure or the test shutdown (i.e. scram). The work presented in this article results from the will to consolidate these studies. Since the main phenomenon to be tracked is the fuel rod failure, the aim would be to highlight specific events which would have been precursors of the rod failure in order to use in the future these signals for further interpretation. Such an antecedent works resumption leads to a better understanding of the experimental needs and constitutes a good initial state to prepare the new very fast digital data acquisition systems. Although all the raw data are accessible in the form of text files, analyses and graphics representations were not straightforward to reproduce from the ancient studies since that, on one hand, people who were in charge of the original work left the laboratory and on the other hand because it is not easy when the time passes, even with our own work, to be able to remember the steps of data manipulations and the exact setup: - During the ancient experiments the use of analog data acquisition systems required to digitize tapes to be able to realize computer treatments. That had had for consequence to lose the initial dating. This one must be correctly edited to do temporal comparisons. - Analyses require functions for calculations whose parameters has to be well-known to reach the same results. We thus wished to manage our workflow in the idea that it can be easily reproducible on all the experiments. The object of the work presented in this article was to put in practice this strong bind between the data, treatments and generation of the document in order not to hesitate to do the iteration principle in action. We do not have to be afraid by the data driven analyses. According to the philosophy of the literate programming, the text of the technical document is woven with the computer code that produces all the printed output as tables, graphs for the study eliminating hence the unrealistic cut and paste. This difficulty is not specific to the nuclear domain. For many years, researchers have been worked out solutions to this mundane issue. And, presently, new technologies and high-level programming languages offer us actual answers. We will firstly present the tools applied in our laboratory to implement this workflow, then we will describe the global perception carried out to continue the study of the Acoustic Emission signals recorded by the two microphones during the fourteen last CABRI R.I.A. test.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An active drop counting device using condenser microphone for superheated emulsion detector

An active device for superheated emulsion detector is described. A capacitive diaphragm sensor or condenser microphone is used to convert the acoustic pulse of drop nucleation to electrical signal. An active peak detector is included in the circuit to avoid multiple triggering of the counter. The counts are finally recorded by a microprocessor based data acquisition system. Genuine triggers, missed by the sensor, were studied using a simulated clock pulse. The neutron energy spectrum of {sup 252}Cf fission neutron source was measured using the device with R114 as the sensitive liquid and compared with the calculated fission neutron energy spectrum of {sup 252}Cf. Frequency analysis of the detected signals was also carried out.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Electronic damping of microphonics in superconducting resonators of a continuous wave linac

The paper presents an implementation technique to damp the microphonics in superconducting resonators utilizing the coupling between the electromagnetic and the mechanical modes of a resonator. In the technique used the resonant frequency variations are fed back to modulate the field amplitude through a suitable transfer function. Of the two transfer functions used in the experiments, one emulates a derivative action and is placed in a negative feedback configuration. The other transfer function is essentially a parallel combination of second order low pass filters and is used in a positive feedback configuration. Experiments with the Quarter Wave resonators of IUAC, New Delhi linac demonstrate that the damping of some of the modes increases significantly with the introduction of this feedback leading to a reduction in power required for field stabilization and quieter operation of the RF control system.

43 PARTICLE ACCELERATORS↗

Hearing carrier-envelope offset frequency and phase in air with a microphone

Attosecond science and frequency metrology rely on the precise measurement and control of the laser pulse waveform, a feat traditionally achieved using optoelectronic techniques. In this study, we conducted a laser-induced acoustic experiment in air ionized by carrier-envelope phase (CEP)-stabilized sub-4 fs pulses. Our results reveal that the acoustic signal exhibits CEP dependence in few-cycle pulses, primarily through amplitude modulation from laser-driven ionization. This optoacoustic phenomenon is, to the best of our knowledge, a novel phenomenon that enables not only the measurement of the carrier-envelope offset frequency but also the direct characterization of the waveform of optical pulses through a microphone. Our study highlights the potential of laser-induced acoustic waves for advancing ultrafast science.

Han, Meng [Kansas State University, Manhattan, KS ↗

Passive Microphonics Mitigation during LCLS-II Cryomodule Testing at Fermilab

The LCLS-II project calls for cryomodule production and testing at both Fermilab and JLab. Due to low beam loading and high cavity quality factor, the designed peak detuning specification is 10 Hz. Initial testing showed peak detuning up to 150 Hz with a complex and varying time-structure, showing both fast (1-2 second) and slow (1-2 hour) drifts in amplitude and spectrum. Extensive warm and cold testing showed Thermoacoustic Oscillations in the cryogenic valves were the primary source of the microphonics. This was mitigated by valve wipers and valve re-plumbing, resulting in a greatly improved cavity detuning environment. Additional modifications were made to the cavity mechanical supports and Fermilab test stand to improve detuning performance. These modifications and testing results will be presented.

43 PARTICLE ACCELERATORS↗

Microphonics Studies at STC in Fermilab

The spoke test cryostat is used to qualify the 325 MHz single spoke resonators at Fermilab (FNAL). During these tests a large detuning on the cavity was observed. The data acquisition for continuous captures were based on measurements from the piezoelectric actuators. A com-parison of the cavity vibrations measured with RF signal from the cavity and piezoelectric actuator signals are shown. The effects of microphonics on the cavity are discussed.

43 PARTICLE ACCELERATORS↗

A reactive ferroelectric tuner for microphonics compensation

Jefferson Lab (JLab) is actively pursuing an extensive research program focused on developing advanced Nb₃Sn superconducting technology for particle accel-eration. Due to the brittle nature of Nb₃Sn coatings, a Ferroelectric Tuner (FRT) currently represents the most viable approach for microphonics compensation in these next-generation cavities. We suggest a novel, fast-responding FRT integrated directly into the main coupler, eliminating the need for an additional RF port. Leveraging a unique RF design based on a magic-T configuration, this advanced FRT will enable micro-phonics compensation in the ±30 Hz range without undesirable changes to the external quality factor.

Accelerator Physics↗

Thermal-stress modeling of an optical microphone at high temperature.

To help determine the capability range of a MEMS optical microphone design in harsh conditions computer simulations were carried out. Thermal stress modeling was performed up to temperatures of 1000 C. Particular concern was over stress and strain profiles due to the coefficient of thermal expansion mismatch between the polysilicon device and alumina packaging. Preliminary results with simplified models indicate acceptable levels of deformation within the device.

42 ENGINEERING↗

Analyzing data from a PDV microphone

Photon Doppler Velocimetry (PDV) is used at Los Alamos National Laboratory to measure extremely fast velocities (on the order of 0.01 - 5 km/s) of projectiles during material testing procedures. This kind of testing is extremely important to understand how materials behave in extreme conditions (such as in nuclear explosions). PDV data is created by summing an incident beam with a Doppler shifted reflection, forming a beat frequency. The beat frequency is directly proportional to the velocity of the reflecting surface. We explored a new way of using PDV: measuring slow velocities (less than 1 m/s). The principle method we used was to measure vibrations in a Mylar sheet due to incident sound waves. I analyzed these files using both my own coding as well as a program designed at NSTec for this purpose. Analysis included performing Fourier Transforms, extracting velocity as a function of time, and playing the velocity function through a speaker to recreate the initial sound. We were able to create a successful microphone, though playback quality was poor. The limiting factor was the low velocity of the Mylar sheet, which was about 0.2 m/s. Other methods are now being explored to extract velocity data in a more efficient manner. During this project I gained extensive experience in programming, data analysis, problem solving, and communication. I learned that one must be creative in order to solve complex problems, approaching them from various angles. I also gained a lot of practice working on a team, which consisted of a high school student, another college intern, and our mentor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Downhole Microphone Operation Plan

This document describes the setup and operation of an infrasound microphone manifold designed to capture acoustic waves in the shot borehole.

42 ENGINEERING↗

A reactive ferroelectric tuner for microphonics compensation

Jefferson Lab (JLab) is actively pursuing an extensive research program focused on developing advanced Nb₃Sn superconducting technology for particle accel-eration. Due to the brittle nature of Nb₃Sn coatings, a Ferroelectric Tuner (FRT) currently represents the most viable approach for microphonics compensation in these next-generation cavities. We suggest a novel, fast-responding FRT integrated directly into the main coupler, eliminating the need for an additional RF port. Leveraging a unique RF design based on a magic-T configuration, this advanced FRT will enable micro-phonics compensation in the ±30 Hz range without undesirable changes to the external quality factor.

Accelerator Physics↗

Ultrasonic microphone and ultrasonic acoustic radio

This disclosure provides systems, methods, and apparatus related to an ultrasonic microphone and an ultrasonic acoustic radio. In one aspect a system includes a transmitter and a receiver. The receiver comprises a membrane. The membrane comprises 5 a single layer or multiple layers of a two-dimensional material. The receiver is operable to receive sound waves in a frequency range, with the frequency range being the ultrasonic frequency range

42 ENGINEERING↗