Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microscopy, Fluorescence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Quantitative high dynamic range beam profiling for fluorescence microscopy

Modern developmental biology relies on optically sectioning fluorescence microscope techniques to produce non-destructive in vivo images of developing specimens at high resolution in three dimensions. As optimal performance of these techniques is reliant on the three-dimensional (3D) intensity profile of the illumination employed, the ability to directly record and analyze these profiles is of great use to the fluorescence microscopist or instrument builder. Though excitation beam profiles can be measured indirectly using a sample of fluorescent beads and recording the emission along the microscope detection path, we demonstrate an alternative approach where a miniature camera sensor is used directly within the illumination beam. Measurements taken using our approach are solely concerned with the illumination optics as the detection optics are not involved. We present a miniature beam profiling device and high dynamic range flux reconstruction algorithm that together are capable of accurately reproducing quantitative 3D flux maps over a large focal volume. Performance of this beam profiling system is verified within an optical test bench and demonstrated for fluorescence microscopy by profiling the low NA illumination beam of a single plane illumination microscope. The generality and success of this approach showcases a widely flexible beam amplitude diagnostic tool for use within the life sciences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray Fluorescence Microscopy to Develop Elemental Classifiers and Investigate Elemental Signatures in BALB/c Mouse Intestine a Week after Exposure to 8 Gy of Gamma Rays

Iron redistribution in the intestine after total body irradiation is an established phenomenon. However, in the literature, there are no reports about the use of X-ray fluorescence microscopy or equivalent techniques to generate semi-quantitative 2D maps of iron in sectioned intestine samples from irradiated mice. In this work, we used X-ray fluorescence microscopy (XFM) to map the elemental content of iron as well as phosphorus, sulfur, calcium, copper and zinc in tissue sections of the small intestine from eight-week-old BALB/c male mice that developed gastrointestinal acute radiation syndrome (GI-ARS) in response to exposure to 8 Gray of gamma rays. Seven days after irradiation, we found that the majority of the iron is localized as hot spots in the intercellular regions of the area surrounding crypts and stretching between the outer perimeter of the intestine and the surface cell layer of villi. In addition, this study represents our current efforts to develop elemental cell classifiers that could be used for the automated generation of regions of interest for analyses of X-ray fluorescence maps. Once developed, such a tool will be instrumental for studies of effects of radiation and other toxicants on the elemental content in cells and tissues. While XFM studies cannot be conducted on living organisms, it is possible to envision future scenarios where XFM imaging of single cells sloughed from the human (or rodent) intestine could be used to follow up on the progression of GI-ARS.

X-ray fluorescence microscopy↗

The X-ray Fluorescence Microscopy Beamline at the Australian Synchrotron

A hard x-ray micro-nanoprobe has commenced operation at the Australian Synchrotron providing versatile x-ray fluorescence microscopy across an incident energy range from 4 to 25 keV. Two x-ray probes are used to collect {mu}-XRF and {mu}-XANES for elemental and chemical microanalysis: a Kirkpatrick-Baez mirror microprobe for micron resolution studies and a Fresnel zone plate nanoprobe capable of 60-nm resolution. Some unique aspects of the beamline design and operation are discussed. An advanced energy dispersive x-ray fluorescence detection scheme named Maia has been developed for the beamline, which enables ultrafast x-ray fluorescence microscopy.

36 MATERIALS SCIENCE↗

Analysis of Environmental Swipes Using Fluorescence Microscopy - Summary Report

This report summarizes efforts as part of a collaboration between Oak Ridge National Laboratory (ORNL) and the University of Kansas (KU) during fiscal year 2016 for the purpose of screening environmental swipes (ESs) using fluorescence microscopy. The overall goal of this work is to image actinide-bearing species by exploiting the fluorescence properties of the uranyl moiety. If successfully developed, this capability would permit automated screening of actinide species in environmental swipes to prioritize samples for destructive analysis. The evaluation of efforts to date has shown that uranyl fluoride can be imaged using fluorescence microscopy and the vibronic structure can be resolved; however, difficulties arise when attempting to image these materials on ESs because of spectral interference. Due to the fluorescence decay differences between cellulosic fibers and uranyl-containing materials, time-gating approaches were investigated to minimize this interference. This approach shows promise; however, the technique requires additional developmental work before it can be transitioned to a robust method for laboratory use.

54 ENVIRONMENTAL SCIENCES↗

Solid-immersion fluorescence microscopy with increased emission and super resolution

We investigate solid-immersion fluorescence microscopy suitable for super-resolution nanotechnology and biological imaging, and have observed limit of resolution as small as 15 nm with microspheres, mitochondria, and chromatin fibers. We have further observed that fluorescence efficiency increases with excitation power density, implicating appreciable stimulated emission and increased resolution. We discuss potential advantages of the solid-immersion microscopy, including combined use with previously established super-resolution techniques for reaching deeper beyond the conventional diffraction limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Examining Thermally Sprayed Coats By Fluorescence Microscopy

True flaws distinquished from those induced by preparation of specimens. Fluorescence microscopy reveals debonding, porosity, cracks, and other flaws in specimens of thermally sprayed coating materials. Specimen illuminated, and dye it contains fluoresces, emitting light at different wavelength. Filters emphasize contrast between excitation light and emission light. Specimen viewed directly or photographed on color film.

Street, Kenneth W., Jr.↗

X-Ray Fluorescence Microscopy: A Method of Measuring Ion Concentrations in the Ear

This technical note describes synchrotron x-ray fluorescence microscopy (XFM) as a method for measuring the concentrations of various elements in cross-sections of the ear at extremely high resolution. This method could be of great importance for addressing many open questions in hearing research. XFM uses synchrotron radiation to evoke emissions from many biologically relevant elements in the tissue. The intensity and wavelength of the emitted radiation provide a fingerprint of the tissue composition that can be used to measure the concentration of the elements in the sampled location. Here, we focus on energies that target biologically-relevant elements of the periodic table between magnesium and zinc. Since a highly focused x-ray beam is used, the spot size is well below 1 mu m and the samples can be scanned at a nanometer lateral resolution. This study shows that measurement of the concentrations of different elements is possible in a mid-modiolar cross-section of a mouse cochlea. Images are presented that indicate potassium and chloride "hot spots" in the spiral ligament and the spiral limbus, providing experimental evidence for the potassium recycling pathway and showing the cochlear structures involved. Scans of a section obtained from the incus, one of the middle ear ossicles, in a developing mouse have shown that zinc is not uniformly distributed This supports the hypothesis that zinc plays a special role in the process of ossification. Although limited by sophisticated sample preparation and sectioning, the method provides ample exciting opportunities, to understand the role of genetics and epigenetics on hearing mechanisms in ontogeny and phylogeny.

59 BASIC BIOLOGICAL SCIENCES↗

Adaptive Optical Two-Photon Fluorescence Microscopy Probes Cellular Organization of Ocular Lenses In Vivo

The mammalian ocular lens is an avascular multicellular organ that grows continuously throughout life. Traditionally, its cellular organization is investigated using dissected lenses, which eliminates in vivo environmental and structural support. Therefore, in vivo optical imaging methods for studying lenses in their native context in live animals are urgently needed. Here, we demonstrated that two-photon fluorescence microscopy can visualize lens cells in vivo. To maintain subcellular resolution at depth, we used adaptive optics to correct aberrations owing to ocular and lens tissues, which led to substantial signal and resolution improvements. Imaging lens cells up to 980 µm deep, we observed novel cellular organizations including suture-associated voids, enlarged vacuoles, and large cavities, contrary to the conventional view of a highly ordered organization. We tracked these features longitudinally over weeks and observed the incorporation of new cells during growth. Taken together, noninvasive longitudinal in vivo imaging of lens morphology using adaptive optics two-photon fluorescence microscopy will allow us to observe the development or alterations of lens cellular organization in living animals directly.

60 APPLIED LIFE SCIENCES↗

Forecasting Battery Electrode Performance via Electrochemical Fluorescence Microscopy and Machine-Learning

Predicting lithium-ion battery performance is hindered by microscale electrode heterogeneities invisible to conventional diagnostics. Here, we combine electrochemical fluorescence microscopy (EFM), which maps electronic connectivity by visualizing an electrofluorophore reaction distribution, with a multitask ElasticNet regression to forecast discharge capacity from spatial heterogeneity. Analyzing 196 images from six pilot-scale LiNi 0.5 Mn 0.3 Co 0.2 O 2 cathodes with varying carbon loadings, we extract 62 descriptors that capture morphology and texture. A compact five-feature model predicts capacity across eight discharge rates, achieving a per-target R 2 of up to 0.63 and an overall R 2 of 0.92, with a mean absolute percentage error of less than 2%. This performance rivals impedance-based approaches while avoiding their reliance on postformation data and incomplete electronic network information. Our facile and rapid, image-driven method may enable electrode quality control upstream of costly cell assembly to offer a transformative tool for data-driven battery research and manufacturing.

battery electrodes↗

System and method for controlling depth of imaging in tissues using fluorescence microscopy under ultraviolet excitation following staining with fluorescing agents

The present disclosure relates to a method for analyzing tissue specimens. In one implementation the method involves obtaining a tissue sample and exposing the sample to one or more fluorophores as contrast agents to enhance contrast of subcellular compartments of the tissue sample. The tissue sample is illuminated by an ultraviolet (UV) light having a wavelength between about 200 nm to about 400 nm, with the wavelength being selected to result in penetration to only a specified depth below a surface of the tissue sample. Inter-image operations between images acquired under different imaging parameters allow for improvement of the image quality via removal of unwanted image components. A microscope may be used to image the tissue sample and provide the image to an image acquisition system that makes use of a camera. The image acquisition system may create a corresponding image that is transmitted to a display system for processing and display.

36 MATERIALS SCIENCE↗

System and method for controlling depth of imaging in tissues using fluorescence microscopy under ultraviolet excitation following staining with fluorescing agents

A method is disclosed for analyzing a thin tissue sample and adapted to be supported on a slide. The tissue sample may be placed on a slide and exposed to one or more different exogenous fluorophores excitable in a range of about 300 nm-200 nm, and having a useful emission band from about 350 nm-900 nm, and including one or more fluorescent dyes or fluorescently labeled molecular probes that accumulate in tissue or cellular components. The fluorophores may be excited with a first wavelength of UV light between about 200 nm-290 nm. An optical system collects emissions from the fluorophores at a second wavelength, different from the first wavelength, which are generated in response to the first wavelength of UV light, to produce an image for analysis.

47 OTHER INSTRUMENTATION↗

Synchrotron-based X-ray Fluorescence Microscopy as a Technique for Imaging of Elements in Plants

Understanding the distribution of elements within plant tissues is important across a range of fields in plant science. In this review, we examine synchrotron-based X-ray fluorescence microscopy (XFM) as an elemental imaging technique in plant sciences, considering both its historical and current uses as well as discussing emerging approaches. XFM offers several unique capabilities of interest to plant scientists, including in vivo analyses at room temperature and pressure, good detection limits (ca. 1-100 mg/kg), and excellent resolution (down to 50 nm). This has permitted its use in a range of studies, including for functional characterization in molecular biology, examining the distribution of nutrients in food products, understanding movement of foliar fertilizers, investigating the behaviour of engineered nanoparticles, elucidating the toxic effects of metal(loid)s in agronomic plant species, and studying the unique properties of hyperaccumulating plants. We anticipate that continuing technological advances at XFM beamlines will also provide new opportunities moving into the future, such as for high-throughput screening in molecular biology, use of exotic metal tags for protein localization, and for enabling time-resolved, in vivo analyses of living plants. By examining current and potential future applications, we hope to encourage further XFM studies in plant sciences by highlighting the versatility of this approach.

47 OTHER INSTRUMENTATION↗

Synchrotron-based X-ray Fluorescence Microscopy in Conjunction with Nanoindentation to Study Molecular-Scale Interactions of Phenol-Formaldehyde in Wood Cell Walls

Understanding and controlling molecular-scale interactions between adhesives and wood polymers are critical to accelerate the development of improved adhesives for advanced wood-based materials. The submicrometer resolution of synchrotron-based X-ray fluorescence microscopy (XFM) was found capable of mapping and quantifying infiltration of Br-labeled phenolformaldehyde (BrPF) into wood cell walls. Cell wall infiltration of five BrPF adhesives with different average molecular weights (MWs) was mapped. Nanoindentation on the same cell walls was performed to assess the effects of BrPF infiltration on cell wall hygromechanical properties. For the same amount of weight uptake, lower MW BrPF adhesives were found to be more effective at decreasing moisture-induced mechanical softening. This greater effectiveness of lower MW phenolic adhesives likely resulted from their ability to more intimately associate with water sorption sites in the wood polymers. Evidence also suggests that a BrPF interpenetrating polymer network (IPN) formed within the wood polymers, which might also decrease moisture sorption by mechanically restraining wood polymers during swelling.

adhesive↗

Synchrotron-based X-ray fluorescence microscopy enables multiscale spatial visualization of ions involved in fungal lignocellulose deconstruction

Ions play an important role in the growth and development of filamentous fungi, particularly in the fungal decay process of lignocellulose materials. The role of ions in wood degradation, and more broadly fungal metabolism, have implications for diverse research disciplines ranging from plant pathology and forest ecology, to wood protection. Despite the importance of ions in both enzymatic and non-enzymatic fungal decay mechanisms, the spatial distribution of ions in wood and fungal hyphae during decay is not known. Here we employ synchrotron based X-ray fluorescence microscopy (XFM) to map physiologically relevant ions, such as K, Ca, Mn, Fe, and Zn, in wood being decayed by the model brown rot fungus Serpula lacrymans . Two-dimensional XFM maps were obtained to study the ion spatial distributions from mm to submicron length scales in wood and hyphae. Three-dimensional ion volume reconstructions with submicron spatial resolution were also acquired of wood cell walls and fungal hyphae, and an estimation of oxalate concentration at the microscale was made. Results show that the fungus actively transports some ions, such as Fe, into the wood and controls the distribution of ions at both the bulk wood and cellular length scales. Within the fungal hyphae, ion volume reconstructions show inhomogeneous ion distributions at the micron length scale and this localization may be indicative of both physiological status and requirements or in some cases, potentially sites associated with the initiation of metal-catalyzed wood degradation. Finally, these measurements illustrate how synchrotron based XFM is uniquely qualified for probing the role of ions in the growth and metabolic processes of filamentous fungi.

59 BASIC BIOLOGICAL SCIENCES↗

Use of X-Ray Fluorescence Microscopy for Studies on Research Models of Hepatocellular Carcinoma

Introduction: TheraSphere ® microspheres containing yttrium 90 Y are among many radioembolization agents used clinically to reduce liver tumor burden, and their effects on cancer volume reduction are well-established. At the same time, concerns about off target tissue injury often limit their use. Deeper investigation into tissue distribution and long-term impact of these microspheres could inform us about additional ways to use them in practice. Methods: Healthy rat liver and rabbit liver tumor samples from animals treated with TheraSpheres were sectioned and their elemental maps were generated by X-ray fluorescence microscopy (XFM) at the Advanced Photon Source (APS) synchrotron at Argonne National Laboratory (ANL). Results: Elemental imaging allowed us to identify the presence and distribution of TheraSpheres in animal tissues without the need for additional sample manipulation or staining. Ionizing radiation produced by 90 Y radioactive contaminants present in these microspheres makes processing TheraSphere treated samples complex. Accumulation of microspheres in macrophages was observed. Conclusions: This is the first study that used XFM to evaluate the location of microspheres and radionuclides in animal liver and tumor samples introduced through radioembolization. XFM has shown promise in expanding our understanding of radioembolization and could be used for investigation of human patient samples in the future.

60 APPLIED LIFE SCIENCES↗

IV Administered Gadodiamide Enters the Lumen of the Prostatic Glands: X-Ray Fluorescence Microscopy Examination of a Mouse Model

In our objective, we descibe how dynamic contrast-enhanced MRI (DCE-MRI) has become a standard component of multiparametric protocols for MRI examination of the prostate, and its use is incorporated into current guidelines for prostate MRI examination. Analysis of DCE-MRI data for the prostate is usually based on the distribution of gadolinium-based agents, such as gadodiamide, into two well-mixed compartments, and it assumes that gadodiamide does not enter into the glandular lumen. However, this assumption has not been directly tested. The purpose of this study was to use x-ray fluorescence microscopy (XFM) imaging in situ to measure the concentration of gadodiamide in the epithelia and lumens of the prostate of healthy mice after IV injection of the contrast agent. For our materials and methods, six C57Bl6 male mice (age, 28 weeks) were sacrificed 10 minutes after IV injection of gadodiamide (0.13 mmol/kg), and three mice were sacrificed after saline injection. Prostate tissue samples obtained from each mouse were harvested and frozen; 7-μm-thick slices were sectioned for XFM imaging, and adjacent 5-μm-thick slices were sectioned for H and E staining. Elemental concentrations were determined from XFM images. Our results show mean (± SD) baseline concentration of gadolinium of 0.01 ± 0.01 mM was determined from XFM measurements of prostatic tissue samples when no gadodiamide was administered, and it was used to determine the measurement error. When gadodiamide was added, the mean concentrations of gadolinium in the epithelia and lumens in 32 prostatic glands from six mice were 1.00 ± 0.13 and 0.36 ± 0.09 mM, respectively. In conclusion, our data suggest that IV administration of gadodiamide results in uptake of contrast agent by the glandular lumens of the mouse prostate. We were able to quantitatively determine gadodiamide distributions in mouse prostatic epithelia and lumens.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast-scanning high-flux microprobe for biological X-ray fluorescence microscopy and microXAS

There is a growing interest in the biomedical community in obtaining information concerning the distribution and local chemical environment of metals in tissues and cells. Recently, biological X-ray fluorescence microscopy (XFM) has emerged as the tool of choice to address these questions. A fast-scanning high-flux X-ray microprobe, built around a recently commissioned pair of 200 mm-long Rh-coated silicon Kirkpatrick-Baez mirrors, has been constructed at BioCAT beamline 18ID at the Advanced Photon Source. The new optical system delivers a flux of 1.3 x 10{sup 12} photons s{sup -1} into a minimum focal spot size of {approx}3-5 {micro}m FWHM. A set of Si drift detectors and bent Laue crystal analyzers may be used in combination with standard ionization chambers for X-ray fluorescence measurements. BioCAT's scanning software allows fast continuous scans to be performed while acquiring and storing full multichannel analyzer spectra per pixel on-the-fly with minimal overhead time (<20 ms per pixel). Together, the high-flux X-ray microbeam and the rapid-scanning capabilities of the BioCAT beamline allow the collection of XFM and micro X-ray absorption spectroscopy (microXAS) measurements from as many as 48 tissue sections per day. This paper reports the commissioning results of the new instrument with representative XFM and microXAS results from tissue samples.

43 PARTICLE ACCELERATORS↗