Search NASA⌕ Search

SEARCH · Search NASA

Results for “Minimum Detectable Activity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

DASEventNet: AI‐Based Microseismic Detection on Distributed Acoustic Sensing Data From the Utah FORGE Well 16A (78)‐32 Hydraulic Stimulation

Abstract Distributed acoustic sensing (DAS) has emerged as a promising seismic technology for monitoring microearthquakes (MEQs) with high spatial resolution. Efficient algorithms are needed for processing large DAS data volumes. This study introduces a deep learning (DL) model based on a Residual Convolutional Neural Network (ResNet) for detecting MEQs using DAS data, named as DASEventNet. The test data were collected from the Utah FORGE 16A (78)‐32 hydraulic stimulation experiments conducted in April 2022. The DASEventNet model achieves a remarkable accuracy of 100% when discriminating MEQs from noise in the raw test set of 260 examples. Surprisingly, the model identified weak MEQ signatures that have been manually categorized as noise. The decision‐making process with the model is decoded by the classic activation map, which illuminates learning features of the DASEventNet model. These features provide clear illustrations of weak MEQs and varied noise types. Finally, we apply the trained model to the entire period (∼7 days) of continuous DAS recordings and find that it discovers >5,700 new MEQs, previously unregistered in the public Silixa DAS catalog. The DASEventNet model significantly outperforms the traditional seismic method Short‐Term Average/Long‐Term Average (STA/LTA), which detected only 1,307 MEQs. The DASEventNet detection threshold is M w −1.80 compared to the minimum magnitude of M w −1.14 detected by STA/LTA. The spatiotemporal distribution of the newly identified MEQs defines an extensive stimulation zone and more accurately characterizes fracture geometry. Our results highlight the potential of DL for long‐term, real‐time microseismic monitoring that can improve enhanced geothermal systems and other activities that include subsurface hydraulic fracturing.

15 GEOTHERMAL ENERGY↗

Diffused trenches for high fill-factor Low-Gain Avalanche Diodes

Low-Gain Avalanche Diodes (LGADs) are a class of silicon detectors that have been specifically designed for the fast detection of minimum ionizing particles (mips) in High-Energy Physics experiments. While they provide timing resolution on the order of a few tens of picoseconds, they cannot achieve high spatial resolution due to the intrinsic characteristics of their structures. Thus, active R&D is on-going to develop detectors based on LGADs to improve their spatial resolution while maintaining the timing performance of the LGADs. Such devices are, for example, AC-coupled LGADs and Deep-Junction LGADs. Another device option is the Trench-Isolated LGAD (TI LGAD), where trenches etched at the periphery of the pixels isolate them while providing a high fill-factor. Here, in this paper, we present a variation of this latter approach, demonstrating its feasibility by means of 2-dimensional TCAD simulations.

47 OTHER INSTRUMENTATION↗

In Vitro Antimicrobial Activity of Volatile Compounds from the Lichen Pseudevernia furfuracea (L.) Zopf. Against Multidrug-Resistant Bacteria and Fish Pathogens

Lichens are symbiotic organisms with unique secondary metabolism. Various metabolites from lichens have shown antimicrobial activity. Nevertheless, very few studies have investigated the antimicrobial potential of the volatile compounds they produce. This study investigates the chemical composition and antimicrobial properties of volatile compounds from Pseudevernia furfuracea collected in two regions of Morocco. Hydrodistillation was used to obtain volatile compounds from samples collected in the High Atlas and Middle Atlas. Gas chromatography–mass spectrometry (GC-MS) analysis identified phenolic cyclic compounds as the primary constituents, with atraric acid and chloroatranol being the most abundant. Additionally, eight compounds were detected in lichens for the first time. The antimicrobial activity of these compounds was assessed using disc diffusion and broth microdilution methods. Both samples demonstrated significant antimicrobial effects against multidrug-resistant human bacteria, reference microorganisms, fish pathogens, and Candida albicans, with minimum inhibitory concentrations (MICs) ranging from 1000 µg/mL to 31.25 µg/mL. This study provides the first report on the volatile compounds from Pseudevernia furfuracea and their antimicrobial effects, particularly against fish pathogens, suggesting their potential as novel antimicrobial agents for human and veterinary use. Further research is warranted to explore these findings in more detail.

Essadki, Yasser (ORCID:0009000648460075)↗

The Outburst of the Young Star Gaia19bey

We report photometry and spectroscopy of the outburst of the young stellar object Gaia19bey. We have established the outburst light curve with archival Gaia “G,” ATLAS “Orange,” Zwicky Transient Facility r-band, and Pan-STARRS “rizy”-filter photometry, showing an outburst of ~4 yr duration, longer than typical EX Lupi objects but shorter than FU Orionis objects. Its pre-outburst spectral energy distribution shows a flat far-infrared spectrum, confirming the early evolutionary state of Gaia19bey and its similarity to other deeply embedded young stars experiencing outbursts. A lower limit to the peak outburst luminosity is ~182 L{sub ⊙} at an assumed distance of 1.4 kpc, the minimum plausible distance. Infrared and optical spectroscopy near maximum light show an emission line spectrum, including H i lines, strong red Ca ii emission, other metal emission lines, infrared CO bandhead emission, and a strong infrared continuum. Toward the end of the outburst, the emission lines have all but disappeared and the spectrum has changed into an almost pure continuum spectrum. This indicates a cessation of magnetospheric accretion activity. The near-infrared colors have become redder as Gaia19bey has faded, indicating a cooling of the continuum component. Near the end of the outburst, the only remaining strong emission lines are forbidden shock-excited emission lines. Adaptive optics integral-field spectroscopy shows the H{sub 2} 1–0 S(1) emission with the morphology of an outflow cavity and the extended emission in the [Fe ii] line at 1644 nm with the morphology of an edge-on disk. However, we do not detect any large-scale jet from Gaia19bey.

79 ASTRONOMY AND ASTROPHYSICS↗

Detectability of standing accretion shock instabilities activity in supernova neutrino signals

We introduce a novel methodology for establishing the presence of standing accretion shock instabilities (SASI) in the dynamics of a core collapse supernova from the observed neutrino event rate at water- or ice- based neutrino detectors. The methodology uses a likelihood ratio in the frequency domain as a test- statistics; it is also employed to assess the potential to estimate the frequency and the amplitude of the SASI modulations of the neutrino signal. The parameter estimation errors are consistent with the minimum possible errors as evaluated from the inverse of the Fisher information matrix, and close to the theoretical minimum for the SASI amplitude. Using results from a core-collapse simulation of a 15 solar-mass star by Kuroda et al. [Astrophys. J. 851, 62 (2017).] as a test bed for the method, we find that SASI can be identified with high confidence for a distance to the supernova of up to ~6 kpc for IceCube and up to ~3 kpc for a 0.4 Mt mass water Cherenkov detector. This methodology will aid the investigation of a future galactic supernova.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance evaluation of neutron noise analysis in detecting special nuclear materials

Reliable and rapid inspection techniques play a vital role in preventing illicit trafficking of special nuclear materials. Active interrogation systems using neutrons produced by portable, high-flux deuterium-deuterium or deuterium-tritium neutron generators are being actively developed as a secondary scanning tool for this purpose. In this study, a neutron noise analysis-based approach for detecting unshielded and shielded special nuclear materials by using a pulsed deuterium-tritium neutron generator was evaluated. Here, this approach analyzes the fluctuation of neutron counts. Its performance was quantified with regard to time-to-detection to achieve a minimum probability of detection of 99% and a probability of false alarm of less than 1% considering various amounts of special nuclear materials and different shielding configurations. It was demonstrated that this approach could detect 17 uranium slugs in 5 s given a neutron generator yield of 8.1 × 10 7 n/s. These slugs could be detected within a reasonable time frame (200 s) when they were shielded by 10.16 cm of high-density polyethylene. The results obtained using the neutron noise analysis approach were compared with those obtained using the commonly used differential die-away analysis technique, a sensitive technique for detecting the presence of fissile materials by utilizing the prompt fission neutrons produced when the source neutrons from a neutron generator are completely diminished. For example, the time to detect 2 unshielded uranium slugs was 2.1 s when using the differential die-away analysis technique; it increased to 93 s for the neutron noise analysis approach. Although the noise analysis-based approach exhibits an overall performance which is not as good as that of differential die-away, neutron noise provides an alternative method for effective detection of special nuclear materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A call to standardize metrics for monitoring baleen whales near marine construction activities

Effective monitoring is necessary to protect marine mammal species during the construction of offshore infrastructure. The tools for detecting or monitoring marine mammals span traditional (e.g., visual observers, optical cameras), to newer (e.g., passive acoustic monitoring, infrared cameras, tags), and emerging (e.g., satellite imagery, environmental DNA, dimethyl sulfide concentration) technologies. Some are better suited for use during offshore development; however, peer-reviewed literature does not typically evaluate and report on the performance of these various technologies. We define a minimum set of metrics related to efficacy (i.e., confusion matrix, precision and recall, probability of missed mitigation), detection range (i.e., maximum and reliable detection range, spatial resolution), and data delivery (i.e., detection latency, system reliability, temporal resolution) that we recommend are needed to assess the utility of monitoring technologies for this purpose. Following a literature review of relevant studies, we highlight which publications reported these metrics and used multiple technologies to compare relative performance. We also emphasize the benefits of multi-modal approaches and recommend performance assessments through modeling or large-scale collaborative field testing. These metrics will standardize data collection, reporting, and analysis; promote consistent and comparable results; and foster collaboration among developers, regulatory agencies, and scientists. This may lead to the co-development of technology that achieves multiple goals, has greater application, and can answer research questions while collecting data to fulfill permitting requirements. These metrics may also inform decisions on what systems regulatory agencies might consider using and reduce monitoring costs, which is critical to support the marine sector's rapid growth alongside marine mammal conservation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Third international challenge to model the medium- to long-range transport of radioxenon to four Comprehensive Nuclear-Test-Ban Treaty monitoring stations

In 2015 and 2016, atmospheric transport modeling challenges were conducted in the context of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) verification, however, with a more limited scope with respect to emission inventories, simulation period and number of relevant samples (i.e., those above the Minimum Detectable Concentration (MDC)) involved. Therefore, a more comprehensive atmospheric transport modeling challenge was organized in 2019. Stack release data of Xe-133 were provided by the Institut National des Radioéléments/IRE (Belgium) and the Canadian Nuclear Laboratories/CNL (Canada) and accounted for in the simulations over a three (mandatory) or six (optional) months period. Best estimate emissions of additional facilities (radiopharmaceutical production and nuclear research facilities, commercial reactors or relevant research reactors) of the Northern Hemisphere were included as well. Model results were compared with observed atmospheric activity concentrations at four International Monitoring System (IMS) stations located in Europe and North America with overall considerable influence of IRE and/or CNL emissions for evaluation of the participants’ runs. Participants were prompted to work with controlled and harmonized model set-ups to make runs more comparable, but also to increase diversity. It was found that using the stack emissions of IRE and CNL with daily resolution does not lead to better results than disaggregating annual emissions of these two facilities taken from the literature if an overall score for all stations covering all valid observed samples is considered. A moderate benefit of roughly 10% is visible in statistical scores for samples influenced by IRE and/or CNL to at least 50% and there can be considerable benefit for individual samples. Effects of transport errors, not properly characterized remaining emitters and long IMS sampling times (12–24 h) undoubtedly are in contrast to and reduce the benefit of high-quality IRE and CNL stack data. Complementary best estimates for remaining emitters push the scores up by 18% compared to just considering IRE and CNL emissions alone. Despite the efforts undertaken the full multi-model ensemble built is highly redundant. An ensemble based on a few arbitrary runs is sufficient to model the Xe-133 background at the stations investigated. The effective ensemble size is below five. An optimized ensemble at each station has on average slightly higher skill compared to the full ensemble. However, the improvement (maximum of 20% and minimum of 3% in RMSE) in skill is likely being too small for being exploited for an independent period.

54 ENVIRONMENTAL SCIENCES↗

Optical 14 C Tracing for Biological and Pharmaceutical Applications Using Two-Color Cavity Ringdown Spectroscopy

Laser-based 14 C quantitation has been proposed as a more affordable, higher-throughput, table-top alternative to accelerator mass spectrometry (AMS). Here, we demonstrate the feasibility of a mid-IR 14 C detector based on two-color cavity ringdown spectroscopy (2C-CRDS) for low-level 14 C isotope tracing in biological studies. The 2C-CRDS technique quantifies the sample 14 C content by measuring the 14 CO 2 absorption signals from the combusted samples with mid-IR lasers. With 2C-CRDS, we previously demonstrated the most sensitive and accurate optical measurements of 14 CO 2 . The current detection sensitivity and quantitation accuracy of the instrument, at a few parts per quadrillion (where a quadrillion = 10 15 ) 14 C/C mole fraction, is competitive against AMS. Here, by applying the 2C-CRDS 14 C sensor to two applications relevant to 14 C-labeled biochemical analysis and pharmaceutical studies, we demonstrate sub-fCi level (where 1 fCi = 10 –15 Ci) quantitation of sample 14 C activity, with a minimum sample-size requirement of 3 mg of carbon. The current measurement throughput, ~25 min/sample, is largely limited by the sampling efficiency of the online combustion and CO 2 processing interface to the 2C-CRDS instrument. The possibility of a significantly improved measurement throughput of a few minutes per sample is suggested by the results of a flow-through 14 CO 2 sampling scheme. In conclusion, this improved measurement efficiency, combined with the relatively low cost and compact size of a 2C-CRDS sensor, could potentially revolutionize high-sensitivity 14 C tracing in biological, pharmaceutical, and clinical studies.

60 APPLIED LIFE SCIENCES↗

Development and testing of a continuous maritime monitor for radionuclide aerosols

Monitoring airborne concentrations of radionuclide activity may provide a timely warning to sea-based assets to avoid contamination from a radioactive plume. The development and testing of an automated aerosol monitoring system that can capture and detect radioactive particulate from marine air is presented. A custom electrostatic precipitator (ESP) was designed to capture particulate onto a reusable collection media. The collection efficiency of the ESP system for radon progeny was determined to be ~23%. A conservative calculation of the minimum detectable concentration of 214 Bi was estimated as 0.3-8 Bq/m 3 . The system was demonstrated in continuous operation, without consumables and limited maintenance, in a marine environment at the PNNL campus in Sequim, Washington. In conclusion, a successful 2-month deployment indicates the feasibility of the approach for continuous maritime monitoring for radionuclide aerosols.

Moore, Michael E. [Pacific Northwest National Labo↗

Multiple giant eruptions and X-ray emission in the recoiling AGN/LBV candidate SDSS1133

We present a comprehensive analysis of 20 yr worth of multicolour photometric light curves, multiepoch optical spectra, and X-ray data of an off-nuclear variable object SDSS1133 in Mrk 177 at z = 0.0079. The UV-optical light curves reveal that SDSS1133 experienced four outbursts in 2001, 2014, 2019, and 2021. The persistent UV-optical luminosity in the non-outbursting state is ~1041 erg s -1 with small-scale flux variations, and peak luminosities during the outbursts reach ~10 42 erg s -1 . The optical spectra exhibit enduring broad hydrogen Balmer P-Cygni profiles with the absorption minimum at ~-2000 km s -1 , indicating the presence of fast-moving ejecta. Chandra detected weak X-ray emission at a 0.3-10-keV luminosity of L X = 4 × 10 38 erg s -1 after the 2019 outburst. These lines of evidence suggests that SDSS1133 is an extreme luminous blue variable (LBV) star experiencing multiple giant eruptions with interactions of the ejected shell with different shells and/or circumstellar medium (CSM), and disfavours the recoiling active galactic nuclei scenario suggested in the literature. We suggest that pulsational pair-instability may provide a viable explanation for the multiple energetic eruptions in SDSS1133. If the current activity of SDSS1133 is a precursor of a supernova explosion, we may be able to observe a few additional giant eruptions and then the terminal supernova explosion or collapse to a massive black hole in future observations.

79 ASTRONOMY AND ASTROPHYSICS↗

The influence of environmental microseismicity on detection and interpretation of small-magnitude events in a polar glacier setting

Glacial environments exhibit temporally variable microseismicity. To investigate how microseismicity influences event detection, we implement two noise-adaptive digital power detectors to process seismic data from Taylor Glacier, Antarctica. We add scaled icequake waveforms to the original data stream, run detectors on the hybrid data stream to estimate reliable detection magnitudes and compare analytical magnitudes predicted from an ice crack source model. We find that detection capability is influenced by environmental microseismicity for seismic events with source size comparable to thermal penetration depths. When event counts and minimum detectable event sizes change in the same direction (i.e. increase in event counts and minimum detectable event size), we interpret measured seismicity changes as ‘true’ seismicity changes rather than as changes in detection. Generally, one detector (two degree of freedom (2dof)) outperforms the other: it identifies more events, a more prominent summertime diurnal signal and maintains a higher detection capability. We conclude that real physical processes are responsible for the summertime diurnal inter-detector difference. One detector (3dof) identifies this process as environmental microseismicity; the other detector (2dof) identifies it as elevated waveform activity. Our analysis provides an example for minimizing detection biases and estimating source sizes when interpreting temporal seismicity patterns to better infer glacial seismogenic processes.

54 ENVIRONMENTAL SCIENCES↗

Overview of physics results from the ADITYA-U tokamak and future experiments

The ADITYA upgrade (ADITYA-U), a medium-sized (R 0 = 75 cm, a = 25 cm) conventional tokamak facility in India, has been consistently producing experiments findings by usingcircular and shaped-plasmas. Recognizing the plasma parameters aligning closely with the design parameters of circular limited plasmas, ADITYA-U shifted its focus toward exploring the operational regime for experimentation on saw-tooth and MHD phenomena. Moreover, ADITYA-U has made consistent advancements toward conducting preliminary plasma shaping experiments through the activation of top and bottom divertor coils utilizing hydrogen as well as deuterium fuels. Confinement is improved by a factor of ~1.5 in D 2 plasmas when compared to H 2 plasmas of ADITYA-U. Further, ADITYA-U operations emphasize preventing disruptions and runaway electrons (REs) to ensure safe operations for future fusion devices. Significant suppression of REs has been achieved in ADITYA-U with the application of pulsed localized vertical magnetic field (LVF) perturbation, thereby establishing the technique's independence from the tokamak device. The successful RE mitigation requires a critical threshold of LVF pulse magnitude, which is approximately 1% of the toroidal magnetic field, and a minimum duration of ~5 ms. Apart from this, several novel findings have been achieved in the ADITYA-U experiments, including the modification of sawtooth duration through gas-puff, the emergence of MHD-induced geodesic acoustic mode-like oscillations, the propagation of fast heat pulses induced by MHD activity, the control of RE dynamics through Gas-puffs, the propagation of pinch-driven cold-pulses, the transport and core accumulations of argon impurities, the mass dependency of plasma toroidal rotation and the detection of 'RICE' scaling, as well as the characterization of edge plasma using wall conditioning methods, such as glow discharge cleaning using a combination of Ar-H 2 mixture, localized wall cleaning by electron cyclotron resonant plasma, and the development of machine learning-based disruption predictions, will be discussed in this paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Potential Activities and Long Lifetimes of Organic Carbon-Degrading Extracellular Enzymes in Deep Subsurface Sediments of the Baltic Sea

Heterotrophic microorganisms in marine sediments produce extracellular enzymes to hydrolyze organic macromolecules, so their products can be transported inside the cell and used for energy and growth. Therefore, extracellular enzymes may mediate the fate of organic carbon in sediments. The Baltic Sea Basin is a primarily depositional environment with high potential for organic matter preservation. The potential activities of multiple organic carbon-degrading enzymes were measured in samples obtained by the International Ocean Discovery Program Expedition 347 from the Little Belt Strait, Denmark, core M0059C. Potential maximum hydrolysis rates (V max ) were measured at depths down to 77.9mbsf for the following enzymes: alkaline phosphatase, β- d -xylosidase, β- d -cellobiohydrolase, N-acetyl-β- d -glucosaminidase, β-glucosidase, α-glucosidase, leucyl aminopeptidase, arginyl aminopeptidase, prolyl aminopeptidase, gingipain, and clostripain. Extracellular peptidase activities were detectable at depths shallower than 54.95mbsf, and alkaline phosphatase activity was detectable throughout the core, albeit against a relatively high activity in autoclaved sediments. β-glucosidase activities were detected above 30mbsf; however, activities of other glycosyl hydrolases (β-xylosidase, β-cellobiohydrolase, N-acetyl-β-glucosaminidase, and α-glucosidase) were generally indistinguishable from zero at all depths. These extracellular enzymes appear to be extremely stable: Among all enzymes, a median of 51.3% of enzyme activity was retained after autoclaving for an hour. We show that enzyme turnover times scale with the inverse of community metabolic rates, such that enzyme lifetimes in subsurface sediments, in which metabolic rates are very slow, are likely to be extraordinarily long. A back-of-the-envelope calculation suggests enzyme lifetimes are, at minimum, on the order of 230days, and may be substantially longer. These results lend empirical support to the hypothesis that a population of subsurface microbes persist by using extracellular enzymes to slowly metabolize old, highly degraded organic carbon.

54 ENVIRONMENTAL SCIENCES↗

Survey of Technologies to Meet PAG limits for Detection of Cesium-137 in Water

The goal of this report is to evaluate the process of adding a sorbent to the sampling process to preconcentrate Cs-137 and then analyze the sorbent to provide a rapid assessment of results to guide decisions on drinking water sources and the protection of the public. Multiple unit design variables were considered: sample configuration/geometry, sorbent efficiency, sample volume. Model simulations demonstrated through these unit design efficiencies that 10 L of sample volume processed through a sorbent provides nearly two orders of magnitude improvement in sample counting time to provide results to a decision maker than the current process. Over 60 publications and reports concerning Cs-137 and sorbents were evaluated. The key attributes were readiness of sorbent to be deployed in a mobile laboratory environment, and minimum sample preparation and conditioning. Examples of sorbents not considered further included nanomaterials, which have not been evaluated at a commercial scale and are limited in availability. The recommended sorbents for further consideration include: ferrocyanide salts, zeolite, and chemically modified granular activated carbon.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study of Classifiers for U-235 Source Signatures Using Gamma Spectral Measurements

Signatures associated with low-level U-235 sources are studied from a classification analytics perspective, using NaI gamma-ray spectral measurements from detectors located at various distances from the source. Data sets collected at a shielded facility are utilized, wherein the source is introduced via a conduit into a formation of 21 NaI detectors deployed over 6 x 6 meters area in a formation of two concentric circles and one spiral. The activity levels in the spectral regions associated with potential U-235 signatures are estimated as counts at 1 second intervals, and are used as features to train classifiers for detecting the presence of the source. Eight different classifiers are trained and tested using the background and source measurements collected over multiple experimental runs. As expected, the classifier performance improved overall as measurements from the detectors closer to source are used, but also revealed unexpectedly low performance by two detectors that are identically produced and configured as others. Six of eight classifiers have an overall comparable performance, for example, three of them achieved zero training error and 99% detection at 4% false alarm rate for a detector located 1.3 meters away from the source. Also, larger training sets led to improved classification performance across all classifiers, and interestingly, the classifiers with the minimum training error did not necessarily achieve the highest classification performance on test data.

Rao, Nageswara↗

Nanoscale solid-state nuclear quadrupole resonance spectroscopy using depth-optimized nitrogen-vacancy ensembles in diamond

Nuclear magnetic resonance (NMR) and nuclear quadrupole resonance (NQR) spectroscopy of bulk quantum materials have provided insight into phenomena, such as quantum phase criticality, magnetism, and superconductivity. With the emergence of nanoscale 2D materials with magnetic phenomena, inductively detected NMR and NQR spectroscopy are not sensitive enough to detect the smaller number of spins in nanomaterials. The nitrogen-vacancy (NV) center in diamond has shown promise in bringing the analytic power of NMR and NQR spectroscopy to the nanoscale. However, due to depth-dependent formation efficiency of the defect centers, noise from surface spins, band bending effects, and the depth dependence of the nuclear magnetic field, there is ambiguity regarding the ideal NV depth for surface NMR of statistically polarized spins. In this work, we prepared a range of shallow NV ensemble layer depths and determined the ideal NV depth by performing NMR spectroscopy on statistically polarized 19 F in Fomblin oil on the diamond surface. We found that the measurement time needed to achieve a signal-to-noise ratio of 3 using XY8-N noise spectroscopy has a minimum at an NV ensemble depth of 5.5 ± 1.5 nm for ensembles activated from 100 ppm nitrogen concentration. To demonstrate the sensing capabilities of NV ensembles, we perform NQR spectroscopy on the 11 B of hexagonal boron nitride flakes. We compare our best diamond to previous work with a single NV and find that this ensemble provides a shorter measurement time with excitation diameters as small as 4 μm. Furthermore, this analysis provides ideal conditions for further experiments involving NMR/NQR spectroscopy of 2D materials with magnetic properties.

2D materials↗

A Decade of Radial-velocity Monitoring of Vega and New Limits on the Presence of Planets

We present an analysis of 1524 spectra of Vega spanning 10 yr, in which we search for periodic radial-velocity variations. A signal with a periodicity of 0.676 day and a semi-amplitude of ∼10 m s{sup −1} is consistent with the rotation period measured over much shorter time spans by previous spectroscopic and spectropolarimetric studies, confirming the presence of surface features on this A0 star. The activity signal appears to evolve on long timescales, which may indicate the presence of failed fossil magnetic fields on Vega. TESS data reveal Vega’s photometric rotational modulation for the first time, with a total amplitude of only 10 ppm. A comparison of the spectroscopic and photometric amplitudes suggests that the surface features may be dominated by bright plages rather than dark spots. For the shortest orbital periods, transit and radial-velocity injection recovery tests exclude the presence of transiting planets larger than 2 R {sub ⊕} and most non-transiting giant planets. At long periods, we combine our radial velocities with direct imaging from the literature to produce detection limits for Vegan planets and brown dwarfs out to distances of 15 au. Finally, we detect a candidate radial-velocity signal with a period of 2.43 days and a semi-amplitude of 6 m s{sup −1}. If caused by an orbiting companion, its minimum mass would be ∼20 M {sub ⊕}; because of Vega’s pole-on orientation, this would correspond to a Jovian planet if the orbit is aligned with the stellar spin. We discuss the prospects for confirmation of this candidate planet.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗