Search NASA⌕ Search

SEARCH · Search NASA

Results for “Molten Nitrate Salt”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Fractal coatings of Ni and NiYSZ for high-temperature corrosion mitigation in solar salt

This paper introduces a novel approach to corrosion mitigation using electrodeposited, fractal Ni and NiYSZ coatings. Highly adherent, durable multiscale coatings with fractal dimensions above 1.80 were fabricated. Corrosion characteristics of coated plain and etched surfaces of In800H, SS310, SS316 and SS347, in comparison to Ha230, were studied in molten 60% NaNO 3 + 40% KNO 3 at 600 °C. The corrosion rate of coated Fe-based alloys reduced by up to 68% compared to uncoated alloys and was on par with or lower than the corrosion rate of Ha230. Furthermore, the corrosion-resistant coatings provide for use of low-cost alloys in high temperature corrosive environments.

36 MATERIALS SCIENCE↗

Mechanical Failure Risk Management for In-Service CSP Nitrate Hot Tanks

The hot thermal energy storage tanks in many operating (Gen2) concentrating solar power plants are designed to contain molten nitrate solar salt at 565 Degrees Celsius and are constructed from 347H stainless steel (SS). From previous work, it is known that 347H SS weldments are potentially susceptible to stress-relaxation cracking (SRC), particularly in the heat-affected zone above 540 Degrees Celsius when no post-weld heat-treatment (PWHT) is performed. However, residual stresses can be reduced when weldments receive PWHT, while at the same time a crack-resistant microstructure is being generated. The overarching goal of this project was to optimize cost-effective, thickness-dependent, localized PWHT procedures and to investigate for feasible non-destructive evaluation (NDE) at commercial scale for hot tanks in Gen2 CSP using 347H SS.

14 SOLAR ENERGY↗

Flexible hose interconnect testing for parabolic troughs with nitrate salt

The use of molten salt as a heat transfer fluid in parabolic trough concentrated solar power plants, in lieu of oil-based heat transfer fluids, presents the possibility to increase the plant's operating temperature and corresponding Rankine cycle efficiency, improve dispatchability, and decrease costs. However, several barriers still exist to commercialization of the technology. This paper discusses meaningful progress toward overcoming two specific barriers to commercialization; 1) the lack of a reliable interconnect solution for molten salt service to connect rotating collectors with stationary header pipes and 2) the limitations of publicly available system modeling tools for a plant using molten salt as both the heat transfer fluid and energy storage medium.

14 SOLAR ENERGY↗

High Toughness Cermets for Molten Salt Pumps

Concentrated Solar Power plants using nitrate salts used cantilevered pump designs to avoid use of bearings in the 565°C salt; however, this necessitated the use of a sump that added additional cost, complexity, and thermal losses. Sump systems had their own complications, including risk of flooding the sump due to control issues either with level indicators or failures in the control valve responsible for filling the sump. Long-shafted pumps were developed and tested, and they outline the need to develop journal sleeves and bearings for new salt systems. Based on reports, pumps will need to be a vertical single- or multi-stage type, mounted to the roof of the molten salt tanks. Design and service for molten salt pumps above 550°C is relatively limited, and at temperatures up to 750°C there is no available design or service experience. Long-shaft pumps that extend to the bottom of the thermal energy storage tank will require bearing materials that are suitable to the given salt chemistry. Lubricity of proposed salts is unclear and need to be determined, especially for cold-tank pumps that require multi-stages for lifting the salt to the top of the tower. Materials, design, and maintenance are all major unknowns.

14 SOLAR ENERGY↗

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects (Final Technical Report)

The number of commercial coal, gas, and nuclear projects built over the past 100 years number in the thousands. As such, there is a large database, available to a wide range of commercial engineering contractors, on proven designs. In essence, unsuccessful designs have, through generations of iterations, been identified and then deleted from further consideration. In contrast, the number of commercial parabolic trough projects using nitrate salt for the thermal storage media is perhaps 60. Further, the number of commercial central receiver projects using nitrate salt as the working fluid is on the order of 20, including estimates for China. Given the relative immaturity of salt technology, and commercial pressures to successfully bid new solar projects into a mature electricity market, solar projects often promise more than has been delivered. The Design Basis Document / Owner’s Technical Specification is a first step in the iteration process. The report describes the successful features of commercial projects, outlines a range equipment and system failures in projects that didn’t operate as intended, and provides a draft set of design changes intended to correct the known problems. The product of the study is 3 volumes of technical material; one volume is on parabolic trough technologies; a second is on central receiver technologies, and the third is on potential design changes to parabolic trough and central receiver projects. The 3 volumes, which total some 590 pages, can be found at https://www.solardynllc.com/csp-plant-technologies. One of the principal topics in the report is the use of functional or prescriptive specifications. Functional specifications describe what the equipment needs to do, consistent with the minimum legal requirements of the local jurisdictions. The details of how this is to be accomplished is developed by the engineering contractor. Prescriptive specifications, which are developed by the Owner, prescribe to the engineering contractor how the functional requirements are to be met. This arrangement ensures that the favorable experience from a previous project is repeated. One example is the design code for the hot salt tank in central receiver projects. The closest design basis is API Standard 650 Welded Steel Tanks for Oil Storage. However, the maximum design temperature in API 650 is 260 °C. As such, solar projects have typically adopted a hybrid Code approach, in which allowable material stresses are taken from ASME Section II Materials. Further, since the tanks experience daily changes in temperature and in (static) pressure, and since portions of the tank can operate at stresses beyond the elastic range, the low cycle fatigue life of the tank is conducted using the rules of Section VIII Division 2. However, in a recent study by NREL, the principal damage mechanism was identified as creep rather than fatigue. Further, design stresses permitted under Section VIII Division 2, corresponding to a fatigue life of 30 years, result in projected creep lifetimes of only 2 to 5 years. An alternate design approach, prescribed by the Owner, would be based on Code sections intended for high temperature service in the creep regime. A candidate is Section III Division 5. Granted, this is a nuclear code section, and it’s use would not likely be mandated by local jurisdictions. However, the effects of creep have been deemed to be of sufficient importance that one nuclear project developer, and one central receiver project developer, have stipulated in the tank design specification that the equipment be designed to the requirements of Section III Division 5.

14 SOLAR ENERGY↗

Predicting and understanding corrosion in molten chloride salts

Abstract Molten chloride salts are stable at higher temperatures than many other salts, including nitrate salts, and are thus promising for heat transfer and/or thermal energy storage in concentrating solar power, nuclear power, and other thermal energy storage applications. However, corrosion in molten chloride salts remains a significant problem. While many studies have been devoted to evaluation of corrosion, we find that a comprehensive method for predicting corrosion in molten chloride salts is lacking. Here, we present an evaluation of corrosion in molten chloride salts using Ellingham diagrams and chloride-oxide stability diagrams, which enable prediction of alloy performance in molten chloride salts and allow corrosion results to be interpreted at a fundamental level. Graphical abstract

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Internal insulation and corrosion control of molten chloride thermal energy storage tanks

A chloride-based molten-salt system that uses a ternary blend of MgCl 2 /KCl/NaCl is investigated to provide higher-temperature thermal energy storage capability than conventional nitrate salt-based systems. Despite their high thermal stability and operating temperature, molten chlorides present several challenges, including the design of internal liners to prevent the corrosion and thermal stress of alloy tank shells. This work discusses issues and potential solutions related to containment of molten chloride salt, specifically the optimization of the hot face refractory materials for use as internal liners. Furthermore, three down-selected refractory materials were analyzed with respect to permeation of salt through the material as well as chemical stability during high temperature operation. Through the application of X-ray imaging and electron spectroscopy techniques, highly stable secondary surface phases in equilibrium with the molten salt were identified, as well as time-dependent changes in the salt composition itself.

25 ENERGY STORAGE↗

Simplified High-Temperature Molten Salt CSP Plant Preconceptual Design

State of the art concentrating solar power plants generally rely on a two-tank system with a large central tower. These plants employ nitrate salts that are limited to approximately 565°C in practice. A novel system arrangement is proposed using molten salt as the heat transfer and energy storage media in a single thermocline storage tank with an integral heat exchanger to the power cycle. The system has unique features that enable temperatures higher than 565°C while reducing costs. This study explores the considerations for the concept and presents a preconceptual point design for a 5 MWt system capable of generating 100 MWt per day with 12 hours of thermal energy storage. This study also examines the potential operation of the system with nitrate and higher temperature chloride salts. Both salt systems appear promising and future concept maturation is recommended.

14 SOLAR ENERGY↗

Development and testing of a solar flux heating freeze recovery system for molten salt parabolic troughs

A major obstacle preventing commercialization of molten salt parabolic trough plants is freeze protection and recovery of the solar field. One of the most common nitrate salt compositions under consideration allows for solar field outlet temperatures up to 565°C and begins solidifying above 240°C. Using molten salt directly in the solar field can significantly reduce thermal energy storage costs and the higher temperature compared to oil heat transfer fluids can power a more efficient power cycle, but the very high freezing point is cause for concern. This work builds on a previous modeling effort investigating different methods for melting Solar Salt frozen in the solar field, which suggested the viability of a novel solar heating method to lower costs of the freeze protection system. In this work higher fidelity models are developed to better investigate the melting process with a more detailed 3D geometry which includes the insulated bellows. The thermal-fluid model of the melting process is updated to include temperature dependent density and data for solid phase properties. In addition, a finite element model is developed to resolve thermal stresses at the point with highest thermal gradients. Results with the new model confirm the viability of using controllable solar flux heating to thaw salt frozen in the solar field without damaging the receiver; however, the presence of non-illuminated sections significantly slows down the melting process. Solar heating simulations with pauses off-sun of 120 and 60 s require 18.5 and 11.9 h to melt salt from a night-time temperature of 10°C with 1000 W m2 DNI, which results in maximum thermal stresses of 48.2 and 53.5 MPa, respectively. Adding 150 W m−1 to the solar heating simulation with a 60 s pause off-sun decreases both the melt time and thermal stresses due to the more uniform heating, suggesting a combined heating method may be the best option.

14 SOLAR ENERGY↗

SMART: Simplified Melting And Rotation-joint Technology

Oil based parabolic trough solar power plants are the most commercially mature CSP technology. However, the upper limit of about 400°C of the current organic heat transfer fluid(HTF)significantly limits the future potential of the technology. Advances in parabolic trough receiver and collector technology have enabled higher operating temperatures of potentially 500°C or above. The search for an improved higher temperature HTF has identified inorganic molten salts, specifically the mix referred to as Solar Salt, a 60:40 mix of sodium nitrate and potassium nitrate salt. However, Solar Salt starts to freeze at about 240°C. This poses a significant challenge for large parabolic trough plants that could have many kilometers of header piping and hundreds of kilometers of receiver piping all filled with molten salt. Plants using molten salt need to be designed to minimize the risk of freezing and to be able to recover from freeze events. Studies and field experiments have shown that this appears to be feasible and the approach appears to have strong economic advantages over conventional trough plants. However, some technical challenges remain related to the use of molten salt in trough solar fields, the cost of the freeze recovery system is significant, and many still question whether the risk of using molten salt is worth the economic upside. In our view, the potential economic upside justifies the continued look at molten salt HTF in parabolic trough plants. The objective of this project was to address the key technical issue remaining, look for opportunities to reduce the cost of the freeze recovery system, and improve the general information and tools available for assessing the design, performance and economics of trough plants using molten salt HTF.

14 SOLAR ENERGY↗

Detection of Off-Gassed Products From Molten Salts Using Laser-Induced Breakdown Spectroscopy

The detection of off-gassed sodium from molten sodium nitrate (NaNO 3 ) at temperatures between 330 °C and 505 °C and off-gassed calcium from molten lithium chloride–potassium chloride eutectic (LKE) mixtures at 510 °C with laser-induced breakdown spectroscopy (LIBS) was demonstrated. NaNO 3 and LKE samples were melted in a custom-built crucible that promoted the generation of off-gassed products from the molten sample. The off-gassed products were analyzed with a LIBS system designed to probe the high-temperature environment. Na D emission lines, Na(I)588.99 nm and Na(I) 589.59 nm, were detected from the NaNO 3 samples after reaching a temperature threshold, which indicated the occurrence of phase change. In LKE mixtures, the detection of Ca impurities at a concentration of 78 mg/kg was possible using the emission lines Ca(II) 393.66 nm and Ca(II) 395.85 nm. Furthermore, this work demonstrates the real-time monitoring capabilities of LIBS in high-temperature environments that simulate the conditions of molten salt reactors.

42 ENGINEERING↗

High-Fidelity and High-Performance Computational Simulations for Rapid Design Optimization of Sulfur Thermal Energy Storage

Industrial process heating (IPH) accounts for approximately 70% of US manufacturing energy use and is primarily produced by fossil fuel combustion. Approximately 1500 TWht (approximately 60%) of IPH demand is in the temperature range of 100-300. Industrial applications in this temperature range include drying, hydrothermal processing, thermal enhanced oil recovery, food and beverage, bioethanol production, etc. Cost-effective thermal energy storage (TES) that increases the utilization of waste and renewable heat (solar, geothermal, etc.) could provide significant energy savings and reliable heat sources, decrease emissions, and increase US manufacturing competitiveness through reductions in fuel consumption. TES development has historically been dominated by technologies suitable for deployment with concentrating solar power (CSP). State-of-the-art thermal storage deployed commercially with power tower CSP plants uses a 60%/40% NaNO3/KNO3 molten salt and operates between temperatures of approximately 280 degrees Celsius and 570 degrees Celsius using a two-tank configuration. However, these nitrate salts are unsuitable for operation outside of this temperature range due to a high freezing point of approximately 220 degrees Celsius, and limits on high-temperature salt stability and corrosion resistance of containment alloys. Other materials being investigated for TES include those based on: (1) sensible energy storage (various molten salt compositions, inert solid particles, rocks or pebble beds, sulfur, water, concrete, graphite, etc.), (2) latent energy storage in materials that undergo solid-liquid phase change at relevant temperatures (organic materials for low-temperature applications, inorganic salts and/or metals for high-temperature applications), or (3) thermochemical energy storage (hydrides, hydroxides, carbonates, metal oxides, etc.). The application temperature and challenges pertaining to storage material and/or containment cost, energy density, long-term thermal and cyclic stability, and charge/discharge heat transfer effectiveness drive material selection for a given IPH or electricity generation application. Sulfur is a cheap commodity at $80/ton compared to $1100 - 1300/ton for conventional salts. When using a metric of storage cost per kWh, sulfur costs around 2-3 $/kWh. Previous sulfur TES development focused on high temperature (>600 degrees) concentrated solar power applications with sulfur encapsulated in pipes and flow of gaseous HTF (air) in the shell side. However, for lower-temperature IPH applications in the range of approximately 100-300 degrees Celsius Element 16 adopted a compact and scalable TES design with molten sulfur in the shell and HTF pipes submerged in the molten sulfur bath. The low-cost molten sulfur TES for dispatchable IPH has deployment potential for broad applications. The spatial and temporal evolution of the HTF and sulfur temperature is critical to the TES system performance, and thus detailed modeling can improve understanding of the performance and facilitate design improvements. Using high performance computing and computational fluid dynamics (CFD) a low-cost molten sulfur thermal energy storage (TES) system for industrial process heating (IPH) applications was developed. The unique challenges in CFD modeling of sulfur TES are the sharp property changes of sulfur relevant to the working temperatures. Above 159, liquid sulfur undergoes polymerization, and the viscosity of sulfur rapidly increases by several orders of magnitude between 159 degrees Celsius and 188 degrees Celsius, followed by a decrease in viscosity beyond 188 degrees Celsius due to thermal bound dissociation. In addition, various concentrations of H2S impurities can also modify sulfur viscosity. This numerical challenge is especially relevant to transient simulation of the sulfur TES charging and discharging processes as the extreme property variations limit the applicability of traditional heat transfer correlations. Transient CFD simulations including the temperature-dependent sulfur properties and geometric complexity of the TES design were used to predict the effect of natural convection during charging and discharging on the heat transfer process, sulfur temperature uniformity, charge/discharge rates, and performance of the storage devices. The CFD model was validated with experimental results for a full charge and discharge cycle. The work will show 3D and 2D simulation comparisons aimed to facilitate rapid design iterations and a machine learning based design optimization approach.

CFD↗

Scaleup and manufacturability of symmetric-structured metal-supported solid oxide fuel cells

Metal-supported solid oxide fuel cells with symmetric architecture, having metal supports on both sides of the cell, are scaled up from button cell size to large 50 cm 2 active area cell size. The cells remain flat after sintering assisted by the symmetric structure. Equivalent performance is achieved for button cells and large cells, and thermal cycling and redox cycling tolerance are demonstrated for the large cells. The catalyst infiltration process is improved to enable high-throughput manufacturing. The cumbersome lab-scale molten nitrate infiltration process is replaced with a room-temperature process in which a shelf-stable aqueous solution of nitrate salts is applied to the cell by spraying, painting, or other scalable techniques. Here, a fast-ramp thermal conversion of the nitrate salts to the final oxide catalyst composition is implemented, allowing many infiltration cycles to be accomplished in a single work shift. Increasing the number of infiltration cycles from 5 to 10 led to an increase in peak power density from approximately 0.3 to 0.52 W cm -2 .

25 ENERGY STORAGE↗

Strong, thermo-reversible salogels with boronate ester bonds as thermal energy storage materials

Inorganic salt hydrates are promising phase change materials (PCMs) but suffer from low viscosity at temperatures above their melting point resulting in leakage problems during thermal storage applications. To achieve shape stabilization of one type of molten inorganic PCM – calcium nitrate tetrahydrate (CNH) – this work explored gelation of polyvinyl alcohol (PVA) in this solvent and the effect of dynamic boronate ester bonds on salogel strength. The occurrence of gelation of PVA in molten CNH but not in water is rationalized by the extremely high salt content and scarcity of hydration water in CNH, enabling intermolecular hydrogen bonding between PVA chains. While neat PVA salogels in CNH were weak, with a gel-to-sol transition temperature (T gel ) below room temperature, the addition of small amounts of borax (<~0.3 wt%) introduced dynamic covalent crosslinks and yielded salogels with T gel tunable over a wide temperature range from 7 to 70 °C. Here, the PVA/borax salogels were about one order of magnitude stronger than their well-known PVA/borax hydrogel counterparts, and, unlike PVA/borax hydrogels, were capable of retaining their shape and preventing leakage of molten CNH. Moreover, the salogels exhibited reversible and repeatable temperature-triggered gel-to-sol transitions and the ability to self-heal. The low polymer and crosslinker concentration also ensured that more than 95% of the heat of fusion of neat CNH was maintained in the salogels and was retained after twenty cycles of melting and crystallization, demonstrating the robust nature of these energy storage materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of RELAP5-3D Code with Molten Salt Heat Transfer Experiments

The accurate thermal-hydraulic assessment of thermal storage systems is crucial for addressing the integrity and performance of the storage system design. This is particularly important for thermal storage systems using molten salts as a heat transport and storage medium, as the chemical corrosion and erosion by the high-temperature molten salts can cause serious damage to the structural components of the storage system. To understand these effects for TerraPower’s Natrium® Demonstration Reactor design, the system thermal-hydraulic analysis code, RELAP5-3D, is utilized to analyze the thermal storage system. This study evaluates two heat transfer correlations implemented in the RELAP5-3D code—the Dittus-Boelter and Gnielinski correlations—using selected benchmark cases from two molten salt heat transfer experiments conducted at Xi’an Jiao Tong University and the German Aerospace Center. The Nusselt numbers calculated using the Gnielinski correlation agree with the experimental data within ±5% of the relative deviations at 300°C and 400°C. With the increasing Reynolds numbers, the Dittus-Boelter correlation underestimates the Nusselt numbers by up to 22% compared to the Gnielinski correlation. Comparison of the RELAP5-3D calculation results with experimental data at a high temperature of 550°C revealed that the thermo-chemical characteristics of solar salt at high temperatures surpassing the decomposition temperatures of nitrate salts reduce the accuracy of heat transfer model of the RELAP5-3D code. Specifically, it has been observed that the temperatures of the wall surface and liquid near the wall can surpass the decomposition temperatures, even though the bulk temperature of molten salts remains significantly lower than these decomposition temperatures. In summary, this study recommends the use of the Gnielinski correlation for the heat transfer analysis of molten salt, rather than the Dittus-Boelter correlation.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Technical Performance of Refractory Liners for Molten Chloride Salt Thermal Energy Storage Systems

A chloride-based molten-salt system that uses a ternary blend of MgCl2/KCl/NaCl is investigated to provide higher temperature thermal energy storage capability. Despite higher thermal stability, molten chlorides present several unique challenges, including the design of internal refractory-ceramic liners to prevent the corrosion and thermal stress of alloy tank shells. This work discusses issues and potential solutions related to containment of molten chloride salt, specifically the optimization of the refractory material at the molten salt interface (hot face). The down-selected hot face candidate limits permeation of salt through the material and forms a highly stable secondary surface phase in equilibrium with the molten salt. A mortar is created using the corrosion resistant hot face brick. Brick and mortar composite are subjected to mechanical stress/strain analysis, in order to calculate composite material properties and better inform thermomechanical models. The U.S. Department of Energy Generation 3 (DOE Gen3) program seeks to develop higher efficiency CSP plants that can provide cost-competitive, flexible power in the U.S. electric grid. The proposed Gen3 Liquid Pathway CSP plant closely resembles the configuration of current nitrate salt power towers with two-tank storage (Gen2). The differences between Gen2 and Gen3 include the types of compatible materials used in salt storage tank construction. Stainless steel loses strength at Gen3 temperatures, and although nickel superalloys would be capable of withstanding sustained high temperatures, these materials are prohibitively expensive at scale. Uninsulated tank shells also pose a significant risk as common steels are highly susceptible to chemical attack from molten chloride salt. To address these concerns, refractory-ceramic based containment materials are proposed to line the inside of the hot and cold storage tanks. In doing so, stainless or carbon steel shells may be used in construction depending on the level of insulation provided. The composition of the internal liner requires careful consideration to maximize the efficacy of multiple parameters including corrosion resistance, strength at operating temperature, durability, and cost. This is particularly true for the material at the interface with the salt, known as the "hot face", which is responsible for protecting the insulating layers between the tank shell and the hot face brick layer. The molten salt in this system is superheated over 300 °C above its freeze temperature. Therefore, unlike other industrial processes which use refractory-lined vessels, it is not expected that a freeze plane will develop in the hot face. Therefore, the hot face must be designed to withstand chemical corrosion and inhibit permeation of molten salt into the insulating layers. A down selection was performed to identify a hot face candidate best equipped to maintain thermal, mechanical, and chemical integrity when exposed to molten salt over extended periods of time. Long-duration chemical capability experiments were conducted with the down selected hot face refractory fully immersed in molten chloride salt for up to 3000 hours. The average salt penetration does not exceed 100 microns. When extrapolated to 20 and 30 years of continuous exposure, the expected salt penetration depth is approximately 2.0 mm and 2.9 mm, respectively. A magnesium-rich secondary phases develops at the salt/refractory interface. X-ray diffraction identifies the material as forsterite (Mg2SiO4), which is reported to form synthetically in molten chloride salt solutions. These results suggest the selected hot face will adequately inhibit salt permeation. While there is optimism that the hot face brick will inhibit salt permeation, mortar joints are typically the weakest point of a refractory brick liner. From a thermochemical perspective, differing thermal expansion coefficients may result in the mortar and brick to grow independent of each other, creating gaps through which molten salt can penetrate. To address this issue, NREL has developed an in-house mortar composed of the down selected hot face brick that has been shown to be compatible with the salt. Compressive stress/strain analyses have been performed on the brick/ mortar composites to generate stress/strain curves. Modulus of elasticity and Poisson's ratio of the composite may be calculated from the stress/strain curves, in order to provide more representative data to finite element mechanical models for accurate approximation of stress on the tank shell and the amount of thermal expansion expected within the tank liner.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Application of Raman Spectroscopy to Determine Uranium Content in ADUN Solution

The work presented in this report is part of the ongoing efforts to address the nuclear material control and accounting needs for advanced reactor fuel fabrication facilities. This work was supported by the Materials Protection, Accounting, and Control Technologies (MPACT) program under the US Department of Energy Office of Nuclear Energy‘s Nuclear Fuel Cycle and Supply Chain program. The activities and engagements under the MPACT program are designed to support a robust US civilian nuclear energy enterprise. In the work described in this report, we supported MPACT objectives by developing measurement techniques that could be used for material accounting and process monitoring and by working with industry partners to identify existing gaps and areas for improvement. Oak Ridge National Laboratory has been working with commercial tristructural isotropic (TRISO) fuel fabricators such as Standard Nuclear to develop technology for rapid and cost-effective uranium content assessment. This work has focused on demonstrating advanced measurement techniques (e.g., Raman spectroscopy) that can be used for rapid, reliable, and cost-effective routine measurements of uranium content in feed solutions and liquid waste streams as well as for monitoring in-line process measurements and product streams. Specifically, this report explores techniques for accurately determining uranium content in acid-deficient uranyl nitrate (ADUN) solutions and detecting low uranium concentrations in ammonia solutions. Developing such measurement techniques will benefit TRISO fuel fabrication facilities, facilities involved in other parts of the fuel cycle that require online monitoring of aqueous solutions, and potentially molten salt fuel reactors. This work supports developing Raman spectroscopy procedures to determine uranium concentrations in ADUN solutions, which are used as feedstock in the sol–gel process for creating TRISO fuel. Some additional benefits of using Raman spectroscopy for uranium quantification in fabrication facilities include enabling online monitoring of the chemical process, which would provide near real-time feedback; eliminating the need for sample transfers, preparation, or dilution; providing nondestructive measurements; and user friendliness. In this fiscal year, FY25, we determined the identity of the unknown Raman band at approximately 853 cm−1 that was discovered in ADUN Raman spectra in FY24, created calibration curves and determined uranium concentrations of two ADUN solutions, and compared the Raman results to results obtained from inductively coupled plasma mass spectrometry and Davies–Gray titration. Furthermore, we have identified focus areas for experimentation in future fiscal years. A key result is that the accuracy of using Raman can provide accuracy comparable to destructive analysist techniques, With a well-developed calibration curve, using standards and a large number of samples (more than five samples), uncertainty on the order of 1%–3% is achievable. Given that the uncertainties achieved by Raman spectroscopy were on the order of the uncertainties achieved using ICP-MS, we conclude that with a well-developed procedure Raman spectroscopy can be used to determine uranium concentrations in ADUN solutions for NMC&A applications. The benefits of such an approach are that the time and effort will be less than that of comparable destructive analysis techniques, with approximately the same level of technical expertise. This will be attractive to operators of fuel fabrication facilities as it will lower costs and improve efficiencies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Planar-Cavity Receiver Configuration for High-Temperature Solar Thermal Processes: Preprint

Next generation concentrating solar thermal power (CSP) and novel solar thermochemical systems using concentrating solar thermal (CST) energy require high operating temperatures exceeding those of traditional nitrate-salt CSP systems. Particle-based systems are attractive for next-generation CSP and CST applications owing to high-temperature stability of inert silica- or alumina-based particulate materials, the lack of low-temperature freezing concerns that limit molten salt and/or molten metal heat transfer media, and cost-effective thermal storage using low-cost particulate and containment materials. Open-cavity falling particle receivers have many potential advantages, but face challenges pertaining to scalability, thermal loss, and particle loss through the open aperture, and are infeasible for chemical processes that require a low-oxygen ambient environment. Enclosed receiver configurations can be scalable, avoid particle loss when heating particles, and have potential for future chemical processes; however, particle-based heat transfer media provide substantially lower heat transfer rates than liquid media, and thus enclosed particle receiver designs require novel configurations to limit surface temperatures under the high incident solar flux concentrations necessary for high receiver thermal efficiency at high temperature. This paper introduces the novel planar-cavity enclosed particle receiver configuration in which arrays of planar surfaces are arranged into sub-vertical cavities. Large angles between the panel surface normal vectors and the aperture surface normal allow the incoming solar beam to distribute along the panel walls. Correspondingly, a high incident solar flux concentration at the cavity aperture produces substantially lower absorbed solar flux concentration on any panel wall. Sets of individual vertical cavities can be arranged to form a scalable receiver configuration.

cavity receiver↗