Tumbler system to provide random motion
Tumbling motion system for object demagnetization
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Tumbling motion system for object demagnetization
— Motion and visual cue influences are critical in any simulator system, as they impact multiple aspects of the human’s neurovestibular and visual systems. Cues of real motion proceeds to the brain before cues of visual change. It is important therefore for simulator motion cues to exist and to match those realistically with those of the real vehicle to provide transferable training of the activity for operations. The United Kingdom’s Royal Air Force Institute of Aviation Medicine (1989)[1] stated that motion platforms are the only simulation devices capable of fully stimulating the body motion sensors. They confirmed that motion platforms can impart accelerations to the whole body and therefore exercise the automatic motion feedback-loop that operators are used to. With both visual and motion cues handling the vehicle becomes more realistic. Strachan (2019)[1] confirms motion cueing from a well set-up motion platform has been found to be important especially in conditions such as night or reduced visibility where motion cues may be more relied upon. As of this writing, the only lunar rover motion simulator is housed at the General Motors (GM) Milford Proving Ground, which only simulates the motions of a traditional car. A NASA Test Team proposed to complete a motion-based simulation system for NASA’s Lunar Terrain Vehicle (LTV) which resides at Johnson Space Center’s Systems Engineering Simulator facility. This activity integrated existing fixed base simulation capabilities with a newly procured six-degree of freedom motion base platform for the design, development, evaluation, and training associated with the LTV project. This would incorporate a South Pole Lunar virtual reality simulation using Lunar Reconnaissance Orbiter 5m/pixel high-resolution imagery and Unreal 5.2 Virtual Shadow Maps, combined with a virtual reality (VR) headset, integrated within a rover cockpit on a Mikrolar Motion Platform for evaluating human performance and vehicle handling qualities for concept roving vehicle designs. The motion-based system received its Human Rating Certification on March 2023. To begin testing the new facility, a preliminary handling qualities study was conducted. The objectives were to determine if there is a correlation amongst three handling quality methods of performance for a lunar vehicle and to understand the effects of a simulated 1/6-g loads and visuals with a motion platform on the operator while in a 1-g physical environment. The capability this system provides directly benefits the NASA’s Extravehicular Activity and Human Surface Mobility Program and NASA’s Flight Operations Directorate in evaluating the driving qualities of vehicle concepts, human performance related to the operating of a lunar surface vehicle, and assessment of suit related driving impacts. It would also provide direct operational benefit by providing a first-in class and unique simulation platform for the lunar astronaut training curriculum. The empirical knowledge of rover and human performance on this scale is paramount as there is currently no other lunar surface simulator with these capabilities. The result of this study ensures a broadly applicable method of testing for shirtsleeve, unpressurized and pressurized suited rover handling qualities.
The paper examines the evolution of manned aircraft simulators with large-motion systems and provides a brief description of important design details along with physical descriptions of a number of systems. Attention is given to the use of large translational motions in providing the simulator pilot with a close approximation of the cues of aircraft flight; examples are cited comparing pilot reactions to simulators with and without motion. How these simulators have been used in programs that effectively influenced aircraft design and operating problems is discussed.
Several techniques to perform static and dynamic load balancing techniques for vision systems are presented. These techniques are novel in the sense that they capture the computational requirements of a task by examining the data when it is produced. Furthermore, they can be applied to many vision systems because many algorithms in different systems are either the same, or have similar computational characteristics. These techniques are evaluated by applying them on a parallel implementation of the algorithms in a motion estimation system on a hypercube multiprocessor system. The motion estimation system consists of the following steps: (1) extraction of features; (2) stereo match of images in one time instant; (3) time match of images from different time instants; (4) stereo match to compute final unambiguous points; and (5) computation of motion parameters. It is shown that the performance gains when these data decomposition and load balancing techniques are used are significant and the overhead of using these techniques is minimal.
This work characterizes the accuracy of a 16 camera OptiTrack motion tracking system installed in NASA Glenn Research Center's Simulated Lunar Operations (SLOPE) laboratory. The position of a rigid body mounted on a motorized linear stage is compared to its position reported by the motion tracking system as it travels through the facility's 777m$^3$ capture volume of interest. Experiments show that the mean error reported by the motion tracking system for the aggregate capture volume is in-line with independent measurements collected using the motion stage. Error within regions of the capture volume exceed the mean error reported by the motion tracking system, likely due to occlusion, and suggests that additional cameras should be used to increase measurement accuracy in these regions. Overall, results show that error values reported by the motion tracking system are representative of the measurement error in a collected data set and validates the system's use for characterizing the mobility and tractive performance of robots, rovers, and other vehicles for planetary exploration.
Optoelectronic system to monitor motions of turbopump shaft developed. Optical sensors detect passage of reflective triangles on shaft. Optical measurements processed in real time into indications of speed of rotation and of axial and lateral displacements of shaft.
Software development for the Trospheric Air Motion Measurement Systems (TAMMS) is documented. In July/August the TAMMS was flown on the NASA/Goddard Flight Center Electra aircraft for 19 mission for the ABLE-2A (Amazon Boundary Layer Experiment) in Brazil. In December 1985, several flights were performed to assess the contamination and boundary layer of the Electra. Position data, flow angles, pressure transducer measurements were recorded. The programs written for the ABLE-2A were modified due to timing considerations for this particular program. The 3-step programs written for EBLE (Electra Boundary Layer Experiment) are described. Power up and log-on procedures are discussed. A few editing techniques are described for modification of the programs.
The Device for Orientation and Motion Environments Preflight Adaptation Trainer (DOME PAT) provides astronauts a virtual microgravity sensory environment designed to help alleviate tye symptoms of space motion sickness (SMS). The system consists of four microcomputers networked to provide real time control, and an image generator (IG) driving a wide angle video display inside a dome structure. The spherical display demands distortion correction. The system is currently being modified with a new graphical user interface (GUI) and a new Silicon Graphics IG. This paper will concentrate on the new GUI and the networking scheme. The new GUI eliminates proprietary graphics hardware and software, and instead makes use of standard and low cost PC video (CGA) and off the shelf software (Microsoft's Quick C). Mouse selection for user input is supported. The new Silicon Graphics IG requires an Ethernet interface. The microcomputer known as the Real Time Controller (RTC), which has overall control of the system and is written in Ada, was modified to use the free public domain NCSA Telnet software for Ethernet communications with the Silicon Graphics IG. The RTC also maintains the original ARCNET communications through Novell Netware IPX with the rest of the system. The Telnet TCP/IP protocol was first used for real-time communication, but because of buffering problems the Telnet datagram (UDP) protocol needed to be implemented. Since the Telnet modules are written in C, the Adap pragma 'Interface' was used to interface with the network calls.
Current literature lacks a comparative analysis of different motion capture systems for tracking upper limb (UL) movement as individuals perform standard tasks. To better understand the performance of various motion capture systems in quantifying UL movement in the prosthesis user population, this study compares joint angles derived from three systems that vary in cost and motion capture mechanisms: a marker-based system (Vicon), an inertial measurement unit system (Xsens), and a markerless system (Kinect). Ten healthy participants (5F/5M; 29.6 ± 7.1 years) were trained with a TouchBionic i-Limb Ultra myoelectric terminal device mounted on a bypass prosthetic device. Participants were simultaneously recorded with all systems as they performed standardized tasks. Root mean square error and bias values for degrees of freedom in the right elbow, shoulder, neck, and torso were calculated. The IMU system yielded more accurate kinematics for shoulder, neck, and torso angles while the markerless system performed better for the elbow angles. By evaluating the ability of each system to capture kinematic changes of simulated upper limb prosthesis users during a variety of standardized tasks, this study provides insight into the advantages and limitations of using different motion capture technologies for upper limb functional assessment.
A two-axis motion simulation system for thermal vacuum testing of large satellites in a space simulation chamber was developed. Satellites as large as 3000 kilograms with a 4-meter diameter and a 5-meter length can be tested. This motion simulator (MS) incorporates several unique features which result in a less complicated design with improved performance when compared to previous satellite motion simulators. The design of the simulator is discussed in detail.
An operational system for extracting ice-motion information from synthetic aperture radar (SAR) imagery is being developed as part of the Alaska SAR Facility. This geophysical processing system (GPS) will derive ice-motion information by automated analysis of image sequences acquired by radars on the European ERS-1, Japanese ERS-1, and Canadian RADARSAT remote sensing satellites. The algorithm consists of a novel combination of feature-based and area-based techniques for the tracking of ice floes that undergo translation and rotation between imaging passes. The system performs automatic selection of the image pairs for input to the matching routines using an ice-motion estimator. It is designed to have a daily throughput of ten image pairs. A description is given of the GPS system, including an overview of the ice-motion-tracking algorithm, the system architecture, and the ice-motion products that will be available for distribution to geophysical data users.
Attention is given to the class of ground based devices which have been used by scientists, engineers, and test pilots to evaluate current or future aircraft systems. The characteristics of a flight simulator and its major subsystems are considered, taking into account simulator cockpits, visual scene attachments, aspects of visual attachment fidelity, simulator motion systems, motion system fidelity, and simulation computer systems. Questions related to psychological research and simulation are examined. Simulator validity criteria are discussed along with problems of subsystem fidelity.
This presentation summarizes the current expansion of the Fuel Motion Monitoring System
Motion drive system has been developed for use with interferometers where accurate control of minuscule distance in the 1-micron range is of prime importance. The drive system is applicable to any device that requires extremely accurate positioning control.
The concept, implementation, and performance of the motion detection system (MDS) designed as a diagnostic for X-ray ground testing for AXAF are described. The purpose of the MDS is to measure the magnitude of a relative rigid body motion among the AXAF test optic, the X-ray source, and X-ray focal plane detector. The MDS consists of a point source, lens, centroid detector, transimpedance amplifier, and computer system. Measurement of the centroid position of the image of the optical point source provides a direct measure of the motions of the X-ray optical system. The outputs from the detector and filter/amplifier are digitized and processed using the calibration with a 50 Hz bandwidth to give the centroid's location on the detector. Resolution of 0.008 arcsec has been achieved by this system. Data illustrating the performance of the motion detection system are also presented.
The Idaho National Laboratory (INL) Transient Reactor Test Facility (TREAT) Fuel Motion Monitoring System (FMMS) is a diagnostic tool used to visualize the movement and location of fuel within the nuclear reactor during transient experiments. TREAT is designed to test the behavior of nuclear fuel under accident conditions, such as a rapid power increase. The TREAT FMMS, also referred to as the “hodoscope” because of the system’s massive steel collimator component, is located on the North beam port of the reactor. While the FMMS system is capable of incorporating a total of 360 sensors, initial refurbishment efforts resulted in a array of 96 fast neutron detectors. This initial array was configured to provide a narrow (2 channels) full-length view of experiment vessels with an extended 4-channel–wide region in the center of the array capable of providing a full view of all initially planned experiments. Planning and efforts to expand the FMMS array began immediately following the restart of TREAT. An additional 96 detectors were evaluated, characterized, and prepared for installation at TREAT during the summer of 2018. Unfortunately, funding reductions forced the project towards a 5-year hiatus. In October of 2023 funding from the Department of Energy’s Nuclear Science User Facilities enabled the expansion to recommence. This report serves to document the activities performed to expand the FMMS detector array to 192 channels in order to provide a broader view of the larger and more sophisticated test capsules currently planned for future irradiation in the TREAT reactor. This expansion also included doubling the data acquisition capability, addressing the new heat load on the system, and synchronizing the time for all digital components.
The development of a noncontacting motion sensing system designed to monitor the movement of a cart along a track in the low earth orbit space environment is described. The system uses Hall effect sensors to detect the position of small permanent magnets located along the track. The measurement criteria are described, the system design is discussed, and estimates of the system error are given. The system will be used on the Crew and Equipment Translation Aid (CETA) experiment scheduled for the STS37 flight in November 1990. It will allow the position, velocity, and acceleration of the cart to be determined as it moves along the track.
It is common to have liquid crystal displays and electronic circuit boards with area sizes of the order of 20x20 sq cm on board of satellites and space vehicles. Usually irradiating them at different fluence values assesses the radiation damage in these types of devices. As a result, there is a need for a radiation source with large spatial fluence uniformity for the study of the damage by radiation from space in those devices. Kent State University s Program on Electron Beam Technology has access to an electron accelerator used for both research and industrial applications. The electron accelerator produces electrons with energies in the interval from 1 to 5 MeV and a maximum beam power of 150 kW. At such high power levels, the electron beam is continuously scanned back and forth in one dimension in order to provide uniform irradiation and to prevent damage to the sample. This allows for the uniform irradiation of samples with an area of up to 1.32 sq m. This accelerator has been used in the past for the study of radiation damage in solar cells (1). However in order to irradiate extended area solar cells there was a need to measure the uniformity of the irradiation zone in terms of fluence. In this paper the methodology to measure the fluence uniformity on a sample handling system (linear motion system), used for the irradiation of research samples, along the irradiation zone of the above-mentioned facility is described and the results presented. We also illustrate the use of the electron accelerator for the irradiation of large area solar cells (of the order of 156 sq cm) and include in this paper the electrical characterization of these types of solar cells irradiated with 5 MeV electrons to a total fluence of 2.6 x 10(exp 15) e/sq cm.