Search NASA⌕ Search

SEARCH · Search NASA

Results for “Multiplexing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Spatiotemporal multiplexing based on hexagonal multicore optical fibres

Based on a genetic algorithm, we have solved in this paper the problem of finding the parameters of optical Gaussian pulses which make their efficient nonlinear combining possible in one of the peripheral cores of a 7-core hexagonal fibre. Two approaches based on individual selection of peak powers and field phases of the pulses launched into the fibre are considered. Finally, the found regimes of Gaussian pulse combining open up new possibilities for the development of devices for controlling optical radiation.

36 MATERIALS SCIENCE↗

Two-Level Switches for Advanced Time-Division Multiplexing

Superconducting quantum interference device (SQUID)-based time-division multiplexing (TDM) is a mature and widely implemented technology used to read out transition-edge sensor arrays. As the number of pixels in modern arrays continues to increase, a higher multiplexing factor is required to reduce the number of wires and amplifier channels. Yet, as the multiplexing factor is increased, the number of row-select wires (used to turn on a row of TDM SQUIDs in a two-dimensional configuration) also increases, limiting the reduction in array wires. We introduce a more advanced TDM architecture that enforces multi-level switching between subgroups of pixels. We show that this technique can dramatically reduce the number of required row-select lines. We also present the design, fabrication, and testing of a TDM multiplexer incorporating a two-level switch, which implements a second switch for each group of ten TDM pixels. In this application, a multiplexing factor of 100 can be addressed using ten group-select wiring pairs and ten row-select wiring pairs. We demonstrate multiplexer functionality and present measured operating margins of this new TDM multiplexer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dielectric Broadband Metasurfaces for Fiber Mode-Multiplexed Communications

A subwavelength-thick spatial-mode multiplexer based on a highly transparent all-dielectric Mie-resonant metasurface is demonstrated with a broadband response covering major optical communication wavelength bands. The metasurface is employed to convert simultaneously each orthogonal polarization of LP 01 inputs into individual higher-order TM 01 and TE 01 vectorial modes, without the need of a polarization diversity setup. This is not feasible using current mode multiplexing approaches. An LP 01 polarization-multiplexed 51×64-QAM superchannel, with a 10.3 bits/s/Hz spectral-efficiency and total bit-rate of 13.2 Tb/s, is converted to higher-order modes with the metasurface multiplexer, and then mode-multiplexed data is transmitted over a multimode fiber. The results demonstrate the potential application of these metadevice-based mode multiplexers in space-division multiplexed systems.

36 MATERIALS SCIENCE↗

A Scalable Readout for Microwave SQUID Multiplexing of Transition-Edge Sensors

The readout requirements for instruments based on transition-edge sensors (TESs) have dramatically increased over the last decade as demand for systems with larger arrays and faster sensors has grown. Emerging systems are expected to contain many thousands of sensors and/or sensors with time constants as short as 100 ms. These requirements must be satisfied while maintaining low noise, high dynamic range, and low crosstalk. A promising readout candidate for future TES arrays is the microwave SQUID multiplexer, which offers several gigahertz of readout bandwidth per pair of coaxial cables. In microwave SQUID multiplexing, sensor signals are coupled to RF-SQUIDs embedded in superconducting microwave resonators, which are probed via a common microwave feedline and read out using gigahertz signals. This form of SQUID multiplexing moves complexity from the cryogenic stages to room temperature hardware and digital signal processing firmware which must synthesize the microwave tones and process the information contained within them. To demultiplex signals from the microwave SQUID multiplexer, we have implemented an FPGA-based firmware architecture that is flexible enough to read out a variety of differently optimized TESs. A gamma-ray spectrometer targeted at nuclear materials accounting applications, known as SLEDGEHAMMER, is an early adopter of microwave SQUID multiplexing and is driving our current firmware development effort. This instrument utilizes 300 kHz full-width half-maximum resonators with 256 channels in a one gigahertz wide band. We have recently demonstrated undegraded readout of 128 channels using two ROACH2s on a single pair of coaxial cables. This manuscript describes the firmware implementation for the readout electronics of these early array-scale demonstrations.

42 ENGINEERING↗

Frequency domain multiplexing of pulse mode radiation detectors

The capability to multiplex scintillation detectors or other pulse mode radiation detectors is necessary in some applications where a large number of detectors is required. Frequency domain multiplexing has been previously implemented for applications in astronomy using amplitude modulation on radiation detectors such as transition-edge sensors. We propose here an alternative method for multiplexing pulse mode radiation detectors in the frequency domain using convolution. We pass the detector signal to a resonator circuit that converts a detector pulse to a damped sinusoid of a specific frequency which gives a unique tag to the detector. We have developed a prototype frequency-domain multiplexed system for four EJ-309 organic scintillator detectors using four resonators of unique frequencies. The resonator outputs are combined using a fan-in circuit which is then connected to a single digitizer input. Using this system, we further demonstrate that the charge collected under the original anode pulse can be estimated from the power spectrum of the damped sinusoid with a relative uncertainty of about 2%. The time-of-arrival of the anode pulse can be estimated using constant fraction discrimination applied to the leading edge of the damped sinusoid with an uncertainty of about 450 ps. We also used a CeBr3 detector to test the performance of our system for spectroscopic applications and found only small degradation in the resolution for a multiplexed detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Convolution-based frequency domain multiplexing of SiPM readouts using the $\mathrm{DRS4}$ digitizer

Here we present 4:1 multiplexing of organic scintillators, each coupled to a silicon photomultiplier (SiPM), to reduce the need for a large number of digitizer input channels to readout highly pixelated radiation detection systems. Frequency domain multiplexing (FDM) encodes a detector pulse by assigning it a unique frequency via convolution before combining the encoded signal into a single channel. The combined signal is then read through a digitizer input channel. We have designed an FDM system to multiplex four SiPMs using DRS4 digitizer evaluation board from Paul Scherrer Institute (PSI). We demonstrate 4:1 multiplexing of the SiPM fast output signals and pulse recovery from the digitized multiplexed signal using deconvolution. The noise in the recovered pulse introduces a bias and uncertainty in the estimate of energy and timing that changes with pulse height. The relative uncertainty in the estimated energy from the recovered pulse decreases with pulse height with a maximum uncertainty of 3.1% for the low energy pulses (corresponding to 100 keV); the uncertainty in the estimated time pick-off also decreases with pulse height with a maximum uncertainty of 110 ps for the low energy pulses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

White noise of Nb-based microwave superconducting quantum interference device multiplexers with NbN coplanar resonators for readout of transition edge sensors

White noise of dissipationless microwave radio frequency superconducting quantum interference device (RF-SQUID) multiplexers has been experimentally studied to evaluate their readout performance for transition edge sensor (TES) photon counters ranging from near infrared to gamma ray. The characterization has been carried out at 4 K, first to avoid the low-frequency fluctuations present at around 0.1 K, and second, for a feasibility study of readout operation at 4 K for extended applications. To increase the resonant Q at 4 K and maintain low noise SQUID operation, multiplexer chips consisting of niobium nitride (NbN)-based coplanar-waveguide resonators and niobium (Nb)-based RF-SQUIDs have been developed. This hybrid multiplexer exhibited 1 × 10{sup 4} ≤ Q ≤ 2 × 10{sup 4} and the square root of spectral density of current noise referred to the SQUID input √S{sub I} = 31 pA/√Hz. The former and the latter are factor-of-five and seven improvements from our previous results on Nb-based resonators, respectively. Two-directional readout on the complex plane of the transmission component of scattering matrix S{sub 21} enables us to distinguish the flux noise from noise originating from other sources, such as the cryogenic high electron mobility transistor (HEMT) amplifier. Systematic noise measurements with various microwave readout powers P{sub MR} make it possible to distinguish the contribution of noise sources within the system as follows: (1) The achieved √S{sub I} is dominated by the Nyquist noise from a resistor at 4 K in parallel to the SQUID input coil which is present to prevent microwave leakage to the TES. (2) The next dominant source is either the HEMT-amplifier noise (for small values of P{sub MR}) or the quantization noise due to the resolution of 300-K electronics (for large values of P{sub MR}). By a decrease of these noise levels to a degree that is achievable by current technology, we predict that the microwave RF-SQUID multiplexer can exhibit √S{sub I} ≤ 5 pA/√Hz, i.e., close to √S{sub I} of state-of-the-art DC-SQUID-based multiplexers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multiplexed measurements by time resolved spectroscopy using colloidal CdSe/ZnS quantum dots

Multiplexed measurements of analytes in parallel is a topical demand in bioanalysis and bioimaging. An interesting alternative to commonly performed spectral multiplexing is lifetime multiplexing. In this Letter, we present a proof of principle of single-color lifetime multiplexing by coupling the same fluorophore to different nanoparticles. The effective lifetime of the fluorophores can be tuned by more than one order of magnitude due to resonance energy transfer from donor states. Measurements have been done on a model systems consisting of ATTO-590 dye molecules linked to either gold particles or to CdSe/ZnS core shell quantum dots. Both systems show the same luminescence spectrum of ATTO-590 dye emission in continuous wave excitation, but can be distinguished by means of time resolved measurements. The dye molecules bound to gold particles exhibit a mono-exponential decay with a lifetime of 4.5 ns, whereas the dye molecules bound to CdSe/ZnS dots show a nonexponential decay with a slow component of about 135 ns due to the energy transfer from the quantum dots. We demonstrate the fundamental possibility to determine the mixing ratio for dyes with equal luminescence spectra but very different transients. This opens up a pathway independent of the standard optical multiplexing with many different fluorophores emitting from the near ultraviolet to the near infrared spectral region.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Efficient Sampling of Complex Interdependent and Multiplex Networks

Efficient sampling of interdependent and multiplex infrastructure networks is critical for effectively applying failure and recovery algorithms in real-world settings, as well as to generate property-preserving reduced-order graph-based ensembles that address topological uncertainties. In this paper, we first explore the performance, i.e. the success in preserving graph properties, of graph sampling algorithms for interdependent and multiplex networks with synthetic and real-world graphs. We simulate sampling algorithms under different parameter settings. These settings include probabilistic graph generators, coupling patterns, and various performance metrics. Our results show that while Random Node and Random Walk sampling algorithms perform best for interdependent networks, Random Edge and Forest Fire sampling algorithms perform best for multiplex networks. Second, we propose and implement a novel similarity-based sampling algorithm for multiplex networks that samples only log(N) number of layers of an N-layer multiplex network while yielding computational savings with performance guarantees. Experimental results show that similarity sampling outperforms complete sampling of all layers while decreasing performance costs from a linear scale to a logarithmic one. Our results also indicate that similarity-based sampling outperforms complete sampling and random selection in nearly all scenarios when tested with real-world data.

Subasi, Omer↗

Optical delay encoding for fast timing and detector signal multiplexing in PET

Purpose: The large number of detector channels in modern positron emission tomography (PET) scanners poses a challenge in terms of readout electronics complexity. Multiplexing schemes are typically implemented to reduce the number of physical readout channels, but often result in performance degradation. Novel methods of multiplexing in PET must be developed to avoid this data degradation. The preservation of fast timing information is especially important for time-of-flight PET. Methods: A new multiplexing scheme based on encoding detector interaction events with a series of extremely fast overlapping optical pulses with precise delays is demonstrated in this work. Encoding events in this way potentially allows many detector channels to be simultaneously encoded onto a single optical fiber that is then read out by a single digitizer. A two channel silicon photomultiplier-based prototype utilizing this optical delay encoding technique along with dual threshold time-over-threshold is demonstrated. Results: The optical encoding and multiplexing prototype achieves a coincidence time resolution of 160 ps full width at half maximum (FWHM) and an energy resolution of 13.1% FWHM at 511 keV with 3 × 3 × 5 mm{sup 3} LYSO crystals. All interaction information for both detectors, including timing, energy, and channel identification, is encoded onto a single optical fiber with little degradation. Conclusions: Optical delay encoding and multiplexing technology could lead to time-of-flight PET scanners with fewer readout channels and simplified data acquisition systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary Assessment of Microwave Readout Multiplexing Factor

Ultra-high resolution microcalorimeter gamma spectroscopy is a new non-destructive assay technology for measurement of plutonium isotopic composition, with the potential to reduce total measurement uncertainty to a level competitive with destructive analysis methods [1-4]. Achieving this level of performance in practical applications requires not only the energy resolution now routinely achieved with transition-edge sensor microcalorimeter arrays (an order of magnitude better than for germanium detectors) but also high throughput. Microcalorimeter gamma spectrometers have not yet achieved detection efficiency and count rate capability that is comparable to germanium detectors, largely because of limits from existing readout technology. Microcalorimeter detectors must be operated at low temperature to achieve their exceptional energy resolution. Although the typical 100 mK operating temperatures can be achieved with reliable, cryogen-free systems, the cryogenic complexity and heat load from individual readout channels for large sensor arrays is prohibitive. Multiplexing is required for practical systems. The most mature multiplexing technology at present is time-division multiplexing (TDM) [3, 5-6]. In TDM, the sensor outputs are switched by applying bias current to one SQUID amplifier at a time. Transition-edge sensor (TES) microcalorimeter arrays as large as 256 pixels have been developed for X-ray and gamma-ray spectroscopy using TDM technology. Due to bandwidth limits and noise scaling, TDM is limited to a maximum multiplexing factor of approximately 32-40 sensors on one readout line [8]. Increasing the size of microcalorimeter arrays above the kilopixel scale, required to match the throughput of germanium detectors, requires the development of a new readout technology with a much higher multiplexing factor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Four Channel Time Multiplexed Photonic Doppler Velocimetry using an Optical Switch

Photonic Doppler Velocimetry (PDV) is a diagnostic commonly used in shock physics and dynamic compression experiments to reliably get velocity information from experiments. In PDV systems, a common method of reducing experimental cost is to use time and frequency multiplexing to increase the number of PDV probes. With time multiplexing, interference between probes is a frequent problem. In this report, we look at using a high-speed optical switch to reduce this interference, including measuring the amount of interference generated to determine if it has the potential to affect experiments and integrating a time multiplexing system into an experiment. We find that, when applied to PDV systems, there is approximately (-23.4 ± 0.9) dB of interference measured in the short time Fourier transform between switch inputs. When an optical switch based time multiplexing system was integrated into a dynamic compression experiment, the system was able to successfully combine the signals from four different PDV probes onto a single optical cable without unacceptable levels of interference in the spectrogram. An optical switch based time multiplexing system appears to be a promising method for reducing the cost of fielding larger numbers of PDV probes in an experiment.

47 OTHER INSTRUMENTATION↗

Quantitative multiplex detection of biomarkers on a waveguide-based biosensor using quantum dots

The quantitative, simultaneous detection of multiple biomarkers with high sensitivity and specificity is critical for biomedical diagnostics, drug discovery and biomarker characterization [Wilson 2006, Tok 2006, Straub 2005, Joos 2002, Jani 2000]. Detection systems relying on optical signal transduction are, in general, advantageous because they are fast, portable, inexpensive, sensitive, and have the potential for multiplex detection of analytes of interest. However, conventional immunoassays for the detection of biomarkers, such as the Enzyme Linked Immunosorbant Assays (ELISAs) are semi-quantitative, time consuming and insensitive. ELISA assays are also limited by high non-specific binding, especially when used with complex biological samples such as serum and urine (REF). Organic fluorophores that are commonly used in such applications lack photostability and possess a narrow Stoke's shift that makes simultaneous detection of multiple fluorophores with a single excitation source difficult, thereby restricting their use in multiplex assays. The above limitations with traditional assay platforms have resulted in the increased use of nanotechnology-based tools and techniques in the fields of medical imaging [ref], targeted drug delivery [Caruthers 2007, Liu 2007], and sensing [ref]. One such area of increasing interest is the use of semiconductor quantum dots (QDs) for biomedical research and diagnostics [Gao and Cui 2004, Voura 2004, Michalet 2005, Chan 2002, Jaiswal 2004, Gao 2005, Medintz 2005, So 2006 2006, Wu 2003]. Compared to organic dyes, QDs provide several advantages for use in immunoassay platforms, including broad absorption bands with high extinction coefficients, narrow and symmetric emission bands with high quantum yields, high photostablility, and a large Stokes shift [Michalet 2005, Gu 2002]. These features prompted the use of QDs as probes in biodetection [Michalet 2005, Medintz 2005]. For example, Jaiswal et al. reported long term multiple color imaging of live cells using QD-bioconjugates [Jaiswal 2003]. Gao [Gao 2004] and So [So 2006] have used QDs as probes for in-vivo cancer targeting and imaging. Medintz et al. reported self-assembled QD-based biosensors for detection of analytes based on energy transfer [Medintz 2003]. Others have developed an approach for multiplex optical encoding of biomolecules using QDs [Han 2001]. Immunoassays have also benefited from the advantages of QDs. Recently, dihydrolipoic acid (DHLA) capped-QDs have been attached to antibodies and used as fluorescence reporters in plate-based multiplex immunoassays [Goodman 2004]. However, DHLA-QDs are associated with low quantum efficiency and are unstable at neutral pH. These problems limit the application of this technology to the sensitive detection of biomolecules, especially in complex biological samples. Thus, the development of a rapid, sensitive, quantitative, and specific multiplex platform for the detection of biomarkers in difficult samples remains an elusive target. The goal stated above has applications in many fields including medical diagnostics, biological research, and threat reduction. The current decade alone has seen the development of a need to rapidly and accurately detect potential biological warfare agents. For example, current methods for the detection of anthrax are grossly inadequate for a variety of reasons including long incubation time (5 days from time of exposure to onset of symptoms) and non-specific ('flu-like') symptoms. When five employees of the United State Senate were exposed to B. anthracis in the mail (2001), only one patient had a confirmed diagnosis before death. Since then, sandwich immunoassays using both colorimetric and fluorescence detectors have been developed for key components of the anthrax lethal toxin, namely protective antigen (PA), lethal factor (LF), and the edema factor [Mourez 2001]. While these platforms were successful in assays against anthrax toxins, the sensitivity was poor. Furthermore, no single platform exists for the simultaneous and quantitative detection of multiple components of the B. anthracis toxin. Addressing multiple biomarkers at the same time will increase confidence in a positive result, and may lead to application in the simultaneous detection of anthrax and other biowarfare agents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Review on Quantitative Multiplexed Proteomics

Over the last few decades, mass spectrometry-based proteomics has become an increasingly powerful tool that is now able to routinely detect and quantify thousands of proteins. A major advance for global protein quantification was the introduction of isobaric tags, which in a single experiment enable the global quantification of proteins across multiple samples. We refer to these methods as multiplexed proteomics. We discuss the principles, advantages, and drawbacks of various multiplexed proteomics techniques, and compare them to alternative approaches. We discuss how the emerging combination of multiplexing with targeted proteomics might enable the reliable and high-quality quantification of very low-abundance proteins across multiple conditions. We suggest that fusing multiplexed proteomics with data-independent acquisition approaches might enable the comparison of hundreds of different samples without missing values while maintaining the superb measurement precision and accuracy obtainable with isobaric tag quantification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transparent Dielectric Metasurfaces for Spatial Mode Multiplexing

Expanding the use of physical degrees of freedom to employ spatial multiplexing of data in optical communication is considered to be the most disruptive and effective solution for meeting the capacity demand of the growing information traffic. Development of space division–multiplexing methods stimulated research on spatial encoding, detection, and processing of data, attracting interest from various fields of science. Here a passive all–dielectric metasurface with near–unity transmission is demonstrated that engineers spatial mode profiles, potentially of an arbitrary complexity. The broadband response of the metasurface covers all S, C, and L bands of fiber communications. Unlike conventional phase plates, the metasurface allows for both phase and polarization conversion, providing full flexibility for the mode engineering. The dielectric metasurface is employed for mode multiplexing in a free–space optical communication system with an extinction ratio in excess of 20 dB over the whole C–band with negligible penalty even for 100 Gb s –1 data transmission. Furthermore, these results merge two seemingly different fields, optical communication and metamaterials , and they suggest a novel approach for an ultimate miniaturization of mode multiplexers and advanced LiFi technologies.

97 MATHEMATICS AND COMPUTING↗

Results and Limits of Time-Division Multiplexing for the BICEP Array High-Frequency Receivers

Time-division multiplexing is the readout architecture of choice for many ground and space experiments, as it is a very mature technology with proven outstanding low-frequency noise stability, which represents a central challenge in multiplexing. Once fully populated, each of the two BICEP Array high-frequency receivers, observing at 150 GHz and 220/270 GHz, will have 7776 TES detectors tiled on the focal plane. The constraints set by these two receivers required a redesign of the warm readout electronics. The new version of the standard multichannel electronics, developed and built at the University of British Columbia, is presented here for the first time. BICEP Array operates time-division multiplexing readout technology to the limits of its capabilities in terms of multiplexing rate, noise and cross talk, and applies them in rigorously demanding scientific application requiring extreme noise performance and systematic error control. Finally, future experiments like CMB-S4 plan to use TES bolometers with time-division/SQUID-based readout for an even larger number of detectors.

47 OTHER INSTRUMENTATION↗

NaroNet: Discovery of tumor microenvironment elements from highly multiplexed images

Understanding the spatial interactions between the elements of the tumor microenvironment -i.e. tumor cells. fibroblasts, immune cells- and how these interactions relate to the diagnosis or prognosis of a tumor is one of the goals of computational pathology. We present NaroNet, a deep learning framework that models the multi-scale tumor microenvironment from multiplex-stained cancer tissue images and provides patient-level interpretable predictions using a seamless end-to-end learning pipeline. Trained only with multiplex-stained tissue images and their corresponding patient-level clinical labels, NaroNet unsupervisedly learns which cell phenotypes, cell neighborhoods, and neighborhood interactions have the highest influence to predict the correct label. To this end, NaroNet incorporates several novel and state-of-the-art deep learning techniques, such as patch-level contrastive learning, multi-level graph embeddings, a novel max-sum pooling operation, or a metric that quantifies the relevance that each microenvironment element has in the individual predictions. We validate NaroNet using synthetic data simulating multiplex-immunostained images where a patient label is artificially associated to the -adjustable- probabilistic incidence of different microenvironment elements. We then apply our model to two sets of images of human cancer tissues: 336 seven-color multiplex-immunostained images from 12 high-grade endometrial cancer patients; and 382 35-plex mass cytometry images from 215 breast cancer patients. In both synthetic and real datasets, NaroNet provides outstanding predictions of relevant clinical information while associating those predictions to the presence of specific microenvironment elements.

60 APPLIED LIFE SCIENCES↗