Search NASA⌕ Search

SEARCH · Search NASA

Results for “NBL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Results from an Investigation into Extra-Vehicular Activity (EVA) Training Related Shoulder Injuries

The number and complexity of extravehicular activities (EVAs) required for the completion and maintenance of the International Space Station (ISS) is unprecedented. The training required to successfully complete this magnitude of space walks presents a real risk of overuse musculoskeletal injuries to the EVA crew population. There was mounting evidence raised by crewmembers, trainers, and physicians at the Johnson Space Center (JSC) between 1999 and 2002 that suggested a link between training in the Neutral - Buoyancy Lab (NBL) and the several reported cases of shoulder injuries. The short- and long-term health consequences of shoulder injury to astronauts in training as well as the potential mission impact associated with surgical intervention to assigned EVA crew point to this as a critical problem that must be mitigated. Thus, a multi-directorate tiger team was formed in December of 2002 led by the EVA Office and Astronaut Office at the JSC. The primary objectives of this Tiger Team were to evaluate the prevalence of these injuries and substantiate the relationship to training in the NBL with the crew person operating in the EVA Mobility Unit (EMU). Between December 2002 and June of 2003 the team collected data, surveyed crewmembers, consulted with a variety of physicians, and performed tests. The results of this effort were combined with the vast knowledge and experience of the Tiger Team members to formulate several findings and over fifty recommendations. This paper summarizes those findings and recommendations as well as the process by which these were determined. The Tiger Team concluded that training in the NBL was directly linked to several major and minor shoulder injuries that had occurred. With the assistance of JSC flight surgeons, outside consultants, and the lead crewmember/physician on the team, the mechanisms of injury were determined. These mechanisms were then linked to specific aspects of the hardware design, operational techniques, and the training environment. During the 1999 to 2003 time frame many variables converged to make it impossible to determine with any accuracy which one or two root causes were primarily involved. Therefore a broad range of recommendations was established to prevent future injury to crewmembers training in the NBL in the near term. Many of these recommendations are lessons learned that are essentially timeless and therefore should be passed on to future EVA endeavors to ensure that hardware designs and operational techniques utilized in the future consider the demands of training on the human body here on earth.

Johnson, Brian J.↗

Shoulder Injuries in US Astronauts Related to EVA Suit Design

Introduction: For every one hour spent performing extravehicular activity (EVA) in space, astronauts in the US space program spend approximately six to ten hours training in the EVA spacesuit at NASA-Johnson Space Center's Neutral Buoyancy Lab (NBL). In 1997, NASA introduced the planar hard upper torso (HUT) EVA spacesuit which subsequently replaced the existing pivoted HUT. An extra joint in the pivoted shoulder allows increased mobility but also increased complexity. Over the next decade a number of astronauts developed shoulder problems requiring surgical intervention, many of whom performed EVA training in the NBL. This study investigated whether changing HUT designs led to shoulder injuries requiring surgical repair. Methods: US astronaut EVA training data and spacesuit design employed were analyzed from the NBL data. Shoulder surgery data was acquired from the medical record database, and causal mechanisms were obtained from personal interviews Analysis of the individual HUT designs was performed as it related to normal shoulder biomechanics. Results: To date, 23 US astronauts have required 25 shoulder surgeries. Approximately 48% (11/23) directly attributed their injury to training in the planar HUT, whereas none attributed their injury to training in the pivoted HUT. The planar HUT design limits shoulder abduction to 90 degrees compared to approximately 120 degrees in the pivoted HUT. The planar HUT also forces the shoulder into a forward flexed position requiring active retraction and extension to increase abduction beyond 90 degrees. Discussion: Multiple factors are associated with mechanisms leading to shoulder injury requiring surgical repair. Limitations to normal shoulder mechanics, suit fit, donning/doffing, body position, pre-existing injury, tool weight and configuration, age, in-suit activity, and HUT design have all been identified as potential sources of injury. Conclusion: Crewmembers with pre-existing or current shoulder injuries or certain anthropometric body types should conduct NBL EVA training in the pivoted HUT.

Scheuring, R. A.↗

Evaluation of Aerobic Standards for Lunar Surface Extravehicular Activities

Introduction: As NASA prepares to return to the Moon, astronauts will need to be physically primed to successfully execute Extravehicular Activities (EVA) on the Lunar surface. Compared to past Apollo missions, Artemis missions will include EVAs of increased physical demand, frequency, intensity, and duration, thus requiring adequate fitness to successfully and safely complete mission objectives. The physical demand associated with partial gravity (g) EVAs on the Moon is expected to be greater compared to microgravity EVAs based on initial workload estimation. Currently, aerobic fitness standards for partial g EVAs are not well supported by high-fidelity data and require further research for establishing standards to protect crew health and performance during Lunar surface missions. Therefore, the aim of this investigation is to characterize metabolic data from Lunar analog simulations and in-flight crew population aerobic capacity data to validate the current NASA 3001 standard for celestial partial g aerobic fitness (aerobic capacity (VO_2pk) ≥36.5ml/kg/min). Methods: In order to evaluate aerobic fitness requirements for Lunar EVAs, the following were performed: 1) preliminary analysis of long-duration (6 hr) EVA analog simulations in the Neutral Buoyancy Laboratory (NBL) and the Active Response Gravity Offload System (ARGOS) to evaluate expected metabolic rates for 1/6 g EVAs (NBL: n=1 female; ARGOS: n=1 male) and 2) assessment of the current NASA 3001 celestial surface EVA aerobic standard (aerobic capacity (VO_2pk) ≥36.5ml/kg/min) with data from an ISS astronaut population (n=30 male + 13 female) captured before and during space flight (flight day 15). Preliminary Results: Average fractional aerobic capacity during simulated EVAs were 33%±7% VO_2pk and 23.3±7% VO_2pk in the NBL and ARGOS, respectively. This was within a previously predicted 30–40% sustainable work rate. Average metabolic rates for some tasks performed in the NBL, such as traverse (40.4% VO_2pk) and ingress (47.1% VO_2pk) were higher than the predicted sustainable work range. In ARGOS, the tasks with the greatest metabolic rates were object relocation (34.2% VO_2pk) and incapacitated crew rescue (27.0% VO_2pk). Characterization of ISS crewmember aerobic capacity determined that the average preflight VO_2pk was 42.1±5.4 ml/kg/min for females and 37.5±5.4 ml/kg/min for males. At preflight, 21.5% of crewmembers were below the 36.5 ml/kg/min in-mission aerobic standard for celestial surface EVA as outlined in NASA-STD-3001. In-flight, both female and male crewmembers experienced reductions in VO_2pk (11.7% and 10.9%, respectively), such that, during the mission, 62% of crewmembers were below the standard aerobic capacity level for celestial surface EVAs. Conclusions: Our preliminary data suggest that while average metabolic rates for simulated Lunar EVA fall within the 30–40% sustainable work range, task specific metabolic rates exceed this range and may indicate that greater fitness is necessary for more strenuous tasks expected to be performed on the Lunar surface. Additionally, deconditioning due to space flight results in most crewmembers falling below the current celestial partial g EVA standard, which may increase risk to crew health and performance and completing mission objectives for surface missions. Further research is necessary in Artemis-specific analog environments to validate the current NASA-3001 aerobic standard for celestial EVAs. Additionally, work is ongoing to validate the current NASA-3001 strength standard for celestial EVAs.

N.C. Strock↗

Development of Weighout Process and Evaluations for Underwater Partial Gravity EVA Simulations

For the upcoming Artemis lunar missions, astronauts will needto train in a spacesuit where partial gravity can be simulated such as NASA Neutral Buoyancy Lab (NBL). At the NBL, dive weights and foam can be added around the spacesuit to attaina satisfactory center of buoyancy (CB) and center of gravity (CG) location to simulate the lunar gravity (1/6thG) effects. If CG and CB are not co-located properly, incorrect righting moments can be introduced, and both simulation quality and EVA task performance can be impaired. Based on the findings from the initial testingusing xEMU spacesuits, it was observed that the weigh-out method (i.e., determination of the weights and foam quantities and position) needed further development to improve the simulation quality, especially for the subjects who experienced excessive instability. This paper aims to present the on-going effort to improve the weigh-out process for enabling NBL lunar EVA simulations. For this effort, a human-suit model was created to use suit CAD and 3D human body scansto estimate both CB and CG location for each suited subject. NBL weigh-out testing was performed to characterize the effects of CG and CB positioning, in which the 3D human-suit model was used to determine optimal weigh-out combinations of weights and foam. Postural, balance, and subjective feedback were gathered for each weigh-out configuration. The results indicated that, as the CB was shifted higher and the CB and CG located closer to each other, the subject tended to be more stable and their EVA performance improved. A high CB location was then prioritized across 4 additional subjects in both small and large size spacesuits. When compared to the initial xEMU test series, improved performance was observed across all subjects as the CB moved higher and aligned closer to the system CG.

Seyed Pouyan Sabahi↗

Development of Weigh-out Process and Evaluations for Underwater Partial Gravity Simulations

For the upcoming Artemis lunar missions, astronauts will need to train in a spacesuit where partial gravity can be simulated such as the NASA Neutral Buoyancy Lab (NBL). At the NBL, dive weights and foam can be added around the spacesuit to attain a satisfactory center of buoyancy (CB) and center of gravity (CG) location to simulate the lunar gravity (1/6thG) effects. If CG and CB are not co-located properly, incorrect righting moments can be introduced, and both simulation quality and EVA task performance can be impaired. Based on the findings from the initial testing using xEMU spacesuits, it was observed that the weigh-out method (i.e., determination of the weights and foam quantities and position) needed further development to improve the simulation quality, especially for the subjects who experienced excessive instability. This paper aims to present the on-going effort to improve the weigh-out process for enabling NBL lunar EVA simulations. For this effort, a human-suit model was created to use suit CAD and 3D human body scans to estimate both CB and CG location for each suited subject. NBL weigh-out testing was performed to characterize the effects of CG and CB positioning, in which the 3D human-suit model was used to determine optimal weigh-out combinations of weights and foam. Postural, balance, and subjective feedback were gathered for each weigh-out configuration. The results indicated that, as the CB was shifted higher and the CB and CG located closer to each other, the subject tended to be more stable and their EVA performance improved. A high CB location was then prioritized across 4 additional subjects in both small and large size spacesuits. When compared to the initial xEMU test series, improved performance was observed across all subjects as the CB moved higher and aligned closer to the system CG.

Pouyan Sabahi↗

Development of Weigh-out Process and Evaluations for Underwater Partial Gravity Simulations

For the upcoming Artemis lunar missions, astronauts will need to train in a spacesuit where partial gravity can be simulated such as the NASA Neutral Buoyancy Lab (NBL). At the NBL, dive weights and foam can be added around the spacesuit to attain a satisfactory center of buoyancy (CB) and center of gravity (CG) location to simulate the lunar gravity (1/6thG) effects. If CG and CB are not co-located properly, incorrect righting moments can be introduced, and both simulation quality and EVA task performance can be impaired. Based on the findings from the initial testing using xEMU spacesuits, it was observed that the weigh-out method (i.e., determination of the weights and foam quantities and position) needed further development to improve the simulation quality, especially for the subjects who experienced excessive instability. This paper aims to present the on-going effort to improve the weigh-out process for enabling NBL lunar EVA simulations. For this effort, a human-suit model was created to use suit CAD and 3D human body scans to estimate both CB and CG location for each suited subject. NBL weigh-out testing was performed to characterize the effects of CG and CB positioning, in which the 3D human-suit model was used to determine optimal weigh-out combinations of weights and foam. Postural, balance, and subjective feedback were gathered for each weigh-out configuration. The results indicated that, as the CB was shifted higher and the CB and CG located closer to each other, the subject tended to be more stable and their EVA performance improved. A high CB location was then prioritized across 4 additional subjects in both small and large size spacesuits. When compared to the initial xEMU test series, improved performance was observed across all subjects as the CB moved higher and aligned closer to the system CG.

Pouyan Sabahi↗

Development of Weigh-Out Process and Evaluations for Underwater Partial Gravity Simulations

For the upcoming Artemis lunar missions, astronauts will need to train in a spacesuit where partial gravity can be simulated such as the NASA Neutral Buoyancy Lab (NBL). At the NBL, dive weights and foam can be added around the spacesuit to attain a satisfactory center of buoyancy (CB) and center of gravity (CG) location to simulate the lunar gravity (1/6thG) effects. If CG and CB are not co-located properly, incorrect righting moments can be introduced, and both simulation quality and EVA task performance can be impaired. Based on the findings from the initial testing using xEMU spacesuits, it was observed that the weigh-out method (i.e., determination of the weights and foam quantities and position) needed further development to improve the simulation quality, especially for the subjects who experienced excessive instability. This paper aims to present the on-going effort to improve the weigh-out process for enabling NBL lunar EVA simulations. For this effort, a human-suit model was created to use suit CAD and 3D human body scans to estimate both CB and CG location for each suited subject. NBL weigh-out testing was performed to characterize the effects of CG and CB positioning, in which the 3D human-suit model was used to determine optimal weigh-out combinations of weights and foam. Postural, balance, and subjective feedback were gathered for each weigh-out configuration. The results indicated that, as the CB was shifted higher and the CB and CG located closer to each other, the subject tended to be more stable and their EVA performance improved. A high CB location was then prioritized across 4 additional subjects in both small and large size spacesuits. When compared to the initial xEMU test series, improved performance was observed across all subjects as the CB moved higher and aligned closer to the system CG.

Pouyan Sabahi↗

Toward parameterization of the stable boundary layer

Wangara data is used to examine the depth of the nocturnal boundary layer (NBL) and the height to which surface-linked turbulence extends. It is noted that a linearity of virtual temperature profiles has been found to extend up to a significant portion of the NBL, and then diverge where the wind shear rides over the surface-induced turbulence. A series of Richardson numbers are examined for varying degrees of turbulence and the significant cooling region is observed to have greater depth than the depth of the linear relationship layer. A three-layer parameterization of the thermodynamic structure of the NBL is developed so that a system of five equations must be solved when the wind velocity profile and the temperature at the surface are known. A correlation between the bulk Richardson number and the depth of the linear layer was found to be 0.89.

Wetzel, P. J.↗

A Glimpse from the Inside of a Space Suit: What Is It Really Like to Train for an EVA?

The beauty of the view from the office of a spacewalking astronaut gives the impression of simplicity, but few beyond the astronauts, and those who train them, know what it really takes to get there. Extravehicular Activity (EVA) training is an intense process that utilizes NASA's Neutral Buoyancy Laboratory (NBL) to develop a very specific skill set needed to safely construct and maintain the orbiting International Space Station. To qualify for flight assignments, astronauts must demonstrate the ability to work safely and efficiently in the physically demanding environment of the spacesuit, possess an acute ability to resolve unforeseen problems, and implement proper tool protocols to ensure no tools will be lost in space. Through the insights and the lessons learned by actual EVA astronauts and EVA instructors, this paper twill take you on a journey through an astronaut's earliest experiences working in the spacesuit. termed the Extravehicular Mobility Unit (EMU), in the underwater training environment of the NBL. This work details an actual Suit Qualification NBL training event, outlines the numerous challenges the astronauts face throughout their initial training, and the various ways they adapt their own abilities to overcome them. The goal of this paper is to give everyone a small glimpse into what it is really like to work in a spacesuit.

Gast, Matthew A.↗

Shallow Water Diving - The NASA Experience

This slide presentation reviews some of the problems and solutions that personnel have experienced during sessions in the Neutral Bu0yancy Lab (NBL). It reviews the standard dive that occurs at the NBL, Boyles and Henry's laws as they relate to the effects of diving. It then reviews in depth some of the major adverse physiologic events that happen during a diving session: Ear and Sinus Barotrauma, Decompression Sickness, (DCS), Pulmonary Barotrauma (i.e., Arterial Gas Embolism (AGE). Mediastinal Emphysema, Subcutaneous Emphysema, and Pneumothorax) Oxygen Toxicity and Hypothermia. It includes information about the pulmonary function in NBL divers. Also included is recommendations about flying after diving.

Fitzpatrick, Daniel↗

EVA Development and Verification Testing at NASA's Neutral Buoyancy Laboratory

As an early step in preparing for future EVAs, astronauts perform neutral buoyancy testing to develop and verify EVA hardware and operations. To date, neutral buoyancy demonstrations at NASA JSC’s Sonny Carter Training Facility have primarily evaluated assembly and maintenance tasks associated with several elements of the ISS. With the retirement of the Space Shuttle, completion of ISS assembly, and introduction of commercial participants for human transportation into space, evaluations at the NBL will take on a new focus. In this session, Juniper Jairala briefly discussed the design of the NBL and, in more detail, described the requirements and process for performing a neutral buoyancy test, including typical hardware and support equipment requirements, personnel and administrative resource requirements, examples of ISS systems and operations that are evaluated, and typical operational objectives that are evaluated. Robert Durkin discussed the new and potential types of uses for the NBL, including those by non-NASA external customers.

Juniper Jairala↗

EVA Development and Verification Testing at NASA's Neutral Buoyancy Laboratory

As an early step in preparing for future EVAs, astronauts perform neutral buoyancy testing to develop and verify EVA hardware and operations. To date, neutral buoyancy demonstrations at NASA JSC's Sonny Carter Training Facility have primarily evaluated assembly and maintenance tasks associated with several elements of the ISS. With the retirement of the Space Shuttle, completion of ISS assembly, and introduction of commercial participants for human transportation into space, evaluations at the NBL will take on a new focus. In this session, Juniper Jairala briefly discussed the design of the NBL and, in more detail, described the requirements and process for performing a neutral buoyancy test, including typical hardware and support equipment requirements, personnel and administrative resource requirements, examples of ISS systems and operations that are evaluated, and typical operational objectives that are evaluated. Robert Durkin discussed the new and potential types of uses for the NBL, including those by non-NASA external customers.

Juniper Jairala↗

Compiling a Comprehensive EVA Training Dataset for NASA Astronauts

Training for a spacewalk or extravehicular activity (EVA) is considered a hazardous duty for NASA astronauts. This places astronauts at risk for decompression sickness as well as various musculoskeletal disorders from working in the spacesuit. As a result, the operational and research communities over the years have requested access to EVA training data to supplement their studies. The purpose of this paper is to document the comprehensive EVA training data set that was compiled from multiple sources by the Lifetime Surveillance of Astronaut Health (LSAH) epidemiologists to investigate musculoskeletal injuries. The EVA training dataset does not contain any medical data, rather it only documents when EVA training was performed, by whom and other details about the session. The first activities practicing EVA maneuvers in water were performed at the Neutral Buoyancy Simulator (NBS) at the Marshall Spaceflight Center in Huntsville, Alabama. This facility opened in 1967 and was used for EVA training until the early Space Shuttle program days. Although several photographs show astronauts performing EVA training in the NBS, records detailing who performed the training and the frequency of training are unavailable. Paper training records were stored within the NBS after it was designated as a National Historic Landmark in 1985 and closed in 1997, but significant resources would be needed to identify and secure these records, and at this time LSAH has not pursued acquisition of these early training records. Training in the NBS decreased when the Johnson Space Center in Houston, Texas, opened the Weightless Environment Training Facility (WETF) in 1980. Early training records from the WETF consist of 11 hand-written dive logbooks compiled by individual workers that were digitized at the request of LSAH. The WETF was integral in the training for Space Shuttle EVAs until its closure in 1998. The Neutral Buoyancy Laboratory (NBL) at the Sonny Carter Training Facility near JSC opened in March 1997 and is the current site for US EVA training. Other space agencies also have used water to simulate weightlessness and train for EVAs. Russia has a training facility similar to the NBL named the Hydro Lab. The Hydro Lab began operations at the Gagarin Cosmonaut Training Center (GCTC) in 1980 and has been used extensively to the present. Although a majority of training in the Hydro Lab uses the Russian Orlan suit, a small number of sessions have been conducted using a NASA suit. The Japanese Weightlessness Environment Test System (WETS) went into service at the Tsukuba Space Center in 1997 but was closed in 2011 due to extensive earthquake damage. Several sessions were performed using a NASA suit, but these sessions were short and considered "development" runs. LSAH has assembled records from the WETF, NBL and Hydro Lab. Recording of the EVA training data has changed considerably from 1967 to present. The goal of early record keeping was to track use of hardware components, and the person involved was treated as a suited operator, not as a focus of interest. Records from the past two decades are fairly precise with the person, date, suit type and size noted. On occasion the length of the session was listed, but this data is not included on all records. Records were merged from data sources and extensive cleaning of the records was required since the multiple sources frequently overlapped and duplicated records. To date the LSAH EVA training dataset includes over 12,500 EVA training sessions performed by NASA astronauts since 1981. The following variables are included for most records: Name, Sex, Event date, Event name, HUT type, HUT size, Facility, and Estimated run time. For a smaller subset of records, the following variables are available: Actual run time, Time inverted, and the suit components Waist bearing type, Shoulder harness, Shoulder pads, and Teflon inserts. The LSAH dataset is currently the most complete resource for data regarding EVA training sessions performed by NASA astronauts. However, it is not 100 percent complete since the WETS (Japan) and NBS (Marshall) training facility data were not included. This dataset has been compiled by LSAH to study the relationship of EVA training to musculoskeletal injuries but has many other non-medical applications. This dataset can be provided to other groups in order to respond to program and research questions with appropriate board approvals.

Laughlin, M. S.↗

NASA's Advanced Extra-Vehicular Activity Space Suit Pressure Garment 2018 Status and Development Plan

This paper presents both near-term and long-term NASA Advanced Extra-vehicular Activity (EVA) Pressure Garment development efforts. The near-term plan discusses the development of pressure garment components for the first design iteration of the International Space Station exploration space suit demonstration configuration, termed the xEMU Demo. The xEMU Demo effort is targeting a 2023-2025 flight demonstration timeframe. The Fiscal Year 2018 (FY18) tasks focus on either the initiation or maturation of component design, depending on the state of development of the components, and the assembly of a suit configuration, termed Z-2.5, that will be used to evaluate changes to the upper torso geometry in a Neutral Buoyancy Laboratory (NBL) test series. The geometry changes, which are being driven by the need to reduce the front-to-back dimension of the advanced extravehicular mobility unit, diverge from a proven shape, such as that of the Mark III Space Suit Technology Demonstrator. The 2018 efforts culminate in the Z-2.5 NBL test. The lessons learned from the Z-2.5 NBL test will inform the xEMU Demo design as the effort moves toward design verification testing and preliminary and critical design reviews. The long-term development plan looks to surface exploration and operations. Technology and knowledge gaps exist between the xEMU Demo configuration; a lunar surface capability, xEMU; and Mars surface suit, mEMU. The development plan takes into account both the priority and the anticipated development duration for each particular technology. The long-term development plan will be updated as risks are mitigated and gaps are closed, but its overarching structure will remain intact.

space suit↗

NASA Advanced Space Suit Pressure Garment System Status and Development Priorities 2019

This paper discusses the current focus of NASA's Advanced Space Suit Pressure Garment Technology Development team's efforts, the status of that work, and a summary of longer term technology development priorities and activities. The Exploration Extra-vehicular Activity Unit (xEMU) project's International Space Station Demonstration Suit (xEMU Demo) project continues to be the team's primary customer and effort. In 2018 the team was engaged in addressing hardware design changes identified in the Z-2 pressure garment prototype Neutral Buoyancy Laboratory (NBL) test results. These changes will be discussed. Additionally components whose first iterations were produced in 2018 will be discussed. A full pressure garment prototype, termed Z-2.5, was assembled that is composed of updated and first prototype iteration hardware. Z-2.5 NBL testing, performed from October 2018 through April 2019 will inform final design iterations in preparation for the xEMU Demo preliminary design review planned to occur in the third quarter of government fiscal year 2019. A primary objective of the Z-2.5 NBL testing is to validate changes made to the hard upper torso geometry, which depart from the planetary walking suit upper torso geometry that has been used over the last 30 years. The team continues to work technology development, with GFY2018 work being used to supplement and feed the gaps left by the scope defined for the xEMU Demo. Specifically, a Phase IIx Small Business Innovative Research Grant to mature durable bearings that are compatible with a dust environment and a grant funded by the Science Technology Mission Directorate, Lightweight and Robust Exploration Space Suit (LARESS) project, to mature planetary impact requirements and hardware will be described. Finally, a brief review of longer-term pressure garment challenges and technology gaps will be presented to provide an understanding of the advanced pressure garment team's technology investment priorities and needs.

Ross, Amy↗

Shoulder Postures in EVA Training in Reduced Gravity Analogues

Shoulder Postures in EVA Training in Reduced Gravity Analogues K. Guhl1, L. Vu2, H. Kim3, S. Rajulu4 1KBR Inc., Houston, TX, 2Aegis Aerospace Inc., Houston, TX, 3Leidos Innovations, Houston, TX, 4NASA Johnson Space Center, Houston, TX. During extravehicular activities (EVAs) and EVA training in both the Neutral Buoyancy Laboratory (NBL) and at the Active Response Gravity Offload System (ARGOS), crewmembers perform a variety of hand-intensive tasks with frequent arm/shoulder repositioning while wearing a pressurized spacesuit. As a result, crewmembers may experience ergonomic stressors such as awkward shoulder postures. The ergonomic shoulder risk is also compounded by limited or restricted shoulder mobility of the spacesuit, extreme work positions such as overhead tasks, and tasks with heavy tools and repetitive motions. Prolonged or frequent shoulder elevation and overhead work, in particular, can lead to excessive stresses and musculoskeletal injuries of the shoulder joints. Future EVA missions, specifically lunar surface EVAs, will also be longer in duration and thus increase the exposure to awkward shoulder postures. In this study, we aimed to assess the ergonomic risk of awkward shoulder postures in simulated lunar surface EVAs by quantifying when and how long the arms are raised above the chest level. We assessed video recordings of pilot lunar EVA simulations (3 lunar trials each in the NBL and at ARGOS and 2 microgravity EVA trials in the NBL). These runs consisted of both training and engineering test objectives. Actual demands for shoulder use varied for different EVA types and analogues, but many EVA runs have common tasks and require similar motion components. A video observation and event logging software was used to document the duration and occurrence of the subject’s arms being raised throughout the video recordings of each EVA run. An arm raised instance was classified as the arm being at 90 degrees or above with relation to gravity for lunar EVA training events and with relation to the body for microgravity EVA training events. Such events included EVA hardware maintenance or heavy geology sampling tool operations. Events where the arm load was partially supported by external objects, like climbing a ladder or leaning against a surface were separately identified and excluded. Statistical analysis was performed to summarize the timing, frequency, and durations of the arm raise events and compared across the different EVA tasks and analogue types. Preliminary observations indicated that the total duration and number of arm raised instances were surprisingly smaller for lunar surface EVA training as compared to microgravity EVA training. The observed difference may be attributed to differing task demands and unique environmental characteristics found in lunar EVAs in comparison to microgravity EVAs. A detailed statistical analysis will be performed between lunar surface EVA training events and microgravity EVA training events in the final submission. Overall, this analysis is expected to provide insight into how ergonomic recommendations can be refined for lunar EVA training with pressurized suits. It may also inform task design and influence suit padding design to better protect crewmembers during future lunar training.

Kaitlyn Lea Guhl↗

Preliminary Insights Into the Feasibility of Determining the Purification Date of Enriched Uranium by Direct Measurement of the 230 Th/ 234 U Ratio Using an All-Faraday Detector Configuration on the Neoma MC-ICP-MS

Rationale: Mass spectrometric measurement of the 230 Th/ 234 U ratio to calculate the purification age of enriched uranium is typically conducted via a combination of ion counters and faraday detectors, thus requiring an inter-detector calibration scheme. Here, our aim is to understand whether the pursuit of a simplified measurement scheme involving only faraday detectors is feasible. Methods: We investigate the possibility of determining U-Th model ages for two enriched uranium standards (NBL U630 and U850) by direct measurement of the 230 Th/ 234 U ratio (without chromatographic separation or isotope dilution) on a ThermoFisher Scientific Neoma MC-ICP-MS utilizing both solution and laser ablation (LA)-based sampling techniques and an all-faraday detector configuration. Results: For the solution mode analyses conducted on aliquots containing sub μg/mL total U, we produce composite average 230 Th/ 234 U model dates of May 19, 1988 (± 351 days), and March 26, 1961 (± 2.5 years) using the directly measured 230 Th/ 234 U ratios for the NBL U630 and U850 uranium standards, which have certified purification dates of June 6, 1988 (± 190 days), and December 31, 1957 (± 36.5 days), respectively. The ages produced by LA-based sampling of dried residues of the same standards deposited onto cotton TexWipes are less accurate and of poorer precision (June 23, 2004 ± 8.7 years for U630 and December 21, 1965 ± 7.9 years for U850) but still yield meaningful information in regards to the purification date. Conclusions: We believe that further refinement of the all faraday detector measurement approach to include development of a more robust Th/U relative sensitivity factor determination, signal cutoff selection, and data processing protocols will allow for this approach to be confidently applied to enriched uranium materials with unknown purification histories. Potential advantages of the method include the reduced sample handling and infrastructure requirements as well as the ability to simultaneously generate a broad picture of the uranium isotopic composition in tandem with the U-Th age determination.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Plutonium isotope ratio measurements by total evaporation-thermal ionization mass spectrometry (TE-TIMS): an evaluation of uncertainties using traceable standards from the New Brunswick Laboratory

The accuracy and precision of isotope amount ratio measurements using thermal ionization mass spectrometry (TIMS) instrumentation are described, and the measurement of Pu materials is emphasized. The mass fractionation observed for Am, Ga, Pu, and U for isotope amount ratio measurements using the total evaporation (TE) technique is compared with theoretical estimates to demonstrate the advantage of the TE methodology and to investigate systematic biases in the major isotope amount ratios of U and Pu certified reference material (CRM) standards from the U.S. provider of CRMs. The quality of the Pu isotopic data generated by TIMS instruments in an analytical laboratory is demonstrated by the application of the double ratio technique to estimate the 241 Pu half-life. Analytical data on traceable Pu CRMs from the New Brunswick Laboratory (NBL), generated as part of routine measurements supporting various programs, are used for this half-life estimation. Although the 241 Pu abundances in CRMs of 136, 137, 138, and 126-A are approximately 200–2000× smaller than those in the 241 Pu material used in the previous Institute for Reference Materials and Measurements (IRMM) evaluation of the 241 Pu half-life, the half-life value estimated in this work shows excellent agreement with the currently accepted value from the IRMM. This agreement also demonstrates the pedigree of the Pu isotopic standards from the NBL and the quality of the isotope amount ratio measurements using TIMS instrumentation. For both the major and minor Pu isotope amount ratios, this report describes the relative importance of the factors affecting the uncertainty of TIMS measurements, which are considered the gold standard in isotope ratio measurements (LA-UR-24-29199).

07 ISOTOPE AND RADIATION SOURCES↗