Search NASA⌕ Search

SEARCH · Search NASA

Results for “NEUTRAL PARTICLE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

X-ray and energetic neutral particle emission from Saturn's magnetosphere

A description is presented of observations of the Voyager 1 spacecraft obtained a few days before encounter of the Saturn magnetosphere in November 1980. As Voyager 1 has no special experiment onboard for X-ray and neutral particle detection, the sensitivity and directional measurements of the low energy charged particle (LECP) analyzer is used to identify the neutral radiation above the charged particle background. The LECP telescope uses a silicon detector of 96.6 micrometers thickness and 0.08 sq cm area to accumulate counts in eight separate sectors near the ecliptic plane. The existence of radiation above the detector background emanating from the vicinity of Saturn, upstream from the bow shock is shown. The excess counts are most plausibly attributed to neutral radiation, that is, X rays and/or neutral energetic particles. However, in connection with quantitative considerations the observed excess counts are probably not due to X-rays. It is concluded that charge exchange of energetic ions with satellite tori is an important loss mechanism at Saturn as well as at Jupiter.

Kirsch, E.↗

Machine Learning Approach to Modeling of Neutral Particles Transport in Plasma

A propagator‐based approach is investigated for Monte‐Carlo (MC) modeling of neutral particle transport in fusion boundary plasmas. The propagator is based on a Green's function for the neutral kinetic equation, which depends on the plasma profiles. A neural network (NN)‐based model for the propagator provides a fast and accurate solution for the neutral distribution function in plasma. Preliminary results from a small 1D test problem look encouraging. The proposed approach, a propagator‐based NN model for neutral transport in plasma, has potential for generalization to higher dimensions and efficient coupling with plasma models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation of the imaging neutral particle analyzer in nearly MHD quiescent plasmas using injected beam ions on DIII-D

The imaging neutral particle analyzer (INPA) is a scintillator-based diagnostic that provides energy and radially resolved measurements of confined fast ions. To verify operation, understanding, and modeling of the diagnostic performance, distributions of deuterium beam ions in low density, nearly MHD-quiescent plasmas are measured on the DIII-D tokamak using the INPA. Here, the distribution is altered by changing the pitch-angle scattering rate with electron cyclotron heating (ECH). Experimental images are mostly reproduced with simulation of core fast ions charge exchanging with injected beam and edge cold neutrals in classical cases. Image comparisons between the experiment and simulation show agreement with less than 25% discrepancies near the beam injection energy of 50 keV. Other strong passive signals, observed in a localized region on the image, are suggested to come from charge exchange between cold neutrals and fast ions around the plasma boundary.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Guiding center model to interpret neutral particle analyzer results

The theoretical model is discussed, which accounts for drift and cyclotron components of ion motion in a partially ionized plasma. Density and velocity distributions are systematically precribed. The flux into the neutral particle analyzer (NPA) from this plasma is determined by summing over all charge exchange neutrals in phase space which are directed into apertures. Especially detailed data, obtained by sweeping the line of sight of the apertures across the plasma of the NASA Lewis HIP-1 burnout device, are presented. Selection of randomized cyclotron velocity distributions about mean azimuthal drift yield energy distributions which compared well with experiment. Use of data obtained with a bending magnet on the NPA showed that separation between energy distribution curves of various mass species correlate well with a drift divided by mean cyclotron energy parameter of the theory. Use of the guiding center model in conjunction with NPA scans across the plasma aid in estimates of ion density and E field variation with plasma radius.

Englert, G. W.↗

Interpretation of neutral particle analyzer measurements on plasmas having azimuthal drift

The theoretical model accounts for drift and cyclotron components of ion motion in a partially ionized plasma. Density and velocity distributions are systematically prescribed. The flux into the neutral particle analyzer (NPA) from this plasma is determined by summing over all charge exchange neutrals in phase space which are directed into apertures. Calculation of the process is continued through the NPA using appropriate cross section data to obtain analyzer output distributions. Theoretical results were compared with NPA measurements on four plasma heating devices having radial electric, E, and axial magnetic, B, fields. Drift velocity, in the azimuthal direction is identified with E/B. Selection of randomized cyclotron velocity distributions about mean azimuthal drift yield energy distributions which compare well with experiment.

Englert, G. W.↗

Mass analysis of neutral particles and ions released during electrical breakdowns on spacecraft surfaces

A specialized spectrometer was designed and developed to measure the mass and velocity distributions of neutral particles (molecules and molecular clusters) released from metal-backed Teflon and Kapton films. Promising results were obtained with an insulation breakdown initiation system based on a moveable contact touching the insulated surfaces. A variable energy, high voltage pulse is applied to the contact. The resulting surface damage sites can be made similar in size and shape to those produced by a high voltage electron beam system operating at similar discharge energies. The point discharge apparatus was used for final development of several high speed recording systems and for measurements of the composition of the materials given off by the discharge. Results with this apparatus show evolution of large amounts of fluorocarbon fragments from discharge through Teflon FEP, while discharges through Kapton produce mainly very light hydrocarbon fragments at masses below about 80 a.m.u.

Kendall, B. R. F.↗

Upgrade and characterization of the fast-channels of Imaging Neutral Particle Analyzers in the DIII-D tokamak

This publication presents the characterization of the recently upgraded fast (MHz) channels of the DIII-D Imaging Neutral Particle Analyzers. The new system allows for a phase space resolution of < 10 keV and < 10 cm. The main source of noise is due to the background radiation (neutrons and gammas) present in the diagnostic lab during experiments, which can hit the photomultipliers and generate large spikes in signal. Good linear correlations (r 2 > 0.9) are found between the average rate of noise spikes in the fast channels and the average neutron rate. Additional noise is caused by the scintillation of the optical fibers used to guide the signal to the acquisition system, which is induced by neutron and gamma impacts. A correlation factor r 2 > 0.6 between the baseline noise caused by this scintillation and the signals in the neutron diagnostic was found. Possible mitigation strategies, such as the use of shielding and filters, are discussed. These allow to reduce the noise spike rate by an order of magnitude and the noise baseline by a factor 4. Despite the noise, it is shown that the upgraded fast channels provide enough signal-to-noise ratio to observe coherent fluctuations of the energetic particle population.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Search for light long-lived neutral particles that decay to collimated pairs of leptons or light hadrons in $pp$ collisions at $\sqrt{s}$ = 13 TeV with the ATLAS detector

A search for light long-lived neutral particles with masses in the O(MeV–GeV) range is presented. The analysis targets the production of long-lived dark photons in the decay of a Higgs boson produced via gluon–gluon fusion or in association with a W boson. Events that contain displaced collimated Standard Model fermions reconstructed in the calorimeter or muon spectrometer are selected in 139 fb -1 of $\sqrt{s}$ = 13 TeV $pp$ collision data collected by the ATLAS detector at the LHC. Background estimates for contributions from Standard Model processes and instrumental effects are extracted from data. The observed event yields are consistent with the expected background. Exclusion limits are reported on the production cross-section times branching fraction as a function of the mean proper decay length cτ of the dark photon, or as a function of the dark-photon mass and kinetic mixing parameter that quantifies the coupling between the Standard Model and potential hidden (dark) sectors. A Higgs boson branching fraction above 1% is excluded at 95% CL for a Higgs boson decaying into two dark photons for dark-photon mean proper decay lengths between 10 mm and 250 mm and dark photons with masses between 0.4 GeV and 2 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scintillating crystals for the Neutral Particle Spectrometer in Hall C at JLab

This report discusses the quality and performance of currently available PbWO crystals of relevance to high-resolution electromagnetic calorimetry, e.g. detectors for the Neutral Particle Spectrometer at Jefferson Lab or those planned for the Electron–Ion Collider. Since the construction of the Compact Muon Solenoid (CMS) at the Large Hadron Collider (LHC) and early PANDA (The antiProton ANnihilations at DArmstadt) electromagnetic calorimeter (ECAL) the worldwide availability of high quality PbWO 4 production has changed dramatically. We report on our studies of crystal samples from SICCAS/China and CRYTUR/Czech Republic that were produced between 2014 and 2019.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for light neutral particles decaying promptly into collimated pairs of electrons or muons in pp collisions at $\sqrt{s}$ = 13 TeV with the ATLAS detector

A search for a dark photon, a new light neutral particle, which decays promptly into collimated pairs of electrons or muons is presented. The search targets dark photons resulting from the exotic decay of the Standard Model Higgs boson, assuming its production via the dominant gluon-gluon fusion mode. The analysis is based on 140 fb -1 of data collected with the ATLAS detector at the Large Hadron Collider from proton-proton collisions at a center-of-mass energy of 13 TeV. Events with collimated pairs of electrons or muons are analysed and background contributions are estimated using data-driven techniques. No significant excess in the data above the Standard Model background is observed. Upper limits are set at 95% confidence level on the branching ratio of the Higgs boson decay into dark photons between 0.001% and 5%, depending on the assumed dark photon mass and signal model.

Aad, G. [Aix-Marseille Université] (ORCID:00000002↗

Scalable algorithms for domain decomposition of Monte Carlo neutral particle transport simulations on unstructured mesh

Monte Carlo simulations are the gold standard in particle transport simulations, for shielding and nuclear reactor simulations Full core simulations can require terabytes of memory for tracking pin-resolved (up to 50k pins), nuclide (200 tracked), axial (20-200 zones) reaction rates Domain decomposition, splitting the calculation and the memory storage, among several nodes is challenging as it involves communication of particles across domain boundaries We created a new MOOSE application, MaCaw, to study this problem Algorithms developed for ray tracing in MOOSE were adapted for simulating neutral particle transport Physics and tally routines in OpenMC, dynamically linked, are called from the application

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Guiding center model to interpret neutral particle analyzer results

An attempt is made to model the essential features of ion motion in a plasma. A guiding center model is hypothesized for a plasma heating device whose radial electric fields and axial magnetic fields are crossed. The guiding center model is shown to give results which agree with experimental data from four different plasma heating devices and are helpful for the interpretation of neutral particle analyzer results.

Englert, G. W.↗

Imaging electric field with electrically neutral particles

It used to think that is impossible to determine/measure electric field inside a physically isolated volume, especially inside an electrically shielded space, because a conventional electric-field sensor can only measure electric field at the location of the sensor, and when an electric-field source is screened by conductive materials, no leakage electric field can be detected. For first time, we experimentally demonstrated that electrically neutral particles, neutrons, can be used to measure/image electric field behind a physical barrier. This work enables a new measurement capability that can visualize electric-relevant properties inside a studied sample or detection target for scientific research and engineering applications.

42 ENGINEERING↗

Upper limits for X-ray and energetic neutral particle emission from Jupiter - Voyager-1 results

The X-ray sensitivity of the low energy proton channels in the Low Energy Charged Particle (LECP) experiment and its directional measurements determined whether X-rays from Jupiter can be recognized as additional flux above background as Voyager 1 approached the planet. Between about 230 and about 100 R(J), a statistically significant count rate was detected interpreted as X-rays and/or neutral particles. Such an X-ray flux leads to estimates of precipitating electrons over the Jovian polar caps which are 200 times larger than over observed electron fluxes in the Io plasma torus.

Kirsch, E.↗

Response of the neutral particle upper atmosphere to the solar eclipse of 7 March 1970.

Results of soundings with a series of five pitot probes launched in conjunction with the solar eclipse of Mar. 7, 1970. Three soundings were programmed to occur at 40, 80, and 100% obscuration of the sun (at 100 km) during a 42-min period. The remaining two soundings were made 24 hr before and after the eclipse. The five soundings yielded neutral particle pressure, temperature, and density profiles over the altitude regime from 30 to 125 km. Below 95 km, the three density profiles resulting from the eclipse day launches had an average deviation of less than 1.5%. Above 95 km, density changes of up to 20% were observed. Such changes in density are comparable in magnitude to those normally observed over a period of several hours. On Mar. 10, 1971, three additional pitot probes were launched at times identical to those of the 1970 eclipse day. Comparison of the two sets of data should provide for a more objective analysis regarding atmospheric response to solar input.

Horvath, J. J.↗