Electronics implementation of the solar neutron experiment
The electronic equipment design and function are discussed for the solar neutron counter experiment. Circuit diagrams are included.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
The electronic equipment design and function are discussed for the solar neutron counter experiment. Circuit diagrams are included.
Whether the Sun has significantly influenced the climate during the last century has been under extensive debates for almost two decades. Since the solar irradiance varies very little in a solar cycle, it is puzzling that some geophysical parameters show proportionally large variations which appear to be responding to the solar cycles. For example, variation in low altitude clouds is shown correlated with solar cycle, and the onset of Forbush decrease is shown correlated with the reduction of the vorticity area index. A possible sun-climate connection is that galactic cosmic rays modulated by solar activities influence cloud formation. In this paper, we apply wavelet transform to satellite and surface data to examine this hypothesis. Data analyzed include the time series for solar irradiance, sunspots, UV index, temperature, cloud coverage, and neutron counter measurements. The interactions among the elements in the Earth System under the external and internal forcings give out very complex signals.The periodicity of the forcings or signals could range widely. Since wavelet transforms can analyze multi-scale phenomena that are both localized in frequency and time, it is a very useful technique for detecting, understanding and monitoring climate changes.
We present a new analysis of the sensitivity of a water Cherenkov-based neutron multiplicity counter for nondestructive assay of trace quantities of 240 Pu. The multiplicity counter [water-based neutron detector (WaND)] contains 1.0 m 3 of water doped with 0.2% gadolinium in the form of a gadolinium salt (0.4% GdCl 3 ). It can be used for testing the presence of trace quantities of 240 Pu within a sample of unknown material by observing the correlated timing behavior of neutron capture candidates in the detector. The new analysis takes advantage of the fact that the detector is comprised almost entirely of a homogeneous medium, which permits the use of a simple model to reproduce the observed neutron capture timing behavior. Finally, the results of this analysis indicate that the detector has an absolute neutron detection efficiency of 23.4 ± 1.1% and is sensitive to a 240 Pu mass as small as 2.3 mg (at 1σ) after a 1-h data acquisition.
Neutron well counters provide a means to measure fissile mass by detecting coincident neutrons, which is a unique signature to fission. For coincidence counting, mass is determined using a calibration curve established with items that have the same material characteristics. Multiplicity analysis solves the point model equations for mass using known detector parameters. In both cases, mass measurements may exhibit a bias due to item characteristics and should be corrected for. Experiments can be done to estimate bias and material effects, but they require having both the well counter and the material well defined. In pursuit of estimating measurement bias and uncertainty in a High Efficiency Neutron Counter (HENC), an MCNP simulation was matched to measurements performed with an Active Well Coincidence Counter (AWCC) to de ne a neutron source term. The neutron source term will be used to predict measurement performance of similar material types in a HENC.
The objective of this research was to create an algorithm to provide an estimate of special nuclear material (SNM) mass using only neutron count rate data from a Radioisotope Identification Device (RIID), rather than using time-correlated data from a neutron multiplicity counter. To meet this objective neutron count rate measurements of a 252 Cf source were taken at varying distances with an ORTEC Detective X, FLIR Identifinder 2, and an ORTEC RADEAGLET-R. An algorithm was created to estimate mass of SNM utilizing the singles rate equation and the measured absolute efficiency curves.
This report details the development of a neutron multiplicity counter based on lithium doped plastic scintillators. This system has the capability to measure and discriminate fast neutrons, thermal neutrons, and gamma-rays allowing for multi-particle correlations in one device. The system was built and tested at Lawrence Livermore National Laboratory with Cf-252 in both bare configurations and surrounded by polyethylene and compared against the MC-15 multiplicity counter. Additionally, the detector was also placed outside of a subcritical assembly and demonstrated the ability to use correlated gamma-rays as a probe on the multiplication of the item.
The Samarkand complex setup is aimed at the study of cosmic ray variations in a wide energy range from 7 billion eV (which corresponds to the geomagnetic threshold in the region of Samarkand) up to approx 10 to the 15th power to 10 to the 16th power eV. The setup consists of four 6-counter sections of neutron supermonitor with counters SNM-15 and 48 scintillator detectors (1 sq m each) placed under and above the supermonitor. The effective area of the setup for recording neutrons and muons is 24 sq m. The setup can register time variations of the following cosmic ray components: (1) the total neutron counting rate, (2) counting rates for neutrons of different multiplicity, (3) soft-muon fluxes, (4) hard-muon fluxes at various zenith and azimuth angles, (5) electron-photon component, (6) extensive air showers (EAS) induced by primary particles in a wide energy range and accompanied or not accompanied by muons and neutrons.
During FY2023, three measurement campaigns were conducted at Oak Ridge National Laboratory. The goal was to quantify the neutron signatures of samples of uranium oxide containing uranium 233 and uranium-235. This report presents the neutron multiplicity data obtained using the large volume active well coincidence counter (LV-AWCC).
During core helium and carbon burning in massive stars, neutrons are produced mainly by the 22 Ne (𝛼,𝑛) 25 Mg reaction. Some of these released neutrons are captured by heavy seed nuclei from previous nucleosynthesis events, resulting in the slow production of many of the elements between masses 60 ≤ 𝐴 ≤ 90 via the weak 𝑠 process. Determining the overall neutron flux available in this environment is one of the main challenges in modeling its contributions to heavy element production. Not only must the reaction rate be well defined for the primary neutron source, but the rates of neutron poison and recycling reactions must also be well determined. One critical reaction in the simulation network is 25 Mg (𝛼,𝑛) 28 Si. This reaction, together with 25 Mg (𝑛,𝛾) 26 Mg and 25 Mg (𝛼,𝛾) 29 Si, determine how 25 Mg nuclei affect the available neutron flux. Past attempts to measure the 25 Mg (𝛼,𝑛) 28 Si cross section using neutron moderator counters have been greatly hindered by lower-𝑍 background reactions. Here, in the present work, neutron spectroscopy with deuterated liquid scintillator detectors has been used. The experimental spectra have been analyzed by applying spectrum unfolding techniques to achieve improved background discrimination for the 25 Mg (𝛼,𝑛) 28 Si reaction at low energies, down to 𝐸 𝛼 = 1.75 MeV. The separation of the different background contributions gives further insight into the results of previous moderator counter measurements and the measurements lead to a revised and more reliable determination of the reaction rate.
Any quantity of special nuclear material must be accurately quantified for health, safety, and security concerns. High-Level Neutron Coincidence Counters (HLNCCs) are detectors used for assaying the mass of special nuclear material. HLNCCs record a neutron count rate over some period of time which is compared to a calibration curve to determine the quantity of special nuclear material present within the detector.
Computations are carried out in transport approximation (first collision method) for the attenuation of the field of thermal neutrons formed in counters of the CHM-8 and CHMO-5 type. The deflection of the thermal neutron field is also obtained near the counters and in the air (shade effect) and in various decelerating media (water, paraffin, plexiglas) for which the calculations are carried out on the basis of diffusion theory. To verify the calculations, the distribution of the density of the thermal neutrons at various distances from the counter in the water is measured.
Plutonium oxide calibration standards STD4C, STD6C and STD8C have been historically used, and are currently the only MT52 standards in use, for calibration and measurement control program of Passive/Active Neutron Coincidence Counter known as PAN1 at PF-4. In this paper, previously measured high-statistics data are used in conjunction with neutron multiplicity equations to determine multiplication M and α parameter of these standards as the explicit knowledge of these parameters may allow quantification of precision and bias of accountability measurements of different material types and matrices of items.
The interpretation of observations of cooling neutron star crusts in quasipersistent x-ray transients is affected by predictions of the strength of neutrino cooling via crust Urca processes. The strength of crust Urca neutrino cooling depends sensitively on the electron-capture and β -decay ground-state-to-ground-state transition strengths of neutron-rich rare isotopes. Nuclei with a mass number of A = 61 are predicted to be among the most abundant in accreted crusts, and the last remaining experimentally undetermined ground-state-to-ground-state transition strength was the β decay of 61 V. This Letter reports the first experimental determination of this transition strength, a ground-state branching of $8.1^{+4.0}_{- 3.1}%$, corresponding to a log ft value of $5.5^{+0.2}_{-0.2}$. This result was achieved through the measurement of the β -delayed γ rays using the total absorption spectrometer SuN and the measurement of the β -delayed neutron branch using the neutron long counter system NERO at the National Superconducting Cyclotron Laboratory at Michigan State University. This method helps to mitigate the impact of the pandemonium effect in extremely neutron-rich nuclei on experimental results. The result implies that A = 61 nuclei do not provide the strongest cooling in accreted neutron star crusts as expected by some predictions, but that their cooling is still larger compared to most other mass numbers. Finally, only nuclei with mass numbers 31, 33, and 55 are predicted to be cooling more strongly. However, the theoretical predictions for the transition strengths of these nuclei are not consistently accurate enough to draw conclusions on crust cooling. With the experimental approach developed in this work, all relevant transitions are within reach to be studied in the future.
Simulations with the Monte Carlo N-Particle® (MCNP®) code are frequently used to study neutron coincidence counters for international safeguards. Reducing sources of uncertainty enables more accurate simulations, which reduces the need for expensive or impossible measurements. Accurately specifying the density of polyethylene is crucial for accurate simulations. The density of polyethylene ranges from 0.88 to 0.97 g/cm 3 and high-density polyethylene (HDPE) ranges from about 0.944 to 0.965 g/cm 3 . The density of a specific detector should be measured exactly for the best simulations. Here, the density of the blue/white Active Well Coincidence Counter (AWCC) bulk polyethylene was measured to be 0.9594 +- 0.0013 g/cm 3 at 1-sigma confidence. The density was calculated from repeated measurements of the various polyethylene dimensions for volume, and weighing the polyethylene for the mass. The AWCC neutron detection efficiency was simulated for each polyethylene density. The relative range of efficiencies (3σ) was 3.4% for unspecified polyethylene, 0.9% for HDPE, and 0.3% for the measured density. The impact of modeling small features such as screws was also studied and was found to be a negligible 0.2%. Measuring polyethylene density can reduce its role in uncertainty from one of the largest to one of the smallest contributors.
Californium-252 is an isotope commonly encapsulated as a physically small but strong spontaneous fission neutron source for applications in industry, academia, and research. Within the nuclear safeguards community, a well-characterized 252 Cf source is often used as an accessible alternative for plutonium in calibrations measurements, which require the absolute source strength. Current methods of source strength quantification can provide an accurate estimate, approximately 1% uncertainty under optimal conditions, but are typically costly and time consuming. An alternative method was developed to determine 252 Cf source strength using passive neutron correlation counting (PNCC). The PNCC method enables institutions and facilities to perform 252 Cf source calibration measurements in-house using detection systems that are common within the nuclear safeguards community. This novel method was previously successfully demonstrated using neutron multiplicity well counters. However, the previous evaluation utilized detection systems with high neutron detection efficiencies, greater than 60%. The purpose of the current study is to extend the previous evaluation and demonstrate the feasibility of the PNCC 252 Cf calibration method for suite of coincidence counters with lower neutron detection efficiencies, between 15% and 35%, which are more commonly encountered in the field, as well as to provide a step-by-step guide to using the method. The neutron source used in this evaluation was previously certified by the National Institutes of Science and Technology (NIST), which provides a reference for the accuracy of the PNCC method. In conclusion, the present source yield calculations demonstrate excellent agreement with a NIST calibration technique and achieve a standard uncertainty below the target 1%.
The β-decay properties of nuclei near the second nuclear “island of inversion” around neutron rich nuclei with neutron number 40 are important tests of nuclear structure models and interactions. In particular, the β-delayed neutron emission branch (Ρ n ), is useful for investigating β-strength and neutron-γ competition above the neutron separation energies of the daughter nuclei. We report new constraints for Ρ n values for three nuclei in the region: 62 Cr (Ρ n <1%), 64 Mn (Ρ n = 1.5(6)%), and 65 Fe (Ρ n < 1%), measured with the Neutron Emission Ratio Observer (NERO) neutron long counter system and the Beta Counting Station (BCS) at the National Superconducting Cyclotron Laboratory (NSCL). Our results resolve the large discrepancy between previous direct and indirect measurements for 64 Mn and confirm the predictions of global theoretical models when a statistical treatment of the γ and neutron decays of the daughter states is included. Here we also obtain improved half-lives for 62 Cr [206(5) ms] and the short-lived isomer in the 62 Fe daughter [112(7) ms] from β-delayed γ emission data obtained in the same experiment with the Summing NaI (SuN) total absorption spectrometer. Finally, we use γ emission data to obtain a new upper limit for the 62 Cr β-decay population of the long-lived isomeric state in 62 Mn.
This work proposes a preliminary neutron dose rate estimation method for a neutron multiplicity detector through measurement- and simulation-based analyses. Uncharacterized neutron-emitting sources may be encountered in situations such as nuclear emergency response, safeguards, and treaty verification. These circumstances may present irradiation risk to personnel conducting field assay, search, and characterization measurements. It is therefore of interest to provide a field neutron dosimetry capability with the existing neutron multiplicity counting (NMC) capabilities. To date, no commercially-available neutron detection systems are capable of both accurate NMC and real-time neutron dosimetry. This work will focus on estimating dose rate using input from a single fielded NMC called the MC-15. The energy-dependent neutron detection efficiency response of the MC-15 was quantified in monoenergetic neutron simulations and evaluated in response to two neutron-emitting sources and to a polyethylene-moderated source. The results were compared to existing neutron dosimeters and established the proof of concept for further investigation of the MC-15 for dose estimation. Measurement results were also replicated in simulations; additional simulations were then conducted to expand upon the limited empirical data. The initial empirical results provided a conversion factor appropriate for use when measuring 252 Cf neutrons that is independent of polyethylene shielding presence and thickness. The simulated data sets were then used to evaluate a fit equation allowing estimation of the neutron dose rate for less restricted geometric configurations and dependent only on the distance between the source and the detector. Additionally, the energy dependence of the efficiency response indicates that further empirical evaluations could provide energy-dependent conversion factors for broader neutron dosimetry capabilities with a wider range of neutron-emitting sources.
– Gas-filled neutron detectors have numerous applications across the nuclear engineering and nuclear physics fields. The ability to accurately model and simulate these detectors is important for those applications but is currently limited by the lack of readily-useable detector response software. Recently, the capabilities of DRiFT, a Detector Response Function Toolkit, were expanded to model gas-filled, He-3 and BF3, neutron detectors so that, combined with the radiation transport capabilities of the MCNP code, a high-fidelity treatment of gas-filled neutron detectors can be obtained. Further, this model has been validated by an experiment carried out with the Epithermal Neutron Multiplicity Counter and its capabilities have been demonstrated in two additional experiments. This work shows that utilizing DRiFT to post-process MCNP outputs produces more accurate results than using the MCNP code alone, reducing the difference between experimental and simulated results for measurements taken near the end of a He-3 tube, where the MCNP code struggles to model inactive regions of the detector, from a maximum of 35% with the MCNP code alone to 15% with the MCNP code plus DRiFT. DRiFT's diagnostic capabilities are also demonstrated with measurements for scenarios when pulse pileup or room return effects are significant and must be considered. Altogether, these measurements underpin the ability of DRiFT to accurately model and predict the behavior of gas-filled neutron detectors, making it a valuable tool for the design and testing of systems and experiments that utilize these detectors.