Search NASA⌕ Search

SEARCH · Search NASA

Results for “NEUTRON COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

β Decay of 61 V and its Role in Cooling Accreted Neutron Star Crusts

The interpretation of observations of cooling neutron star crusts in quasipersistent x-ray transients is affected by predictions of the strength of neutrino cooling via crust Urca processes. The strength of crust Urca neutrino cooling depends sensitively on the electron-capture and β -decay ground-state-to-ground-state transition strengths of neutron-rich rare isotopes. Nuclei with a mass number of A = 61 are predicted to be among the most abundant in accreted crusts, and the last remaining experimentally undetermined ground-state-to-ground-state transition strength was the β decay of 61 V. This Letter reports the first experimental determination of this transition strength, a ground-state branching of $8.1^{+4.0}_{- 3.1}%$, corresponding to a log ft value of $5.5^{+0.2}_{-0.2}$. This result was achieved through the measurement of the β -delayed γ rays using the total absorption spectrometer SuN and the measurement of the β -delayed neutron branch using the neutron long counter system NERO at the National Superconducting Cyclotron Laboratory at Michigan State University. This method helps to mitigate the impact of the pandemonium effect in extremely neutron-rich nuclei on experimental results. The result implies that A = 61 nuclei do not provide the strongest cooling in accreted neutron star crusts as expected by some predictions, but that their cooling is still larger compared to most other mass numbers. Finally, only nuclei with mass numbers 31, 33, and 55 are predicted to be cooling more strongly. However, the theoretical predictions for the transition strengths of these nuclei are not consistently accurate enough to draw conclusions on crust cooling. With the experimental approach developed in this work, all relevant transitions are within reach to be studied in the future.

79 ASTRONOMY AND ASTROPHYSICS↗

Polyethylene density uncertainty in the simulation of neutron detectors

Simulations with the Monte Carlo N-Particle® (MCNP®) code are frequently used to study neutron coincidence counters for international safeguards. Reducing sources of uncertainty enables more accurate simulations, which reduces the need for expensive or impossible measurements. Accurately specifying the density of polyethylene is crucial for accurate simulations. The density of polyethylene ranges from 0.88 to 0.97 g/cm 3 and high-density polyethylene (HDPE) ranges from about 0.944 to 0.965 g/cm 3 . The density of a specific detector should be measured exactly for the best simulations. Here, the density of the blue/white Active Well Coincidence Counter (AWCC) bulk polyethylene was measured to be 0.9594 +- 0.0013 g/cm 3 at 1-sigma confidence. The density was calculated from repeated measurements of the various polyethylene dimensions for volume, and weighing the polyethylene for the mass. The AWCC neutron detection efficiency was simulated for each polyethylene density. The relative range of efficiencies (3σ) was 3.4% for unspecified polyethylene, 0.9% for HDPE, and 0.3% for the measured density. The impact of modeling small features such as screws was also studied and was found to be a negligible 0.2%. Measuring polyethylene density can reduce its role in uncertainty from one of the largest to one of the smallest contributors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

252 Cf yield calibration method for nuclear material accountancy and safeguards practitioners

Californium-252 is an isotope commonly encapsulated as a physically small but strong spontaneous fission neutron source for applications in industry, academia, and research. Within the nuclear safeguards community, a well-characterized 252 Cf source is often used as an accessible alternative for plutonium in calibrations measurements, which require the absolute source strength. Current methods of source strength quantification can provide an accurate estimate, approximately 1% uncertainty under optimal conditions, but are typically costly and time consuming. An alternative method was developed to determine 252 Cf source strength using passive neutron correlation counting (PNCC). The PNCC method enables institutions and facilities to perform 252 Cf source calibration measurements in-house using detection systems that are common within the nuclear safeguards community. This novel method was previously successfully demonstrated using neutron multiplicity well counters. However, the previous evaluation utilized detection systems with high neutron detection efficiencies, greater than 60%. The purpose of the current study is to extend the previous evaluation and demonstrate the feasibility of the PNCC 252 Cf calibration method for suite of coincidence counters with lower neutron detection efficiencies, between 15% and 35%, which are more commonly encountered in the field, as well as to provide a step-by-step guide to using the method. The neutron source used in this evaluation was previously certified by the National Institutes of Science and Technology (NIST), which provides a reference for the accuracy of the PNCC method. In conclusion, the present source yield calculations demonstrate excellent agreement with a NIST calibration technique and achieve a standard uncertainty below the target 1%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

β -delayed neutron emission of Mn 64 , Cr 62 , and Fe 65

The β-decay properties of nuclei near the second nuclear “island of inversion” around neutron rich nuclei with neutron number 40 are important tests of nuclear structure models and interactions. In particular, the β-delayed neutron emission branch (Ρ n ), is useful for investigating β-strength and neutron-γ competition above the neutron separation energies of the daughter nuclei. We report new constraints for Ρ n values for three nuclei in the region: 62 Cr (Ρ n <1%), 64 Mn (Ρ n = 1.5⁢(6)%), and 65 Fe (Ρ n < 1%), measured with the Neutron Emission Ratio Observer (NERO) neutron long counter system and the Beta Counting Station (BCS) at the National Superconducting Cyclotron Laboratory (NSCL). Our results resolve the large discrepancy between previous direct and indirect measurements for 64 Mn and confirm the predictions of global theoretical models when a statistical treatment of the γ and neutron decays of the daughter states is included. Here we also obtain improved half-lives for 62 Cr [206(5) ms] and the short-lived isomer in the 62 Fe daughter [112(7) ms] from β-delayed γ emission data obtained in the same experiment with the Summing NaI (SuN) total absorption spectrometer. Finally, we use γ emission data to obtain a new upper limit for the 62 Cr β-decay population of the long-lived isomeric state in 62 Mn.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of neutron dosimetry capabilities with the MC-15 portable multiplicity counter

This work proposes a preliminary neutron dose rate estimation method for a neutron multiplicity detector through measurement- and simulation-based analyses. Uncharacterized neutron-emitting sources may be encountered in situations such as nuclear emergency response, safeguards, and treaty verification. These circumstances may present irradiation risk to personnel conducting field assay, search, and characterization measurements. It is therefore of interest to provide a field neutron dosimetry capability with the existing neutron multiplicity counting (NMC) capabilities. To date, no commercially-available neutron detection systems are capable of both accurate NMC and real-time neutron dosimetry. This work will focus on estimating dose rate using input from a single fielded NMC called the MC-15. The energy-dependent neutron detection efficiency response of the MC-15 was quantified in monoenergetic neutron simulations and evaluated in response to two neutron-emitting sources and to a polyethylene-moderated source. The results were compared to existing neutron dosimeters and established the proof of concept for further investigation of the MC-15 for dose estimation. Measurement results were also replicated in simulations; additional simulations were then conducted to expand upon the limited empirical data. The initial empirical results provided a conversion factor appropriate for use when measuring 252 Cf neutrons that is independent of polyethylene shielding presence and thickness. The simulated data sets were then used to evaluate a fit equation allowing estimation of the neutron dose rate for less restricted geometric configurations and dependent only on the distance between the source and the detector. Additionally, the energy dependence of the efficiency response indicates that further empirical evaluations could provide energy-dependent conversion factors for broader neutron dosimetry capabilities with a wider range of neutron-emitting sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulating gas-filled neutron detector responses with DRiFT

– Gas-filled neutron detectors have numerous applications across the nuclear engineering and nuclear physics fields. The ability to accurately model and simulate these detectors is important for those applications but is currently limited by the lack of readily-useable detector response software. Recently, the capabilities of DRiFT, a Detector Response Function Toolkit, were expanded to model gas-filled, He-3 and BF3, neutron detectors so that, combined with the radiation transport capabilities of the MCNP code, a high-fidelity treatment of gas-filled neutron detectors can be obtained. Further, this model has been validated by an experiment carried out with the Epithermal Neutron Multiplicity Counter and its capabilities have been demonstrated in two additional experiments. This work shows that utilizing DRiFT to post-process MCNP outputs produces more accurate results than using the MCNP code alone, reducing the difference between experimental and simulated results for measurements taken near the end of a He-3 tube, where the MCNP code struggles to model inactive regions of the detector, from a maximum of 35% with the MCNP code alone to 15% with the MCNP code plus DRiFT. DRiFT's diagnostic capabilities are also demonstrated with measurements for scenarios when pulse pileup or room return effects are significant and must be considered. Altogether, these measurements underpin the ability of DRiFT to accurately model and predict the behavior of gas-filled neutron detectors, making it a valuable tool for the design and testing of systems and experiments that utilize these detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of Neutron Multiplicity Counting Experiments to Optimal Cross-Section Adjustments

This paper presents the first application of model calibration to neutron multiplicity counting (NMC) experiments for cross-section optimization that is informed by adjoint-based sensitivity analysis (SA) and first-order uncertainty quantification (UQ). We summarize previous work on SA applied to NMC and describe notable modifications and additions. We give the procedure for first-order UQ and Bayesian-inference-based parameter estimation (PE). We then discuss model calibration applied to NMC of a 4.5-kg sphere of weapons-grade, alpha-phase plutonium metal (the BeRP ball) with the nPod neutron multiplicity counter. For the BeRP ball in bare and polyethylene-reflected configurations, we discuss the sensitivity of the first- and second-moment detector responses (i.e., first and second moments of the NMC distribution, respectively) to the cross sections. We describe the sources of uncertainty in the measured and simulated responses. Specifically, uncertainty in the measured responses is due to both random and systematic sources. Uncertainty in the simulated responses is due to the cross-section covariances. We describe in detail the adjustment to the cross sections and cross-section covariances due to the optimization. Due to the contribution of systematic uncertainties to the measured response uncertainties, the adjustment to the cross sections is similar in trend but larger in magnitude compared to that recommended by previous work. We compare the measured responses to responses simulated with nominal and optimized cross sections, demonstrating that the best-estimate cross sections produce simulations of NMC experiments that are more accurate with reduced uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Deployment of a double scatter system for directional detection of background neutron radiation

The detection of special nuclear materials (SNM) requires the understanding of nuclear signatures that allow the discrimination against background. In particular, understanding neutron background characteristics such as count rates and energies and their correlations with environmental conditions and surroundings of measurement locations is important in enhancing SNM detection capabilities. The Mobile Imager of Neutrons for Emergency Responders (MINER) was deployed for 8 weeks in downtown San Francisco (CA) to study such neutron background characteristics in an urban environment. Of specific interest was the investigation of the impact of surrounding buildings on the neutron background count rates and to answer the question whether buildings act as absorber of neutrons or as sources via the so-called ship effect. MINER consists of 16 liquid scintillator detector elements and can be operated as a neutron spectrometer, as a neutron imager, or simply as a counter of fast neutrons. As expected, the neutron background rate was found to be inversely proportional to the atmospheric pressure. In the energy range where MINER is most sensitive, approximately 1–10 MeV, it was found that the shape of the detected background spectrum is similar to that of a detected fission spectrum, indicating the limited discrimination power of the neutron energy. The similarities between the detected background neutron spectrum and fission sources makes it difficult to discriminate SNM from background based solely on the energies observed. The images produced using maximum likelihood expectation maximization revealed that neutrons preferentially are coming from areas in the environment that have open sky, indicating that the surrounding buildings act as absorbers of neutrons rather than sources as expected by the ship effect. Here, the inherent properties of a neutron scatter camera limit the achievable image quality and the effective deployment to systematically map neutron background signatures due to the low count rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A parallel-plate avalanche counter for the prompt fission neutron spectrum measurement

Neutrons, gamma’s, and fission fragments are among the prompt fission observables. Their precision measurements are fundamental to advance our understanding of fission and any application of fission. For our programmatic need, the χ matrix, which defines as the outgoing neutron spectrum as a function of incoming neutron energy, is sparsely populated and poorly measured for 233,235,238 U and 239,240 Pu. To improve the quality of those χ matrices, a joint LANLLLNL project was undertaken to measure their prompt fission neutron spectra at the LANSCE/WNR facility using neutron detector arrays and a charged-particle detector for the fission-fragment detection. A typical setup is shown in Fig. 1, where one of neutron detector array with a charged-particle detector is given.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NCSP – AWE Collaboration [Slides]

Several points of collaboration between NCSP and AWE are noted, including the CIDAAS IS589 installation plan, CIDAAS testing, nuclear verification and detector physics, nuclear material control and nuclear security, and hands on criticality safety training.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modeling and Simulation of MC-Small Design

In order to design a lightweight, highly portable neutron multiplicity counter for use in higher risk regions by mobile field teams, a redesign of the MC-15 is being performed, with the goal of producing a detector below 30 lbs for ease of transport. To achieve this, multiple MCNP® simulations were run, evaluating the number and positioning of the He-3 tubes in the detector as well as the amount of high-density polyethylene (HDPE) surrounding the tubes. Based on these simulations, the proposed redesign of the MC-15 (aka MC-Small) possesses 11 tubes and is 13 in wide, 3.21 in thick and 13 in tall. Including the changes to the positioning of the tubes and the removal of HDPE from less sensitive regions of the detectors (i.e. bases of tubes, back of detector), this resulted in an efficiency of 0.56% when measuring a bare Cf-252 source 19.69 in away, only 28% less efficient (relatively) than the MC-15 while weighing 18 lbs, 12 lbs less than the weight of the MC-15.

42 ENGINEERING↗

Neutron Coincidence Measurements of Uranium-233 Oxide

Renewed international interest in thorium-fueled advanced reactors has challenged the safeguards community to address future proliferation concerns. Thorium-based technology presents many benefits but does not eliminate the proliferation risks associated with producing and processing fissile material. A byproduct of thorium-fueled reactors is uranium-233, which is classified as a direct-use material. As a result, the development of new or improved methods to characterize and measure materials containing 233U must mirror the pace of development of reactors and facilities that produce such material. Research is underway to assess, develop, and test approaches for safeguarding nuclear materials within the thorium fuel cycle. Neutron signatures from the nondestructive assay (NDA) of materials containing 233U are being quantified to inform the potential characterization of these materials. Using a traditional neutron coincidence counter and a series of well-documented 233U oxide samples, initial measurements have been made to assess the feasibility of 233U characterization and discrimination from other uranium isotopes, primarily 235U, using a combination of measurement techniques and analysis methods. Data acquisition is performed in list mode, allowing for a variety of analyses to be performed on the raw data that is not available using traditional shift register technology. Measurements were performed in passive and active configurations to quantify the strength of signal and to validate simulations in support of this work. This paper presents and discusses the results of the initial measurements of 233U oxide performed at Oak Ridge National Laboratory.

Lockhart, Madeline↗

Reduction of detection limit and quantification uncertainty due to interferent by neural classification with abstention

Many measurements in the physical sciences can be cast as counting experiments, where the number of occurrences of a physical phenomenon informs the prevalence of the phenomenon's source. Often, detection of the physical phenomenon (termed signal) is difficult to distinguish from naturally occurring phenomena (termed background). In this case, the discrimination of signal events from background can be performed using classifiers, and they may range from simple, threshold-based classifiers to sophisticated neural networks. These classifiers are often trained and validated to obtain optimal accuracy, however we show that the optimal accuracy classifier does not generally coincide with a classifier that provides the lowest detection limit, nor the lowest quantification uncertainty. Here, we present a derivation of the detection limit and quantification uncertainty in the classifier-based counting experiment case. We also present a novel abstention mechanism to minimize the detection limit or quantification uncertainty a posteriori. We illustrate the method on two data sets from the physical sciences, discriminating Ar-37 and Ar-39 radioactive decay from non-radioactive events in a gas proportional counter, and discriminating neutrons from gammas in an inorganic scintillator and report results therefrom.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review of Direct Neutron Conversion and Detection Processes

Commercial and laboratory neutron detection systems use indirect neutron response of materials like pressurized helium-3 (via nuclear reaction 3He(n, p)3H) to measure and count neutrons emanating from a source. Recently a host of semiconductors, especially a ternary semiconductor of lithium indium diselenide (6LiInSe2) and a quaternary alloy of enriched lithium-6, indium, phosphorous, and selenium (6LiInP2Se6), have shown promising neutron counting possibilities by directly converting neutrons into charge-carrying elements within the body of the semiconductor. These semiconductors have high thermal neutron capture cross sections, suitable energy bandgaps (~2.0 electron volts) for room-temperature operations, and a favorable electronic band structure for efficient electron charge transport. The article examines the semiconductor properties of these compounds in terms of their neutron counting capabilities and possible ways to extract neutron energy information from them. Lithium-6 and boron-10 (with thermal neutron absorption cross sections of 938 ± 6 and 3855 ± 26 barns, respectively) produce charged particles to be measured via indirect neutron interactions. The efficiency of indirect conversion neutron detectors is limited because of the inefficiencies in conversion mechanism. In case of direct conversion, the neutrons create charged particles in a single material for neutron capture and charge collection, increasing detection efficiency. Unlike 3He proportional counters, which provide no neutron energy information, the semiconductors can be used as neutron energy spectrometer. Fully resolved neutron energy by 6LiInP2Se6 from a plutonium-beryllium source has been reported in the literature. We will discuss the influence of these multilayered semiconductors’ crystallographic structures and growth techniques on neutron energy determination.

61 RADIATION PROTECTION AND DOSIMETRY↗

Direct thermal neutron detection by the 2D semiconductor 6 LiInP 2 Se 6

Highly efficient neutron detectors are critical in many sectors, including national security, medicine, crystallography and astronomy. The main neutron detection technologies currently used involve 3 He-gas-filled proportional counters and light scintillators for thermalized neutrons. Semiconductors could provide the next generation of neutron detectors because their advantages could make them competitive with or superior to existing detectors. In particular, solids with a high concentration of high-neutron-capture nuclides (such as 6 Li, 10 B) could be used to develop smaller detectors with high intrinsic efficiencies. However, no promising materials have been reported so far for the construction of direct-conversion semiconductor detectors. Here we report on the semiconductor LiInP 2 Se 6 and demonstrate its potential as a candidate material for the direct detection of thermal neutrons at room temperature. This compound has a good thermal-neutron-capture cross-section, a suitable bandgap (2.06 electronvolts) and a favourable electronic band structure for efficient electron charge transport. We used α particles from an 241 Am source as a proxy for the neutron-capture reaction and determined that the compact two-dimensional (2D) LiInP 2 Se 6 detectors resolved the full-energy peak with an energy resolution of 13.9 per cent. Direct neutron detection from a moderated Pu–Be source was achieved using 6 Li-enriched (95 per cent) LiInP 2 Se 6 detectors with full-peak resolution. Here, we anticipate that these results will spark interest in this field and enable the replacement of 3 He counters by semiconductor-based neutron detectors.

36 MATERIALS SCIENCE↗

Measuring Neutron Polarisation in Deuteron Photo-disintegration with the CLAS Start Counter [Thesis]

Deuteron photo-disintegration (γd → γp) is a reaction that represents the simplest case in which nuclear and hadron physics models can be tested. Despite this, associated polarization analyses are limited in terms of angular coverage and energy ranges, especially in observables related to the recoil neutron. This is largely due to a lack in dedicated polarimetry equipment, and represents a roadblock in global progress to understand high-energy phenomena such as hexaquarks, and quark-gluon degrees of freedom. To address this problem, this PhD thesis pioneers a new methodology for the parasitic measurement of nucleon polarization using kinematic reconstruction of (spin-dependent) nucleon-nucleus scattering of reaction products, prior to their detection in large acceptance particle detector apparatus. Following this novel approach, which requires no dedicated polarimeter, a determination of the double polarization observable, $C^n_{x'}$, from deuteron photo-disintegration is presented, using Jefferson Lab’s CLAS detector. The analysis utilizes the (n,p) charge exchange reaction in CLAS’s "start counter" (plastic scintillator) to determine the final state neutron polarizations. The results present the first ever data for this observable above 0.7 GeV (photon beam energy) and significantly extend the angular range of the world data set. This new data is largely statistically consistent with the previous measurement of $C^n_{x'}$ by Bashkanov et al . in the overlapping energy range of 0.4-0.7 GeV. It is planned for the statistical accuracy of the presented result to be increased by the inclusion of additional data. The analysis herein serves as a key proof of concept for future applications, including a recommended similar analysis to be implemented with data from the more modern CLAS12 detector. This paves the way for a plethora of additional analyses using existing data sets that would provide crucial new constraints for hadron and nuclear physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A portable and monoenergetic 24 keV neutron source based on 124Sb-9Be photoneutrons and an iron filter

A portable monoenergetic 24 keV neutron source based on the 124Sb-9Be photoneutron reaction and an iron filter has been constructed and characterized. The coincidence of the neutron energy from SbBe and the low interaction cross-section with iron (mean free path up to 29 cm) makes pure iron specially suited to shield against gamma rays from 124Sb decays while letting through the neutrons. To increase the 124Sb activity and thus the neutron flux, a >1 GBq 124Sb source was produced by irradiating a natural Sb metal pellet with a high flux of thermal neutrons in a nuclear reactor. The design of the source shielding structure makes for easy transportation and deployment. A hydrogen gas proportional counter is used to characterize the neutrons emitted by the source and a NaI detector is used for gamma background characterization. At the exit opening of the neutron beam, the characterization determined the neutron flux in the energy range 20–25 keV to be 6.00±0.30 neutrons per cm2 per second and the total gamma flux to be 245±8 gammas per cm2 per second (numbers scaled to 1 GBq activity of the 124Sb source). A liquid scintillator detector is demonstrated to be sensitive to neutrons with incident kinetic energies from 8 to 17 keV, so it can be paired with the source as a backing detector for neutron scattering calibration experiments. This photoneutron source provides a good tool for in-situ low energy nuclear recoil calibration for dark matter experiments and coherent elastic neutrino-nucleus scattering experiments.

Dark Matter detectors (WIMPs, axions, etc.)↗