Search NASA⌕ Search

SEARCH · Search NASA

Results for “NEUTRON DISTRIBUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

From noise to information: The transfer function formalism for uncertainty quantification in reconstructing the nuclear density

The neutron distribution of neutron-rich nuclei provides critical information on the structure of finite nuclei and neutron stars. Parity violating experiments—such as PREX and CREX—provide a clean and largely model-independent determination of neutron densities. Such experiments, however, are challenging and expensive, which is why sound statistical arguments are required to maximize the information gained. We introduce a new framework, the “transfer function formalism,” aimed at uncertainty quantification, model selection, and experimental design in the context of neutron densities. The transfer functions (TFs) are built analytically by expressing the linear response of the objective function (e.g., χ2) to small perturbations of the data. Using the TF formalism, we are able to analyze the expected overall uncertainty—quantified in terms of bias and variance—of the mean square radius and interior density of 48 Ca and 208 Pb. Using relativistic mean field models as a proxy for the weak-charge density—and assuming that a total of five measurements could be performed on the weak form factor of 48 Ca and 208 Pb—we identify the optimal models and experimental locations that minimize the uncertainty in the extraction of the radius and interior density. We also explore the use of the TF formalism to understand the influence of prior distributions for the model parameters, as well as the optimization of model hyperparameters not constrained by the data. Here,we establish how the choice of experimental locations and the model that is used can have a significant impact on the final uncertainties of the extracted quantities of interest. For challenging experiments such as CREX and PREX, a proper quantification of such uncertainties is critical. We have demonstrated how the TF formalism provides several advantages for this type of analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Local distribution of old neutron stars

The local distribution of old disk neutron stars is approximated with a 1D model, in which the steady state distribution in the direction perpendicular to the Galactic plane is calculated, assuming a variety of the initial radio pulsar positions and velocities, and various Galactic potentials. It is found that the local distribution of old neutron stars is dominated by those that were born with very low velocities. The high-velocity neutron stars spend most of their lifetime far in the Galactic halo and do not contribute much to the local density. Therefore, the rms velocity at birth is not a good indicator of the scale height of the old population. The most likely half-density scale height for the old disk neutron stars is approximately 350 pc, the same as for the old disk G, K, and M stars. If gamma-ray bursts originate on old disk neutron stars, then 350 pc should also be the scale height for the bursters.

Frei, Szolt↗

Angular distribution of neutron production by proton and carbon-ion therapeutic beams

Carbon-ion beams are increasingly used in the clinical practice for external radiotherapy treatments of deep-seated tumors. At therapeutic energies, carbon ions yield significant secondary products, including neutrons, which may be of concern for the radiation protection of the patient and personnel. We simulated the neutron yield produced by proton and carbon-ion pencil beams impinging on a clinical phantom at three different angles: 15°, 45° and 90°, with respect to the beam axis. We validated the simulated results using the measured response of organic scintillation detectors. We compared the results obtained with FLUKA 2011.2 and MCNPX 2.7.0 based on three different physics models: Bertini, Isabel, and CEM. Over the different ions, energies, and angles, the FLUKA simulation results agree better with the measured data, compared to the MCNPX results. Simulations of carbon ions at low angles exhibit both the highest deviation from measured data and inter-model discrepancy, which is probably due to the different treatment of the pre-equilibrium stage. The reported neutron yield results could help in the comparison of carbon-ion and proton treatments in terms of secondary neutron production for radiation protection applications.

60 APPLIED LIFE SCIENCES↗

The neutron number probability distribution in coupled lumped assemblies

Here, the validity of the gamma distribution in describing the neutron number probability distribution function for both isolated and coupled multiplying assemblies when constrained to reproduce the true mean and variance is investigated in lumped geometry by numerical comparison with kinetic Monte Carlo simulations. The mean and variance are obtained from numerical solution of moment equations constructed from the relevant forward Master equation with assembly coupling coefficients obtained from a view factor method. Numerical results for a two-group, two coupled assemblies model, with static and dynamic reactivity insertion, show that except for subcritical assemblies, the gamma distribution well-approximates the number distribution. Differences in the fast and thermal neutron population shapes are explained in terms of effective source strengths due to downscatter and coupling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calculated angular distributions of energetic atmospheric neutrons

Calculated angular distributions of atmospheric leakage neutron fluxes from 19 MeV to 1 GeV are presented. Comparisons with the balloon measurements of Preszler et al. and Kanbach et al. are made and show substantial agreement, strengthening the belief in the importance of the CRAND (cosmic-ray albedo-neutron decay) contribution to the high-energy protons in the earth's inner radiation belt. The calculation is presented as a means for investigating features of atmospheric flux distributions.

Merker, M.↗

Thermodynamic non-ideality and disorder heterogeneity in actinide silicate solid solutions

Non-ideal thermodynamics of solid solutions can greatly impact materials degradation behavior. We have investigated an actinide silicate solid solution system (USiO 4 –ThSiO 4 ), demonstrating that thermodynamic non-ideality follows a distinctive, atomic-scale disordering process, which is usually considered as a random distribution. Neutron total scattering implemented by pair distribution function analysis confirmed a random distribution model for U and Th in first three coordination shells; however, a machine-learning algorithm suggested heterogeneous U and Th clusters at nanoscale (~2 nm). The local disorder and nanosized heterogeneous is an example of the non-ideality of mixing that has an electronic origin. Partial covalency from the U/Th 5f–O 2p hybridization promotes electron transfer during mixing and leads to local polyhedral distortions. The electronic origin accounts for the strong non-ideality in thermodynamic parameters that extends the stability field of the actinide silicates in nature and under typical nuclear waste repository conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of Parity Violating Asymmetry in Elastic Electron Scattering off 48Ca

Atomic nuclei are composed of nucleons governed by the strong nuclear force. Although the proton distributions in nuclei are well measured with electromagnetic probes, the neutron distributions are relatively unconstrained. The nuclear symmetry energy governs the distribution of the excess neutrons in asymmetric nuclei, as well as the dynamics of neutron-rich nuclear matter up to the scale of neutron stars….

Clarke, Cameron↗

Weak-charge form-factor determination at the electron-ion collider

Determining the weak charge form factor, 𝐹 𝑊 ⁡(𝑄 2 ), of nuclei over a continuous range of momentum transfers, 0 ≲ 𝑄 2 ≲ 0.1 GeV 2 , is essential for mapping out the distribution of neutrons in nuclei. The neutron density distribution has significant implications for a broad range of areas, including studies of nuclear structure, neutron stars, and physics beyond the Standard Model. Currently, our knowledge of 𝐹 𝑊 ⁡(𝑄 2 ) comes primarily from fixed target experiments that measure the parity-violating asymmetry in coherent elastic electron-ion scattering. Fixed target experiments, such as CREX and PREX-1,2, have provided high-precision weak charge form factor extractions for the 48 Ca and 208 Pb nuclei, respectively. However, a major limitation of fixed target experiments is that they each provide data only at a single value of 𝑄 2 . With the proposed electron-ion collider (EIC) on the horizon, we explore its potential to impact the determination of the weak charge form factor. While it cannot compete with the precision of fixed target experiments, it can provide data over a wide and continuous range of 𝑄 2 values, and for a wide variety of nuclei. We show that with data corresponding to an integrated luminosity of ℒ ∼ 500/𝐴 fb −1 , where 𝐴 is the nucleus atomic weight, the EIC can significantly impact constraints by lifting degeneracies in theoretical models of the neutron density distribution. Ensuring EIC detector coverage at low 𝑄 2 and large negative pseudorapidities will be essential for such 𝐹 𝑊 ⁡(𝑄 2 ) measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A preliminary area survey of neutron radiation levels associated with the NASA variable energy cyclotron horizontal neutron delivery system

The 25 MeV deuteron beam from the NASA variable energy cyclotron incident on a thick beryllium target will deliver a tissue neutron dose rate of 2.14 rad micron A-min at a source to skin distance of 125 cm. A neutron survey of the existing hallways with various shielding configurations made during operating of the horizontal neutron delivery system indicates that minimal amounts of additional neutron shielding material are required to provide a low level radiation environment within a self-contained neutron therapy control station. Measurements also indicate that the primary neutron distribution delivered by a planned vertical delivery system will be minimally perturbed by neutrons backscattered from the floor.

Roberts, W. K.↗

Benchmarking of Different Inverse Point Kinetics Implementations for an Autocorrected Reactimeter Algorithm

In November 2017, the Transient Reactor Test Facility returned to operation. Since that time, many transient test series have been completed; each has provided valuable data for materials performance, reactor safety that can be applied in future designs. During each experimental series, detector count rates provided important information on the core behavior during transients. However, a limitation of these data is that variations in the neutron distribution during experiments cause errors when attempting to infer reactivity evolution from detector signals. Neutron physics codes can be used to compute the flux shape variations. However, this is a poor solution when the experimental data is used to do verification, validation and uncertainty quantification (VVUQ) on codes. Indeed, if the output of the code is used both as a reference and to correct what the reference is compared to, the circular dependency limits the quality of the VVUQ approach. To overcome this problem, an Autocorrected Reactimeter Algorithm (ACRA) has been developed. This approach infers time-dependent reactivity evolution by testing different spatial corrections and selecting the one that minimizes reactivity variations when the core is in a frozen configuration (i.e. when there is no variation in parameters affecting reactivity). However, the scope of this method was limited to transients where there were negligible thermal feedback. Indeed, the core is never in a frozen configuration when the fuel temperature varies during the whole transient. This is our motivation for the development of an improved version of the ACRA which does not require frozen configurations

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

(Doublon) Benchmarking of Different Inverse Point Kinetics Implementations for an Autocorrected Reactimeter Algorithm

In November 2017, the Transient Reactor Test Facility returned to operation. Since that time, many transient test series have been completed, such as the Transient Heatsink Overpower Response capsule (THOR), the Transient Water Irradiation System for TREAT (TWIST), and Sirius. Each has provided valuable data for materials performance and reactor safety that can be applied in future designs. During each experimental series, detector count rates provided important information on the core behavior during transients. However, a limitation of these data is that variations in the neutron distribution during experiments can cause errors when attempting to infer reactivity evolution from detector signals. Neutron physics codes can be used to compute the flux shape variations. However, this is a poor solution when the experimental data is used for code verification, validation and uncertainty quantification. Indeed, if the output of the code is used both as a reference and to correct what the reference is compared to, the circular dependency limits the quality of the verification, validation and uncertainty quantification approach. To overcome this problem, the autocorrected reactimeter algorithm (ACRA) has been developed. This approach infers a time-dependent reactivity evolution by testing different spatial corrections and selecting the one that minimizes reactivity variations when the core is in a frozen configuration (i.e., when there is no variation in parameters affecting reactivity). However, the scope of this method was limited to transients where there were negligible thermal feedback. Indeed, the core is never in a frozen configuration when the fuel temperature varies during the whole transient. This is our motivation for developing an improved version of the ACRA that does not require frozen configurations. To develop this new algorithm, we need a precise and unbiased implementation of the inverse point kinetic equations (IPKEs) as any error in the reactivity evaluation will be propagated into the choice of the optimal spatial correction. Indeed, the previous reactimeter algorithm would use approximations, such as a negligible flux amplitude derivative, to focus on rapidity. For the numerical validation of ACRA, we aim at absolute error under for reactivity derived from signals similar to the one of this study. In this summary, we test eight different IPKE implementations. Each will process a mockup signal built for this study, similar to those that the future ACRA will process. Each reactivity output will be compared to the reference reactivity that has been used to generate the mockup signal. The implementation minimizing the difference with the reference reactivity will be used in the development of a new ACRA formulation.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Godiva IV Simulated Radiation Field Characterization and Variance Reduction

Godiva IV is a system comprised of highly enriched uranium alloyed with molybdenum in the form of fuel plate rings. The reactor, along with its predecessors, was designed with the unique ability to satisfy interests in the super-prompt-critical reactor operation space. Originally, the reactor was part of the Los Alamos Critical Experiments Facility (LACEF) at Technical Area-18 (TA-18). The radiation field around Godiva at this facility was well characterized and understood. As a fast neutron system, the neutron spectrum in and around Godiva was close to a Watt Fission spectrum. The Kiva where Godiva IV was located at LACEF was made of thin, sheet metal walls which did not contribute significantly to the neutron spectrum. Following the transition of LACEF to the National Critical Experiments and Research Center (NCERC) in Nevada, Godiva-IV was moved from TA-18 to the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS). Part of this move brought renewed interest in radiation field characterization. The new facility introduced significant changes to the environment surrounding Godiva, and preliminary foil irradiation results suggested that the room contribution to the neutron spectrum was significant. Unlike at TA-18, a large thermal neutron signature was added to the fast spectrum from Godiva due to significant room return. A primary goal due to the additional complexity that the room return adds to the Godiva IV radiation emission spectrum was the development of an efficient Monte Carlo N-Particle (MCNP) calculation capable of characterizing the neutron spectrum anywhere in the room around Godiva. A campaign of activation foil irradiations and analysis were completed to support the validation of the MCNP model. The modeling of these foils in MCNP can be easily done with a standard volumetric neutron flux tally. However, given the multitude of locations and reaction rates to be modeled, further steps must be taken to increase the efficiency of these calculations in MCNP. During this study, a benchmark model currently under development for Godiva IV was used. A qualitative assessment of the thermal neutron contributors was performed using spatial neutron distribution plots. Additional detail was added to the model based on the qualitative results showing the thermal spectrum’s large sensitivity to hydrogenous material. Neutron energy spectra was evaluated at discrete locations in the room around Godiva to quantify the relative contribution of various components. It was discovered that the concrete walls are the largest contributor to the thermal signature, with minor contributions from plastic components surrounding Godiva. Following these results, two different variance reduction techniques were implemented to improve the problem efficiency in these calculations. In the first approach, an F5 point detector tally was implemented in the standard Godiva IV criticality problem. The second approach involved a weight-window generator implementation with an F5 point detector tally in a fixed source problem. The weight window implementation reduced the runtime from 42739.55 minutes to 1803.34 minutes (computer time), compared to the F5 KCODE implementation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The effects of high-altitude explosions

Effects of high-altitude explosions - Satellite radiation measurements for Star Fish nuclear explosion, electron distribution, neutron decay, and electron flux

STAR FISH PROJECT↗

Assessment of PHDS Fulcrum40h and Ortec Detective-X High Purity Germanium (HPGe) Detector System Performance

This report provides a summary of measurement results used to compare the performance of the PHDS Fulcrum40h and Ortec Detective-X High Purity Germanium (HPGe) detector systems. Specifically, the measurement data collected was used to assess each detector system for gamma efficiency and resolution, gamma angular response and efficiency for an in-situ surface distribution, neutron efficiency, gamma pulse-pileup response, and gamma to neutron crosstalk.

42 ENGINEERING↗