At least 37 records · Page 2

Measured Thermal and Fast Neutron Fluence Rates ATR Cycles 167A

This report contains the thermal (2200 m/s) and fast (E>1 MeV) neutron fluence rate data for ATR Cycle 167A which were measure by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurement Works Order.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measured Thermal and Fast Neutron Fluence Rates ATR Cycles 171A MP-2

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 171A MP-2 which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measured Thermal and Fast Neutron Fluence Rates ATR Cycles 171B AFC (Rev. 0)

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 171B which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measured Thermal and Fast Neutron Fluence Rates ATR Cycles 171B ATF (Rev. 0)

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 171B which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measured Thermal and Fast Neutron Fluence Rates ATR Cycles 171A MP-2 (Rev. 1)

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 171A MP-2 which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measured Thernal and Fast Neutron Fluence Rates ATR Cycles 171B MP-2 (Rev. 0)

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 171B which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Methods for Continuously Resolving Spectral Shifts in Distributed Optical Fiber Sensors Irradiated to Extreme Neutron Fluence

Optical frequency domain reflectometry (OFDR) is a technique for interrogating distributed optical fiber sensors (DOFS) and involves correlating changes in the Rayleigh backscatter fingerprint for a fiber under test (FUT) with a reference measurement. Recently, under the WIRE-21 experiment sponsored by Nuclear Science User Facilities (NSUF) and performed at the High-Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL), silica optical fibers were irradiated to a fast neutron fluence of 1x10^21 n/cm^2/s at temperatures from 200--400 C. As in the cases of high-temperature and high-strain conditions, such high levels of neutron bombardment result in a highly dynamic RBS that evades analysis with conventional methods. This work describes the further development and application of graphical signal processing techniques applied to OFDR-based distributed optical fiber sensors specifically deployed in in-pile applications. While the signal processing techniques developed in this work are applied to DOFS in nuclear environments, they provide a general framework for the analysis of OFDR measurements and a tangible method to yield higher quality data, without imposing additional hardware requirements.

Sweeney, Dan↗

ARC-DPA 1-MeV Neutron Fluence Equivalence Model for GaAs

Here, the legacy data used in the production of the American Society for Testing and Materials (ASTM) E722 standard for gallium arsenide (GaAs) were fit with the athermal recombination corrected-displacements per atom (ARC-DPA) model for the development of a novel 1-MeV neutron equivalent fluence metric. Improving on previous work, the coefficients for the ARC-DPA model were optimized using a conjugate gradient method, and the uncertainties in the observed damage in different benchmark neutron fields were sampled to quantify their contribution to the damage metric. The optimized parameters of −0.474 ± 0.03 for b arcdpa and 0.016 ± 0.002 for c arcdpa provided good agreement and indicated that the solution is not sensitive to the corresponding fluence uncertainties. Compared to the current 1-MeV neutron fluence equivalence standard for displacement damage in GaAs, our results indicate that for a thermal reactor neutron environment, displacement damage has been underestimated by around 25% and that the saturation value for the damage efficiency had been higher than previously modeled.

1-MeV equivalent fluence↗

Improving to the neutron fluence rate monitor measurement system at the Advanced Test Reactor [Poster]

The existing fluence monitor wire scanning system at the Advanced Test Reactor (ATR) was designed and installed for use in the Engineering Test Reactor (ETR) when it began operation in 1958. The wire scanner was operated in ETR for over 20 years until ATR began operation, when it was moved to the ATR west canal area in 1971 and subsequently moved to the west canal in 2006 where it presently resides. With a continued service life of 65 years the system is well beyond the typical design life of 20 years for these types of systems. The need to update the data acquisition and control system was identified, and the benefits of replacing the existing sodium iodide (NaI) detector with an electronically cooled high-purity germanium (HPGe) detector are discussed. The wirescanner system in the ATR canal is utilized after every reactor cycle by the ATR Radiation Measurements Laboratory (RML) to assess the activation of cobalt and nickel dosimeter wires during the cycle. These wires become activated through exposure to thermal and fast neutrons respectively during the irradiation cycle and are highly radioactive upon shutdown. It is for this reason that the wirescanner is used in the ATR canal rather than transporting the dosimeters to another facility. A scoping study was performed to develop a base-line design to ensure that existing capabilities could be replaced with a new system. The new hardware will enable automated measuring of several flux monitor holders without necessitating the removal of the flux wires. In this way, flux wire measurements will be performed with minimal dose to the technicians and will not be limited by canal operations as is presently the case. The new control and acquisition software will be based on commercially available and supported systems that have a wide user-base to provide long-term stability. An electronically cooled HPGe detector will be used to provide high-resolution gamma-ray measurements, an improvement from the low-resolution sodium-iodide detector that is presently deployed. The electronic cooler eliminates the need for liquid nitrogen to cool the detector head. A new collimator has been designed to house the new detector and allow for sufficient counting rates.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improving to the neutron fluence rate monitor measurement system at the Advanced Test Reactor

The existing fluence monitor wire scanning system at the Advanced Test Reactor (ATR) was designed and installed for use in the Engineering Test Reactor (ETR) when it began operation in 1958. The wire scanner was operated in ETR for over 20 years until ATR began operation, when it was moved to the ATR west canal area in 1971 and subsequently moved to the west canal in 2006 where it presently resides. With a continued service life of 65 years the system is well beyond the typical design life of 20 years for these types of systems. The need to update the data acquisition and control system was identified, and the benefits of replacing the existing sodium iodide (NaI) detector with an electronically cooled high-purity germanium (HPGe) detector are discussed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Developing “inverted-corona” fusion targets as high-fluence neutron sources

We present experimental studies of inverted-corona targets as neutron sources at the OMEGA Laser Facility and the National Ignition Facility (NIF). Laser beams are directed onto the inner walls of a capsule via laser-entrance holes (LEHs), heating the target interior to fusion conditions. The fusion fuel is provided either as a wall liner, e.g., deuterated plastic (CD), or as a gas fill, e.g., D 2 gas. Such targets are robust to low-mode drive asymmetries, allowing for single-sided laser drive. On OMEGA, 1.8-mm-diameter targets with either a 10-μm CD liner or up to 2 atm of D 2 -gas fill were driven with up to 18 kJ of laser energy in a 1-ns square pulse. Neutron yields of up to 1.5 × 1010 generally followed expected trends with fill pressure or laser energy, although the data imply some mix of the CH wall into the fusion fuel for either design. Comparable performance was observed with single-sided (1x LEH) or double-sided (2x LEH) drive. NIF experiments tested the platform at scaled up dimensions and energies, combining a 15-μm CD liner and a 3-atm D2-gas fill in a 4.5-mm diameter target, laser-driven with up to 330 kJ. Neutron yields up to 2.6 × 10 12 were measured, exceeding the scaled yield expectation from the OMEGA data. The observed energy scaling on the NIF implies that the neutron production is gas dominated, suggesting a performance boost from using deuterium–tritium (DT) gas. In this work, we estimate that neutron yields exceeding 10 14 should be readily achievable using a modest laser drive of ~300 kJ with a DT fill.

47 OTHER INSTRUMENTATION↗

High Fluence 14 MeV Neutron Exposure Capability at the National Ignition Facility

Neutron experiments conducted at the National Ignition Facility can utilize high neutron fluences delivered in very short pulses. By adapting inertial confinement fusion laser pulses and targets, fluences above 10 15 n/cm 2 can be achieved on small experimental volumes, and prospectively up to 10 16 n/cm 2 onto capsule materials under development. Neutron pulse lengths are less than 1 ns. Large experimental volumes from 150 cm 3 to 20 L can access fluences of 10 8 -10 13 n/cm 2 . Experimental platforms may contain encapsulated hazardous materials, active electronics connected to sophisticated prompt read-out equipment, and large assemblies up to 200 kg. Furthermore, sources are designed to maximize total yield, total experimental fluence, or maximum fluenceper user-day allocated as required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MEASUREMENT OF THE NEUTRON FLUENCE-RATES IN THE ADVANCED TEST REACTOR

The axial neutron fluence-rate distribution at the Advanced Test Reactor (ATR) is determined using a combination of pure nickel and cobalt-aluminium alloy dosimeter wires. Most irradiation programs at ATR need to know the fast neutron fluence-rate surrounding their experiment to correlate post-irradiation examination results with neutron dose. The activated dosimeter wires, which extend beyond the full fuelled region of the reactor core, are highly radioactive following the full cycle in ATR and must therefore be measured in the ATR canal. The system that is employed for these measurements is mechanical scanning mechanism is used to scan the activated wires across the face of a columnated shield and a NaI detector. This detector is not sufficiently calibrated to provide absolute activity measurements, therefore, the count-rate is recorded and normalized to the highest activity for that wire. Then, an approximately 3-mm long portion of the wire is removed from the highest activity region in the wire. The wires are then transferred, and an absolute activity measurement is made using a calibrated ionization chamber. These measurements are combined with corrections for decay, neutron energy spectrum, burnup, dosimeter composition, reactor power fluctuations, and reactor outages to determine the average axial neutron fluence-rate at various locations within ATR during the cycle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗