SEARCH · Search NASA
Results for “NSLS”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
NIST HAXPES at NSLS and NSLS-II
Explore the source record for details and available documents.
Development of Synchrotron Footprinting at NSLS and NSLS-II
Explore the source record for details and available documents.
Sandia National Laboratories / NIST Collaboration at NSLS / NSLS II.
Abstract not provided.
Magnetic Characterization and Tuning of a Mini-Gap In-Vacuum Undulator X25 for NSLS-II
Designed and built by ADC USA Inc. a Mini-Gap In-Vacuum Undulator (MGU X25) has been employed for almost 10 years at NSLS in the Macromolecular Crystallography X25 beamline [1]. The device is a useful and almost readily available X-ray source for NLSL-II beamline, therefore it was extracted in early 2014 from the NSLS X-ray ring after its decommissioning. The Micro-diffraction beamline (NYX) at NSLS-II will utilize the X25-MGU as a bright and tunable X-ray source over the photon range of 5- 20 KeV in the short cell 19-ID. However, the NSLS-II electron beam properties are significantly different from the NSLS ones and the field integral requirements to be met by NSLS-II IDs are more stringent. Consequently, the device was brought to the NSLS-II ID lab for magnetic tuning. It is also a unique opportunity to characterize the magnetic performance of an ID after 10 years of operation in a storage ring.
Development of the XFP beamline for x-ray footprinting at NSLS-II
For over a decade, synchrotron-based footprinting studies at the NSLS X28C beamline have provided unique insights and approaches for examining the solution-state structures of large macromolecular assemblies, membrane proteins, and soluble proteins, for time-resolved studies of macromolecular dynamics, and most recently for in vivo studies of RNA-protein complexes. The transition from NSLS to NSLS-II has provided the opportunity to create an upgraded facility for the study of increasingly complex systems; progress on the development of the XFP (X-ray Footprinting for In Vitro and In Vivo Structural Studies of Biological Macromolecules) beamline at NSLS-II is presented here. The XFP beamline will utilize a focused 3-pole wiggler source to deliver a high flux density x-ray beam, where dynamics can be studied on the microsecond to millisecond timescales appropriate for probing biological macromolecules while minimizing sample perturbation. The beamline optics and diagnostics enable adaptation of the beam size and shape to accommodate a variety of sample morphologies with accurate measurement of the incident beam, and the upgrades in sample handling and environment control will allow study of highly sensitive or unstable samples. The XFP beamline is expected to enhance relevant flux densities more than an order of magnitude from that previously available at X28C, allowing static and time-resolved structural analysis of highly complex samples that have previously pushed the boundaries of x-ray footprinting technology. XFP, located at NSLS-II 17-BM, is anticipated to become available for users in 2016.
Characterizing Hidden Structures at NSLS-II: Strongly Correlated Electron Systems, Functional Ceramics, Batteries, and Beyond
Brookhaven National Laboratory (New York) launched its highenergy X-ray science program at the inception of the National Synchrotron Light Source (NSLS), a U.S. Department of Energy (DOE) Office of Science User Facility. Built in the 1980s, the NSLS X17 beamline was the world’s first super-conducting wiggler facility and remained in service for more than 30 years. The NSLS facility was decommissioned in October 2014 and a third-generation synchrotron machine, DOE’s National Synchrotron Light Source II (NSLS-II), took over. Six years after completing construction, NSLS-II has a portfolio of 29 beamlines that includes two operating high-energy powder diffraction beamlines (XPD and PDF) and one high-energy imaging and diffraction beamline under construction (HEX).
Individual NSLS-II Multipole Magnet Alignment by Laser Trackers
The magnet alignment of the 90 th and final multipole girder assembly was completed January 17 th , 2013. Our procedure of “rough” pre-alignment by laser trackers and final alignment by vibrating wire & “Differential Variable Reluctance Transducers” (DVRT) has been quite successful, achieving magnet to magnet alignment well under the 30 micron specification. The pre-alignment accuracy is verified by the initial scan from the vibrating wire. The alignment residuals can be calculated from the offsets of a best fit line. The results are impressive, especially considering the environment of the Building 902 Annex (which has a large bay door that would open during pre-alignment, without fail), the sloppiness of the magnets’ fiducials, and especially the fact that the girders were pre-aligned to their mechanical centers, but the vibrating wire reports the magnetic centers which may be considerably different. This result hints at the potential feasibility of alignment with laser trackers for replacement magnets of NSLS-II and maybe even all magnets of future accelerators. But, it is difficult to predict the achievable accuracy until the main three error sources (a.k.a. Survey group excuses) are eliminated: measuring environment, bad magnet fiducials, and mechanical/magnetic center differences. The test performed on a large aperture quadrupole on girder assembly C19G4 was designed to answer the following questions with the aforementioned error sources either eliminated or simulated: 1) How accurately can a NSLS-II multipole be realigned after repair or other disturbance given the existing fiducials? 2) How accurately can a replacement NSLS-II multipole be installed in situ if its magnetic center is known relative to good fiducials? 3) If the current NSLS-II spares are never magnetically fiducialized, how well can they be installed using only mechanical data? 4) Could the magnets of a future accelerator (with similar alignment specifications as NSLS-II) be aligned using commercially available metrology instruments? This paper will answer these questions.
A Fast, Versatile Nanoprobe for Complex Materials: The Sub-micron Resolution X-ray Spectroscopy Beamline at NSLS-II (491st Brookhaven Lecture)
Time is money and for scientists who need to collect data at research facilities like Brookhaven Lab’s National Synchrotron Light Source (NSLS), “beamtime” can be a precious commodity. While scanning a complex material with a specific technique and standard equipment today would take days to complete, researchers preparing to use brighter x-rays and the new sub-micron-resolution x-ray spectroscopy (SRX) beamline at the National Synchrotron Light Source II (NSLS-II) could scan the same sample in greater detail with just a few hours of beamtime. Talk about savings and new opportunities for researchers! Users will rely on these tools for locating trace elements in contaminated soils, developing processes for nanoparticles to deliver medical treatments, and much more. Dr. Thieme explains benefits for next-generation research with spectroscopy and more intense x-rays at NSLS-II. He discusses the instrumentation, features, and uses for the new SRX beamline, highlighting its speed, adjustability, and versatility for probing samples ranging in size from millimeters down to the nanoscale. He will talk about complementary beamlines being developed for additional capabilities at NSLS-II as well.
NSLS-II longitudinal impedance budget
From the beginning of the NSLS-II project, the vacuum chamber of the NSLS-II storage ring has been optimized to reduce its impedance. The optimization, performed in close collaboration with the Diagnostic, Vacuum, RF, and Mechanical Engineering groups, has been achieved via calculating the impedance of the vacuum chamber components with the use of both analytical and numerical tools, with the numerical computations carried out with the GdfidL code. Fore reliable NSLS-II operation with the total beam current of 500 mA, each component of the vacuum chamber has been individually optimized to minimize the beam-induced heating and to prevent single-bunch and coupled-bunch instabilities. In this study, the impedance calculation and optimization know-how are summarized for all the chamber components, and the total longitudinal impedance budget is analyzed. As a result of this extensive research and engineering effort, the design beam current of 500 mA has been recently accumulated in NSLS-II without any major problem caused by collective effects.
NSLS-II Booster Survey and Alignment Systems
This section outlines the survey and alignment requirements and the technology and tools for achieving the NSLS-II equipment positioning goals. The required alignment tolerances are defined primarily by the physics requirements of the accelerator. The tight tolerances dictated by the physics requirements are an order of magnitude tighter than the tolerances of second generation light sources (NSLS) and on level with those at third generation light sources (Soleil, Diamond). These extraordinary position requirements necessitate a concerted R&D engineering effort to identify and develop the survey methodology needed to meet these requirements. As of this date, the methodology is still evolving to balance cost and time constraints while still maintaining the integrity of the survey and alignment systems. State-of-the art equipment including Laser Trackers and Laser Arms have been purchased and used extensively in the pursuit of meeting the NSLS-II survey tolerances. No new technology will need to be developed to meet the alignment requirements but new techniques will be pursued and developed. Survey and alignment provides the foundation for positioning the beam-guiding magnet structures in all 6 degrees of freedom within the required tolerances. Although the tools and instrumentation available for this task have changed over the years and faster and more accurate measurements are possible, only limited control of the environmental conditions is possible. This ultimately sets an upper limit for the achievable measurement and subsequent control network accuracy. At the same time, the control of environmental variables (temperature, humidity) will be fully taken advantage of during the building of NSLS-II , opening up the possibility of ever-increasing accuracy unheard of only five years ago.
Merging Dog-leg for Including the Second Gun in the NSLS-II Linear Accelerator
The low-energy part of the NSLS-II linear accelerator begins with the 100-keV gun, which is the key component for the injector performance. The gun electronics determine the generated bunch patterns, emittance, energy spread and charge transport efficiency in the low-energy part of the injector. We proposed to include a second gun to the NSLS-II linac. This upgrade will: a) increase reliability of the NSLS-II accelerator complex and, b) enable more efficient operations in generating complex bunch patterns. The latter is critical since for supporting complex bunch patterns the same gun must be able to switch robustly between single- and multi-bunch modes within the time interval between the top-off cycles. Including the 2nd gun, operating exclusively in the single-bunch mode, would greatly simplify switching between the modes as well as reduce beam charge losses. We designed the NSLS-II linac tunnel so there is a small extra room for the second gun that we proposed to introduce into the main linac via a short dog-leg. To minimize the additional space the dog-leg must be very short and parameters of the dog-leg optical components must stay within reasonable field and gradient values.
Accelerator Physics at NSLS-II: Research Accomplishments in 2018
Scientific support for user operations is the main mission of the NSLS-II Accelerator Physics group. At the same time, NSLS-II accelerator physicists were working in 2018 on the following research and development projects: development of HLA common tools for beam studies and operations; online optimization of Injector and Storage Ring (Facility Improvement Project); development of a new operation mode for timeresolved experiments; high-brightness upgrade options for NSLS-II; ultra-fast electron diffraction (LDRD); APS upgrade project and the electron-ion collider project at BNL (MOUs). A summary of the research accomplishments of the NSLS-II Accelerator Physics group is presented in this report.
Accelerator Physics at NSLS-II: Research Accomplishments in 2024
NSLS-II accelerator physicists advanced the operational performance and scientific capabilities of NSLS-II, providing regular lattice characterization and correction, injec tion optimization, vertical emittance control, and beam dynamics reports with corre lation analysis. We further developed advanced lattice characterization techniques and studies on impedance, beam-induced heating, and higher-harmonic RF cavity effects to support NSLS-II and its high-brightness upgrade. The assessment of free-electron laser options for the NSLS-II upgrade has been completed. We carried out comprehensive studies focused on complex bend magnets and novel efficient injection schemes for next-generation low-emittance synchrotrons. We contributed to the Electron-Ion Collider project, including Electron Storage Ring lattice design, beam diagnostics, and injector studies. The physicists participated in international collaborations, including the development of Python-based Middle Layer software, and participated in key accel erator physics workshops and scientific meetings. The main research accomplishments achieved in 2024 are summarized in this report.
ANALYSIS OF NSLS-II TOUSCHEK LIFETIME
As scrapers are adopted for the loss control of NSLS-II storage ring, Touschek lifetime estimations for various cases are required to assure the stable operation. However, to estimate the Touschek lifetime, momentum apertures should be measured all along the ring and, if we want to estimate the lifetime in various situations, it can take extremely long time. Thus, rather than simulating for each case, a semi-analytic methods with the interpolations are used for the measurements of the momentum apertures. In this paper, we described the methods and showed the results. Having enough Touschek lifetime is important for synchrotron light source for the users to perform experiments with stable beams. In NSLS-II, the scrapers will be installed for the loss control. Especially, the horizontal scrapers will be installed where the dispersions are maximum. Therefore, we need to find the proper scraper gap values which do not reduce the lifetime too much for the stable beam operation. To estimate reliable Touschek lifetime, we should measure the momentum apertures at many positions along the ring. For the rough estimation of the Touschek lifetime, the RF momentum acceptance can be used and for a more detailed estimation, the linear approximation of synchrotron oscillation can be used. However, for the strong focussing synchrotrons, like NSLS-II, the linear approximation is not enough to obtain the reliable momentum apertures, and, in general, particle tracking simulations are used. However, for NSLS-II case, we need to track the particle about 400 turns at each point to make it a full synchrotron oscillation period and to obtain the reliable Touschek lifetime we need measure the momentum apertures at several hundred positions at least. Therefore, it can take quite a long time if we want to have the reasonable resolution for the measurements. Furthermore, at the simulation, if we want to measure the aperture inside a element, we should divide the element and this will make the simulation longer. Here, we developed a systematic method to calculate the momentum aperture using interpolation tables. Once the tables are prepared, the precise momentum aperture can be calculated instantly at arbitrary position for various situations.
SIMULATIONS OF TRANSVERSE STACKING IN THE NSLS-II BOOSTER
The NSLS-II injection system consists of a 200 MeV linac and a 3 GeV booster. The linac needs to deliver 15 nC in 80 - 150 bunches to the booster every minute to achieve current stability goals in the storage ring. This is a very stringent requirement that has not been demonstrated at an operating light source. We have developed a scheme to transversely stack two bunch trains in the NSLS-II booster in order to alleviate the charge requirements on the linac. This scheme has been outlined previously. In this paper we show particle tracking simulations of the tracking scheme. We show simulations of the booster ramp with a stacked beam for a variety of lattice errors and injected beam parameters. In all cases the performance of the proposed stacking method is sufficient to reduce the required charge from the linac. For this reason the injection system of the NSLS-II booster is being designed to include this feature. The NSLS-II injection system consists of a 200 MeV linac and a 3 GeV booster. The injectors must provide 7.5nC in bunch trains 80-150 bunches long every minute for top off operation of the storage ring. Top off then requires that the linac deliver 15nC of charge once losses in the injector chain are taken into consideration. This is a very stringent requirement that has not been demonstrated at an operating light source. For this reason we have developed a method to transversely stack two bunch trains in the booster while maintaining the charge transport efficiency. This stacking scheme has been discussed previously. In this paper we show the simulations of the booster ramp with a single bunch train in the booster. Then we give a brief overview of the stacking scheme. Following, we show the results of stacking two bunch trains in the booster with varying beam emittances and train separations. The behavior of the beam through the ramp is examined showing that it is possible to stack two bunch trains in the booster.
NSLS-II RF BEAM POSITION MONITOR
An internal R&D program has been undertaken at BNL to develop a sub-micron RF Beam Position Monitor (BPM) for the NSLS-II 3rd generation light source that is currently under construction. The BPM R&D program started in August 2009. Successful beam tests were conducted 15 months from the start of the program. The NSLS-II RF BPM has been designed to meet all requirements for the NSLS-II Injection system and Storage Ring. Housing of the RF BPM's in +-0.1 C thermally controlled racks provide sub-micron stabilization without active correction. An active pilot-tone has been incorporated to aid long-term (8hr min) stabilization to 200nm RMS. The development of a sub-micron BPM for the NSLS-II has successfully demonstrated performance and stability. Pilot Tone calibration combiner and RF synthesizer has been implemented and algorithm development is underway. The program is currently on schedule to start production development of 60 Injection BPM's starting in the Fall of 2011. The production of {approx}250 Storage Ring BPM's will overlap the Injection schedule.
Rogue Mode Shileding in NSLS-II Multipole Vacuum Chambers
Modes with transverse electric field (TE-modes) in the NSLS-II multipole vacuum chamber can be generated at frequencies above 450MHz due to its geometric dimensions. Since the NSLS-II BPM system monitors signals within 10 MHz band at RF frequency of 500 MHz, frequencies of higher-order modes (HOM) can be generated within the transmission band of the band pass filter. In order to avoid systematic errors in the NSLS-II BPM system, we introduced frequency shift of HOMs by using RF metal shielding located in the antechamber slot. We demonstrated numerical modeling and experimental studies of the spurious TE modes in the NSLS-II vacuum chambers with antechamber slot. Calculated frequencies of TE-modes in considered chambers with and without RF shielding were verified experimentally. Flexible BeCu RF shielding inside each chamber at proper location shifts frequencies of H{sub 10p}-modes above {approx}900MHz, except chambers S6 odd and even. These chambers need special attention because of synchrotron radiation from downstream magnets. S6 odd multipole vacuum chamber needs to be measured and the RF shielding length has to be optimized. RF shielding looks adequate for baseline design. Fifty percent of open space provides adequate pumping speed.