Search NASA⌕ Search

SEARCH · Search NASA

Results for “NVR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Investigation of Cleanliness Verification Techniques for Rocket Engine Hardware

Oxidizer propellant systems for liquid-fueled rocket engines must meet stringent cleanliness requirements for particulate and nonvolatile residue. These requirements were established to limit residual contaminants which could block small orifices or ignite in the oxidizer system during engine operation. Limiting organic residues in high pressure oxygen systems, such as in the Space Shuttle Main Engine (SSME), is particularly important. The current method of cleanliness verification for the SSME uses an organic solvent flush of the critical hardware surfaces. The solvent is filtered and analyzed for particulate matter followed by gravimetric determination of the nonvolatile residue (NVR) content of the filtered solvent. The organic solvents currently specified for use (1, 1, 1-trichloroethane and CFC-113) are ozone-depleting chemicals slated for elimination by December 1995. A test program is in progress to evaluate alternative methods for cleanliness verification that do not require the use of ozone-depleting chemicals and that minimize or eliminate the use of solvents regulated as hazardous air pollutants or smog precursors. Initial results from the laboratory test program to evaluate aqueous-based methods and organic solvent flush methods for NVR verification are provided and compared with results obtained using the current method. Evaluation of the alternative methods was conducted using a range of contaminants encountered in the manufacture of rocket engine hardware.

Fritzemeier, Marilyn L.↗

Chemical Aging of Environmentally Friendly Cleaners

Use of cleaners in the manufacturing area demands bottles that will hold a sufficient amount of material and allow for easy and controlled dispensing by the operator without contamination or material leaching from the bottle. The manufacturing storage conditions are also a factor that may affect cleaner chemical integrity and its potential to leave a residue on the part. A variety of squeeze bottles stored in mild (72 F, 10% R.H., dark) and harsh (105 F, 50% R.H., fluorescent lighting) conditions were evaluated to determine the effect of environment and bottle exposure on ozone depleting chemicals (ODC) cleaners chemical composition. Low Density Polyethylene (LDPE) bottles were found to be quite permeable to all the cleaners evaluated in this study indicating this bottle type should not be used in the manufacturing area. Fluorinated Polyethylene (FLPE) bottles showed little cleaner loss and change in cleaner chemical composition over time suggesting these bottles would be acceptable for use. Chemical analysis indicates limonene containing cleaners show increased non-volatile residue (NVR) content with storage under harsh conditions. Some cleaners use BHT (butylated hydroxytoluene) as stabilizer and to protect against limonene oxidation. Under harsh conditions, BHT was quickly depleted resulting in higher NVR levels.

Biegert, L. L.↗

Improved Detection Technique for Solvent Rinse Cleanliness Verification

The NASA White Sands Test Facility (WSTF) has an ongoing effort to reduce or eliminate usage of cleaning solvents such as CFC-113 and its replacements. These solvents are used in the final clean and cleanliness verification processes for flight and ground support hardware, especially for oxygen systems where organic contaminants can pose an ignition hazard. For the final cleanliness verification in the standard process, the equivalent of one square foot of surface area of parts is rinsed with the solvent, and the final 100 mL of the rinse is captured. The amount of nonvolatile residue (NVR) in the solvent is determined by weight after the evaporation of the solvent. An improved process of sampling this rinse, developed at WSTF, requires evaporation of less than 2 mL of the solvent to make the cleanliness verification. Small amounts of the solvent are evaporated in a clean stainless steel cup, and the cleanliness of the stainless steel cup is measured using a commercially available surface quality monitor. The effectiveness of this new cleanliness verification technique was compared to the accepted NVR sampling procedures. Testing with known contaminants in solution, such as hydraulic fluid, fluorinated lubricants, and cutting and lubricating oils, was performed to establish a correlation between amount in solution and the process response. This report presents the approach and results and discusses the issues in establishing the surface quality monitor-based cleanliness verification.

Hornung, S. D.↗

Chemical Aging of Environmentally Friendly Cleaners

Use of cleaners in the manufacturing area demands bottles that will hold a sufficient amount of material and allow for easy and controlled dispensing by the operator without contamination or material leaching from the bottle. The manufacturing storage conditions are also a factor that may affect cleaner chemical integrity and its potential to leave a residue on the part. A variety of squeeze bottles stored in mild (72 F, 10 % R.H., dark) and harsh (105 F, 50 % R.H., fluorescent lighting) conditions were evaluated to determine the effect of environment and bottle exposure on the chemical composition of TCA (1,1,1 trichloroethane) replacement solvents. Low Density Polyethylene (LDPE) bottles were found to be quite permeable to all the cleaners evaluated in this study indicating this bottle type should not be used in the manufacturing area. Fluorinated Polyethylene (FLPE) bottles showed little cleaner loss and change in cleaner chemical composition over time suggesting these bottles would be acceptable for use. Chemical analysis indicates limonene-containing cleaners show increased non-volatile residue (NVR) content with storage under harsh conditions. Some cleaners use BHT (butylated hydroxytoluene) as stabilizer and to protect against limonene oxidation. Under harsh conditions, BHT was quickly depleted resulting in higher NVR levels.

Evans, K.↗

Cleanroom Contaminant Monitor

Under a Small Business Innovation Research (SBIR) contract from Kennedy Space Center (KSC), Femtometrics, Inc. developed the Real-Time Non-Volatile Residue (NVR) monitor. Criteria established by KSC called for a technology that could regulate the accumulation of nonvolatile residues in cleanroom environments. The company accommodated the Center's need with an advanced, highly sensitive surface acoustic wave (SAW) microsensor capable of detecting sub-monolayer deposition in cleanrooms where aerospace systems are assembled. Years earlier, Femtometrics responded to and received SBIR contracts from Langley Research Center for highly sensitive aerosol detectors for environmental researchers. Stimulated by the SBIR wins, the company set about to develop the SAW resonator technology. A new type of sensor has evolved from the research, one that has the ability to measure a range of chemical vapors by applying chemical-specific coating on the sensing surface. Commercial applications of the Real-Time NVR include Class 1 cleanrooms at semiconductor and hard-disk manufacturing plants.

Source record↗

Precision Cleaning of Oxygen Systems and Components

Currently, NASA uses Dichloropentafluoropropane (HCFC-225), a Class II ozone depleting substance (ODs), to clean contaminated oxygen systems. Starting in 20 15, the Montreal Protocols and Clean Air Act prohibit the production and importation of all hydrochlorofluorocarbons (HCFC), except for limited use in refrigeration applications. Thus, a new non-ozone depleting solvent needs to be developed for use in cleaning. Optimally, such a solvent should also be environmentally benign or green to avoid needing to replace the new solvent with yet another solvent in the future due to other environmental concerns. Work for the first year consisted of two parts. The first part was developing a method of testing the cleaning efficiency of potential solvents. Stainless steel coupons were contaminated with a known weight of various contaminants and contaminant combinations and then immersed in solvent for ten minutes. The coupons were then removed and dried in an oven until all solvent had evaporated. Once dry, the coupons were weighed and the mass of the non-volatile residue (NVR) left on the coupon was determined. The cleaning efficiency of the solvents is reported as percent cleaning, with 100% cleaning being zero NVR left on the test coupon. The second half of the first goal was to use the develop method to perform baseline testing on current solvents. The second part of the work was to begin exploring alternative cleaning solvents. A variety of hydrofluorocarbons (HFCs) were tested. Preliminary testing was also performed with ionic liquids and aqueous surfactant solutions. Once potential solvents were identified, an analysis of the performance and environmental characteristics of each was to be conducted. Four contaminants were specified for use in testing. These are Mil-Spec-H-5606 (5606), a hydraulic fluid, Mil-H-83282B (83282), another hydraulic fluid, diethylhexyl sebacate (Sebacate), and WD-40. The structures of these contaminants are all similar, with long aliphatic hydrocarbon chains of lengths between fifteen and fifty. Contaminants were tested both individually and in combination. All combinations were done with equal weights of the constituent contaminants.

McLaughlin, Russell↗

Solvent residue content measured by light scattering technique

Photometric analyzer measures NVR /nonvolatile residue/ in trichloroethylene and other organic solvents. The analyzer converts the liquid solvent to aerosol and passes it between an optically focused light beam and a photodetector that is connected to standard amplifying and readout equipment.

Salkowski, M. J.↗

Using a temperature-controlled quartz crystal microbalance in a space equipment cleanroom to monitor molecular contamination

There is a need for continuous monitoring for molecular contamination in clean rooms where spaceflight equipment is assembled, integrated, and tested to insure that contamination budgets are met. The TQCM (temperature-controlled quartz crystal microbalance) can be used to provide both a real time warning and a cumulative measurement of molecular contamination. It has advantages over the other measurement methods such as witness mirrors, NVR (non-volatile residue) plates, and gas analyzers. A comparison of the TQCM sensitivity and ease of operations is made with the other methods. The surface acoustic wave microbalance (SAW), a newly developed instrument similar to TQCM, is considered in the comparison. An example is provided of TQCM use at Goddard Space Flight Center when the Wide Field Planetary Camera 2(WFPC-2) and the Corrective Optics Space Telescope Axial Replacement (COSTAR) were undergoing integrated testing prior to their installation in the Hubble Space Telescope on its first servicing mission. Areas for further investigation are presented.

Mitchell, William J.↗

Aqueous cleaning and verification processes for precision cleaning of small parts

The NASA Kennedy Space Center (KSC) Materials Science Laboratory (MSL) has developed a totally aqueous process for precision cleaning and verification of small components. In 1990 the Precision Cleaning Facility at KSC used approximately 228,000 kg (500,000 lbs) of chlorofluorocarbon (CFC) 113 in the cleaning operations. It is estimated that current CFC 113 usage has been reduced by 75 percent and it is projected that a 90 percent reduction will be achieved by the end of calendar year 1994. The cleaning process developed utilizes aqueous degreasers, aqueous surfactants, and ultrasonics in the cleaning operation and an aqueous surfactant, ultrasonics, and Total Organic Carbon Analyzer (TOCA) in the nonvolatile residue (NVR) and particulate analysis for verification of cleanliness. The cleaning and verification process is presented in its entirety, with comparison to the CFC 113 cleaning and verification process, including economic and labor costs/savings.

Allen, Gale J.↗

Cleaning verification by air/water impingement

This paper will discuss how the Kennedy Space Center intends to perform precision cleaning verification by Air/Water Impingement in lieu of chlorofluorocarbon-113 gravimetric nonvolatile residue analysis (NVR). Test results will be given that demonstrate the effectiveness of the Air/Water system. A brief discussion of the Total Carbon method via the use of a high temperature combustion analyzer will also be given. The necessary equipment for impingement will be shown along with other possible applications of this technology.

Jones, Lisa L.↗

Aqueous Cleaning and Validation for Space Shuttle Propulsion Hardware at the White Sands Test Facility

The NASA White Sands Test Facility (WSTF) has developed an entirely aqueous final cleaning and verification process to replace the current chlorofluorocarbon (CFC) 113 based process. This process has been accepted for final cleaning and cleanliness verification of WSTF ground support equipment. The aqueous process relies on ultrapure water at 50 C (323 K) and ultrasonic agitation for removal of organic compounds and particulate. The cleanliness is verified bv determining the total organic carbon (TOC) content and filtration with particulate counting. The effectiveness of the aqueous methods for detecting hydrocarbon contamination and particulate was compared to the accepted CFC 113 sampling procedures. Testing with known contaminants, such as hydraulic fluid and cutting and lubricating oils, to establish a correlation between aqueous TOC and CFC 113 nonvolatile residue (NVR) was performed. Particulate sampling on cleaned batches of hardware that were randomly separated and sampled by the two methods was performed. This paper presents the approach and results, and discusses the issues in establishing the equivalence of aqueous sampling to CFC 113 sampling, while describing the approach for implementing aqueous techniques on Space Shuttle Propulsion hardware.

Hornung, Steven D.↗

Aging Effects of Environmentally-Friendly Cleaners on Adhesive Bond Integrity

Because of the 1990 Clean Air Act Amendment many chlorinated solvents are being phased out of use in manufacturing industries. Replacement of the ODC (ozone- depleting chemicals) with less volatile, non-ozone depleting cleaners has been extensively studied over the past nine years at Thiokol Propulsion, Cordant Technologies. Many of the non-ODC cleaners contain compounds that can potentially degrade over time under conditions of high temperature, humidity and exposure to light. The chemical composition of environmentally conditioned cleaners and the subsequent effect on aluminum/amine-cured epoxy bond integrity as measured by Tapered Double Cantilever Beam were evaluated. From this study it is observed that moisture content increases for those cleaners containing polar compounds. Non-volatile residue content increases as stabilizers are depleted and the chemical compound limonene is oxidized. A change in aluminum/ amine-cured epoxy bond fracture toughness is observed as some of these cleaners age with increases in moisture and NVR content.

Biegert, L. L.↗

Removal of Perfluorinated Grease Components from NTO Oxidizer

Perfluorinated greases are typically used as a thread lubricant in the assembly of non-welded nitrogen tetroxide (NTO) oxidizer systems. These greases, typically a perfluoroalkylether, with suspended polytetrafluoroethylene (PTFE) micro-powder, have attractive lubricating properties toward threaded components and are relatively chemically inert toward NTO oxidizers. A major drawback, however, is that perfluoroalkylether greases are soluble or dispersible in NTO oxidizers and can contaminate the propellant. The result is propellant that fails the non-volatile residue (NVR) specification analyses and that may have negative effects on test hardware performance and lifetime. Consequently, removal of the grease contaminants from NTO may be highly desirable. Methods for the removal of perfluorinated grease components from NTO oxidizers including distillation, adsorption, filtration, and adjustment of temperature are investigated and reported in this work. Solubility or dispersibility data for the perfluoroalkylether oil (Krytox(tm)143 AC) component of a perfluorinated grease (Krytox 240 AC) and for Krytox 240 AC in NTO were determined and are reported.

McClure, Mark B.↗

Exploring Surface Analysis Techniques for the Detection of Molecular Contaminants on Spacecraft

Molecular contamination is a known area of concern for spacecraft. To mitigate this risk, projects involving space flight hardware set requirements in a contamination control plan that establishes an allocation budget for the exposure of non-volatile residues (NVR) onto critical surfaces. The purpose of this work will focus on non-contact surface analysis and in situ monitoring to mitigate molecular contamination on space flight hardware. By using Scanning Electron Microscopy and Energy Dispersive Spectroscopy (SEM-EDS) with Raman Spectroscopy, an unlikely contaminant was identified on space flight hardware. Using traditional and surface analysis methods provided the broader view of the contamination sources allowing for best fit solutions to prevent any future exposure.

Rutherford, Gugu N.↗

Evaluation of Contamination Inspection and Analysis Methods through Modeling System Performance

Contamination is usually identified as a risk on the risk register for sensitive space systems hardware. Despite detailed, time-consuming, and costly contamination control efforts during assembly, integration, and test of space systems, contaminants are still found during visual inspections of hardware. Improved methods are needed to gather information during systems integration to catch potential contamination issues earlier and manage contamination risks better. This research explores evaluation of contamination inspection and analysis methods to determine optical system sensitivity to minimum detectable molecular contamination levels based on IEST-STD-CC1246E non-volatile residue (NVR) cleanliness levels. Potential future degradation of the system is modeled given chosen modules representative of optical elements in an optical system, minimum detectable molecular contamination levels for a chosen inspection and analysis method, and determining the effect of contamination on the system. By modeling system performance based on when molecular contamination is detected during systems integration and at what cleanliness level, the decision maker can perform trades amongst different inspection and analysis methods and determine if a planned method is adequate to meet system requirements and manage contamination risk.

Seasly, Elaine↗

Oxygen Compatibility and Challenge Testing of the PLSS Variable Oxygen Regulator (VOR) for the Advanced EMU

The Variable Oxygen Regulator (VOR), a stepper actuated two-stage mechanical regulator, is being developed for the purpose of serving as the Primary Oxygen Regulator (POR) and Secondary Oxygen Regulator (SOR) within the Advanced EMU PLSS, now referred to as the xEMU and xPLSS. Three prototype designs have been fabricated and tested as part of this development. Building upon the lessons learned from the 35 years of Shuttle/ISS EMU Program operation including the fleet-wide EMU Secondary Oxygen Pack (SOP) contamination failure that occurred in 2000, the VOR is being analyzed, designed, and tested for oxygen compatibility with controlled Non-Volatile Residue (NVR) and a representative worst-case hydro-carbon system contamination event (>100mg/sq ft dodecane). This paper discusses the steps taken in testing of VOR 2.0 with for oxygen compatibility and then discusses follow-on design changes implemented in the VOR 3.0 (3rd prototype) as a result.

Campbell, Colin↗

Sample Curation in Support of the OSIRIS-REx Asteroid Sample Return Mission

The OSIRIS-REx asteroid sample return mission launched to asteroid Bennu Sept. 8, 2016. The spacecraft will arrive at Bennu in late 2019, orbit and map the asteroid, and perform a touch and go (TAG) sampling maneuver in July 2020. After sample is stowed and confirmed the spacecraft will return to Earth, and the sample return capsule (SRC) will land in Utah in September 2023. Samples will be recovered from Utah [2] and then transported and stored in a new sample cleanroom at NASA Johnson Space Center in Houston [3]. The materials curated for the mission are described here. a) Materials Archive and Witness Plate Collection: The SRC and TAGSAM were built between March 2014 and Summer of 2015, and instruments (OTES,OVIRS, OLA, OCAMS, REXIS) were integrated from Summer 2015 until May 2016. A total of 395 items were received for the materials archive at NASA-JSC, with archiving finishing ~30 days after launch (with the final archived items being related to launch operations)[4]. The materials fall into several general categories including metals (stainless steel, aluminum, titanium alloys, brass and BeCu alloy), epoxies, paints, polymers, lubricants, non-volatile-residue samples (NVR), sapphire, and various miscellaneous materials. All through the ATLO process (from March 2015 until late August 2016) contamination knowledge witness plates (Si wafer and Al foil) were deployed in the various cleanrooms in Denver and KSC to provide an additional record of particle counts and volatiles that is archived for current and future scientific studies. These plates were deployed in roughly monthly increments with each unit containing 4 Si wafers and 4 Al foils. We archived 128 individual witness plates (64 Si wafers and 64 Al foils); one of each witness plate (Si and Al) was analyzed immediately by the science team after archiving, while the remaining 3 of each are archived indefinitely. Information about each material archived is stored in an extensive database at NASA-JSC, and key summary information for each will be presented in an online catalog. b) Bulk Asteroid sample: The Touch and Go Sampling Mechanism (TAGSAM) head will contain up to 1.5 kg of asteroid material. Upon return to Earth, the TAGSAM head with the sample canister will be subjected to a nitrogen purge and then opened in a nitrogen cabinet in Houston. Once the TAGSAM head is removed from the canister, it will be dis-assembled slowly and carefully under nitrogen until the sample can be removed for processing in a dedicated nitrogen glovebox. Bennu surface samples are expected to be sub-cm sized, based on thermal infrared and radar polarization ratio measurements [1]. The upper limit on material collected by the TAGSAM head is ~2 cm. Therefore, we will be prepared to handle, subdivide, and characterize materials of a wide grain size (from ~10 m to 2 cm), and for both organic (UV fluorescence) and inorganic (SEM, FTIR, optical) properties. Representative portions of the bulk sample will be prepared for JAXA (0.5 %; see also [5]) and Canadian Space Agency (4%), with the remaining divided between the science team (<25%) and archived for future studies (NASA) (>75%). c) Contact Pad samples: The base of the TAGSAM head contains 24 contact pads that are designed to trap the upper surface layer of material and thus offer an opportunity to study asteroid samples that have resided at the very top surface of the regolith. Asteroid material is trapped on the pads in spring steel Velcro hooks, and material will have to be removed from these pads by curation specialists in the lab. d) Hardware: Some canister and SRC hardware items will contain information that will be important to understanding the collected samples, including the canister gas filter, temperature strips, flight witness plates, and the TAGSAM and canister parts that might have adhering dust grains. Some challenges remaining for both bulk sample and contact pad samples include: i) working with intermediate size range (200 to 500 micron) samples - a size range NASA has not previously worked in such detail; ii) techniques for removal of contact pad material from the spring steel hooks, iii) static electrical effects of dust sized particles during sample handling and curation is likely to be significant, and iv) the TAGSAM head and associated canister hardware will undoubtedly be coated with fine adhering dust grains from Bennu. In the case of collection of a large bulk sample mass, the adhering dust grains may be of lower priority. If a small sample mass is returned, the adhering dust may attain a higher priority, so recovery of adhering dust grains is an additional challenge to consider. In the year leading up to sample return we plan a variety of sample handling rehearsals that will enables the curation team to be prepared for many new aspects posed by this sample suite.

Righter, Kevin↗

Solvent Replacement for Hydrochlorofluorocarbon-225 for Cleaning Oxygen System Components

This Technical Memorandum is the result of a 2-year project funded by the Defense Logistics Agency-Aviation, Hazardous Minimization and Green Products Branch, to identify and test two candidate solvents to replace hydrochlorofluorocarbon-225 (HCFC-225) for cleaning oxygen systems. The solvents were also compared to a second solvent composed predominantly of perfluorobutyl iodide (PFBI), which had received limited approval by the United States Air Force (USAF) for hand wipe cleaning of components for aviators’ breathing oxygen systems. The tests performed for this study were based on those reported in AFRL-ML-WP-TR-2003-4040, “The Wipe Solvent Program,” the test program used to qualify Ikon® Solvent P for USAF applications.The study was completed in August 2014, prior to the completion of a more extensive study funded by the NASA Rocket Propulsion Test (RPT) program. The results of the RPT project are reported in NASA/TP-2015-18207, “Replacement of Hydrochlorofluorocarbon–225 Solvent for Cleaning and Verification Sampling of NASA Propulsion Oxygen Systems Hardware, Ground Support Equipment, and Associated Test Systems.” The test methods used in this study for nonvolatile residue (NVR) background, materials compatibility, and cleaning effectiveness were different than those used for the RPT project; a smaller set of materials and contaminants were tested. The tests for this study were complementary to and provided supplementary information for the down-selection process during the course of the test program reported in NASA/TP-2015-218207.

Mitchell, M. A.↗