Search NASA⌕ Search

SEARCH · Search NASA

Results for “National Transonic Facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The National Transonic Facility - Status and operational planning

The National Transonic Facility is scheduled to be completed in 1982. Several technical concerns remain, including thermal stress constraints which may limit the rate at which temperatures can be changed, seal performance in the cryogenic environment, and the tunnel process controls which could affect data acquisition rate. The current design affords the capability of dealing with all these concerns if they become problems. The outstanding instrument need is a real-time model surface deformation measurement system. Finally, an examination of the occupancy cost and the cost of liquid nitrogen for high Reynolds number tests indicates that operating costs should not be an inhibiting factor in the use of the facility.

Howell, R. R.↗

The US National Transonic Facility, NTF

The construction of the National Transonic Facility was completed in September 1982 and the start-up and checkout of tunnel systems were performed over the next two years. In August 1984, the Operational Readiness Review (ORR) was conducted and the facility was declared operational for final checkout of cryogenic instrumentation and control systems, and for the aerodynamic calibration and testing to commence. Also, the model access system for the cryogenic mode of operation would be placed into operation along with tunnel testing. Since the ORR, a host of operating problems resulting from the cryogenic environment were identified and solved. These range from making mechanical and electrical systems functional to eliminating temperature induced model vibration to coping with the outgassing of moisture from the thermal insulation. Additionally, a series of aerodynamic tests have demonstrated data quality and provided research data on several configurations. Some of the more significant efforts are reviewed since the ORR and the NTF status concerning hardware, instrumentation and process controls systems, operating constraints imposed by the cryogenic environment, and data quality are summarized.

Bruce, Walter E., Jr.↗

Recent Enhancements to the National Transonic Facility (Mixed Mode Operations)

The U.S. National Transonic Facility continues to make enhancements to provide quality data in a safe, efficient and cost effective method for aerodynamic ground testing. Recent enhancements discussed in this paper include the development of a Mixed-mode of operations that combine Air-mode operations with Nitrogen-mode operations. This implementation and operational results of this new Mixed-mode expands the ambient temperature transonic region of testing beyond the Air-mode limitations at a significantly reduced cost over Nitrogen Mode operation.

Kilgore, W. Allen↗

Force Measurement Improvements to the National Transonic Facility Sidewall Model Support System

The National Transonic Facility is a transonic pressurized cryogenic facility. The development of the high Reynolds number semi-span capability has advanced over the years to include transonic active flow control and powered testing using the sidewall model support system. While this system can be used in total temperatures down to -250Â F for conventional unpowered configurations, it is limited to temperatures above -60Â F when used with powered models that require the use of the high-pressure air delivery system. Thermal instabilities and non-repeatable mechanical arrangements revealed several data quality shortfalls by the force and moment measurement system. Recent modifications to the balance cavity recirculation system have improved the temperature stability of the balance and metric model-to-balance hardware. Changes to the mechanical assembly of the high-pressure air delivery system, particularly hardware that interfaces directly with the model and balance, have improved the repeatability of the force and moment measurement system. Drag comparisons with the high-pressure air system removed will also be presented in this paper.

Goodliff, Scott L.↗

Initial research program for the National Transonic Facility

The construction and checkout of the National Transonic Facility (NTF) have been completed, and detailed calibration is now in progress. The initial NTF research program covers a wide range of study areas falling into three major elements: (1) the assessment of Reynolds number sensitivities for a broad range of configurations and flow phenomena; (2) validation of the ability of NTF to simulate full-scale aerodynamics; and (3) the development of test techniques for improved test simulations in existing wind tunnels. This paper, therefore, is a status report on these various elements of the initial NTF research program.

Gloss, B. B.↗

The US National Transonic Facility, part 1

The construction of the National Transonic Facility was completed in September 1982, and checkout operations started the following month, with the maximum Reynolds number being obtained in May 1983. Following, most of the effort was devoted to installing the model access housings, and adjusting or altering various tunnel hardware systems. In May 1984, preliminary aerodynamic calibration of the tunnel was initiated in parallel with checkout of the tunnel operating systems, and in August 1984, the tunnel was declared operational and turned over to the user organization for a complete aerodynamic calibration and research and development testing. The facility has been operated in both the air and nitrogen modes covering a Mach number range of 0.2 to 1.22 at pressures up to 8.5 atm and at temperatures down to 100K. This paper presents a status of the tunnel operating systems and an overview of the major milestones during checkout.

Bruce, W. E., Jr.↗

The US National Transonic Facility, part 2

The construction of the National Transonic Facility was completed in September 1982, and checkout operations started the following month with the maximum Reynolds number being obtained in May 1983. Afterwards, effort was primarily devoted to installing the model access housings and adjusting or altering various tunnel hardware systems. In May 1984, the aerodynamic calibration started and was performed in parallel with checkout of the tunnel systems. In August 1984, the final operation readiness review was conducted and the facility declared operational for research testing. The facility has been operated in both air and nitrogen modes covering a Mach number range of 0.2 to 1.22 at pressures up to 8.5 atm and at temperatures doen to 100K. A limited amount of tunnel circuit performance information has been obtained and is presented in this paper. An aerodynamic calibration plan has been outlined, and the first part of the steady-state calibration has been completed, of which some results are presented in this paper. The first aerodynamic vehicle, Pathfinder I, was installed in December 1984 for checkout of instrumentation systems, and a status report and some results are presented.

Bruce, W. E., Jr.↗

Description and operational status of the National Transonic Facility computer complex

This paper describes the National Transonic Facility (NTF) computer complex and its support of tunnel operations. The capabilities of the research data acquisition and reduction are discussed along with the types of data that can be acquired and presented. Pretest, test, and posttest capabilities are also outlined along with a discussion of the computer complex to monitor the tunnel control processes and provide the tunnel operators with information needed to control the tunnel. Planned enhancements to the computer complex for support of future testing are presented.

Boyles, G. B., Jr.↗

Cryogenic temperature effects on sting-balance deflections in the National Transonic Facility

An investigation was conducted at the National Transonic Facility (NTF) to document the change in sting-balance deflections from ambient to cryogenic temperatures. Space limitations in some NTF models do not allow the use of on-board angle of attack instrumentation. In order to obtain angle of attack data, pre-determined sting-balance bending data must be combined with arc sector angle measurements. Presently, obtaining pretest sting-balance data requires several cryogenic cycles and cold loadings over a period of several days. A method of reducing the calibration time required is to obtain only ambient temperature sting-balance bending data and correct for changes in material properties at cryogenic temperatures. To validate this method, two typical NTF sting-balance combinations were tested. The test results show excellent agreement with the predicted values and the repeatability of the data was 0.01 degree.

Popernack, Thomas G., Jr.↗

Mach Stability Improvements Using an Existing Second Throat Capability at the National Transonic Facility

Recent data quality improvements at the National Transonic Facility have an intended goal of reducing the Mach number variation in a data point to within plus or minus 0.0005, with the ultimate goal of reducing the data repeatability of the drag coefficient for full-span subsonic transport models at transonic speeds to within half a drag count. This paper will discuss the Mach stability improvements achieved through the use of an existing second throat capability at the NTF to create a minimum area at the end of the test section. These improvements were demonstrated using both the NASA Common Research Model and the NTF Pathfinder-I model in recent experiments. Sonic conditions at the throat were verified using sidewall static pressure data. The Mach variation levels from both experiments in the baseline tunnel configuration and the choked tunnel configuration will be presented and the correlation between Mach number and drag will also be examined. Finally, a brief discussion is given on the consequences of using the second throat in its location at the end of the test section.

Chan, David T.↗

Mach Stability Improvements Using an Existing Second Throat Capability at the National Transonic Facility

Recent data quality improvements at the National Transonic Facility (NTF) have an intended goal of reducing the Mach number variation in a data point to within unit vector A plus or minus 0.0005, with the ultimate goal of reducing the data repeatability of the drag coefficient for full-span subsonic transport models at transonic speeds to within half of a drag count. This paper will discuss the Mach stability improvements achieved through the use of an existing second throat capability at the NTF to create a minimum area at the end of the test section. These improvements were demonstrated using both the NASA Common Research Model and the NTF Pathfinder-I model in recent experiments. Sonic conditions at the throat were verified using sidewall static pressure data. The Mach variation levels from both experiments in the baseline tunnel configuration and the choked tunnel configuration will be presented. Finally, a brief discussion is given on the consequences of using the second throat in its location at the end of the test section.

Chan, David T.↗

The National Transonic Facility - A research perspective

The capabilities of the National Transonic Facility (NTF) at NASA-Langley and its impact on aerodynamics investigations are surveyed. The fan-driven, closed-circuit transonic wind tunnel has an 8.2 sq ft slotted test section. Trials can be run from Mach 0.2-1.2, pressures of 1-8.9 atm, and temperatures of -320 to 150 F using nitrogen as the working gas. Instrumentation has been developed for monitoring force, pressure, attitude, deformation, temperature, skin friction, flow transition, and flow velocity as well as visualizing flows around the models. Pressures of 15-130 psi are available, as are Re up to 120 million at Mach 1. Correlations are being made with flight data from the Shuttle, 767, X-29A, and TACT aircraft for real-world extrapolations. The NTF, when combined with computational fluid dynamics techniques, will permit testing of aerodynamically sophisticated shapes while narrowing the design goals for each model during basic research in fluid mechanics, transport, and aerodynamic phenomena.

Campbell, J. F.↗

Model measurements in the cryogenic National Transonic Facility - An overview

In the operation of the National Transonic Facility (NTF) higher Reynolds numbers are obtained on the basis of a utilization of low operational temperatures and high pressures. Liquid nitrogen is used as cryogenic medium, and temperatures in the range from -320 F to 160 F can be employed. A maximum pressure of 130 psi is specified, while the NTF design parameter for the Reynolds number is 120,000,000. In view of the new requirements regarding the measurement systems, major developments had to be undertaken in virtually all wind tunnel measurement areas and, in addition, some new measurement systems were needed. Attention is given to force measurement, pressure measurement, model attitude, model deformation, and the data system.

Holmes, H. K.↗

The National Transonic Facility: A Research Retrospective

An overview of the National Transonic Facility (NTF) from a research utilization perspective is provided. The facility was born in the 1970s from an internationally recognized need for a high Reynolds number test capability based on previous experiences with preflight predictions of aerodynamic characteristics and an anticipated need in support of research and development for future aerospace vehicle systems. Selection of the cryogenic concept to meet the need, unique capabilities of the facility, and the eventual research utilization of the facility are discussed. The primary purpose of the paper is to expose the range of investigations that have used the NTF since being declared operational in late 1984; limited research results are included, though many more can be found in the references.

Wahls, R. A.↗

Buffet test in the National Transonic Facility

A buffet test of a commercial transport model was accomplished in the National Transonic Facility at the NASA Langley Research Center. This aeroelastic test was unprecedented for this wind tunnel and posed a high risk to the facility. This paper presents the test results from a structural dynamics and aeroelastic response point of view and describes the activities required for the safety analysis and risk assessment. The test was conducted in the same manner as a flutter test and employed onboard dynamic instrumentation, real time dynamic data monitoring, automatic, and manual tunnel interlock systems for protecting the model. The procedures and test techniques employed for this test are expected to serve as the basis for future aeroelastic testing in the National Transonic Facility. This test program was a cooperative effort between the Boeing Commercial Airplane Company and the NASA Langley Research Center.

Young, Clarence P., Jr.↗

National Transonic Facility: A review of the operational plan

The proposed National Transonic Facility (NTF) operational plan is reviewed. The NTF will provide an aerodynamic test capability significantly exceeding that of other transonic regime wind tunnels now available. A limited number of academic research program that might use the NTF are suggested. It is concluded that the NTF operational plan is useful for management, technical, instrumentation, and model building techniques available in the specialized field of aerodynamic analysis and simulation. It is also suggested that NASA hold an annual conference to discuss wind tunnel research results and to report on developments that will further improve the utilization and cost effectiveness of the NTF and other wind tunnels.

Liepmann, H. W.↗

The National Transonic Facility: Review and status report

The status of the National Transonic Facility (NTF) Project and some of the pertinent performance characteristics and features of the new wind tunnel are reviewed. The liquid nitrogen supply, current views of user cost, and the activation schedule are discussed.

Howell, R. R.↗

Status of the National Transonic Facility

Construction status of major tunnel systems/subsystems of the National Transonic Facility, an advanced high Reynolds number capability wind tunnel utilizing cryogenic nitrogen as the fluid medium is presented.

Swain, R. L.↗