Search NASA⌕ Search

SEARCH · Search NASA

Results for “Natural convection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Numerical Simulation of a Natural Convection–Driven Air-Cooled Reactor Cavity Cooling System Experiment

Ensuring the efficient removal of decay heat from the reactor vessel is essential for the safety of advanced reactor technologies. Several Generation-IV concepts incorporate variations in the reactor vessel cooling systems to achieve this objective. High-temperature gas-cooled reactors utilize a reactor cavity cooling system (RCCS), a passive ex-vessel system designed to operate without active components or external power during accident conditions. The RCCS removes decay heat primarily through radiative and convective heat transfer mechanisms. Here, this study presents a comprehensive validation of a computational fluid dynamics Reynolds-averaged Navier-Stokes model for the University of Wisconsin-Madison air-cooled RCCS facility. Validation was conducted for both high- and low-power natural convection cases under a uniform heating profile. Near-wall resolution was found to be critical for accurately modeling natural convection in the RCCS; employing an all-𝑦 + wall treatment resulted in wall temperature discrepancies exceeding 50 °⁢𝐶 compared to a wall-resolved mesh. Thermal-hydraulic behaviors under natural and forced convection conditions were compared within the heated cavity and RCCS. A turbulence model sensitivity analysis indicated that low-Reynolds number k-ɛ, k-ω shear stress transport (SST), and Reynolds stress transport models produce similar wall temperature predictions. A buoyancy modeling sensitivity study revealed that the Boussinesq approximation significantly underpredicted thermal-hydraulic behavior in the RCCS. Based on these findings, modeling recommendations are provided. The validated data set along with identified sensitivities refine the modeling of natural convection in the RCCS. The information produced by this study supports RCCS design, optimization, and safety evaluations, enabling the calibration and verification of reduced-order thermal-hydraulic models.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Heat transfer augmentation of natural convection heat sink through notched fin design

A novel notched fin heat sink with a central opening is proposed in the present study to augment the heat transfer performance of the natural convection heat sink under horizontal configuration. Thermal and airflow behavior in the heat sinks were studied using both experimental and numerical methods. The results showed that the performance of the conventional heat sink can be enhanced by optimizing its fin design. The basic heat sink model provided a 17% reduction in thermal resistance when its fin height and fin spacing were doubled, and it was accompanied by a 21% increase in surface area. The heat sink with a notched fin design with a less surface area offered a 13% lower thermal resistance compared to the basic model by entraining more airflow into the interior fin region. Providing a central opening in the notched fin heat sink can further reduce the thermal resistance by about 13%. Further, this study also analyzed the influence of emissivity of the heat sink on natural convection conditions. The findings demonstrated that the heat sink with an emissivity of 0.9 can reduce the thermal resistance by nearly 23% compared to one with an emissivity of 0.15.

42 ENGINEERING↗

Determination of the natural convection coefficient in low-gravity

Fire safety is an important issue in the current space program; ignition in low-g needs to be studied. The reduction in the gravitational acceleration causes changes in the ignition process. This paper examines the effect of gravity on natural convection, which is one of the important parameters in the ignition process. The NASA-Lewis 2.2 Second Drop Tower provided the low-gravity environment for the experiments. A series of experiments was conducted to measure the temperature of a small copper plate which was heated by a high intensity lamp. These experiments verified that in low-gravity the plate temperature increased faster than in the corresponding 1-g cases, and that the natural convection coefficient rapidly decreased in the low-gravity environment.

Goldmeer, J.↗

Natural convection with combined driving forces

The problem of free and natural convection with combined driving forces is considered in general and all possible configurations are identified. Dimensionless parameters are discussed in order to help categorize the various problems, and existing work is critically evaluated. Four distinct cases are considered for conventional convection and for the situation when the body force and the density gradient are parallel but opposed. Considerable emphasis is given to unstable convection in horizontal layers.

Ostrach, S.↗

Natural convection between concentric spheres

A finite-difference solution for steady natural convective flow in a concentric spherical annulus with isothermal walls has been obtained. The stream function-vorticity formulation of the equations of motion for the unsteady axisymmetric flow is used; interest lying in the final steady solution. Forward differences are used for the time derivatives and second-order central differences for the space derivatives. The alternating direction implicit method is used for solution of the discretization equations. Local one-dimensional grid adaptation is used to resolve the steep gradients in some regions of the flow at large Rayleigh numbers. The break-up into multi-cellular flow is found at high Rayleigh numbers for air and water, and at significantly low Rayleigh numbers for liquid metals. Excellent agreement with previous experimental and numerical data is obtained.

Garg, Vijay K.↗

EVALUATION OF OPERATION TEMPERATURES UNDER NATURAL CONVECTION HELIUM FLOW IN A CONFINED CAVITY

The Spallation Neutron Source (SNS) is a high-power accelerator-based pulsed neutron source led by Oak Ridge National Laboratory (ORNL) to achieve high fluxes of neutrons for scientific experiments. Active and passive cooling of the systems and parts forming the SNS have been considered to warrant the safe operation of the facility. The diverse cooling systems make use of conjugated heat transfer mechanisms to provide a stable operation temperature for all components in the machine. Thermal power deposited into stainless-steel piping lines due to particle radiation may reach values of up to 1.2 W/cc in the regions located closer to the center of the lower IRP. These energy deposition levels, in not actively cooled components, such as the transfer-line-outer-vacuum-layer may increase the temperature of the component beyond design requirement limitations. The evaluation of the operation temperatures for the former components relies in the assumption that a low-pressure helium atmosphere provides enough heat removal capacity based on natural convection phenomena. In this work, the evaluation of steady state temperatures in components such as the CMS transfer lines has been evaluated using computational fluid dynamics (CFD), analytical correlations and experimental measurements. The companion experiments were conducted in a closed helium system at pressures varying from 1.1 to 1.5 bar. A copper rod was affixed horizontally between viewing windows and heated at constant power, and measurements were made of both the rod temperature and ambient temperature via a system fiberoptic distributed temperature sensors and RTDs. It was found that the measured heat transfer coefficients agree well with the predictions of Churchill and Chu correlations across the range of cases considered. Additionally, the ambient helium volume above the rod was imaged via background oriented schlieren (BOS), and these data was used to determine the line-averaged density gradients in this region. These gradients were compared to simulation data to validate the predictions of natural convection simulations.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗

Radial segregation induced by natural convection and melt/solid interface shape in vertical Bridgman growth

The roles of natural convection in the melt and the shape of the melt/solid interface on radial dopant segregation are analyzed for a prototype of vertical Bridgman crystal growth system by finite element methods that solve simultaneously for the velocity field in the melt, the shape of the solidification isotherm, and the temperature distribution in both phases. Results are presented for crystal and melt with thermophysical properties similar to those of gallium-doped germanium in Bridgman configurations with melt below (thermally destabilizing) and above (stabilizing) the crystal. Steady axisymmetric flow are classified according to Rayleigh number as either being nearly the growth velocity, having a weak cellular structure or having large amplitude cellular convention. The flows in the two Bridgman configurations are driven by different temperature gradients and are in opposite directions. Finite element calculations for the transport of a dilute dopant by these flow fields reveal radial segregation levels as large as sixty percent of the mean concentration. Segregation is found most severe at an intermediate value of Rayleigh number above which the dopant distribution along the interface levels as the intensity of the flow increases.

Chang, C. J.↗

Sensitivity Analyses of Natural Convection in the AP1000 Passive Containment Cooling System Following LBLOCA Using CFD

The AP1000 power plant has implemented multiple layers of passive safety systems to enhance reactor safety and ensure system integrity during postulated scenarios, such as loss of coolant accident (LOCA) and main steam line break (MSLB). Among these, the passive containment cooling system (PCCS) is a safety-related system designed to prevent the containment from exceeding the design limits of both pressure and temperature following a postulated design basis accident, by transferring heat from the steel containment vessel to the atmosphere. During LOCA, natural air convection plays a vital role in removing heat from the steel containment vessel to the atmosphere. This is integrated with the condensate film from the Passive Containment Cooling Water Storage Tank (PCCWST). Air natural convection is also the only heat removal mechanism after the dry-out of the PCCWST and during the loss of shutdown decay heat removal (LOSDHR) event. Therefore, it is essential to investigate the thermal hydraulics behavior of the containment under transient conditions to ensure its safety and integrity. This paper presents a simplified CFD/ANSYS FLUENT model developed to analyze the impact of different parameters, such as air relative humidity, air temperature, and steel containment temperature, on the natural convection capability to remove the decay heat following LOCA. The model aims to examine the thermal behavior of the containment and provides a comprehensive understanding of the system's natural convection capability during postulated accidents. The results obtained from the model can be used to improve the safety and integrity of the containment system and provide valuable insights for future research in the field.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Benchmarking a Pronghorn Model of the Natural Convection Shutdown Heat Removal Test Facility Against STAR-CCM+ (Poster)

Summary Verification of Pronghorn’s Net Radiation Transfer via Code-to-Code comparison with STAR-CCM+. Comparison based on Natural Convection Shutdown Heat-Removal Test Facility (NSTF). Near-perfect agreement if conjugate heat transfer inside the riser channels is replaced by fixed temperature. Difference of up to 5K if conjugate heat transfer is modeled (correlation vs. full CFD).

97 MATHEMATICS AND COMPUTING↗

Buoyant and capillary natural convection in infinite horizontal liquid layers heated laterally

Solutions are presented for the equations describing natural convection in a planar, horizontal layer of liquid with a constant, linear temperature gradient along the unbounded top and bottom surfaces. Both buoyancy and capillary forces are considered to drive thermal convection. The results are compared to earlier analyses for bounded liquid layers and then applied to containerless metal melts undergoing solidification in the microgravity environment of near-earth orbit.

Bourgeois, S. V.↗

The Convective Nature of the Tropical Cyclone Lifecycle via GLM and GPM Observations

This study examines the convective nature of the tropical cyclone (TC) lifecycle from tropical storm through extratropical transition. We analyze lightning observations collected from the Geostationary Lightning Mapper (GLM) on the GOES-16 satellite in combination with coincident passive microwave and Ku-band radar observations collected from Global Precipitation Measurement (GPM) mission satellites. A unique aspect of this study, which spans the Atlantic basin hurricane seasons 2018-2020, is that it provides the first known total lightning observations in TCs throughout their extratropical (ET) transition. Analysis of Tropical Storm (TS), Category 1-2 hurricanes (CAT12), Category 3-5 hurricanes (CAT35), and ET time periods, which are grouped by storm-motion and shear-relative characteristics, show that lightning maxima generally occur regimes of down-motion (up-shear), consistent (inconsistent) with previous studies. Further analysis also breaks down time periods by geographic location (e.g., land, coast, ocean) and shear strength; shifting lightning patterns are observed with increasing shear. The lightning maxima are also generally collocated with minima in 37-GHz brightness temperature observations, which is indicative of precipitation-sized ice. DPR Ku-band reflectivity profiles from the GPM Precipitation Feature (PF) database exhibit distinct differences in depth and intensity for electrically active PFs vs those that are not. On average, PFs defined by a rain rate threshold are larger for hurricane strength ITPs (CAT12, CAT35) as compared to either TS or ET ITPs. This indicates that during the hurricane strength ITPs, PFs may be capturing the entire, symmetric rain shield.

hurricane↗

Measurement of the Natural Convection Heat Transfer in a Magnesium Oxide Electrolytic Cell Concept

The rate of heat transfer by natural convection between the wall and electrolyte of an electrolytic cell that produces magnesium (Mg) from magnesium oxide (MgO) at temperatures near 1000 °C in a molten fluoride salt electrolyte is presented. An experimental model of the cell was developed that enabled measurements of the heat transfer in the absence of electrolysis and at temperatures less than 100 °C over ranges of Rayleigh numbers from 1 × 10 -7 to 7 × 10 -8 and Prandtl numbers from 2 to 6200, ranges that include those anticipated in the operation of the MgO electrolytic cell. The model avoids the substantial experimental challenges associated with the high-temperature, corrosive molten salt to enable a conservative estimate of the heat transfer at a lower cost and greater accuracy than would otherwise be possible. The results are correlated by the expression Nu = 0.412Ra 0.23 Pr 0.15 with Nusselt numbers spanning 30–80. The application of the correlation shows that the heat transfer between the cell wall and the molten fluoride electrolyte at ≈1000 °C is characterized by convection coefficients between 100 and 600 W/m 2 -K and is fast enough to enable heat fluxes up to 10 W/cm 2 without compromising the structural integrity of the steel cell wall.

Engineering↗

Numerical analysis of natural convection in two-dimensional square and circular containers in low gravity

A numerical study of natural convection in circular cylinder and square enclosures shows that the analytic low Rayleigh number theory of previous investigators is valid for Rayleigh numbers up to 1000. For a Rayleigh number of 5000, steady state values of maximum fluid velocity differ by 20 percent. This deviation between analytic theory and numerical results increases for higher Rayleigh numbers. In addition, the low Rayleigh number theory is shown to be valid for higher Rayleigh numbers for a portion of the transient phase before significant deviation becomes apparent. It is also shown that square shaped experimental configurations may be analytically approximated with good accuracy by circular cylinders of equal cross sectional area for the prediction of convection velocities and flow patterns at low Rayleigh number.

Robertson, S. J.↗