Search NASASearch

SEARCH · Search NASA

Results for “Network Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Phoenix Dust Storm (PHX-DUST) Scale: A Cooperatively Developed Dust Storm Scale for Phoenix, Arizona

Using extensive localized meteorological and air quality data for central Arizona from 2010 to 2023, we create a postevent dust storm scale for use by the primary stakeholders in central Arizona for the Phoenix metropolitan area called the Phoenix Dust Storm (PHX-DUST) scale. To ensure usability across a wide spectrum of users, a core concept was to “keep it simple.” The PHX-DUST scale is based on (i) maximum dust concentration for particulate matter (PM10) across the network in micrograms per cubic meter which determines category, e.g., “category 5 (the highest observed category)” and category 4; (ii) the number of network monitors achieving dust concentrations above a threshold of 500 μg m−3 (categorized as “widespread” or “isolated,” as measures of spatial extent); (iii) a duration parameter (which determines “long duration” or “short duration”); and (iv) a measure of wind speed over the affected area (maximum wind gust recorded over the network, which may not be the maximum wind of the storm). Using this index for the 189 dust storms impacting the Phoenix metropolitan area for the period 2010–23, the most severe dust storm occurred on 5 July 2011 and is classified as a “Category 5, Widespread, Long-Duration High-Gust” event. This initial attempt at defining the PHX-DUST scale holds valuable applications for research, education, and applied analyses. It demonstrates that a consortium of interested groups can effectively work to create products benefiting the weather community and general public. Here, the PHX-DUST scale can also serve as a foundational framework for application in other regions where dust storms pose a threat to the well-being of populations, infrastructure, and ecosystems.

Atmosphere

Understanding Regional Inertia Dynamics in CAISO from Real Grid Disturbances

The shift from synchronous generators to inverter-based resources has caused power system inertia to be unevenly distributed across power grids. As a result, certain grid regions are more vulnerable to high rate-of-change of frequency (RoCoF) during disturbances. This paper presents a measurement-based framework for estimating grid inertia in CAISO (California Independent System Operator) region using real disturbance-driven frequency data from the Frequency Monitoring Network (FNET/GridEye). By analyzing confirmed disturbances from 2013 to 2024, we identify trends in regional inertia and frequency dynamics, highlighting their relationship with renewable generation and the evolving duck curve. Regional RoCoF values were up to six times higher than interconnection-wide values, coinciding with declining inertia. Recent recovery in inertia is attributed to the increased deployment of battery energy storage systems with synthetic inertia capabilities. These findings underscore the importance of regional inertia monitoring, strategic resource planning, and adaptive operational practices to ensure grid reliability amid growing renewable integration.

Dulal, Saurav [University of Tennessee, Knoxville

Pantex Plant Ogallala Aquifer and Perched Groundwater Contingency Plan

The Pantex Plant Ogallala Aquifer and Perched Groundwater Contingency Plan has been developed in accordance with the requirements identified in the: • Interagency Agreement for the Pantex Superfund Site, Article 8.5 Work to be Performed, • Compliance Plan Provision of Hazardous Waste Permit No. 50284, and • Record of Decision for Groundwater, Soil, and Associated Media, Pantex Plant. A Long‐Term Monitoring System Design has been designed to monitor conditions in the perched groundwater including changes in the perched aquifer as a result of implementing the response actions. Monitoring is required for verifying the effectiveness of perched groundwater response actions (i.e., conditions in the perched aquifer are being affected as intended) and for confirming that the perched aquifer and Ogallala Aquifer characterization as defined in the Resource Conservation and Recovery Act Facility Investigation Report and the Corrective Measure Studies/Feasibility Study remains accurate. If monitoring results obtained through the monitoring network identify an unexpected condition or deviation, contingent actions will be considered and implemented as necessary to ensure continued protection of the Ogallala Aquifer and human health and the environment. Potential deviations to expected technology performance may be encountered for each of the four primary response actions that compose the selected remedy for perched groundwater; Playa 1 Pump and Treat System, Southeast Area Pump and Treat System, Southeast Area In‐Situ Bioremediation System (comprised of the Southeast In‐Situ Bioremediation System Original System, Southeast Area In‐Situ Bioremediation System Extension System, Offsite In‐Situ Bioremediation System, Perchlorate/Chromium ISB, Northeast ISB and County Road 8 ISB), and Zone 11 In‐Situ Bioremediation System. Monitoring will also be conducted to determine if there are deviations to the expected characterization, e.g., contaminants not expected as a result of the RCRA Facility Investigation characterization. Deviations to expected conditions in the Ogallala Aquifer could also be encountered if the response actions in the perched groundwater are not performing as expected, i.e., preventing contaminants from migrating to the Ogallala Aquifer. Currently, Pantex has begun investigation of detections of high explosives above groundwater protection standards in wells on the Texas Tech University property and a plume that is moving to the northeast from that area. Due to those detections, this Plan recognizes the fact that future detections in the Ogallala will be focused on first‐ time detections of analytes. After a remedy is determined, this Plan will require modification to address-deviations and contingent actions. This Plan was developed to identify the contingent actions necessary to mitigate impacts resulting from deviations to site conditions or response action performance. The Plan defines the environmental problem being addressed by the response actions, clarifies the expected conditions and objectives of the response actions, and identifies the potential deviations to the response actions (due to site conditions or technology performance) that could be encountered. The deviations were evaluated to determine the likelihood of occurrence, potential impact, and time to respond to avoid impact. The Plan also identifies the monitoring outlined in the Long‐Term Monitoring System Design Report (Consolidated Nuclear Security, 2024) and Sampling Analysis Plan (PanTeXas Deterrence, 2024) that will be used to detect the deviations. Lastly, the Plan specifies the contingent actions that could be implemented in response to the deviations. Because each response focuses on a discrete portion of the perched aquifer and contaminant plume, each response action has a different set of expected conditions, and therefore differing impacts from deviations to the site and technology expectations. As a result, the contingent actions are identified for each response action and potential deviation including specific constituents, location, and conditions. If deviations are encountered that impact the ability of the response action to meet performance objectives, the contingent actions will be focused on ensuring the response action can meet the performance objective. Contingent actions may be implemented as interim actions (ISMs/removal actions) in accordance with the Record of Decision, Interagency Agreement, and Hazardous Waste Permit‐50284, if warranted by the specific circumstances. For deviations to site characterization expected conditions, the contingent action will focus on determination of the source of the deviation, determination of the appropriate response, and evaluation of additional work to be completed. However, if the deviation to characterization impacts the performance of the response action, the contingent action will again focus on ensuring performance objectives can be met. Early source term removals and cleanup actions have been implemented to protect the Ogallala Aquifer. Because of these actions and based on modeling results, the expected conditions in the Ogallala Aquifer are that constituents of concern will not be detected above the Groundwater Protection Standards (GWPSs) nor will they reach potential points of exposure above the GWPS. The primary deviation of concern for the Ogallala is if constituents are detected in the Ogallala Aquifer near or above GWPSs. If it occurs, this change in expected conditions would require further evaluation of site and contaminant characteristics to determine an appropriate course of action. The evaluation would include additional monitoring, source identification, implementation of interim protective measures (if necessary), and delineation of extent. These evaluations are necessary to determine an appropriate response action for the Ogallala. The primary goal of the Plan is to provide for the continued protection of the Ogallala Aquifer and the health of its consumers. In recognition, this Plan presents a flexible and rational approach for making future decisions associated with confirming the change in perched and Ogallala aquifer conditions and identifying a response (technical activities, changes to response actions, regulatory oversight, and public involvement).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

High-Temperature Aquifer Thermal Energy Storage (HT-ATES) Projects in Germany and the Netherlands—Review and Lessons Learned

Aquifer thermal energy storage (ATES) is a concept that can help to address heating and cooling needs through the use of the subsurface as a seasonal thermal energy storage (STES) system. Over 2800 ATES systems have been deployed with storage temperatures typically below 25 °C and only a few with higher temperatures (>40 °C), which would increase the energy density and utility of the stored thermal fluids. Until now, only a few high-temperature aquifer thermal energy storage (HT-ATES) projects have been initiated and are still in operation. These HT-ATES projects have encountered a range of technical and non-technical challenges. This study reviews ten such projects: four in Germany and six in the Netherlands. The non-technical issues include public acceptance, a lack of regulatory framework for these systems, managing overlapping uses of the subsurface, managing changes with the providers and off-takers of thermal energy, and obtaining financing to implement these projects. Common technical issues include geological factors such as incomplete characterization of the subsurface and reservoir heterogeneity; geochemical issues such as mineral scaling, corrosion, and biofouling; lower than expected thermal recovery; and issues with system design and reliability. This review highlights benefits and challenges faced by HT-ATES projects with the goal to use the lessons learned to improve the siting, design, development, and operation of such systems. Recommendations include improved initial subsurface site characterization, use of coupled process models to optimize system design and predict system performance, cascaded uses of stored thermal energy to better utilize the stored heat, monitoring networks to provide feedback on system performance, and expanded system scale to allow for continued operation even when maintenance of some system components is required. Techno-economic modeling and risk analysis could be used to optimize such HT-ATES project design and identify key factors that will affect sustained economic viability. In addition, design flexibility is important for these systems to allow for changing conditions regarding the supply and demand of thermal energy. Adopting these findings should improve the performance and reduce the risks for future HT-ATES projects worldwide.

15 - GEOTHERMAL ENERGY

Identifying preferential flow from soil moisture time series: Review of methodologies

Abstract Identifying and quantifying preferential flow (PF) through soil—the rapid movement of water through spatially distinct pathways in the subsurface—is vital to understanding how the hydrologic cycle responds to climate, land cover, and anthropogenic changes. In recent decades, methods have been developed that use measured soil moisture time series to identify PF. Because they allow for continuous monitoring and are relatively easy to implement, these methods have become an important tool for recognizing when, where, and under what conditions PF occurs. The methods seek to identify a pattern or quantification that indicates the occurrence of PF. Most commonly, the chosen signature is either (1) a nonsequential response to infiltrated water, in which soil moisture responses do not occur in order of shallowest to deepest, or (2) a velocity criterion, in which newly infiltrated water is detected at depth earlier than is possible by nonpreferential flow processes. Alternative signatures have also been developed that have certain advantages but are less commonly utilized. Choosing among these possible signatures requires attention to their pertinent characteristics, including susceptibility to errors, possible bias toward false negatives or false positives, reliance on subjective judgments, and possible requirements for additional types of data. We review 77 studies that have applied such methods to highlight important information for readers who want to identify PF from soil moisture data and to inform those who aim to develop new methods or improve existing ones. Core Ideas Soil moisture data can be used to identify the occurrence of preferential flow (PF) and its initiating conditions. Various data‐analysis methods to identify PF differ in susceptibility to error, bias, and subjectivity. These methods can utilize vast amounts of data from soil moisture monitoring networks to develop understanding of when, where, and under what conditions PF occurs. Newly developed methods may lead to better accuracy and reliability, and reduce the need for subjective judgments. Plain Language Summary Preferential flow through soil occurs when a large amount of water is suddenly available, as during an intense storm. This type of flow moves rapidly through the soil in distinct narrow pathways rather than moving evenly throughout the body of soil, with major consequences for groundwater resources, ecosystems, spreading of contaminants, and other vital concerns. Methods of detecting preferential flow have been developed that utilize measurements of soil water content made by sensors installed at various depths. This measurement technology has been widely implemented, many locations now having datasets years in length, and various methods have been developed for using these to identify preferential flow. The various methods are based on different features in the soil moisture records and vary in their advantages and shortcomings. In this review, we explain and evaluate these methods, highlighting important information for their implementation to identify preferential flow from soil moisture data and for efforts to develop new methods or improve existing ones.

Nimmo, John R

Evaluation and calibration of MERRA-2 and CAMS reanalysis for PM 2.5 in a semi-urbanized area in the south of the Amazon

Air pollution has significant implications for the climate and poses irreversible risks to human health. The Amazon region of Brazil is severely affected by biomass burning (BB) emissions, yet air quality monitoring remains highly inadequate. Given the scarcity of surface-based observations, reanalysis models have become essential tools for assessing air pollution. Although MERRA-2 and CAMS PM 2.5 products are widely utilized, their validation and comprehensive evaluation for the Amazon Basin remain limited. Here, this study assesses the performance of these products in a semi-urbanized region in the southern Amazon. The calibrated time series was employed to analyze PM 2.5 concentrations from 2003 to 2023. Our results showed satisfactory performance of both products for the 24-h averages of PM 2.5 , with linear correlations above 0.76. However, it was found that both products overestimate surface concentrations. MERRA-2 performed better, with approximately 30% lower bias than CAMS. Time series analysis showed that the study area is strongly impacted by emissions BB in the dry period, mainly in August and September. Furthermore, our findings indicate a positive trend in increasing PM 2.5 concentrations, with a notable rise observed since 2014. The average PM 2.5 levels frequently exceed the daily air quality guidelines established by the WHO in 2021. It has been estimated that the population of this region is exposed to concentrations above 15 μg.m -3 , on average, more than 30 days per year. Our results contribute to the evaluation of MERRA-2 and CAMS products for Amazon and provide a corrected estimate for surface PM 2.5 . Recent concerns about air quality and the implementation of new surface monitoring networks may improve the evaluation of reanalysis products. In the short term, the need for this information makes our assessments indispensable.

54 ENVIRONMENTAL SCIENCES

Evaluation of a catalytically aided thermal regeneration method for quartz filter-based black carbon sensing

Black carbon (BC)–a strong indicator of diesel particulate matter and other sources of incomplete carbonaceous fuel combustion–is an important air pollutant that affects public health, yet low-cost sensors capable of long-term, autonomous BC monitoring remain underdeveloped. We report on the development and evaluation of a novel BC prototype sensor that integrates soot collection on a quartz filter, in-situ optical transmission measurement, and thermal filter regeneration. To enable regeneration at lower temperatures, we evaluated the catalytic effects of various alkali metal salts pre-applied to the filter. Among these, cesium carbonate (Cs 2 CO 3 ) exhibited the strongest catalytic activity, lowering the temperature required for complete BC removal by up to 190 °C and reducing energy consumption by more than 75% compared to that required for untreated filters. The catalytic effect persisted through 10 BC collection–regeneration cycles. These findings demonstrate the potential of catalytically aided thermal regeneration in BC sensors and suggest a pathway toward energy-efficient and reduced maintenance air quality monitoring suitable for distributed BC monitoring networks.

Tang, Xiaochen [Lawrence Berkeley National Laborat

Inertia Estimation and Trend Analysis of the United States Power Grid Interconnections

The transition from conventional to modern power systems is causing an increase in integration of inverter-based resources (IBRs). This generally leads to a decrease in total system inertia, which in-turn increases the system’s rate-of-change-of-frequency (RoCoF) during disturbances. This poses a threat to the frequency stability of the system and may falsely trigger protective devices. To monitor system status and plan for integrating renewable energy sources like photovoltaic, wind, and energy storage systems, a realistic study of inertia estimation and analysis in the United States (US) over the past decade is needed. This paper uses field-measured phasor measurement unit (PMU) data collected throughout the US from 2013 to 2023 via the Frequency Monitoring Network (FNET/GridEye) operated by the University of Tennessee, Knoxville (UTK) and Oak Ridge National Laboratory (ORNL). The collected PMU frequency data is utilized to estimate the system inertia of the three US interconnections: Eastern, Western, and Texas. Various RoCoF time windows are investigated for estimating the inertia of each interconnection by maximizing the correlation coefficient between the measured RoCoF and power mismatch. The resulting inertia trends over the past decade show approximately a 6% decline in inertia in the Eastern interconnection, a 15% decline in inertia in the Western interconnection, and a 16% increase in inertia in Texas. Key insights into how inertia is changing amidst the complex energy landscape are extracted using the fuel mix trend data. This provides valuable information for future energy strategies and planning.

30 DIRECT ENERGY CONVERSION

Comparative Analysis of Inter-Area Oscillations in the US Eastern and Western Interconnections

This paper presents a comparative analysis of interarea oscillations in the US Eastern and Western Interconnections using frequency disturbance data collected from the advanced wide-area Frequency Monitoring Network (FNET/GridEye), enabling us to investigate and compare the oscillation characteristics of both regions. The study analyzes the statistical data from the two interconnections, including total oscillation events, average dominant frequencies, damping ratios, and maximum amplitudes. We also explore the impact of seasonal and daily variations on oscillation occurrences and the influence of different grid topologies and operational practices. The results provide insights into both interconnections' stability and control characteristics, offering valuable information for power system operators to enhance grid stability and oscillation suppression measures.

Fu, Hao [University of Tennessee, Knoxville (UTK)]

Bayesian OED for Seismic Monitoring

SAND2024-13870O The Bayesian OED (Optimal Experiment Design) for Seismic Monitoring code provides the tools to analyze and optimize seismic monitoring networks using Bayesian OED. This method designs a utility function for experiments (network designs) using network analysis and network optimization. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Catanach, Thomas

LANL Meteorological Program: 2023 Data Completeness/Quality Report

Los Alamos National Laboratory (LANL) operates seven mesa-top instrumented meteorology towers: Technical Area (TA) 6, TA-49, TA-53, TA-54, TA-63, TA-54B, and TA-16B. An additional instrumented tower is located in Mortandad Canyon (TA-5 MDCN), and there is a rain gauge at North Community (NCOM), located within the town of Los Alamos. The 10 meter (m) towers at TA-63, TA-54B, and TA-16B have been in testing since they were installed in 2021, and will be included in a future data completeness report. A description of the meteorology monitoring network, prior to the installation of the TA-63, TA-54B, and TA-16B is found in Dewart and Boggs (2014). Four of the mesa-top towers (e.g., TA-6, TA-49, TA-53, and TA-54) are instrumented at the 1.2 m, 11.5 m, 23 m, and 46 m levels. In addition, the TA-6 tower is instrumented at the 92 m level. The TA-5 MDCN tower is 10 m in height and is instrumented at 1.2 m and 10 m. Data are collected and averaged every 15 minutes. Range checking is performed on each measurement every 15 minutes; data that are beyond normal ranges are eliminated from the data set and replaced by a code for missing data. In addition, data are reviewed weekly by qualified meteorologists to identify bad data not identified by the range checking technique. The data steward eliminates these data from the data set and replaces them with a code for missing data. The instrument technicians also review that data and schedule instrument replacement, as required. All instruments are calibrated at a frequency that meets the criteria identified in ANSI/ANS-3.11-2015. Data completeness is determined by the number of total 15-minute records available versus the number of possible measurements for the entire year. As a rule, the meteorologists do not attempt to estimate data that are eliminated as bad data. Original datalogger records, including bad data, can be recalled from program archival storage.

54 ENVIRONMENTAL SCIENCES

Southwest Regional Partnership on Carbon Sequestration: Phase III (Final Scientific/Technical Report)

The Southwest Regional Partnership on Carbon Sequestration (SWP) is one of 7 regional partnerships formed in 2003 under the U.S. Department of Energy’s (DOE) Regional Carbon Sequestration Partnerships (RCSPs) initiative. The overall purpose of the initiative was to help determine and implement the technology, infrastructure, and regulations most appropriate to promote carbon storage in different regions of the country. Covering Arizona, Colorado, New Mexico, Oklahoma, Utah, and parts of Texas, Wyoming, and Kansas, the SWP evaluated regional carbon storage and utilization potential and focused on technologies and sites that could complement the region’s strong position in energy production. The project progressed through three phases: • Phase I (2003–2005): Characterized regional geologic formations and CO 2 sources, assessed sequestration potential, and identified pilot test sites. • Phase II (2005–2013): Conducted small-scale field tests to validate sequestration methods, including geologic and terrestrial projects. • Phase III (2008–2022): Demonstrated large-scale CO 2 injection at a commercial oil field to test monitoring, verification, and long-term storage strategies. This report covers Phase III. The final project site, the Farnsworth Unit (FWU) in Texas, provided real-world testing of reservoir characterization, monitoring, and risk evaluation tools and processes that could be used in any commercial scale carbon capture, utilization, and storage (CCUS) project. Extensive data collection and analysis helped refine best practices for reservoir characterization, injection monitoring, and storage verification. The SWP contributed to national databases, DOE best practice manuals, and regional geological assessments to support future sequestration efforts. Key lessons learned include the importance of robust data management, strategic site selection, regulatory navigation, and effective industry collaboration. The project’s findings will inform ongoing and future carbon storage initiatives. Task 1 (Regional Characterization) • The SWP continued to participate in national outreach efforts and NATCARB. • The SWP evaluated multiple potential sites before selecting the FWU as the primary field test location. Task 2 (Public Outreach and Education) • The SWP contributed to national databases, DOE best practice manuals, and regional geological assessments to support future sequestration efforts. Task 3 (Permitting and Regulatory Compliance) • The SWP ensured compliance with federal and state regulations, including National Environmental Policy Act (NEPA) requirements. • The SWP obtained all necessary permits for drilling, injection, and monitoring activities. Task 4 (Site Characterization and Planning) • The SWP developed work plans for four key activities: characterization, simulation, monitoring and verification, and risk evaluation. • The SWP collected and synthesized legacy data from multiple sources to build initial static geological models and dynamic reservoir models demonstrating project feasibility. • The SWP conducted an initial risk evaluation and developed mitigation plans. Task 5 (Field Operations and Data Collection) • The SWP drilled, logged, and cored three characterization wells to gather critical subsurface data. • The SWP conducted multiple geophysical surveys, including 3D seismic, crosswell seismic, and vertical seismic profiling, to improve reservoir characterization. Task 6 (Monitoring and Verification) • The SWP performed extensive geological characterization using data from characterization wells and seismic surveys. • The SWP established a surface monitoring network to track CO 2 flux in soil gas, groundwater chemistry, and near-surface atmospheric CO 2 levels. • The SWP built and refined reservoir models to study the effects of relative permeability on simulation behavior and improve calibration with experimental data. Task 7 (Risk Assessment and Model Refinement) • The SWP conducted multiple studies to evaluate reservoir integrity, predict CO 2 plume behavior and improve predictive modeling capabilities. • The SWP refined geological models and used them to enhance the accuracy of simulation models. • The SWP continued quantitative risk assessment of top-ranked risks and strengthened the link between qualitative and quantitative risk methodologies.

02 PETROLEUM

Reactor System Facility Modification to Detect Compromised Human Machine Interfaces

This study focuses on a multi-layered Industrial Control System (ICS)/Operational Technology (OT) security architecture to aid in the discovery and mitigation of compromised Human Machine Interface (HMI)/Instrumentation & Control (I&C) based systems for modifying a prototypical reactor condition test facility called the Flowing Autoclave System (FAS) at Idaho National Laboratory (INL). This is achieved through a three-layered combination of network security solutions, hash-based algorithms, and blockchain technologies. Hash algorithms are mathematical functions used to generate a predetermined set of fixed-length values. They are widely used in computer security to verify the integrity of system information and data, both on a local network and the wider internet. Even small amounts of unauthorized system modification will cause the hash algorithm to output a set of characters that deviate significantly from its original value. Assisting secure hash functions, blockchain technology is a secure and distributed technology used to provide an immutable set of records replicated on all devices within a decentralized network. Blockchain offers a cost-effective solution to detect system compromise by providing a traceable breadcrumb trail of all network activity and data modification happening on a system. If both are used in conjunction with network monitoring tools, the integration of this three-pronged approach can become an asset in detecting suspected system compromises before any real damage can occur.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Efficient Signal Processing in BOTDA: Utilizing PCA and PCA-Based Neural Networks for Temperature Monitoring

This work presents a comparative analysis of the various signal processing techniques used in the Brillouin gain spectrum (BGS) peak estimation. Traditional fitting methods such as Lorentzian curve fitting (LCF) are slow and less effective in noisy data. PCA-based methods were tested on the experimental data: A Euclidian distance-based approach, and a probabilistic deep neural network (PDNN) based approach, both using 5 principal components to represent a single BGS. Both methods significantly reduce computational time with respect to LCF, whereas PDNN offers uncertainty insights along with the parameter value. Measuring a range of temperatures, analyzing accuracy, and speed, it can be concluded that PCA trained PDNN outperforms other methods, and appears to be helpful in scenario where large datasets are generated.

Brillouin optical time domain analysis

Brillouin Sensing with PCA, and PCA-Based Neural Networks for Efficient Temperature Monitoring

This work explores peak estimation techniques in Brillouin Optical Time Domain Analysis (BOTDA), emphasizing both accuracy and efficiency. Euclidean distance measurement method is applied to principal components derived from Brillouin Gain Spectrum data. It offers a major speed advantage being 180 170 times faster than traditional curve fitting methods such as Lorentzian curve fitting, while maintaining similar accuracy. Additionally, a PCA- based neural network model shows significant reduction of peak estimation time compared to Lorentzian fitting. Results show Brillouin frequency shift errors lie under 0.75 MHz in both Euclidean distance-based and neural network-based methods, both of which utilize PCA components. For large data sets and long length fibers, PCA- assisted neural network for peak estimation would be an efficient solution.

Distributed optical fiber sensing

Dynamics of argon metastables in Ar–CH 4 radio frequency capacitively-coupled plasma: real-time monitoring with neural network-augmented broadband optical emission spectroscopy

In moderate-pressure radio frequency (RF) capacitively coupled plasmas generated in argon–methane mixtures, the density of argon metastable atoms (Ar 1 s 5 ) exhibits a non-monotonic dependence on methane (CH 4 ) concentration. Laser-induced fluorescence (LIF) was used to measure and compare local Ar 1 s 5 densities in Ar and Ar–CH 4 plasmas at 2.6 Torr and RF powers of 17–117 W. The addition of 1% CH 4 increases the metastable density, and 2% CH 4 triggers a strong depletion by an order of magnitude, compared to 1% CH 4 case. This non-monotonic behavior demonstrates the sensitivity of metastable populations to small gas admixtures, which is critical for processes where metastables drive precursor dissociation. For real-time monitoring of metastable population, broadband optical emission spectroscopy (OES) is augmented with a feedforward neural network (NN) to predict Ar s1 5 densities from spectral features. When trained on LIF data, the NN replicates the absolute densities and the dynamic trends of Ar 1 s 5 density variation. The NN-augmented broadband OES approach can be used as a simple and cost-effective tool for tracking Ar metastables in Ar-rich plasmas, facilitating industrial-scale optimization.

Yatom, Shurik [Princeton Plasma Physics Laboratory

Influence of background sources and topographic resolution in the Weather Research and Forecasting Model on xenon plume characteristics at monitoring stations

For many atmospheric monitoring applications, networks of measurement sites—such as the radionuclide stations of the International Monitoring System—can be sparse. With measurement locations potentially hundreds to thousands of kilometers from a release it is important to quantify the effects of physical processes on transport and dispersion of plumes between source and measurement locations. This study addresses the effects of background sources and topography resolution near the release location of radionuclides. We use the Weather Research and Forecasting (WRF) model with inline chemistry to investigate (1) how an additional, time-varying source of 133 Xe, such as an operational medical isotope production facility, contributes to activity concentration measurements at monitoring sites, and (2) how complex topography influences on atmospheric conditions near emission sources impact plume concentrations at varying distances from the source. Two 133 Xe emission sources, including (1) a high flux rate of short duration representing an explosive event, and (2) a variable and continuous background source, are simulated. The continuous background source contributes significantly to total 133 Xe concentrations at several monitoring stations. Further, a WRF simulation at 9 km horizontal resolution is compared with a nested grid simulation, where the innermost domain has a resolution of 1 km. Increased topographic resolution leads to an improved representation of plume responses to local winds, with topographic influences greatest at locations closest to the sources. Differences between the two domain resolutions decrease at greater distances from the sources, as plumes have time to spread and mix and are influenced by synoptic scale circulation patterns that are represented similarly in both simulations.

54 ENVIRONMENTAL SCIENCES