Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Coincidence Counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Enhanced sensitivity to trace 238 U impurity of sapphire via coincidence neutron activation analysis

Sapphire has mechanical and electrical properties that are advantageous for the construction of internal components of radiation detectors such as time projection chambers and bolometers. However, it has proved difficult to assess its 232 Th and 238 U content down to the picogram per gram level. Here, this work reports an experimental verification of a computational study that demonstrates 𝛾⁢𝛾 coincidence counting, coupled with neutron activation analysis (NAA), can reach ppt sensitivities. Combining results from 𝛾⁢𝛾 coincidence counting with those of earlier single-𝛾 counting based NAA shows that a sample of Saint Gobain sapphire has 232 Th and 238 U concentrations of <0.26 ppt and <2.3 ppt, respectively; the best constraints on the radiopurity of sapphire.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Total Measurement Uncertainty in Neutron Coincidence Multiplicity Analysis

Neutron multiplicity counting is the most commonly used nondestructive assay technique for determining the plutonium mass within containers of scrap PuO 2 or mixed oxide (MOX). In multiplicity analysis, the 240 Pu eff mass, leakage multiplication, and alpha ratio (the ratio of [α, n]-to-spontaneous fission neutron production) are the three primary unknown sample properties. They must be determined simultaneously. To solve for these three unknowns in a multiplicity assay, three measured values are needed: the singles, doubles, and triples neutron count rates. While the analysis is limited to solving for three unknowns, there are many additional factors that impact the observed count rates and contribute to the measurement uncertainty. In this study we investigate the various uncertainty contributors for the multiplicity analysis through a combination of traditional uncertainty propagation techniques supplemented by Monte Carlo simulations to address the dependences not explicitly expressed by the point source model. Uncertainties arising from counting statistics, calibration parameters, calibration method, nuclear data, and various material characteristics (isotopic abundances, chemical form, density, and impurities) are considered. A Total Measurement Uncertainty (TMU) estimate is then developed from these uncertainty contributors. This study is confined to multiplicity analysis of items commonly encountered in international safeguards applications. That is, the study focused on Pu oxides and MOX materials for the masses ranging up to 4000 grams total Pu. Multiplicity measurements were simulated using MCNP V6 based on the Plutonium Scrap Multiplicity Counter (PSMC), Epithermal Multiplicity Counter (ENMC), Pyrochemical Multiplicity Counter, and Large Epithermal Multiplicity Counter (LEMC) for this study; however, this report focuses on the parameterization of the uncertainties for the PSMC. The performance differences between the PSMC and the other multiplicity counting systems are relatively small, primarily manifesting in the impact on measurement precision so that the evaluation developed for the PSMC can be applied to the other multiplicity counting systems. Finally an analysis tool, the Multiplicity TMU Estimator, was developed from this study to serve as an aid for evaluation of the total measurement uncertainty of multiplicity assay results obtained from the commonly used INCC acquisition and analysis software.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

233 U oxide Measurement Campaign Data: Passive and Active Neutron Multiplicity Measurements of Uranium Oxide Samples at Oak Ridge National Laboratory

During FY2023, three measurement campaigns were conducted at Oak Ridge National Laboratory. The goal was to quantify the neutron signatures of samples of uranium oxide containing uranium 233 and uranium-235. This report presents the neutron multiplicity data obtained using the large volume active well coincidence counter (LV-AWCC).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity of the simulation of passive neutron emission from UF 6 cylinders to the uncertainties in both 19 F(α,n) energy spectrum and thick target yield of 234 U in UF 6

Interest in safeguards verification measurements using passive thermal neutron counting to assay 235 U content in large 30B UF 6 canisters has grown in recent years. Here, the prohibitively high cost and impracticality of using reference 30B calibration cylinders extensively will likely make accurate simulations of increasing interest. Accuracy of the simulated response will define the confidence in the predicted response and the extent to which simulations can reasonably be relied upon. With 234 U driven 19 F(α, n) reactions being the main neutron source in low enriched UF 6 the uncertainties of the 19 F(α, n) energy spectrum and the thick target yield of 234 U in UF 6 propagate into the uncertainty in the predicted response and represent a major influence of basic nuclear data. Here sensitivity of the simulated total (Singles) and coincidence (Doubles) count rates are assessed for the Passive Neutron Enrichment Meter using six potential 19 F(α, n) neutron energy spectra over a range of enrichments and material distributions. The results indicate that variations in the Singles and Doubles due to simulated (α, n) neutron spectrum are less than 1.5% for this set of simulated neutron spectra, with dependence varying inversely with enrichment. Singles uncertainty is only slightly less than that of the thick target 19 F(α, n) yield corresponding to the primary neutron source, whereas the 19 F(α, n) yield dependence of the Doubles is reduced by the non-negligible 238 U(SF) coincident neutron emissions. Based on available thick target 19 F(α, n) yield estimates the uncertainty is on the order of 5%, establishing this as the main nuclear data limitation when simulating thermal neutron detectors response for 30B UF 6 storage cylinders. Based on these findings, it appears that the measurement and evaluation of the thick target 19 F(α, n) yield for uranium hexafluoride is due.

19F(α,n) neutron spectrum↗

AWCC Simulations

Neutron well counters provide a means to measure fissile mass by detecting coincident neutrons, which is a unique signature to fission. For coincidence counting, mass is determined using a calibration curve established with items that have the same material characteristics. Multiplicity analysis solves the point model equations for mass using known detector parameters. In both cases, mass measurements may exhibit a bias due to item characteristics and should be corrected for. Experiments can be done to estimate bias and material effects, but they require having both the well counter and the material well defined. In pursuit of estimating measurement bias and uncertainty in a High Efficiency Neutron Counter (HENC), an MCNP simulation was matched to measurements performed with an Active Well Coincidence Counter (AWCC) to de ne a neutron source term. The neutron source term will be used to predict measurement performance of similar material types in a HENC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sensitivity analysis towards trace-uranium detection with γ-γ coincidence NAA

An improved approach for detection of trace amounts of 238 U by means of neutron activation analysis (NAA) is presented. The analysis enhancement is obtained by utilizing γ-γ coincidence counting. An empirical method for evaluating the sensitivity gain in the presence of a large source-related background is presented. A comparison of detection limits is made between two counting schemes; namely, counting single gammas using one HPGe detector versus counting coincident gammas using two HPGe detectors placed face-to-face. Furthermore, a data-validated radiation transport model, created in GEANT4 for a single HPGe detector, is extended to handle the two detector setup. In this counting scheme, a 238 U-detection sensitivity enhancement of about a factor of 8 is predicted for a sample of Saint-Gobain G3 Sapphire when compared to the simpler singles counting approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstrating and Expanding DRiFT’s Helium-3 Detector Response Capabilities [Slides]

Helium-3 tubes are an efficient way to detect neutrons after they have thermalized by polyethylene. They are often arranged in rings to perform coincidence counting. Applications include nuclear safeguards, treaty verification, and emergency response. DRiFT has the ability to simulate pile-up, room return, and end effects. A new feature determines real and accidental correlated counts. The next steps include DRiFT 2.0 released as executable, continued demonstration of gas module capabilities, and semiconductor module under a development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvements to the 115g/115m Cd Nuclear Data

Repeated measurements of the isotope 115m Cd by Los Alamos National Laboratory (LANL), Pacific Northwest National Laboratory (PNNL), and Atomic Weapons Establishment (AWE) have revealed a consistent discrepancy between beta and gamma counting. This suggests that a significant disparity exists between the true value of the isotope’s gamma-ray branching ratios and the values reported by the National Nuclear Data Center (NNDC). Enriched 114 Cd was irradiated using thermal neutrons to produce a high-purity 115m/g Cd source for counting and analysis using traditional singles gamma-ray spectroscopy, liquid scintillation counting, gas-proportional counting, and analysis using the new Gamma-Alpha-Beta-Gamma (GABγ) and Gamma-Alpha-Beta Radio-Isotope EvaLuator (GABRIEL) coincidence detection systems. Using the D-T fusion generated neutrons, reduces the wait time required to let the short-lived 115Cd ground state decay away by leveraging the 1:1 production ratio of the ground and metastable state of 115 Cd from the 115 In (n,p) reaction relative to the 10:1 production ratio of the ground and metastable isotopes of 115 Cd by thermal neutron capture on 114 Cd. However, the much higher flux in from the Washington State University TRIGA reactor is a more rapid method of production of 115m/gCd but requires access to enriched 114 Cd. High purity 115m/g Cd samples were analyzed on regular intervals over a period of 140-days. The activity of 115m Cd measured by beta and gamma show a clear discrepancy using the current best known gamma-ray decay branching ratios. Based on these observations and measurements, a set of new branching ratio recommendations have been produced using conventional counting techniques and the advanced GAB? and GABRIEL instruments.

07 ISOTOPE AND RADIATION SOURCES↗

An Integrated Approach to Precision Neutron Measurements in a Dynamic Environment [Slides]

Any quantity of special nuclear material must be accurately quantified for health, safety, and security concerns. High-Level Neutron Coincidence Counters (HLNCCs) are detectors used for assaying the mass of special nuclear material. HLNCCs record a neutron count rate over some period of time which is compared to a calibration curve to determine the quantity of special nuclear material present within the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Passive Neutron Instrumentation and Applications

This chapter presents a description of most of the instruments that are currently in use for the measurement of plutonium and uranium using passive methods (without an external source). This includes the acquisition electronics as well as Singles counting methods, coincidence counting methods and multiplicity counting methods. The Singles counting applications include the measurement of waste and curium bearing materials. The coincidence counting applications include bulk plutonium, bulk uranium, waste and holdup measurements and fresh fuel assemblies. The multiplicity application description includes advantages and disadvantages and multiplicity detector design. There is also a description of some non-3He systems. The chapter concludes with a description of additional concepts: neutron imagers, list-mode data analysis, distributed source term analysis, unattended monitoring and MCNP modeling for detector design.

Coincidence shift register↗

Rapid neutron and gamma-ray source localization using machine learning

Rapid localization of radiation sources is critical for applications including nuclear emergency response, safeguards, and security. However, conventional imaging systems such as neutron scatter cameras and Compton cameras depend on rare coincidence events, which often result in long acquisition times. In this work, we address the challenge of rapid source localization by developing a machine learning approach to predict the direction of a single radiation source using only count rates from an array of neutron and gamma-ray detectors. The proposed model is a fully connected neural network (FCNN) trained using Monte Carlo simulation data from a 252 Cf source. The model hyperparameters are optimized with a small set of routine 252 Cf measurements. We benchmarked the performance of the trained and optimized machine learning model using additional 252 Cf , 137 Cs , and PuBe measurements under laboratory conditions with varying source-detector configurations. For these measurements, the machine learning model achieved a mean localization error smaller than 30° with 3 x 10 3 system counts, corresponding to 8 s measurement time for the imaging system used in this work. In this low-statistics regime, the method outperformed traditional scatter-based imaging by more than 75% in localization accuracy for the evaluated measurement configurations. These results demonstrate that a machine learning-based approach can significantly reduce the time required for accurate single-source localization, providing a robust and computationally efficient alternative to traditional imaging systems in time-critical nuclear security and emergency response scenarios.

Gamma-ray imaging↗

Associated Particle Imaging of Neutron Inelastic Scatter: 3-D Reconstruction, Capabilities, and Challenges

Associated particle imaging (API) offers unique advantages for 3-D imaging of neutron inelastic scatter, including single-view tomographic imaging and data acquisition when access is limited to only one side of the interrogated object. However, widespread adoption of neutron inelastic scatter imaging has been impeded by several inherent challenges, most prominently spatial resolution, self-attenuation, and statistical noise. Here, in this work, the capabilities and challenges of neutron inelastic scatter imaging are investigated. Instead of focusing on a single imaging application, we identify imaging principles that hold for various neutron inelastic scatter imaging techniques. The primary challenges for 3-D imaging are characterized. The inherent spatial resolution in the time-of-flight (TOF) dimension is derived based on the known system timing resolution and scan geometry. Three reconstruction algorithms are described and demonstrated, including the introduction of modern iterative reconstruction incorporating a physics-based system model. Simulation is leveraged to demonstrate imaging capability with varying coincidence count levels and system timing resolution. An example of measured data with both back-scatter and forward-scatter detector positioning is presented. System design characteristics and their effects on image quality are identified. The imaging framework presented in this article has the potential to facilitate growth of 3-D neutron inelastic scatter API by identifying applications that are a good match for the technique and by targeting system development resources toward the requirements of a specific imaging task.

Associated particle imaging (API)↗

Low spin spectroscopy of neutron-rich Cl 43 , 44 , 45 via β - and β n decay

In this article, β - decay studies of neutron-rich isotopes 43,45 S performed at the National Superconducting Cyclotron Laboratory are reported. β -delayed $\gamma$ transitions were detected by an array of 16 clover detectors surrounding the Beta Counting Station, which consists of a 40×40 double-sided silicon strip detector followed by a single-sided silicon strip detector. β -decay half-lives were extracted for 43,45 S by correlating implants and decays in the pixelated implant detector and by considering further coincidences with $\gamma$ transitions in the daughter nuclei. Further, the level structures of 43,45 Cl are expanded by the addition of 20 and 8 new $\gamma$ transitions in 43 Cl and 45 Cl respectively, and core-excited negative-parity states were observed in both nuclei for the first time. For 45 S, a large fraction of the β -decay strength was observed feeding neutron-unbound states in 45 Cl, which, decaying by delayed neutrons, populated excited states in the β ⁢1⁢ n daughter, 44 Cl. Experimental observations were compared to detailed shell-model calculations using the SDPFSDG-MU interaction to highlight the role of the diminished N = 28 neutron shell gap and the near degeneracy of the proton s 1/2 and d 3/2 orbitals in the structure of the neutron-rich Cl isotopes. The current work also provides further support to a ground-state spin-parity assignment of 3/2 + in 45 Cl.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

127 Xe quantification method development and intercomparison exercise

Monitoring of the atmosphere for fission products ( 131m Xe, 133m Xe, 133 Xe, and 135 Xe) is performed by various laboratories to detect nuclear explosions. Quantification of 127 Xe is not routinely performed by laboratories measuring atmospheric radioxenon because it is not a fission product. 127 Xe was recently detected by a ground-based beta-gamma air monitoring system. When measured using beta-gamma coincidence detector systems, such as those in use on the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT), 127 Xe can interfere with the quantification of fission product radioxenon due to overlap of the 127 Xe beta-gamma coincidence signatures with those of fission product radioxenon. Here, this work demonstrates quantification of 127 Xe at different laboratories with different measurement techniques. Production and purification of 127 Xe was performed by neutron activation of enriched 126 Xe. The purified 127 Xe was then split between laboratories, and detection and quantification methods were developed. At Idaho National Laboratory, a quantification method involving high purity germanium detectors was devised that included self-attenuation correction. At AWE, a beta-gamma coincidence counting method, as used in support of the IMS, was modified to enable the measurement and analysis of the 127 Xe samples. Corrections were made for self-attenuation, which showed a strong xenon volume dependency, for some coincidence signatures. The gas sample activity concentration was used as the comparison metric and it showed excellent agreement between the methods.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Single-Volume Scatter Camera (Final Report)

This document serves as a comprehensive final report for the Single-Volume Scatter Camera (SVSC) project. Most of the work over the course of this project has been documented in journal articles, conference papers, and other reports. We therefore reference those materials for detailed presentation of our technical results. The most recent efforts on the project have not been published and are presented in detail here. We present characterizations of two neutron scatter camera prototypes; one using a monolithic geometry, and one using an optically segmented geometry. Both detectors employ plastic scintillator with SiPM-based readout. For the monolithic prototype, we present calibrations of several detector parameters made using a set of dark counts. In particular, we employ a coincidence analysis to characterize the distribution external optical crosstalk, along with the relative timing of the different SiPMs. For the optically segmented prototype we present the results of calibrations made using a tagged 22 Na source, as well as the results of an imaging measurement made using a tagged AmBe source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distinguishing fissile uranium isotopes using an active well neutron coincidence counter

Proposed thorium-based nuclear fuel cycles are likely to require quantification and verification of 233 U within nuclear material. Because of their similar fission cross sections, active neutron nondestructive assay (NDA) systems may respond similarly to 233 U and 235 U. Traditional safeguards equipment has been optimized for 235 U and 238 U quantification associated with conventional uranium/plutonium fuel cycles and may not be directly applicable to 233 U quantification when mixed with other actinides. This work used models of the large volume active well coincidence counter (LV-AWCC) at Oak Ridge National Laboratory to evaluate the performance of this neutron NDA system to differentiate fissile uranium isotopes. The models were developed to simulate NDA system performance in response to a number of triangular radiation signature training device sources within the central cavity or well. This work predicted that the LV-AWCC can effectively differentiate 233 U from 235 U in certain modes of operation. In active mode, the LV-AWCC with the cadmium liner results in different doubles count rates between the fissile isotopes for a given fissile uranium mass. Without the cadmium liner, the uranium isotopes provide a statistically indistinguishable doubles count rate response for the fissile masses considered in this work (up to approximately 150 g). The cadmium liner serves to harden the neutron interrogation spectrum, which better exploits the notable difference in the 233 U and 235 U fission cross sections at approximately 1 eV. In passive mode, the two fissile isotopes exhibit different doubles and singles count rates regardless of liner presence because the passive source strength of 233 U is approximately 2 orders of magnitude stronger than that of 235 U due to the shorter half-life and correspondingly higher (α, n) yield. We conclude that using neutron interrogation in the LV-AWCC, two measurements are needed to quantify 233 U content in mixed uranium items. The first measurement is used to determine the total fissile uranium mass using a mode that cannot distinguish fissile isotopes (i.e., where a similar response is observed for both fissile uranium isotopes such as active doubles without cadmium or using a thermal neutron interrogation source). In conclusion, the second measurement is used to determine the 233 U content by using a differentiating technique (e.g., passive doubles, passive doubles to singles ratio, active doubles with cadmium).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

252 Cf yield calibration method for nuclear material accountancy and safeguards practitioners

Californium-252 is an isotope commonly encapsulated as a physically small but strong spontaneous fission neutron source for applications in industry, academia, and research. Within the nuclear safeguards community, a well-characterized 252 Cf source is often used as an accessible alternative for plutonium in calibrations measurements, which require the absolute source strength. Current methods of source strength quantification can provide an accurate estimate, approximately 1% uncertainty under optimal conditions, but are typically costly and time consuming. An alternative method was developed to determine 252 Cf source strength using passive neutron correlation counting (PNCC). The PNCC method enables institutions and facilities to perform 252 Cf source calibration measurements in-house using detection systems that are common within the nuclear safeguards community. This novel method was previously successfully demonstrated using neutron multiplicity well counters. However, the previous evaluation utilized detection systems with high neutron detection efficiencies, greater than 60%. The purpose of the current study is to extend the previous evaluation and demonstrate the feasibility of the PNCC 252 Cf calibration method for suite of coincidence counters with lower neutron detection efficiencies, between 15% and 35%, which are more commonly encountered in the field, as well as to provide a step-by-step guide to using the method. The neutron source used in this evaluation was previously certified by the National Institutes of Science and Technology (NIST), which provides a reference for the accuracy of the PNCC method. In conclusion, the present source yield calculations demonstrate excellent agreement with a NIST calibration technique and achieve a standard uncertainty below the target 1%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗