Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Radiation Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Simulation of gallium nitride vertical fin-shaped field effect transistor for use as thermal neutron detector

Through the use of a radiation detection system simulation framework, a gallium nitride vertical fin-shaped field effect transistor (FinFET) was studied for output response when utilized as a thermal neutron detector. The FinFET was assumed to had been backfilled with boron carbide, reactive to thermal neutrons. The GaN FinFET was modeled with radiation transport from MCNP, and the electronic transport from COMSOL Multiphysics. Fabricated FinFET devices (not neutron reactive) were tested to aid in the tuning of the COMSOL FinFET model. Through time-depenent studies, the drain current response pulse to simulated ionization due to single events lead to building of a database of device responses to radiation. By integrating the current pulses over time, the induced charge was calculated. Using the results of the radiation transport PTRAC file in combination with the induced charge database, an integrated charge spectrum was calculated.

Davidson, Bryce L.↗

Precise Measurement of the Neutron Magnetic Form Factor Using Super-BigBite Spectrometer at Jefferson Lab

The GMn experiment (E12-09-019) was conducted at Jefferson Laboratory from late 2021 into early 2022. The goal was to make high-precision measurement of the neutron’s magnetic form factor (GMn) at multiple kinematic points, including Q2 = 3.5, 4.5, 6.5, 8.5, 10, 12, 13.5, 16, and 18 (GeV/c)2. Limited data exist for GMn in the region up to about Q2 = 10 (GeV/c)2, with existing data having large systematic uncertainty. In this experiment, the ratio method was employed to reduce systematic uncertainty by measuring the ratio of neutron and proton yields. The experiment took place at Jefferson Laboratory in Hall A, where the BigBite spectrometer was used to detect the scattered electrons, while the HCal in the SuperBigbite spectrometer was used to detect both neutrons and protons. The protons were deflected slightly upwards with the use of a large-aperture dipole magnet named BigBen, allowing for enhanced particle identification. Extraction of GMn requires taking the ratio of proton and neutron yields. Analysis efforts are still currently underway to refine corrections to the data, including detector efficiencies, radiative corrections, neutron and proton mass identification, and charge exchange.

Lashley-Colthirst, Nathaniel↗

Simulated Performance of the Micro-Pocket Fission Detector in the Advanced Test Reactor Critical Facility

The Micro-Pocket Fission Detector (MPFD) is a small-form–factor real-time fission chamber. MPFD performance has been simulated in the Advanced Test Reactor Critical Facility (ATRC), located at Idaho National Laboratory (INL). Here, the neutron and gamma-ray flux profiles and magnitudes were simulated using Monte Carlo N-Particle (MCNP) in the near-core B-8 irradiation position. These simulations were performed at 69 discrete axial locations inside the B-8 position for three separate orientations of the nearby hafnium outer shim control cylinders and at a power level of 700 Wth. The resulting neutron and gamma-ray flux values were used to determine the MPFD response for various fissile masses and detector gas pressures. The optimal gas-operating pressure was determined to be between 30 and 60 psig. The required fissile-layer mass was determined to be between 1–2 µg of 235 U. Additionally, the gamma-ray to fission-fragment interaction rate was determined to be 4.42 × 10 -3 with average energy deposition for gamma rays and fission fragments in 30 psig argon gas to be 1 keV and 9.5 MeV, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Micro cavity fission chamber radiation detection system

A radiation detector to monitor the neutron flux of a nuclear reactor or other high-radiation environment, that can withstand the high temperatures and radiation fields of such environment, is provided. A small dielectric substrate with a low neutron-activation cross section is provided. The substrate is coated with a neutron conversion material, such as uranium oxide or thorium oxide. One or more substrates form a micro-sized detection cavity that is filled with a detection gas. A voltage is provided across anode and cathode wires in the detection cavity. A neutron absorbed in the conversion material may release reaction products into the gas, causing ionization of the gas which then produces a current or voltage signal. The small detector volume minimizes energy deposition into the detection gas by competing particles such as gamma rays, fast electrons, and beta particles, and therefore minimizes false counts while retaining large signals from neutron interactions.

McGregor, Douglas S.↗

FAST-NEUTRON FLUX IN THE ATMOSPHERE

Neutron flux between one and ten mev from sea level to balloon altitudes, recorded by fast neutron detector insensitive to other radiation

NEUTRON FLUX↗

Scintillation properties of diamond powders and feasibility of using them in thermal neutron detectors

Diamond offers unique properties for radiation detection, including high radiation hardness, very low gamma sensitivity, and fast response. Conventional diamond detectors rely on charge collection, but this approach requires ultra-pure single crystals and suffers from radiation-induced degradation. Here, in this work, we demonstrate an alternative approach using diamonds as scintillators for detection of charged particles and thermal neutrons. Prototypes were fabricated from commercially available diamond powders bonded to glass substrates and coupled with 6 LiF converters and silicon photomultipliers (SiPMs) and conventional PMTs. We characterized their scintillation properties under alpha particle excitation, x-ray photoluminescence, and thermal neutrons. The tryout detectors exhibit strong scintillation light signals, nanosecond-scale response times, and neutron detection efficiencies up to approximately 14 %, evaluated by comparison to conventional 3 He detector with known efficiency. These results demonstrate the feasibility of cost-effective, lightweight and robust diamond scintillation detectors for applications in space and planetary science, nuclear security, safeguards and environmental monitoring requiring efficient, robust, gamma-blind neutron detectors.

47 OTHER INSTRUMENTATION↗

A simulation pipeline for fast neutron imaging and spectroscopy using quantified detector attributes

Radiation imaging capabilities, essential in the nuclear nonproliferation regime, facilitate source localization and, in certain cases, spectroscopy. Scatter-based neutron cameras, which can measure the neutron signatures from special nuclear material, hold particular interest. Systems incorporating organic scintillators can extract neutron energy spectra, potentially distinguishing fission neutron sources from others, such as alpha-neutron sources. The development and testing of a scatter-based neutron imager, however, can be challenging without having an accurate simulation model or first constructing a prototype. This work describes a simulation pipeline that takes output from MCNPX-PoliMi simulations and creates the expected back-projection neutron images and neutron energy spectra. This pipeline was developed to improve the modeling of fast neutron imagers and bridge the current gap in literature, which predominantly focuses on gamma-ray Compton imager models. This work also reports on the significance of various real-world system considerations and their effects on the simulated detector responses. The pipeline was verified and validated with experimental data collected using a 252 Cf spontaneous fission source using a fast neutron scattering imager developed at the University of Michigan.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge carrier motion and effect of fixed oxide charge in a microstructured silicon radiation detector

Signal formation in a microstructured semiconductor neutron detector is more complex than in planar diode geometry. Three-dimensional microstructures are laterally smaller than the ionization cloud length, and the electric fields may be weak enough to exhibit plasma time effects. This work is the first detailed treatment of charge carrier motion in these complex semiconductor devices to replicate the time profile and signal magnitude. Simulations were performed using COMSOL Multiphysics to investigate various parameters that affect the propagation of the charge cloud. It was observed that the size of the simulated three-dimensional structure had an impact on the induced current pulse, indicating the importance of simulation geometry optimization to accurately simulate charge cloud expansion. COMSOL Multiphysics was used to replicate accurate charge creation profiles using energy deposition information imported from radiation transport codes. A detailed simulation methodology is presented to benchmark preamplifier event pulses along with complexities in modeling the charge carrier motion along the etched microstructured trenches with Si–SiO 2 boundary conditions, including fixed oxide charge and interface trapping.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polimaster PM1401K-3 Test Report

Extensive testing, including measurements on large quantities of special nuclear material, were taken to assess the functionality of the Polimaster PM1401K-3 to other detectors used in the field. The Polimaster can detect alpha, beta, gamma, and neutron radiation. However, efficiency and accuracy has been sacrificed to accomplish this. Compared to the IdentiFINDER 2, SRM, and FH-40 alpha probe, the Polimaster underperforms in almost all categories regarding radiation detection. The Helium-3 neutron detector in the Polimaster, due to a larger volume, outperformed the IdentiFINDER 2 for neutron measurements. The alpha search mode showed higher efficiency than the FH-40 alpha probe, but uses a more complicated process. The user interface is relatively easy to navigate, clear, and comparable to other detectors. However, the detector has added complications when trying to detect alpha or beta radiation or save a spectrum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigating Gadolinium-Lined Sodium-Iodide Neutron Detectors for Mobile Applications

For enhancing the effectiveness of nonproliferation efforts in neutron detection, most portable instruments rely on 6 Li scintillators, 10 B-based detectors, or gas-filled 3 He proportional counters. Additionally, gamma-ray detectors based on scintillators and semiconductors are often employed for search applications to find radioactive material in the field. These systems typically include dedicated detectors along with separate high voltage supplies and processing electronics for the gamma-ray and neutron detectors. Ideally, a portable radiation detection system should be lightweight, compact, and cost-effective. In the field, scintillators can serve a dual purpose: (1) detecting gamma-rays and (2) detecting neutrons. Gamma-ray detection with scintillators is based on the interaction of gamma-rays within the scintillating material, whereas neutron detection depends indirectly on neutron capture events. These capture events generate conversion electrons and gamma-rays, which can interact with the scintillator. For enhancing neutron capture, the scintillator can be surrounded by neutron absorber materials with a high neutron cross section. The resulting secondary electrons and gamma-rays from neutron interactions, depending on the absorber material used, can then be analyzed to detect the presence of neutron sources. Similarly, semiconductor-based detectors can be employed along with neutron absorbers as liners for neutron detection. 158 Gd has a significantly larger neutron cross section than 3 He, commonly used in gas-filled proportional counters, as shown in Figure 1. For thermal (0.025 eV) neutrons, the absorption cross section of 158 Gd is 10,000 times greater than that of 3 He (refer to Figure 1). This feature makes naturally occurring gadolinium, which consists of 24.8% 158 Gd, a promising neutron absorber material for use in combination with gamma-ray detectors–yielding a hybrid detector–for neutron detection.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Radiation damage effects by electrons, protons, and neutrons in Si/Li/ detectors.

The degradation in performance of lithium-compensated silicon nuclear particle detectors induced by irradiation at room temperature with 0.6-MeV and 1.5-MeV electrons, 1.9-MeV protons, and fast neutrons from a plutonium-beryllium source has been investigated. With increasing fluence, the irradiations produced an increase of detector leakage current, noise, capacitance, and a degradation in the performance of the detector as a charged-particle energy spectrometer. Following the irradiations, annealing effects were observed when the detectors were reverse-biased at their recommended operating voltages. Upon removal of bias, a continuous degradation of detector performance characteristics occurred. Detectors which had been damaged by electrons and protons exhibited a stabilization in their characteristics within two weeks after irradiation, whereas detectors damaged by neutrons had a continuous degradation of performance over a period of several months.

Liu, Y. M.↗

Simulating gas-filled neutron detector responses with DRiFT

– Gas-filled neutron detectors have numerous applications across the nuclear engineering and nuclear physics fields. The ability to accurately model and simulate these detectors is important for those applications but is currently limited by the lack of readily-useable detector response software. Recently, the capabilities of DRiFT, a Detector Response Function Toolkit, were expanded to model gas-filled, He-3 and BF3, neutron detectors so that, combined with the radiation transport capabilities of the MCNP code, a high-fidelity treatment of gas-filled neutron detectors can be obtained. Further, this model has been validated by an experiment carried out with the Epithermal Neutron Multiplicity Counter and its capabilities have been demonstrated in two additional experiments. This work shows that utilizing DRiFT to post-process MCNP outputs produces more accurate results than using the MCNP code alone, reducing the difference between experimental and simulated results for measurements taken near the end of a He-3 tube, where the MCNP code struggles to model inactive regions of the detector, from a maximum of 35% with the MCNP code alone to 15% with the MCNP code plus DRiFT. DRiFT's diagnostic capabilities are also demonstrated with measurements for scenarios when pulse pileup or room return effects are significant and must be considered. Altogether, these measurements underpin the ability of DRiFT to accurately model and predict the behavior of gas-filled neutron detectors, making it a valuable tool for the design and testing of systems and experiments that utilize these detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Experimental Feasibility Study on Applying Neutron Tomography to Encapsulated Spent Nuclear Fuel - 20050

Visual inspection makes easier to ensure the integrity and safety of spent nuclear fuel (SNF) than any classical techniques. Various classical techniques have been applied but there are no reliable methods to qualitatively and quantitatively verify spent fuel in dry storage. Thus, the present authors have developed the prototype safeguards apparatus for dry storage employing the array of He-4 gas scintillation detectors (S670E, Arktis Radiation Detectors Ltd., Switzerland), newly designed to simultaneously measure thermal and fast neutrons without any moderators. The S670E detector has a cylindrical shape with a diameter of 52 mm and active length of 600 mm (total length: 875 mm). The detector is filled by He-4 gas with an approximate pressure of 180 bar for fast neutron detection, and its inner wall is coated by Li-6 for thermal neutron detection. The scintillation lights generated via Li-6 nuclear reaction and elastic scattering are collected by 24 SiPMs linearly paired at the center of the detector. The detector delivers a TTL (Transistor-Transistor Logic) output for pulse readout and UART (Universal Asynchronous Receiver Transmitter) for device control. In order to assess feasibility of the apparatus, an experimental system has been designed, built, and optimized via computational studies. Cf-252 neutron sources and linearly arrayed detectors, working as a single detector, were occupied for this study due to the difficulties in working with SNF. The laboratory scale cask (diameter: 0.67 m, height: 1.5 m), minimized by a factor of 10 compared to the actual thickness of a commercial TN-32 cask, was also manufactured. The detector array was designed to rotate the lab-scale cask and obtain 36 image profiles at every 10 degrees. All profiles were aligned in single frame image called a sinogram, and the cross-sectional image was then fabricated by the inverse radon transform algorithm. These experiments have been repeated with different configurations and numbers of sources. Some gamma-ray sources were also measured with neutron sources in order to distinguish between neutron and gamma-ray pulses. Basically, a He-4 detector is designed to run on Linux OS so it is difficult to directly apply to Windows-based equipment widely used in S. Korea. Therefore, a new data acquisition board working on Windows OS was designed and built. The board mainly consists of FPGA (Field Programmable Gate Array) and SoC (System on Chip) for TTL pulse readout, sorting measured data, and transferring data to a user interface. In conclusion, the tomographic system at lab-scale has shown considerable potential to detect a partial or gross defect of encapsulated assemblies in dry storage. Next steps of this study will be to 1) repeatedly carry out experiments to demonstrate scientific reliability and validity, and 2) numerically integrate signals with weight factors to enhance the image quality since the suggested system based on passive interrogation method requires longer measurement time. Finally, the system will apply to a commercial dry storage phased out soon in S. Korea. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Identifying neutron sources using recoil and time-of-flight spectroscopy

Identification of neutron sources is central to nuclear physics and its applications, from planetary science to nuclear security, yet direct source discrimination from measured neutron spectra remains fundamentally elusive. Here, we introduce a Bayesian protocol that directly infers source ensembles from measured neutron spectra by combining full-spectrum template matching with probabilistic evidence evaluation. Applying this protocol to recoil and time-of-flight spectroscopy, we recover single- and two-source configurations with strong statistical significance (beyond 4⁢𝜎) at event counts as low as ∼10 3 . These results demonstrate that neutron spectral signatures can be leveraged for robust source identification, opening a new observational window for both fundamental research and operationally driven applications.

neutron physics↗

Investigations of radiation damaged arranged scintillating particle composites

Composites consisting of periodically arranged scintillating particles within an acrylic (poly methyl methacrylate) matrix are excellent templates for the gamma-insensitive detection of fast neutrons. In order to study the impact of radiation damage on acrylic-based scintillating particle composites, we exposed acrylic samples to different doses of fast neutrons up to 119.7 kGy and investigated the change in optical characteristics using optical absorption spectroscopy in the 200–800 nm wavelength range. The experimental results are compared to coupled MCNP6 and optical ray-tracing (FRED) simulations, and qualitative agreement is found. Neutron-induced radiation damage in the acrylic matrix manifests as a red-shift in the ultra-violet absorption edge of the acrylic and a corresponding decrease in the light propagation efficiency, which leads to detector performance degradation. We show for the first time that the effects of radiation damage can be mitigated by the use of wavelength-shifting coatings. We predict that composites with wavelength-shifting coatings can enable neutron detectors with high tolerance against neutron-induced radiation damage, a property that is particularly desired for neutron detection in high radiation environments.

36 MATERIALS SCIENCE↗