Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Spectrometer Monte Carlo”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

27 records · Page 2

Lifetime measurements of excited states in neutron-rich 53 Ti: Benchmarking effective shell-model interactions

Level lifetimes of the yrast (5/2 - ) to 13/2 - states in the neutron-rich nucleus 53 Ti, produced in a multinucleon-transfer reaction, have been measured for the first time. The recoil distance Doppler-shift method was employed and lifetimes of the excited states were extracted by a lineshape analysis aided by GEANT4-based Monte-Carlo simulations. The experiment was performed at the Grand Accelerateur National d'Ions Lourds facility in Caen, France, by using the Advanced Gamma Tracking Array for the gamma-ray detection coupled to the large-acceptance variable mode spectrometer for an event-by-event particle identification and the Cologne plunger for deep-inelastic reactions. Reduced transition probabilities, deduced from the lifetimes, give new information on the nuclear structure of 53 Ti, and are used to benchmark different shell-model calculations using established interactions in the fp shell.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Top-level physics requirements and simulated performance of the MRSt on the National Ignition Facility

The time-resolving Magnetic Recoil Spectrometer (MRSt) for the National Ignition Facility (NIF) has been identified by the US National Diagnostic Working Group as one of the transformational diagnostics that will reshape the way inertial confinement fusion (ICF) implosions are diagnosed. The MRSt will measure the time-resolved neutron spectrum of an implosion, from which the time-resolved ion temperature, areal density, and yield will be inferred. Top-level physics requirements for the MRSt were determined based on simulations of numerous ICF implosions with varying degrees of alpha heating, P2 asymmetry, and mix. Synthetic MRSt data were subsequently generated for different configurations using Monte–Carlo methods to determine its performance in relation to the requirements. The system was found to meet most requirements at current neutron yields at the NIF. This work was supported by the DOE and LLNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Top-level physics requirements and simulated performance of the MRSt on the National Ignition Facility

The time-resolving Magnetic Recoil Spectrometer (MRSt) for the National Ignition Facility (NIF) has been identified by the US National Diagnostic Working Group as one of the transformational diagnostics that will reshape the way inertial confinement fusion (ICF) implosions are diagnosed. The MRSt will measure the time-resolved neutron spectrum of an implosion, from which the time-resolved ion temperature, areal density, and yield will be inferred. Top-level physics requirements for the MRSt were determined based on simulations of numerous ICF implosions with varying degrees of alpha heating, P2 asymmetry, and mix. Synthetic MRSt data were subsequently generated for different configurations using Monte–Carlo methods to determine its performance in relation to the requirements. The system was found to meet most requirements at current neutron yields at the NIF. This work was supported by the DOE and LLNL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact, low-power epithermal neutron counter for lunar water detection

The detection and characterization of lunar water are critical for enabling sustainable human and robotic exploration of the Moon. Orbital neutron spectrometers, such as instruments on Lunar Prospector and the Lunar Reconnaissance Orbiter, have revealed hydrogen-rich regions near the poles but are limited by coarse spatial resolution and low counting efficiency. We present a compact, lightweight, and low-power epithermal neutron detector based on boron-coated silicon imagers, designed to probe subsurface hydrogen at decimeter scales from mobile platforms such as lunar rovers. This instrument leverages the high neutron capture cross-section of 10 B to convert epithermal neutrons into detectable α and 7 Li ions in a fully-depleted silicon imager, providing a unique event topology to identify neutrons while suppressing backgrounds. Monte Carlo simulations demonstrate that a 3 μm boron layer achieves optimal neutron detection efficiency, further enhanced with polyethylene moderation to improve sensitivity to the 0.4 eV–500 keV epithermal energy range. For a 10 cm 2 active area, the detector achieves sensitivity to H 2 O weight fractions as low as 0.01 wt% in a 15 minute measurement. This scalable, portable, low-mass design is well-suited for integration into upcoming Artemis and commercial lunar rovers, providing a transformative capability for in-situ resource prospecting and ground-truth validation of orbital measurements.

Detector modelling and simulations I (interaction ↗

Interpreting scattered neutron spectra on omega cryogenic implosions with measured backgrounds and higher-order scattering

Measurements of the areal density (⁠ρR⁠) of inertially confined implosions are critical to evaluate their performance. On OMEGA, ρR is inferred from measurements of the scattered neutron spectrum via neutron-time-of-flight (nTOF) and magnetic recoil spectrometer detectors. The nTOF measurements, in particular, have the ability to measure a wide range of neutron energies and thus scattering angles, with high precision. However, the neutrons that are backscattered into the detector must transit through the entire dense fuel assembly, and as a result are subject to rescattering effects, which have been heretofore neglected in the interpretation of OMEGA neutron spectra. At the backscatter edge, neglecting rescattering on OMEGA can lead to a ~10 to 20% reduction of the apparent areal density and therefore must be included in the analysis. The low ρR s on OMEGA also mean that backgrounds from non-target physics effects, such as scattering in the target chamber or slow scintillator decays, can significantly alter the measured signal. Here, we discuss how the Monte Carlo neutron spectrum postprocessor IRIS is used to include second-order scattering effects in the interpretation of the scattered neutron spectrum in OMEGA implosion experiments, and how dedicated implosion experiments are used to measure nTOF backgrounds in order to infer backscattered areal densities on OMEGA.

Deuterium↗

Neutron Spectrum and 10B(n,α) Measurements in ZPPR-15

Neutron spectra were measured at the core center with proton recoil spectrometers in ZPPR15A loading 66, ZPPR-15B loading 90 and ZPPR loading 186. In addition, neutron spectra were measured in the SSNA shield configuration in ZPPR-15B loading 121 and in the BCNA shield configuration in ZPPR-15B loading 126. The ZPPR-15 neutron spectrum measurement and data processing techniques were described and analyzed. Total uncertainties were derived for all five spectrum measurements. A back-to-back proportional counter was used to measure the 10 B(n,α) reaction rate at six locations in the simulated shield, radial reflector and outer core in the ZPPR-15B BCNA shield experiment. The measurements were described and analyzed. A total uncertainty was derived for the 10 B(n,α) reaction rate measurements. The ZPPR-15 experimental records were used to develop detailed as-built Monte Carlo models for the five neutron spectrum measurement configurations and for the six 10 B(n,α) measurement configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determining the 9 $\mathrm{Be}$($n, γ$) 10 $\mathrm{Be}$ integral cross section at fission neutron energies

The 9 B neutron capture cross section has significant implications for Be materials in the nuclear industry as well as the α process in stellar nucleosynthesis. While the cross section is well constrained at thermal neutron energies, there is a lack of experimental data at higher neutron energies, and the evaluated nuclear data libraries can differ by up to two orders of magnitude. We calculate the 9 Be(n, γ) 10 Be integral cross section at fission neutron energies in an effort to resolve disagreements amongst the nuclear data libraries. Foil irradiation experiments were performed using the Flattop critical assembly at the National Criticality Experiments Research Center with either the highly enriched U or Pu cores, with target foil stacks placed at multiple locations to exploit different neutron energy profiles. Accelerator mass spectrometry was used to measure the 10 Be/ 9 Be ratio in irradiated Be foils, while all other activation products were quantified through gamma spectrometry. The experiments were simulated using the Monte Carlo N-Particle radiation transport code and combined with experimental results to determine the total neutron fluence, while the staysl-pnnl suite and fispact-ii code were used to validate the model and assess the systematic uncertainty. The new 9 Be(n, γ) 10 Be integral cross sections calculated in this work are 26.5 ± 2.2µb at 0.59 ± 0.07 MeV, 24 ± 3 µb at 0.98 ± 0.14 MeV, 21.7 ± 1.3 µb at 1.26 ± 0.11 MeV, 21.8 ± 1.4 µb at 1.32 ± 0.11 MeV, and 18.6 ± 1.1 µb at 1.46 ± 0.13 MeV. These results do not agree with integral cross sections from any of the nuclear data library evaluations. Discrepancies between the new integral cross sections reported here and the nuclear data libraries suggest a more complex cross-section structure in the MeV range which allows for more resonance contributions, and more work is needed to further constrain the evaluated cross sections.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Phased plan for the implementation of the time-resolving magnetic recoil spectrometer on the National Ignition Facility (NIF)

The time-resolving magnetic recoil spectrometer (MRSt) is a transformative diagnostic that will be used to measure the time-resolved neutron spectrum from an inertial confinement fusion implosion at the National Ignition Facility (NIF). It uses a CD foil on the outside of the hohlraum to convert fusion neutrons to recoil deuterons. An ion-optical system positioned outside the NIF target chamber energy-disperses and focuses forward-scattered deuterons. A pulse-dilation drift tube (PDDT) subsequently dilates, un-skews, and detects the signal. While the foil and ion-optical system have been designed, the PDDT requires more development before it can be implemented. Therefore, a phased plan is presented that first uses the foil and ion-optical systems with detectors that can be implemented immediately—namely CR-39 and hDISC streak cameras. These detectors will allow the MRSt to be commissioned in an intermediate stage and begin collecting data on a reduced timescale, while the PDDT is developed in parallel. A CR-39 detector will be used in phase 1 for the measurement of the time-integrated neutron spectra with excellent energy-resolution, necessary for the energy calibration of the system. Streak cameras will be used in phase 2 for measurement of the time-resolved spectrum with limited spectral coverage, which is sufficient to diagnose the time-resolved ion temperature. Simulations are presented that predict the performance of the streak camera detector, indicating that it will achieve excellent burn history measurements at current yields, and good time-resolved ion-temperature measurements at yields above 3 × 10 17 . The PDDT will be used for optimal efficiency and resolution in phase 3.

47 OTHER INSTRUMENTATION↗

Neutral Pion Electroproduction and development of a Neutral Particle Spectrometer

Protons and neutrons, i.e. nucleons, are the basic building blocks of the matter in the visible universe. The strong force binds the nucleons to form nuclei. The electromagnetic force forms the atoms by binding the electrons with the nuclei. The electromagnetic interaction is well understood by Quantum Electrodynamics (QED), which shows the most precise predictability amongst all the theories in physics. In QED, charges interact with each other by exchanging photons. The Quantum Chromodynamics (QCD) describes the strong interaction. Its degrees of freedom are quarks and gluons, the fundamental constituents of the nucleons. The quarks interact with each other by exchanging gluons. However, unlike QED, the gluons interact amongst themselves. This feature of self bindings of the gluons confines the quarks and gluons in the nucleons/hadrons, never to be seen as free. In order to study some of the features of QCD, such as confinement or the structure of the nucleon, one usually needs to rely on experiments. Electromagnetic probes, governed by the well-understood QED, are excellent tools to probe the nucleon. In general, different scales, e.g. electron beam energies, probe different regions of the nucleon. At low energy, of the order of a few GeV, the electron probes the nucleon in the valence quark region. As its energy increases, the electron probes the sea quark and gluon regions. The study of the nucleon structure in all these regions is needed to fully understand QCD. Form factors and parton distribution functions measured from elastic scattering and deep inelastic scattering of leptons off nucleons have provided a partial view of the internal structure of the nucleon. In the mid-1990s, Generalized Parton Distributions (GPDs) were developed. These new objects are a generalization of the form factors and parton distribution functions, but contain richer information on the nucleon internal structure. GPDs are accessible experimentally by deep exclusive reactions. Deeply virtual Compton scattering (DVCS) and deeply virtual meson production (DVMP) are some examples. The first dedicated DVCS/DVMP experiment took place in 2004 in Hall A at The Thomas Jefferson National Accelerator Facility, i.e. Jefferson Lab, in Virginia, U.S.A. A new DVCS/DVMP experiment, after the beam energy upgrade of Jefferson Lab, was carried out in Hall A in a wider kinematic range. Its data were taken from 2014 to 2016. In Hall C at Jefferson Lab, the next DVCS/DVMP experiment will take place. The Hall C experiment will further exploit the kinematic range with higher precision. A Neutral Particle Spectrometer (NPS) is in development to measure DVCS/DVMP events under high background conditions. Jefferson Lab will provide the highest precision data in the valence quark region for various exclusive reactions. The Electron-Ion Collider (EIC) is a future experimental facility currently planned to start operations around 2030 in the U.S.A. Its high energy and high luminosity will probe the sea quark and gluon regions providing answers to the outstanding questions of QCD, in particular in the region where matter is dominated by gluons. First of all, this document describes the data analysis and results of the Hall A neutral pion electroproduction off the proton, from the data taken in 2014-2016. Later, some of the developments towards the construction of the electromagnetic calorimeter of the NPS for the upcoming DVCS/DVMP experiment in Hall C are presented. Finally, one of the candidate materials for the EIC calorimeter, a glass scintillator, will be briefly introduced. I have participated to all these projects, in collaboration with many colleagues. I present in this thesis my contributions to each of these projects. My contributions to the neutral pion data analysis were focused on background subtractions on the calorimeter, acceptance calculations, and the estimation of the systematic uncertainty associated to the event selection cuts. Some necessary information on calibrations of the detectors and data analysis methods are also described. In the NPS project, I performed background dose calculations and energy and position resolution studies of the calorimeter, all using Monte Carlo simulations, with realistic geometries of the experimental apparatus. Characterization of the crystals of the calorimeter was also done. Additionally, I measured the radiation hardness of some glass scintillator in its early stage of development. In order to have a future reference when the glass calorimeter prototype will be tested, I simulated the energy resolution of the prototype.

Ko, Ho-San↗