Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron activation system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Absolute Neutron Emission Measurement in Burning Plasma Experiments

The absolute measurement of neutron emission rate from the whole plasma is a very important diagnostics as a fusion power monitor in fusion experimental devices with D-T or D-T operations. Here measurement techniques of time-resolved and time-integrated absolute neutron emission on the present tokamaks and ITER are reviewed. In the present tokamaks, fission chamber installed outside the vacuum vessel are very popular in the absolute neutron emission rate measurement. As well as conventional neutron monitors installed outside the vacuum vessel, in-vessel neutron monitors using micro fission chamber are proposed for the absolute neutron emission rate measurement in ITER. The neutron activation system provides time-integrated measurements of the total neutron yield with high accuracy by using well known neutron reaction cross sections, which is useful to maintain a robust measure of fusion energy production with stability and wide dynamic range. The calibration of the relation between the neutron emission rate in the whole plasma and the output of neutron monitor is the most important issue in the absolute neutron emission rate measurements. The calibration of the neutron detectors has been performed by moving a neutron source such as a {sup 252}Cf neutron or a small accelerator-based neutron generator. For the calibration in ITER, the neutron generator with neutron emission rate of 10{sup 11} s{sup -1} or stronger is required to obtain high accuracy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of HPGe gamma spectrometric detectors systems for Instrumental Neutron Activation Analysis (INAA) at the Colombian Geological Survey

This paper presents the progress made by the Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey (SGC in its Spanish acronym), towards the characterization of its gamma spectrometric systems for Instrumental Neutron Activation Analysis (INAA), with the aim of introducing corrections to the measurements by variations in sample geometry. Characterization includes the empirical determination of the interaction point of gamma radiation inside the Germanium crystal, through the application of a linear model and the use of a fast Monte Carlo N-Particle (MCNP) software to estimate correction factors for differences in counting efficiency that arise from variations in sample density between samples and standards.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermodynamic parameters for the complexation of Tc(IV) with bromide under aqueous conditions

Technetium-99 is a long-lived fission product present in nuclear wastes, found mainly as Tc(VII) and Tc(IV) in the environment. The quantification of the equilibrium constants for the formation of Tc(IV) aqueous complexes has been limited to carboxylate ligands and interactions with the halides is mostly unknown. This work reports equilibrium constants of the formation of the TcO(OH) + complexes with Br - , in a 3 M NaClO 4 solution of pcH 2 and varied temperature, using a liquid-liquid extraction system. Neutron activation confirmed the suitability of the extraction technique for this work. Under the working conditions, Br - forms a weak exothermic TcO(OH)Br complex, with a Gibbs free energy (ΔG r ) of 3 ± 3 kJ · mol -1 at a temperature of 273.15 K. The values for ΔH r (-32 ± 3 kJ · mol -1 ) and ΔS r (106 ± 9 J · mol -1 · K -1 ) of the complexation reaction were quantified using a van’t Hoff analysis. This work also showed that bromide addition does not displace the hydroxide from TcO(OH) + , as the equilibrium constant of bromide addition is much weaker than the first hydrolysis constant of the metal.

Chemistry↗

Optimization Simulations for a Gamma-Ray Calibration Standard for a Cyclic Neutron Activation Analysis Pneumatic System at the Penn State Breazeale Reactor

For new experimental setups, the initial testing and calibrations can be expensive and time consuming without prior optimization. However, these issues can be mitigated using realistic modeling and simulation studies of the proposed system a priori. Specifically, an experiment can be performed virtually using realistic simulations and the expected results evaluated to inform adjustments of the experimental setup to achieve optimum results. At the Penn State Breazeale Reactor, a new pneumatic transfer system has been developed for the detection and characterization of short-lived fission fragments to enhance and complement existing nuclear data. The system accomplishes this task by transporting samples cyclically between an assortment of gamma-ray/neutron detectors and the reactor-core vicinity with sub-second transit times. The measured neutron flux paired with simulations of detector response using Geant4 and a custom module for estimating cascade summing effects and corrections were used to select sample-material masses for system characterization. With the optimized sample masses, an experimental counting plan for characterizing the repeatability of the newly developed pneumatic system was developed. Finally, the predictions made with these simulations allowed for optimization of the irradiation sample characteristics and gamma-ray detection system.

cyclic neutron activation, gamma-ray spectroscopy↗

Designing ARIES-CS compact radial build and nuclear system: Neutronics, shielding, and activation

Within the ARIES-CS project, design activities have focused on developing the first compact device that enhances the attractiveness of the stellarator as a power plant. The objectives of this paper are to review the nuclear elements that received considerable attention during the design process and provide a perspective on their successful integration into the final design. Among these elements are the radial build definition, the well-optimized in-vessel components that satisfy the ARIES top-level requirements, the carefully selected nuclear and engineering parameters to produce an economic optimum, the modeling for the first time ever-of the highly complex stellarator geometry for the three-dimensional nuclear assessment, and the overarching safety and environmental constraints to deliver an attractive, reliable, and truly compact stellarator power plant.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MCNP Simulation of Discrete Gamma-ray Spectra for PGNAA Applications

Prompt Gamma Neutron Activation (PGNAA) systems use the neutron-induced gamma-ray spectra from test objects in order to identify their compositions. The U.S. Army in particular uses these systems to identify the contents of field-recovered munitions in order to determine the presence of chemical warfare materiel (CWM) or explosives. These field-recovered munitions can have a variety of different fills, including experimental fills, have a large range of sizes, and be assessed in different field conditions. All these variations can have a significant effect on the neutron-induced gamma-ray spectrum and therefore a large impact on automatic fill identification algorithms. In order to develop robust identification algorithms, parametric studies of the effects of munition size, fill composition, and assessment conditions are very useful but time-consuming and expensive in the laboratory. Monte Carlo modeling of the system response to these variations is a very attractive alternative, provided the modeling accurately reflects real gamma spectra and can be performed quickly and inexpensively when compared to experiment. At Idaho National Laboratory we have used the Monte Carlo N-Particle (MCNP6) code [2] to calculate the response of the Portable Isotopic Neutron Spectroscopy (PINS) system to a number of simulated chemical warfare munitions as well as performed laboratory measurements with the system. Two versions of PINS system were used; one excited the test object with neutrons from a 252C f source and one with neutrons from a portable deuterium-deuterium (DD) neutron generator. The sets of measurements and simulations with the two different neutron sources provided experimental data for development of automatic fill identification algorithms as well as providing a good test of the agreement between the MCNP calculations and experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Multi-Energy Approach for Neutron Interrogation of Uranium Items

Bulk uranium items are often measured using active neutron interrogation systems to take advantage of the high penetrability of neutrons, providing the ability to quickly and accurately measure effective uranium masses in large, dense configurations. These active techniques employ an external neutron source to induce fission in the uranium and subsequently measure emitted prompt fission or delayed neutrons. Unfortunately, the emitted neutrons from 235U and 238U are, for all practical purposes, indistinguishable; therefore, common systems such as the Active Well Coincidence Counter and other systems based on measurement of prompt or delayed fission neutrons require many representative calibration standards or known isotopic information to interpret the results, thus limiting the application of these techniques for safeguards purposes. This paper presents the motivation for a multi-energy neutron interrogation technique which aims to improve the accuracy of these NDA techniques through the use of multiple neutron interrogation sources. Potentially, the dual measurement approach will allow the mass values of the isotopes in the item to be independently determined while minimizing the number of representative standards needed and/or eliminating the need for prior knowledge of the isotopic information. This work examines the change in fission rates with differing interrogating neutron energy and, therefore, the potential of this new technique to independently measure the masses of 235U and 238U in the measurement item. Initial simulation and measurement results will be presented.

Hayward, Jason P.↗

Study of Neutron Induced Activity in Low-Background Gamma Spectroscopy Systems

Cosmic-rays induced neutrons can produce measurable activity in carefully selected materials used for construction of low-background gamma spectroscopy systems. In order to improve shielding of low-background systems, flux of neutrons inside the shield and level of induced activity should be measured.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Identification of Leakage Spectra from Neutron Activation in Glass/Cherenkov Detectors - Paper 96

Oak Ridge National Laboratory has developed a new detector system concept that can be deployed in major US cities to identify the leakage spectrum of a nuclear weapon detonation. The detector is based on a small piece of glass that has been doped with an element that has a high activation cross section and creates a radioactive activation product with a reasonable length half-life. The decay of the activation product(s) after exposure creates Cherenkov light which can propagate to a photomultiplier and can be turned into a count-rate signal. The signal from each glass in each detector in a city can be individually analyzed to determine the amount of activation products produced in the initial exposure. Several activation products can be determined in a single glass if the half-lives are not the same. With a known source location and a detailed 3D model of a city, neutron transport simulations can be made by using a library of known sources to predict the activation amounts each source would have made in the glass detectors. A simple comparison of the measured activation amounts and the predicted activation amounts can identify the source spectrum contained in the library that is the best match. Choosing dopants with a large range in the threshold energy for the activation reactions can help to differentiate the spectra in the library. The method of matching the measured activation amounts to the predicted activation amounts to identify the source spectrum is similar to the analysis used for the passive Activation Foil Integrated Detector System (AFIDS), also developed at Oak Ridge National Laboratory. In AFIDS, wires or foils of known mass and isotopic composition are deployed before and then collected after exposure. Counting gammas in a nearby laboratory determines the activation amounts. The glass/Cherenkov system is active - it uses a battery-powered detector to count flashes of Cherenkov light and to communicate its count rates to a remote location for further analysis. Work has been performed in several areas, including glass making, automated detection and communication systems and software tools for analysis of the signal and source spectrum identification. Bell and Boatner have developed phosphate glasses that incorporate elements with high capture cross sections, and Hayward has simulated the response with Geant4 and measured the response with isotopic gamma sources. This paper will focus on the software tools for determining the activation amounts from the Cherenkov count-rate signal and finding the best matching source spectrum. A test problem in an urban environment is used to demonstrate the potential of a spectrum identification system using neutron activation. The analysis methods developed to identify the neutron leakage spectra from Cherenkov light given off by neutron activation in doped glasses work well. The calculation used to unfold the count-rate information into the number of actual activation products uses robust algorithms that can also compute associated uncertainties. These uncertainties and the known uncertainties of the glass tube material compositions are incorporated into the matching analysis to determine which of the source spectra in the library best matches the measured activation data. Any measurement method used to identify a neutron source spectrum relies at some point on a comparison against known sources; no identification method is definitive. Detection systems measure some physical aspect of the source, not its serial number. Many systems measure the physical aspect to determine that the source has some property, and then leave it to experts to determine which potential sources share that property. The analysis system presented here incorporates the comparison into the analysis itself. The statistical tests show which of the known library sources match the measured data the best and whether that match is a good match. If the best match still does not fit the measured data well (a very high χ{sup 2} value), that indicates the true source is not one of the sources in the library. This is still valuable information for decision makers. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Afterglows from Binary Neutron Star Postmerger Systems Embedded in Active Galactic Nuclei Disks

Abstract The observability of afterglows from binary neutron star mergers occurring within active galactic nuclei (AGN) disks is investigated. We perform 3D GRMHD simulations of a postmerger system and follow the jet launched from the compact object. We use semianalytic techniques to study the propagation of the blast wave powered by the jet through an AGN disk-like external environment, extending to distances beyond the disk scale height. The synchrotron emission produced by the jet-driven forward shock is calculated to obtain the afterglow emission. The observability of this emission at different frequencies is assessed by comparing it to the quiescent AGN emission. In the scenarios where the afterglow could temporarily outshine the AGN, we find that detection will be more feasible at higher frequencies (≳10 14 Hz) and the electromagnetic counterpart could manifest as a fast variability in the AGN emission, on timescales less than a day.

79 ASTRONOMY AND ASTROPHYSICS↗

Improved mesh based photon sampling techniques for neutron activation analysis

The design of fusion power systems requires analysis of neutron activation of large, complex volumes, and the resulting particles emitted from these volumes. Structured mesh-based discretization of these problems allows for improved modeling in these activation analysis problems. Finer discretization of these problems results in large computational costs, which drives the investigation of more efficient methods. Within an ad hoc subroutine of the Monte Carlo transport code MCNP, we implement sampling of voxels and photon energies for volumetric sources using the alias method. The alias method enables efficient sampling of a discrete probability distribution, and operates in 0(1) time, whereas the simpler direct discrete method requires 0(log(n)) time. By using the alias method, voxel sampling becomes a viable alternative to sampling space with the 0(1) approach of uniformly sampling the problem volume. Additionally, with voxel sampling it is straightforward to introduce biasing of volumetric sources, and we implement this biasing of voxels as an additional variance reduction technique that can be applied. We verify our implementation and compare the alias method, with and without biasing, to direct discrete sampling of voxels, and to uniform sampling. We study the behavior of source biasing in a second set of tests and find trends between improvements and source shape, material, and material density. Overall, however, the magnitude of improvements from source biasing appears to be limited. Future work will benefit from the implementation of efficient voxel sampling - particularly with conformal unstructured meshes where the uniform sampling approach cannot be applied. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Feasibility of an Active Interrogation System to Classify Waste with He-4 Neutron Spectroscopy

This work investigates a 4 He-detector active interrogation system that leverages neutron spectroscopy to classify nuclear waste streams. MCNP models tested the concept through the simulation of a D-D neutron generator, an array of 4 He detectors, and various waste compositions. The fast-neutron Differential Die-Away signature was augmented with a neutron-energy discrimination signature. This signature isolates induced fission neutrons, the energy of which is greater than that of the D-D monoenergetic spectrum. With the incorporation of this spectroscopic technique, the measurement time decreased by 3–9% (depending on the degree of neutron moderation and absorption presented by the sample), demonstrating how neutron spectroscopy can enhance active interrogation methods. The reduced measurement times would have significant financial and logistical benefits for facilities with large footprints of low-level waste production.

4He detectors↗

A Comparison of Neutron-Based Non-Destructive Assessment Methods for Chemical Warfare Materiel and High Explosives

Prompt Gamma Neutron Activation Analysis (PGNAA) systems employ neutrons as a probe to interrogate items, e.g. chemical warfare materiel-filled munitions. The choice of a neutron source in field-portable systems is determined by its ability to excite nuclei of interest, operational concerns such as radiological safety and ease-of-use, and cost. Idaho National Laboratory’s PINS Chemical Assay System has traditionally used a Cf-252 isotopic neutron source, but recently a Deuterium-Tritium (DT) Electronic Neutron Generator (ENG) has been tested as an alternate neutron source. This paper presents the results of using both of these neutron sources to interrogate chemical warfare materiel (CWM) and high explosive (HE) filled munitions.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A Comparison of Neutron-Based Non-Destructive Assessment Methods for Chemical Warfare Material and High Explosives

Prompt Gamma Neutron Activation Analysis (PGNAA) systems employ neutrons as a probe to interrogate items, e.g. chemical warfare materiel-filled munitions. The choice of a neutron source in field-portable systems is determined by its ability to excite nuclei of interest, operational concerns such as radiological safety and ease-of-use, and cost. Idaho National Laboratory's PINS Chemical Assay System has traditionally used a {sup 252}Cf isotopic neutron source, but recently a deuterium-tritium (DT) electronic neutron generator (ENG) has been tested as an alternate neutron source. This paper presents the results of using both of these neutron sources to interrogate chemical warfare materiel (CWM) and high explosive (HE) filled munitions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploring Gamma-Ray and Neutron Spectroscopy Missions to Mars Caves [Slides]

In this work, we investigate the sensitivity of active neutron detector systems in Mars caves using MCNP6 to model neutron transport in different cave geometries, compositions, and detectors to determine if active neutron measurements can be used to identify the hydration of cave walls vs floor vs ceilings, and to perform a concept study for potential future Mars cave missions in search of hydration and habitable regions.

79 ASTRONOMY AND ASTROPHYSICS↗

Integrated Nondestructive Assay Systems to Estimate Plutonium in Spent Fuel Assemblies

An integrated nondestructive assay (NDA) system combining active (neutron generator) and passive neutron detection and passive gamma (PG) detection is being analyzed in order to estimate the amount of plutonium, verify initial enrichment, burnup, and cooling time, and detect partial defects in a spent fuel assembly (SFA). Active signals are measured using the differential die-away (DDA), delayed neutron (DN), and delayed gamma (DG) techniques. Passive signals are measured using total neutron (TN) counts and both gross and spectral resolved gamma counts. To quantify how a system of several NDA techniques is expected to perform, all of the relevant NDA techniques listed above were simulated as a function of various reactor conditions such as initial enrichment, burnup, cooling time, assembly shuffling pattern, reactor operating conditions (including temperature, pressure, and the presence of burnable poisons) by simulating the NDA response for five sets of light water reactor assemblies. In this study, we compare the performance of several exploratory model-fitting options (including neural networks, adaptive regression with splines, iterative bias reduction smoothing, projection pursuit regression, and regression with quadratic terms and interaction terms) to relate data simulated with measurement and model error effects from various subsets of the NDA techniques to the total Pu mass. Isotope masses for SFAs and expected detector responses (DRs) for several NDA techniques are simulated using MCNP, and the DRs become inputs to the fitting process. Such responses include eight signals from DDA, one from DN, one from TN, and up to seven from PG; the DG signal will be examined separately. Results are summarized using the root-mean-squared estimation error for plutonium mass in held-out subsets of the data for a range of model and measurement error variances. Different simulation assumptions lead to different spent fuel libraries relating DRs to Pu mass. Some results for training with one library and testing with another library are also given.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Determining 235 U enrichment in bulk uranium items using dual-energy interrogation with delayed neutron measurement

Bulk uranium items are often measured using active neutron interrogation systems to take advantage of the relatively high penetrability of neutrons, providing the ability to measure uranium mass in large, dense configurations. Because the emitted neutrons from 235 U and 238 U in such configurations are, for all practical purposes, indistinguishable, established active measurement techniques require many representative calibration standards and/or well-known isotopic information to interpret the assay results (i.e., extract an isotopic mass from the effective mass). Here, the primary objective of this work is to investigate the ability of a dual-energy neutron interrogation technique to estimate uranium enrichment for bulk materials, which has the potential to eliminate the need for a (traditionally separate) gamma isotopic measurement. Dual neutron interrogation energies were achieved by adding a deuterium–tritium (D–T) neutron generator into the measurement chamber of the Oak Ridge National Laboratory 252 Cf Shuffler. This new technique exploits the change in fission rates as a function of interrogating neutron energy to independently determine the 235 U and 238 U content in the measurement item. Results from traditional 252 Cf measurements and the new D–T measurements were then used to develop a relationship between uranium enrichment and the ratio of the two delayed neutron count rates. Lastly, technical feasibility is successfully demonstrated using the modified 252 Cf Shuffler as a test bed, although several areas where refinements are both possible and needed before DEANI can be deployed as an analytical tool to meet specific measurement goals are identified.

252cf shuffler↗