Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron coincidence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The Impact of Increased Requirements for Verification Measurements of Category III and IV Receipts

As part of the regular nuclear material accounting and control process, sites that have accountable nuclear material regularly perform measurements of the material in their possession. The expectation for the type of measurements and their frequency is set out in Department of Energy (DOE) Order 474.2, and further detailed in each site’s respective material control and accountability (MC&A) plan and associated controlling documents. The measurements of interest in this report are those performed on external (between DOE sites) transfer receipts of Category III or IV accountable materials. In 2020, a revision of DOE Order 474.2 was proposed that would significantly increase the requirement that measurements be performed upon receipt of material, and further, that those measurements be quantitative verification (rather than qualitative confirmatory) measurements. A survey was performed of DOE sites to discuss the impact on their MC&A measurements program if more rigorous verification measurements requirements for Category III and IV receipts were implemented. An assessment of nondestructive assay (NDA) measurement instruments to meet those needs was also performed. Across the board, sites indicated that personnel and budget would cause the largest impact. Sites which are qualified as Category I/II indicated a reduced impact as these sites already have the measurement capabilities and some personnel but would require the acquisition of additional measurement systems. Category III/IV sites indicated a much larger impact as these sites generally have smaller MC&A programs. A few smaller sites stated a measurement program would need to be created to handle the demand. Calorimetry, quantitative gamma spectroscopy and neutron coincidence counting systems were identified as common systems that could meet the verification measurement requirements. The other, and perhaps larger issue is the need for calibration standards for the calorimetry and neutron coincidence counting systems. It is proposed that a comparative study be performed for ISOCS and ISOTOPICS, qualification of a COTS calorimetry system be performed, and development of an AWCC system that uses a neutron generator.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Gantryless Associated-Particle Neutron Radiography

The present work reports on the development of techniques for in-field fast-neutron radiography measurements using the associated-particle imaging (API) method. The API method employs alpha-neutron coincidences from the d+t→α+n reaction to enable fast neutron transmission imaging with excellent contrast using a wide cone beam. However, for field radiography applications, the API method is burdened by the need for the relative positions of the source and detector to be known. Fortunately, these relative positions can be inferred from transmission data. The inferred positions also enable accurate stitching of multiple images into a composite image even when using a low-resolution detector panel and acquiring images having few overlapping pixels. The developed techniques address analysis of measurements where (1) the source and detector panel are separately hand positioned rather than held in registration by a gantry, (2) multiple detector panel positions within the “coincident cone” of tagged neutrons are required to piece together an image of an item of interest, and (3) normalization measurements that have identical source-detector positioning but without the inspected object are not possible. The present work will describe the system calibrations (including timing calibrations and neutron direction calibrations) necessary for subsequent analyses, the method of locating the detector in the coincident cone of neutrons with millimeter precision using the timing and directions of coincident neutrons, the method of calculating a normalization image for a given detector panel position, and the method used to project multiple images into a common image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light output quenching in response to deuterium-ions and alpha particles and pulse shape discrimination in deuterated trans-stilbene

We characterized the light output response of a new 140 cm 3 stilbene-d 12 crystal up to 14.1 MeV neutron energies using a coincidence neutron scattering system. We also characterized its light output response to alpha particles in the 5 to 6 MeV energy range. The excellent PSD capability of the stilbene-d 12 detector allowed us to select light pulses produced by particles of increasing ionization density, namely electrons, protons, deuterium-ions, and alpha particles. The measured fast decay component of the light pulses is increasingly quenched as the ionization density of the particle in the crystal increases. Consistently with this finding, the Birks’ quenching parameter of alpha particles is approximately 8.5 times larger compared to the quenching of deuterium ions, produced by neutron scattering interactions. The reported experimental characterization will allow high-fidelity modeling of the detector enabling its application for fast-neutron detection and spectroscopy in nuclear physics, radiation protection, nuclear security, and non-proliferation.

36 MATERIALS SCIENCE↗

Burnup Monitoring for Pebble Bed Reactor Systems

A pebble burnup monitoring system is a required component for domestic reactor safety and safeguards applications associated with pebble bed reactors (PBRs). One of the main requirements of a PBR burnup monitoring system is that it needs to be capable of rapid measurements to assess the burnup of each individual pebble to determine whether to recirculate it in the reactor or discard it as spent fuel. This report considers three different approaches for a burnup monitoring system for pebbles discharged from the reactor core in a pebble bed modular reactor-400: • passive gamma spectrometry measurement, • passive neutron coincidence measurement, and • active neutron counter based on the differential die-away technique. Conceptual designs have been created for each of these detectors, and preliminary analysis has been performed using Monte Carlo N-Particle and Oak Ridge Isotope Generation code simulations. The advantages and practical limitations (e.g., high radiation background) of each system were identified. Simulations suggest that each of the three measurement techniques can be successfully employed to distinguish between pebbles based on their number of passes through the core and to quantify the burnup of pebbles.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Improving Effective Mass Estimations in Pu-Metal Annuli

Determining the effective mass of 240 Pu in a plutonium metal item can be achieved through a number of destructive and non-destructive assay techniques. However, these techniques have one or more shortcomings. These include the need for large quantities of plutonium, long measurement time, or lack of sufficient accuracy. While efforts have been made to mitigate these issues by estimating 240 Pu quantities through neutron coincidence counting techniques, these estimates are subject to systematic bias, and their estimates are not well characterized when other factors of the annulus’ physical form and composition are accounted for. In this work, we expand upon these non-destructive assay techniques via the implementation of random forest machine learning models, which produce correction functions that augment and improve the effective mass estimates derived from classical leakage multiplication, singles, doubles, and triples multiplicity counting equations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of Impure Plutonium Oxide Neutron Calibration Standards through Evaluation by Neutron Multiplicity Equations

Plutonium oxide calibration standards STD4C, STD6C and STD8C have been historically used, and are currently the only MT52 standards in use, for calibration and measurement control program of Passive/Active Neutron Coincidence Counter known as PAN1 at PF-4. In this paper, previously measured high-statistics data are used in conjunction with neutron multiplicity equations to determine multiplication M and α parameter of these standards as the explicit knowledge of these parameters may allow quantification of precision and bias of accountability measurements of different material types and matrices of items.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron-neutron quasifree scattering in neutron-deuteron breakup at 10 MeV

New measurements of the neutron-neutron quasifree scattering cross section in neutron-deuteron breakup at an incident neutron energy of 10.0 MeV are reported. The experiment setup was optimized to evaluate the technique for determining the integrated beam-target luminosity in neutron-neutron coincidence cross-section measurements in neutron-deuteron breakup. The measurements were carried out with a systematic uncertainty of ± 5.6%. Our data are in agreement with theoretical calculations performed using the CD-Bonn nucleon-nucleon potential in the Faddeev formalism. The measured integrated cross section over the quasifree peak is 20.5 ± 0.5(stat) ± 1.1 (sys) mb/sr 2 in comparison with the theory prediction of 20.1 mb/sr 2 . Overall, these results validate our technique for determining the beam-target luminosity in neutron-deuteron breakup measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Updates to Relevance Vector Machine: Multiclass Classification, Variable Selection, and Proof-of-Concept Application to Safeguards Fresh Fuel Verification using List-Mode Neutron Collar Data

To expand the capabilities of safeguards authorities to verify the integrity of fresh fuel assemblies, Oak Ridge National Laboratory has retrofit the existing electronics of the JCC-71 uranium neutron coincidence collar, which contains 18 3 He neutron detectors and an external 241 AmLi(α, n) neutron interrogation source arranged to surround a fresh nuclear fuel assembly. The new electronics system allows analysts to record list-mode neutron multiplicity data in addition to the singles and doubles rates that are currently measured. Based on previous proof-of-concept research, analysis of these new data will identify off-normal fuel configurations in an assembly and characterize or localize the specific partial fuel defects. The purpose of this report it to document the analysis algorithm development and then to demonstrate its capability for the safeguards verification of fresh fuel assemblies using list mode neutron collar data. To analyze the complex list-mode data collected with the upgraded uranium neutron collar, multivariate classification algorithms are being developed using a novel classification method, the relevance vector machine. This approach may be applied to multiclass problems to estimate the probability that test data belongs to one of many possible classes of data. In addition, our method identifies the most useful variables/channels for making predictions, which illuminates the basis for the model’s predictions, and this interpretability is largely unique among data analytics methods. Variable selection occurs during model training and parameter tuning and does not need any external hyperparameter tuning routines. Finally, we apply the modified relevance vector machine to a simulated dataset of list-mode neutron collar data generated with the radiation transport code MCNP. The method can correctly identify off-normal fuel configurations, categorize the data according to four fuel defect scenarios, and rank the channels in the data according to prediction utility. For nuclear safeguards applications, it is concluded that this method has the potential to increase the sensitivity and reliability to detect missing fuel rods from a standard 17 x 17 Pressurized Water Reactor (PWR) fresh fuel assembly. Within this analysis, “off-normal” (i.e., missing fuel rods) were correctly classified in 17 simulated test scenarios with one quarter (25%) of the fresh fuel rods missing using a training data set of 58 simulated measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Incorporating the latest Neutron NDA analysis techniques into INCC6

International Neutron Coincidence Counting (INCC6) is the IAEA’s neutron NDA software. With FY25 SGTech support we implemented self-diagnostic features into INCC6. For FY26 we propose to implement advanced analysis methods that have been splintered into custom software for one-off instruments. Incorporating these capabilities in INCC6 will make them available for any new or existing application on the ubiquitous INCC6 platform, increasing safeguards efficiency and effectiveness.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AWCC Simulations

Neutron well counters provide a means to measure fissile mass by detecting coincident neutrons, which is a unique signature to fission. For coincidence counting, mass is determined using a calibration curve established with items that have the same material characteristics. Multiplicity analysis solves the point model equations for mass using known detector parameters. In both cases, mass measurements may exhibit a bias due to item characteristics and should be corrected for. Experiments can be done to estimate bias and material effects, but they require having both the well counter and the material well defined. In pursuit of estimating measurement bias and uncertainty in a High Efficiency Neutron Counter (HENC), an MCNP simulation was matched to measurements performed with an Active Well Coincidence Counter (AWCC) to de ne a neutron source term. The neutron source term will be used to predict measurement performance of similar material types in a HENC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Evaluation of a Neutron Time Correlated Interrogation Method for Measurement of Fissile Content in Research Reactor Spent Fuel Assemblies

There are many research reactors worldwide that have been, or are being converted from the use of high enrichment uranium (HEU) to low enrichment uranium (LEU, < 20% enriched). The verification of fissile content and initial enrichment of the spent fuel is needed for the effective safeguards of the fuel. The advanced experimental fuel counter (AEFC) was developed for the measurement of spent fuel rods and assemblies from research reactors for safeguards verification. This measurement system contains components for active neutron interrogation, passive neutron totals counting, neutron coincidence counting, and gross gamma-ray counting. This report presents the first application of the time correlated interrogation technique for the measurement of the 235 U content in research reactor spent fuel assemblies. The technique, called time correlated induced fission (TCIF), uses a 252 Cf neutron source to irradiate the fuel assembly, and the subsequent induced fission events in the fissile material are measured by coincidence counting. The doubles rates are enhanced by having the neutron trigger events from both the 252 Cf source and the induced fission neutrons in the same time gate in the coincidence analysis. The average neutrons per fission of the 252 Cf source is 3.76 and the induced fission neutrons for 235 U is 2.44, so the number of neutrons that are produced is higher than for random neutron interrogation. This high effective neutron number increases the multiplicity counting rates and reduces the statistical error. The background coincidence counts from the 252 Cf are reduced by the water in the sample cavity and the polyethylene surrounding the 3 He detector tubes. This method of active neutron interrogation has been applied to the measurement of spent research reactor (IRT) fuel assemblies. The advanced experimental fuel counter (AEFC) was used to compare the TCIF method with the typically used AmLi neutron interrogation source that emits neutrons that are random in time. The statistical uncertainty for the use of the random neutron source (AmLi) and the time correlated source ( 252 Cf) for spent fuel interrogations was evaluated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Verification of Special Nuclear Material (SNM) using Active Well Coincidence Counter (AWCC) and a High Purity Germanium (HPGe) Detector

SNM verification can be accomplished via two methods i.e. destructive analysis (DA) or nondestructive analysis (NDA). The DA modes are much more accurate compared to NDA modes; nevertheless, the sample's physical integrity is destroyed in the process. Techniques such as ICP-MS, ID-ICP-MS, TI-MS are few examples of DA, where a bulk material is ground and mixed with a solution (some form of acid) to acquire a homogenous sample. In contrast, NDA modes utilize signals emitted by the sample such as gamma, neutrons, light, or heat to analyze samples under investigation. HPGe detectors are some of the most frequently used gamma detectors to assay SNM. However, in a high activity scenario it provides a large uncertainty and sometimes becomes unfeasible to measure low energy gamma rays. Meanwhile, neutron detectors are not affected by the gamma background, therefore they can be used in addition to the gamma detectors to verify total fissile mass ({sup 235}U + {sup 239}Pu) of SNM. The AWCC is one of the thermal neutron NDA systems developed at the Los Alamos National Laboratory (LANL). It consists of 42 {sup 3}He detectors to measure gross neutrons (singles), coincidence neutrons (doubles), higher order multiplicity counting (triples, quadruples, etc.). It can effectively operate in both active and passive neutron interrogation modes. It can utilize AmLi, AmBe, or {sup 252}Cf active interrogation neutron sources. It is used to verify declared fissile mass ({sup 235}U or {sup 239}Pu) present in SNM. Objectives: Calibrate HPGe and AWCC for lightly irradiated (with enough {sup 137}Cs gamma background) ∼93% enriched HEU fuels; Verify fissile mass ({sup 235}U +{sup 239}Pu) content using AWCC and HPGe; Model and benchmark AWCC in MCNP6. Neutron coincidence and multiplicity counting: Two or more neutrons are coincident if they are detected by the system within the specified gate window; In AWCC: Gate window is 128 μsec; Induced fission in fissile material such as {sup 235}U and {sup 239}Pu - emission of time correlated neutrons - Singles, Doubles, Triples, or Quadruples; No induced fission in non-fissile materials- no correlated neutrons - only singles. SNM can be verified with high accuracy and precision using gamma and neutron NDA instruments such as HPGe and AWCC. Interaction with thermal neutrons. Non-fissile atoms - do not emit correlated neutrons. Fissile atoms - emit correlated neutrons during induced fission events. The time correlated neutrons can be detected by using coincidence or multiplicity counters such as AWCC. Likewise, {sup 235}U produces 186 keV gamma peak that can be measured by a HPGe gamma detector. Counts under 186 keV gamma peak provide information about {sup 235}U content. Combining AWCC and HPGe results can provide better understanding of special nuclear material under investigation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Polyethylene density uncertainty in the simulation of neutron detectors

Simulations with the Monte Carlo N-Particle® (MCNP®) code are frequently used to study neutron coincidence counters for international safeguards. Reducing sources of uncertainty enables more accurate simulations, which reduces the need for expensive or impossible measurements. Accurately specifying the density of polyethylene is crucial for accurate simulations. The density of polyethylene ranges from 0.88 to 0.97 g/cm 3 and high-density polyethylene (HDPE) ranges from about 0.944 to 0.965 g/cm 3 . The density of a specific detector should be measured exactly for the best simulations. Here, the density of the blue/white Active Well Coincidence Counter (AWCC) bulk polyethylene was measured to be 0.9594 +- 0.0013 g/cm 3 at 1-sigma confidence. The density was calculated from repeated measurements of the various polyethylene dimensions for volume, and weighing the polyethylene for the mass. The AWCC neutron detection efficiency was simulated for each polyethylene density. The relative range of efficiencies (3σ) was 3.4% for unspecified polyethylene, 0.9% for HDPE, and 0.3% for the measured density. The impact of modeling small features such as screws was also studied and was found to be a negligible 0.2%. Measuring polyethylene density can reduce its role in uncertainty from one of the largest to one of the smallest contributors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Integrated Approach to Precision Neutron Measurements in a Dynamic Environment [Slides]

Any quantity of special nuclear material must be accurately quantified for health, safety, and security concerns. High-Level Neutron Coincidence Counters (HLNCCs) are detectors used for assaying the mass of special nuclear material. HLNCCs record a neutron count rate over some period of time which is compared to a calibration curve to determine the quantity of special nuclear material present within the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First (p,n) reaction measurement in inverse kinematics with SECAR

Nucleosynthesis in the νp-process occurs in regions of slightly proton-rich nuclei in the neutrino-driven wind of core-collapse supernovae. The process proceeds via a sequence of (p,γ) and (n,p) reactions, and depending on the conditions, may produce elements between Ni and Sn. Recent studies show that a few key (n,p) reactions regulate the efficiency of the neutrino-p process (νp-process). We performed a study of one of such (n,p) reactions via the measurement of the reverse (p,n) in inverse kinematics with SECAR at NSCL/FRIB.Such proton-induced reaction measurements are particularly challenging, as the recoils and the unreacted projectiles have nearly identical masses. An appropriate separation level can be achieved with SECAR, and along with the incoincidence detection of neutrons these measurements become attainable. The preparation of the SECAR system for accommodating its first (p,n) reaction measurement, including the development of alternative ion beam optics, and the setup of the in-coincidence neutron detection, along with discussion on preliminary results from the p(58Fe,n)58Co reaction measurement are presented and discussed.

Tsintari, P↗

Examination of Digital-Delay Rossi-$\alpha$ for 252 Cf-Driven Highly Enriched Uranium Using Organic Scintillators

Neutron noise techniques constitute several analysis methods applicable to non-destructive assay. One technique is the Rossi-α method to calculate the prompt neutron decay constant (α) or its inverse, the prompt neutron period (1/α), for assemblies of fissionable material. This work evaluates a high-data-throughput measurement at the National Criticality Experiments Research Center (NCERC) with organic scintillators measuring a subcritical assembly of highly enriched uranium (HEU) metal (93% 235 U). The assembly comprises hemi shells stacked together to form fully closed shells and is driven by a Cf source at the center. The assembly is a total of 59.85 kg HEU and a k eff of 0.99, according to MCNP6.2 KCODE simulations. Measurements were acquired with a three-by-four array of 5.08-cm-diameter by 5.08-cm-length trans-stilbene crystals 166 cm from the assembly center. Two types of coincident binning methods are used to build the Rossi-α distribution of coincident neutron detections: A) type 1 binning, also known as any-and-all forward time differences, and B) type 1 binning with a digital-delay technique that is analogous to Orndoff’s use of delay cabling in early Rossi-alpha measurements. Method B) disregards same-detector coincidences and once all nearest time coincidences are collected between all detectors after a trigger, a time delay of 0.75 µs is implemented. The measured prompt neutron decay constants for both techniques are calculated from single exponential fits and the two methods are compared. Method A) shows an apparent timing discontinuity near 500 ns time differences. This timing discontinuity interferes with the fitting method used to calculate the prompt neutron decay constant. Method B) mitigates the artificial timing discontinuity and removes the disagreement of the fit. Future work will model the time-dependent detector response to discern why this timing discontinuity occurs, discern how Method B) reduces the amplitude of this timing discontinuity, and apply this method to critical assembly measurements to ultimately confirm the recommendation to use Method B) for high-data-throughput measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of INCC6 for advanced list-mode data acquisition and analysis using ALMM

The International Neutron Coincidence Counting (INCC) software plays an important role in nuclear safeguards and nuclear material control and accounting (NMC&A) measurements. While the current version, INCC5, represents the traditional standard utilized by inspectorates as well as facilities and practitioners alongside shift register hardware, LANL has recently developed an upgraded version of the software, INCC6. INCC6 offers the same analysis tools as INCC5 while adding new capabilities including acquisition and analysis of list-mode data, recording and storage of list-mode data files, and an expanded set of advanced analysis tools that make use of the additional information available from list-mode data. Here, this paper presents the first demonstration of data acquisition and analysis using INCC6 and the Advanced List Mode Multiplicity Module (ALMM). The capability of INCC6 to perform live list-mode data acquisition and analysis is demonstrated for a variety of neutron sources with a range of neutron emission rates relevant for practical applications and validated against the results obtained with INCC5 and traditional shift register hardware. Advanced list-mode analysis tools introduced by INCC6, such as time-interval and coincidence matrix analysis, are also demonstrated. Finally, the capability of INCC6 to analyze list-mode data files is tested and validated against traditional shift register results using INCC5.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision Measurements of the Neutron Magnetic Form Factor to High Momentum Transfer using Durand's Method

Protons and neutrons, collectively known as nucleons, along with electrons, constitute the funda- mental building blocks of the visible universe. Understanding their internal structure is crucial for addressing key scientific questions about our origin and existence. Elastic electron-nucleon scatter- ing provides insights into the spatial distributions of charge and current within nucleons through their electromagnetic form factors. Accurate knowledge of these form factors over a broad range of Q2, the squared four-momentum transfer in the scattering process, reveals details about the nucleon’s internal structure. However, high-Q2 data of the nucleon electromagnetic form factor is scarce due to the challenges associated with such measurements. This thesis reports preliminary results from high-precision measurements of the neutron magnetic form factor (Gn M ) to unprecedented Q2 using Durand’s method, also known as the “ratio” method. Systematic errors are greatly reduced by extracting Gn M from the ratio of neutron-coincident (D(e, e'n)) to proton-coincident (D(e, e'p)) quasi-elastic electron scattering from deuteron. The scattered electrons were detected in the BigBite spectrometer, which features multiple Gas Elec- tron Multiplier (GEM) layers with large active area for high-precision tracking at very high rates. Simultaneous nucleon detection was performed by the Super BigBite spectrometer, which utilizes a dipole magnet with large solid angle acceptance at forward angles and a novel hadron calorimeter with very high and comparable detection efficiencies for both protons and neutrons. This setup could handle very high luminosity, making high-Q2 measurements feasible. Data were collected at five Q2 points: 3, 4.5, 7.4, 9.9, and 13.6 (GeV/c)2. Preliminary results are reported for all, with the lowest two Q2 points in good agreement with existing world data, while the higher points significantly extend the Q2 range in which Gn M is known accurately. The precision of the highest Q2 point is expected to remain unmatched for years to come.

Datta, Provakar↗