In-Core Irradiation Capabilities at the Neutron Radiography Reactor
In-Core Irradiation Capabilities at the Neutron Radiography Reactor is a canned presentation for prospective researchers interested in performing irradiations at NRAD.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
In-Core Irradiation Capabilities at the Neutron Radiography Reactor is a canned presentation for prospective researchers interested in performing irradiations at NRAD.
Chemical movement through soil is an important process in agriculture and ecology. Observing the spatial and temporal dynamics of these processes using conventional chemical ecology methods requires techniques that are destructive and/or lack resolution. Neutron radiography has the capability to allow chemical motion through sand/soil to be tracked with high spatial and temporal resolution, and we show that it allows for the motion of hydrophobic and hydrophilic chemicals to be distinguished. This technique can have an important impact on introducing neutron radiography to a wider community and into our understanding of chemical communication dynamics between plants and movement of applied chemicals in agricultural soils.
The preliminary results of hyperspectral neutron radiography of Si–SiC made with binder jet additive manufacturing, subsequent carbon addition, and silicon melt infiltration are presented. The samples were measured in the processing states before and after the melt infiltration to determine if neutrons would help characterize the microstructure to better understand the melt infiltration process. Theoretical Bragg edges were calculated for comparison with the radiographic results. The changes in the Bragg edges from pre- to post-infiltrated reaction-bonded SiC were evident, that could be used to address the differences in microstructures. In conclusion, the preliminary results presented in this study demonstrated that neutron Bragg-edge imaging is possible with Si–SiC reaction-bonded ceramics and can help determine the microstructure of melt infiltrated samples.
The present work reports on the development of techniques for in-field fast-neutron radiography measurements using the associated-particle imaging (API) method. The API method employs alpha-neutron coincidences from the d+t→α+n reaction to enable fast neutron transmission imaging with excellent contrast using a wide cone beam. However, for field radiography applications, the API method is burdened by the need for the relative positions of the source and detector to be known. Fortunately, these relative positions can be inferred from transmission data. The inferred positions also enable accurate stitching of multiple images into a composite image even when using a low-resolution detector panel and acquiring images having few overlapping pixels. The developed techniques address analysis of measurements where (1) the source and detector panel are separately hand positioned rather than held in registration by a gantry, (2) multiple detector panel positions within the “coincident cone” of tagged neutrons are required to piece together an image of an item of interest, and (3) normalization measurements that have identical source-detector positioning but without the inspected object are not possible. The present work will describe the system calibrations (including timing calibrations and neutron direction calibrations) necessary for subsequent analyses, the method of locating the detector in the coincident cone of neutrons with millimeter precision using the timing and directions of coincident neutrons, the method of calculating a normalization image for a given detector panel position, and the method used to project multiple images into a common image.
We report the system response of a pixelated associated particle imaging (API) neutron radiography system. The detector readout currently consists of a 2x2 array of organic glass scintillator detectors, each with an 8x8 array of optically isolated pixels that match the size and pitch of the ARRAYJ-60035-64P-PCB Silicon Photomultiplier (SiPM) array from SensL/onsemi with 6x6 mm 2 SiPMs. The alpha screen of the API deuterium-tritium neutron generator is read out with the S13361-3050AE-08 from Hamamatsu, which is an 8x8 array of 3x3 mm 2 SiPMs. Data from the 320 channel system is acquired with the TOFPET2-based readout system. We present the predicted imaging capability of an eventual 5x5 detector array, the waveform-based energy and pulse shape characterization of the individual detectors, and the timing and energy response from the TOFPET2 system.
Neutrons have historically been used for a broad range of biological applications employing techniques such as small-angle neutron scattering, neutron spin echo, diffraction, and inelastic scattering. Unlike neutron scattering techniques that obtain information in reciprocal space, attenuation-based neutron imaging measures a signal in real space that is resolved on the order of tens of micrometers. The principle of neutron imaging follows the Beer-Lambert law and is based on the measurement of the bulk neutron attenuation through a sample. Greater attenuation is exhibited by some light elements (most notably, hydrogen), which are major components of biological samples. Contrast agents such as deuterium, gadolinium, or lithium compounds can be used to enhance contrast in a similar fashion as it is done in medical imaging, including techniques such as optical imaging, magnetic resonance imaging, X-ray, and positron emission tomography. For biological systems, neutron radiography and computed tomography have increasingly been used to investigate the complexity of the underground plant root network, its interaction with soils, and the dynamics of water flux in situ. Moreover, efforts to understand contrast details in animal samples, such as soft tissues and bones, have been explored. This manuscript focuses on the advances in neutron bioimaging such as sample preparation, instrumentation, data acquisition strategy, and data analysis using the High Flux Isotope Reactor CG-1D neutron imaging beamline. The aforementioned capabilities will be illustrated using a selection of examples in plant physiology (herbaceous plant/root/soil system) and biomedical applications (rat femur and mouse lung).
Advances in flat-panel radiography device design have increased the use of radiation imaging as a nondestructive evaluation tool. Neutron radiography offers many advantages compared to photon-based radiography.
Extensive experimental research on high-pressure spray has been conducted for decades to deepen our understanding and optimize its use in transportation, aviation, and propulsion applications; however, the near-field and in-nozzle flow characteristics are not fully understood. Dense near-field spray is among the most challenging diagnostic tasks since light is severely scattered and diffused by the liquid droplets and columns. In this work, the near-field spray and in-nozzle flow characteristics of an aeration nozzle at elevated pressures were characterized by neutron radiography imaging at the Oak Ridge National Laboratory High Flux Isotope Reactor. Neutron imaging benefits via strong penetration depths for some metals (i.e., aluminum, lead, and steel) and is sufficiently sensitive to detection of light elements, especially for hydrogen-based molecules, due to the large incoherent scattering cross section of neutrons. Both two-dimensional snapshots of the near-field spray and a three-dimensional tomographic scan of the nozzle geometry and in-nozzle water were obtained. This work provides new quantitative characterization of practical metal nozzle geometry for accurate boundary conditions, internal flow patterns inside the nozzle, and high-pressure spray flows. In conclusion, the findings may be used to improve performance and operating conditions of transportation vehicles and propulsion systems.
The Sustaining and Enhancing Nuclear Science Initiative at Oak Ridge National Laboratory (ORNL) was created to explore potential enhancements to scientific capabilities in the High Flux Isotope Reactor as part of a reactor pressure vessel replacement project. One proposed scientific enhancement included creation of an epithermal and fast neutron radiography station on the HB-3 beam tube with the capability to image highly radioactive specimens such as irradiated nuclear fuel rods, isotope production targets, or spallation neutron target materials. This document summarizes findings and recommendations from a working group of ORNL staff tasked with conceptualizing such a facility and includes a background of similar instruments at other research facilities, technical specifications, and an estimate of procurement cost and schedule.
Tortuosity-weighted interfacial flux for lithium (TWIF-Li) predicts through-thickness Li gradients in thick composite all-solid-state cathodes without fitted parameters. Image-derived microstructures, GITT-derived concentration-dependent solid diffusion, and tortuosity-weighted interfacial kinetics reproduce operando neutron radiography across practical rates, delivering transferable design rules to suppress transport-limited reaction fronts.
Explore the source record for details and available documents.
Material identification (ID) using radiography is a problem that has implicitly existed since the discovery of the X-ray. Since 9-11, this problem has received renewed attention for homeland security applications of the generic, “what is in the box?” type1. Examples of items potentially in the box include: roadside bombs, nuclear weapons, contraband shipments and the like. In these cases, the “what” can include: explosives, projectiles, fissile material, or drugs. Here we investigate the ability of 60Co gamma-rays, 14MeV neutrons, and their combination to tease apart information about density, thickness and atomic number of items in the box. That information subset can be combined with other types of independent information (e.g. neutron and gammaspectroscopy, intelligence, photographs etc.) to assert a more complete picture of what, exactly, is in the box? That more complete information set can form the basis for actions including: remote detonation, evacuations, disablement, detention, search, arrest etc.
The densities of eutectic (LiF) 2 –BeF 2 and mixtures of this salt (FLiBe) with LaF 3 were measured by dilatometry and by neutron attenuation from 673 K to 1,073 K. Because LaF 3 has a limited solubility in FLiBe, it was necessary to determine the amount of LaF 3 in solution before the density could be determined. The FLiBe density determination was favorably benchmarked against the literature data. A simple comparison was not available for the LaF 3 –FLiBe mixtures, so extrapolation of published data was necessary based on analysis using the Molten Salt Thermal Properties Database-Thermochemistry, or MSTDB-TC, developed by the US Department of Energy. Solubilities for LaF 3 in FLiBe ranged from 1 to 4 mol % over 673 to 1,073 K. The salt system was heated and cooled over 24 h to evaluate potential changes in composition and hysteresis during the measurement. Changes in the meniscus were observed, and these were included in the correction for density determinations. Salt surface tension may have led to supersaturation of LaF 3 in the salt because the solubility curve was nonlinear with respect to the inverse temperature, as would be expected for an ideal system. Surface tension measurements are currently underway to test this hypothesis.
Abstract The continued advancement of electrochemical technologies requires an increasingly detailed understanding of the microscopic processes that control their performance, inspiring the development of new multi-modal diagnostic techniques. Here, we introduce a neutron imaging approach to enable the quantification of spatial and temporal variations in species concentrations within an operating redox flow cell. Specifically, we leverage the high attenuation of redox-active organic materials (high hydrogen content) and supporting electrolytes (boron-containing) in solution and perform subtractive neutron imaging of active species and supporting electrolyte. To resolve the concentration profiles across the electrodes, we employ an in-plane imaging configuration and correlate the concentration profiles to cell performance with polarization experiments under different operating conditions. Finally, we use time-of-flight neutron imaging to deconvolute concentrations of active species and supporting electrolyte during operation. Using this approach, we evaluate the influence of cell polarity, voltage bias and flow rate on the concentration distribution within the flow cell and correlate these with the macroscopic performance, thus obtaining an unprecedented level of insight into reactive mass transport. Ultimately, this diagnostic technique can be applied to a range of (electro)chemical technologies and may accelerate the development of new materials and reactor designs.
The development of the pore structures of hardened Portland/slag cement pastes for sample ages up to 1 year, and the absorption of moisture through these pores, are monitored and quantified using X-ray and neutron techniques.
Not Available
Conclusions: Elements other than detector array can heavily impact performance; Must consider a variety of alterations to an imaging array to determine an optimal system.