Search NASA⌕ Search

SEARCH · Search NASA

Results for “Normal conducting radio-frequency acceleration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

22 records · Page 2

Cascading RF deflectors in compact beam spreader schemes

This study describes beam distribution schemes based on transverse electric field radio-frequency deflectors (RFD) as fast-switching devices and provides numerical relationships between their respective frequencies and phases. The adoption of compact transverse deflecting cavities represents an ideal solution for the design of high repetition rate ( > 1 MHz), compact beam distribution systems. While directly applicable to modern FEL facilities, this approach also provides opportunities for expanding existing beam delivery systems with additional experimental areas simultaneously feeding multiple beamlines. We derive the formalism for cascading RFDs by adopting the proper choice of deflector frequencies which can generate a large variety of beam switch yard topologies. Finally, we present for reference a potential application operating at an rf frequency of 325 MHz with the comparison of three possible distinct compact rf deflectors: a superconducting rf-dipole, a normal conducting rf-dipole, and a normal conducting 4-rod design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ka-band linearizer for the Ultra-Compact X-ray free-electron laser at UCLA

There is a strong demand for accelerating structures able to achieve higher gradients and more compact dimensions for the next generation of linear accelerators for research, industrial and medical applications. Notably innovative technologies will permit compact and affordable advanced accelerators as the linear collider and X-ray free-electron lasers (XFELs) with accelerating gradients over twice the value achieved with current technologies. In particular XFELs are able to produce coherent X-ray pulses with peak brightness 10 orders of magnitude greater than preceding approaches, which has revolutionized numerous research fields through imaging of the nanoscopic world at the time and length scale of atom-based systems, that is of femtosecond and Angstrom. There is a strong interest for combining these two fields, to form a proper tool with the goal of producing a very compact XFEL in order to investigate multi-disciplinary topics in chemistry, biology, materials science, medicine and physics. In the framework of the Ultra-Compact XFEL project under study at the University of California, Los Angeles, a high gradient radio-frequency accelerating structure for the longitudinal phase-space linearization with an integrated voltage of at least 15 MV working on 6th harmonic of the main Linac frequency is required. We here present the electromagnetic design of a cryogenic normal-conducting 8 cm long Ka-band standing-wave linearizer working on π mode with a target accelerating gradient beyond 100 MV/m. The studies have been performed analytically and numerically to investigate the beam dynamics and electromagnetic issues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of extremum seeking for time-varying systems to resonance control of RF cavities

A recently developed form of extremum seeking for time-varying systems is implemented in hardware for the resonance control of radio-frequency cavities without phase measurements. Normal conducting RF cavity resonance control is performed via a slug tuner, while superconducting TESLA-type cavity resonance control is performed via piezo actuators. The controller maintains resonance by minimizing reflected power by utilizing model-independent adaptive feedback. Unlike standard phase-measurement-based resonance control, the presented approach is not sensitive to arbitrary phase shifts of the RF signals due to temperature-dependent cable length or phasemeasurement hardware changes. The phase independence of this method removes common slowly varying drifts and required periodic recalibration of phase-based methods. A general overview of the adaptive controller is presented along with the proof of principle experimental results at room temperature. Lastly, this method allows us to both maintain a cavity at a desired resonance frequency and also to dynamically modify its resonance frequency to track the unknown time-varying frequency of an RF source, thereby maintaining maximal cavity field strength, based only on power-level measurements.

47 OTHER INSTRUMENTATION↗

Investigation of Frequency Behavior Near Tc of Niobium Superconducting Radio-Frequency Cavities

This paper will present a systematic investigation of the resonant frequency behavior of niobium SRF cavities subject to different surface processing (nitrogen doping, nitrogen infusion, 120°C bake, EP, etc.) near the critical transition temperature. We find features occurring in frequency versus temperature (FvsT) data near Tc that seem to vary with surface processing. Emphasis is placed on one of the observed features: a dip in the superconducting resonant frequency below the normal conducting value which is prominent in nitrogen doped cavities and appears to be a signature of nitrogen doping. This gives further insights on the mechanisms responsible for the large increase in performance of cavities subject to this surface treatment. The magnitude of this dip in frequency is studied and related to possible physical parameters such as the concentration of impurities near the surface and the design resonant frequency of the cavity. A possible explanation for the meaning of this dip is discussed, namely, that it is a result of strong coupling between electrons and phonons within the resonator.

43 PARTICLE ACCELERATORS↗