Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear physics instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The High-Altitude Water Cherenkov (HAWC) observatory in México: The primary detector

The High-Altitude Water Cherenkov (HAWC) observatory is a second-generation continuously operated, wide field-of-view, TeV gamma-ray observatory. The HAWC observatory and its analysis techniques build on experience of the Milagro experiment in using ground-based water Cherenkov detectors for gamma-ray astronomy. HAWC is located on the Sierra Negra volcano in México at an elevation of 4100 meters above sea level. The completed HAWC observatory principal detector (HAWC) consists of 300 closely spaced water Cherenkov detectors, each equipped with four photomultiplier tubes to provide timing and charge information to reconstruct the extensive air shower energy and arrival direction. The HAWC observatory has been optimized to observe transient and steady emission from sources of gamma rays within an energy range from several hundred GeV to several hundred TeV. However, most of the air showers detected are initiated by cosmic rays, allowing studies of cosmic rays also to be performed. This paper describes the characteristics of the HAWC main array and its hardware.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation-hard miniature optical engine with high bandwidth

Future silicon trackers will be operated in an intense radiation environment and require large volumes of data to be transmitted off detector. In addition, the optical modules must be of low mass in order to limit multiple scattering and nuclear interactions that would degrade the overall performance of the detector. Here, we present a miniature optical engine that satisfies these constraints. The optical engine consists of an ASIC driving a VCSEL (Vertical Cavity Surface Emitting Laser) array in an optical package. Two ASICs are designed to operate a 12-channel VCSEL array at 1.28 or 5.12 Gb/s per channel, which yields a total data rate of up to 60 Gb/s. The core transistors are fabricated in a 65 nm CMOS process which enhance the radiation-hardness. Each channel contains equalizer (CTLE) and clock-data recovery circuits (CDR) so that the ASIC can restore the highly distorted electrical signal after propagating through several meters of cables of small diameter. The equalizer, CDR, and VCSEL driver are configured via a digital I 2 C chip interface with triple redundant memory to mitigate single event upset (SEU) effects. The bias and modulation currents are controlled by a digital-to-analog converter (DAC). We present the design of the circuit together with the results of the simulations and preliminary measurements.

47 OTHER INSTRUMENTATION↗

State-of-the-art and evolution of UFSD sensors design at FBK

Over the past few years, there has been growing interest in the development of silicon sensors able to simultaneously measure accurately the time of passage and the position of impinging charged particles. In this contribution, a review of the progresses in the design of UFSD (Ultra-Fast Silicon Detectors) sensors, manufactured at the FBK (Fondazione Bruno Kessler) Foundry, aiming at tracking charged particles in 4 dimensions, is presented. The state-of-the-art UFSD sensors, with excellent timing capability, are planned to be used in both ATLAS and CMS experiments detector upgrade, in order to reduce the background due to the presence of overlapping events in the same bunch crossing. The latest results on sensors characterization including time resolution, radiation resistance and uniformity of the response are here summarized, pointing out the interplay between the design of the gain layer and the UFSD performances. The research is now focusing on the maximization of the sensor fill factor, to be able to reduce the pixel size, exploring the implementation of shallow trenches for the pixel isolation and the development of resistive AC-coupled UFSD sensors. In conclusion, a brief review on research paths tailored for detection of low energy X-rays or for low material budget applications is given.

47 OTHER INSTRUMENTATION↗

Humidity sensitivity of large area silicon sensors: Study and implications

The production of large area sensors is one of the main challenges that the ATLAS collaboration faces for the new Inner-Tracker full-silicon detector. During the prototype fabrication phase for the High Luminosity Large Hadron Collider upgrade, several ATLAS institutes observed indications of humidity sensitivity of large area sensors, even at relative humidities well below the dew point. Specifically, prototype Barrel and End-Cap silicon strip sensors fabricated in 6-inch wafers manifest a prompt decrease of the breakdown voltage when operating under high relative humidity, adversely affecting the performance of the sensors. In addition to the investigation of these prototype sensors, a specific fabrication batch with special passivation is also studied, allowing for a deeper understanding of the responsible mechanisms. Here we present an extensive study of this behaviour on large area sensors. The locations of the hotspots at the breakdown voltage at high humidity are revealed using different infrared thermography techniques. Several palliative treatments are attempted, proving the influence of sensor cleaning methods, as well as baking, on the device performance, but no improvement on the humidity sensitivity was achieved. Furthermore, a study of the incidence of the sensitivity in different batches is also presented, introducing a hypothesis of the origins of the humidity sensitivity associated to the sensor edge design, together with passivation thickness and conformity. Several actions to be taken during sensor production and assembly are extracted from this study, in order to minimize the impact of humidity sensitivity on the performance of large area silicon sensors for High Energy Physics experiments.

47 OTHER INSTRUMENTATION↗

Reflectivity and PDE of VUV4 Hamamatsu SiPMs in liquid xenon

Considering reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE . Little information is currently available about reflectivity and PDE in liquid noble gases, because such measurements are difficult to conduct in a cryogenic environment and at short enough wavelengths. Here we report a measurement of specular reflectivity and relative PDE of Hamamatsu VUV4 silicon photomultipliers (SiPMs) with 50 μ m micro-cells conducted with xenon scintillation light ( ~ 175 nm) in liquid xenon. The specular reflectivity at 15 o incidence of three samples of VUV4 SiPMs is found to be 30.4 ± 1.4%, 28.6 ± 1.3%, and 28.0 ± 1.3%, respectively. The PDE at normal incidence differs by ± 8% (standard deviation) among the three devices. The angular dependence of the reflectivity and PDE was further measured for one of the SiPMs. Both the reflectivity and PDE decrease as the angle of incidence increases. This is the first measurement of an angular dependence of PDE and reflectivity of a SiPM in liquid xenon.

47 OTHER INSTRUMENTATION↗

Quality Assurance methodology for the ATLAS Inner Tracker strip sensor production

The production of the strip sensors for the ATLAS Inner Tracker (ITk) will start in 2020. Nearly 22,000 large area sensors will be produced over a period of about five years by Hamamatsu Photonics K.K. (HPK). The institutes involved in the sensor development and production are committed to deliver and maintain the highest quality sensors for the experiment. A Quality Assurance (QA) strategy has been prepared to be carried out during the whole production period. Once the process has been characterized as providing the required pre-irradiation specifications and the proper radiation hardness, the onus is on the manufacturer to rigidly stick to that qualified process. Still, sample testing with specific device-element structures and irradiation of devices should be implemented by the ITk sensor collaboration. A detailed irradiation and testing plan has been prepared by the ATLAS-ITk Collaboration, together with a newly designed test chip with specific structures to monitor different key technological and device parameters during the whole production. The tests and irradiations will be carried out on a sample basis. In order to have a practical methodology, samples from alternating batches will be sent for irradiations with protons, neutrons and gammas, and then tested in order to check that the characteristics remain within specifications. Here we present the detailed plan and the design and test methods for the structures in the test chip.

47 OTHER INSTRUMENTATION↗

Characterization and pulse-shape discrimination of a multi-stacked structure of ZnS: Ag/PMMA for fast-neutron detection in high-flux environments

The Micro-Layered Fast Neutron Detector (MLFD) is a proton-recoil scintillator that incorporates the basic concept of a Hornyak button detector with an improved design using a layered structure of ZnS:Ag and PMMA (polymethyl methacrylate). The MLFD was predicted to have low sensitivity to gamma rays, hence pulse shape discrimination was performed to determine the gamma-ray contribution. Presented in this paper are the pulse-shape discrimination characteristics of the MLFD. Additionally, the charge integration technique was employed to discriminate between the neutrons and gamma rays using a fast digitzer. The MLFD was found to exhibit excellent neutron/gamma-ray discrimination, with the highest Figure-of-Merit (FoM) being 4.56. With PSD, the neutron signal is distinct from gamma-ray, Ĉerenkov and electronic noise signals. This clear separation was achieved due to the large differences in decay times of the neutron and gamma-ray-induced pulses in the ZnS:Ag phosphor. The MLFD can be employed in high gamma-ray exposure fields, up to at least 1287.7 mR/hr, without appreciable degradation in PSD performance.

47 OTHER INSTRUMENTATION↗

Observation of Hydrodynamic Flows in Imploding Fusion Plasmas on the National Ignition Facility [plus supplemental information]

Inertial confinement fusion implosions designed to have minimal fluid motion at peak compression often show significant linear flows in the laboratory, attributable per simulations to percent-level imbalances in the laser drive illumination symmetry. In this work, we present experimental results which intentionally varied the mode 1 drive imbalance by up to 4% to test hydrodynamic predictions of flows and the resultant imploded core asymmetries and performance, as measured by a combination of DT neutron spectroscopy and high-resolution x-ray core imaging. Neutron yields decrease by up to 50%, and anisotropic neutron Doppler broadening increases by 20%, in agreement with simulations. Furthermore, a tracer jet from the capsule fill-tube perturbation that is entrained by the hot-spot flow confirms the average flow speeds deduced from neutron spectroscopy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation hardness of the low gain avalanche diodes developed by NDL and IHEP in China

This paper presents a study on the radiation hardness of low gain avalanche detector (LGAD) developed by the Novel Device Laboratory (NDL) in Beijing and the Institute of High Energy Physics (IHEP) of Chinese Academy of Sciences, in the context of an upgrade project of the ATLAS detector for the high luminosity phase of LHC. NDL LGAD sensors with different layouts, epitaxial resistivity and doping profile were irradiated up to 1.02 × 10 15 n eq /cm 2 by 70 MeV protons at Cyclotron and Radioisotope Center (CYRIC). The timing resolution of NDL LGAD sensors reached 50 ps and the collected charge reached 3 - 4 fC after irradiation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-energy micrometre-scale pixel direct conversion X-ray detector

The objective of this work was to fabricate and characterize a new X-ray imaging detector with micrometre-scale pixel dimensions (7.8 µm) and high detection efficiency for hard X-ray energies above 20 keV. A key technology component consists of a monolithic hybrid detector built by direct deposition of an amorphous selenium film on a custom designed CMOS readout integrated circuit. Characterization was carried out at the synchrotron beamline 1-BM-B at the Advanced Photon Source of Argonne National Laboratory. The direct conversion detector demonstrated micrometre-scale spatial resolution with a 63 keV modulation transfer function of 10% at Nyquist frequency. In addition, spatial resolving power down to 8 µm was determined by imaging a transmission bar target at 21 keV. X-ray signal linearity, responsivity and lag were also characterized in the same energy range. Finally, phase contrast edge enhancement was observed in a phase object placed in the beam path. This amorphous selenium/CMOS detector technology can address gaps in commercially available X-ray detectors which limit their usefulness for existing synchrotron applications at energies greater than 50 keV; for example, phase contrast tomography and high-resolution imaging of nanoscale lattice distortions in bulk crystalline materials using Bragg coherent diffraction imaging. Here, the technology will also facilitate the creation of novel synchrotron imaging applications for X-ray energies at or above 20 keV.

36 MATERIALS SCIENCE↗

Charged particle track reconstruction with SπRIT Time Projection Chamber

In this work, we present a software framework, SπRITROOT, which is capable of track reconstruction and analysis of heavy-ion collision events recorded with the SRIT time projection chamber. The track-fitting toolkit GENFIT and the vertex reconstruction toolkit RAVE are applied to a box-type detector system. A pattern recognition algorithm which performs helix track finding and handles overlapping pulses is described. The performance of the software is investigated using experimental data obtained at the Radioactive Isotope Beam Facility (RIBF) at RIKEN. This work focuses on data from 132 Sn + 124 Sn collision events with beam energy of 270 AMeV. Particle identification is established using < dE/dx >and magnetic rigidity, with pions, hydrogen isotopes, and helium isotopes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation hardness characterization of LKH-5 scintillating glass

Radiation hardness is an important property to examine in scintillators to help determine their expected lifetime in application cases where significant radiation dose is expected. Industrial imaging systems using 9 MV linear accelerators for x-ray radiography are one such application where significant radiation doses are expected to the scintillators used. Cadmium tungstate scintillators (CWO) and Thallium doped Cesium Iodide scintillators (CsI(Tl)) are used in some high energy cargo x-ray radiography systems. However, CWO has a high manufacturing cost for adequately uniform crystals and CsI(Tl) does not have sufficient radiation hardness. LKH-5 glass is being investigated as a potential low cost replacement for CWO and CsI(Tl). In this experiment 36 samples of a terbium doped silicate glass called LKH-5 were irradiated at doses up to 5 MRad using a 9 MV linear accelerator, and the change in their transmission properties was observed. Additionally, the glass was discovered to be a radiation hard glass due to the relatively small change in the transmission of the glass: less than 3% per cm at its emission peak of 550 nm and 5 MRad. This is similar to CWO which has a reported reduction in transmitted light of 2% per cm at 5 MRad and the emission peak of 475 nm and better than CsI(Tl) which is reported to have a reduction in transmitted light of 5% per cm at the emission peak of 550 nm and 4.2 MRad dose. Furthermore, an annealing procedure is described that returned the transmission of the glass to pre-irradiation values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulation studies for beam commissioning at FRIB Advanced Rare Isotope Separator

The Facility for Rare Isotope Beams (FRIB) includes a powerful superconducting driver accelerator and an Advanced Rare Isotope Separator (ARIS). The ARIS collects and purifies the rare isotope fragments of interest for experiments in nuclear physics, nuclear astrophysics, fundamental symmetries, etc. ARIS consists of a vertical pre-separator and downstream horizontal separator section (C-Bend). Each section can provide a high-resolution separation alternatively. The resolution reduction due to the emittance induced by momentum compression can be avoided by isotope separation in different dispersive planes. Beam commissioning of ARIS for the first experiments was completed and demonstrated particle identification of fragments. The beam tuning in ARIS largely relies on numerical simulations since the limited space for diagnostics. Here, we report the result of the beam trajectory correction, transverse matching, and beam-based misalignment studies at ARIS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CsI(Tl) pulse shape discrimination with the Belle II electromagnetic calorimeter as a novel method to improve particle identification at electron–positron colliders

Here we describe the implementation and performance of CsI(Tl) pulse shape discrimination for the Belle II electromagnetic calorimeter, representing the first application of CsI(Tl) pulse shape discrimination for particle identification at an electron–positron collider. The pulse shape characterization algorithms applied by the Belle II calorimeter are described. Control samples of $γ, μ^+, π^±, K^±$ and $ρ/ \bar{ρ}$ are used to demonstrate the significant insight into the secondary particle composition of calorimeter clusters that is provided by CsI(Tl) pulse shape discrimination. Comparisons with simulation are presented and provide further validation for newly developed CsI(Tl) scintillation response simulation techniques, which when incorporated with GEANT4 simulations allow the particle dependent scintillation response of CsI(Tl) to be modelled. Comparisons between data and simulation also demonstrate that pulse shape discrimination can be a new tool to identify sources of improvement in the simulation of hadronic interactions in materials. The $K^0_L$ efficiency and photon-as-hadron fake-rate of a multivariate classifier that is trained to use pulse shape discrimination is presented and comparisons are made to a shower-shape based approach. CsI(Tl) pulse shape discrimination is shown to reduce the photon-as-hadron fake-rate by over a factor of 3 at photon energies of 0.2 GeV and over a factor 10 at photon energies of 1 GeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

BoxScore - A real-time beam-diagnosis program for the CAEN digitizer x730 series

BoxScore is a real-time beam diagnosis and monitoring program for the CAEN x730 series digitizer, developed for the ATLAS in-flight system at Argonne National Laboratory. The CAEN x730 series digitizer, with built-in Digital Pulse Processing for the Pulse-Height-Analysis, digitizes the input signal in real-time and processes it using a trapezoidal filter. BoxScore reads the digitizer’s buffer directly, builds and saves events to local files, plots histograms for particle identification, and outputs the rates of selected isotopes every second. Implementation of BoxScore has shortened the time needed for in-flight beam-tuning and has potential applications for other nuclear physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of nuclear reactor radiation on the performance of AlN/sapphire surface acoustic wave devices

The performance of an AlN/sapphire surface acoustic wave (SAW) delay line device was characterized in real time under irradiation inside a nuclear reactor. Both its resonant frequency and transmission efficiency were observed to respond to a change in reactor power. The response follows an exponentially saturating behavior after a step power increase, followed by an exponentially decaying recovery after reactor shutdown. A sensitivity analysis based on the governing electro-mechanical equations shows that the frequency shift can be attributed to the softening of sapphire’s elastic constants under neutron radiation. Additionally, a kinetic rate equation is adopted to interpret device response and describe its microstructural evolution. These results suggest that the AlN/sapphire SAW device remains functional under irradiation, is sensitive to neutron and gamma ray fluxes, and offers an opportunity for remote sensing and in-situ measurement of material properties when exposed to nuclear reactor environment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of a rapid-transit system for precision nuclear physics measurements

A Rapid Belt-driven Irradiated Target Transfer System, named RABITTS, was developed for use at the Triangle Universities Nuclear Laboratory. This system allows for cyclic activation with neutron or photon beams, and measurement of reaction products using γ-ray spectroscopy. Both a 1 meter and 10 meter transfer system have been developed with transit times as low as 0.4 and 1.0 seconds, respectively. The systems are deployed at the tandem accelerator laboratory for use with monoenergetic neutron beams, and at the High-Intensity γ-ray Source facility for activation using photon beams. A detailed characterization of the systems’ performance and sensitivity is presented. In order to produce the highest accuracy cross-section data, a model for calculating corrections to cyclic activation with variable beam flux is developed and presented. We have commissioned these systems by measuring 197m Au, where we report a measured half-life of 7.73 ± 0.05 s and a 197 Au(n, n') 197m Au isomer production cross of 628 ± 28 mb at neutron energy E n = 2.0 MeV. In addition, we measured 90m Zr, where we report a measured half-life of 799.7 ± 8.0 ms and a 90 Zr(n, n') 90m Zr isomer production cross of 180 ± 12 mb at E n = 4.6 MeV. Furthermore, these measured half-lives are in excellent agreement with the evaluated values and the cross-section measurements are performed at previously unmeasured incident neutron energies.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗