Search NASA⌕ Search

SEARCH · Search NASA

Results for “OMEGA FACILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The Sixth Omega Laser Facility Users Group Workshop

A capacity gathering of over 100 researchers from 25 universities and laboratories met at the Laboratory for Laser Energetics (LLE) for the Sixth Omega Laser Facility Users Group (OLUG) workshop. The purpose of the 2.5-day workshop was to facilitate communications and exchanges among individual OMEGA users, and between users and the LLE management; to present ongoing and proposed research; to encourage research opportunities and collaborations that could be undertaken at the Omega Laser Facility and in a complementary fashion at other facilities [such as the National Ignition Facility (NIF) or the Laboratoire pour l’Utilisation des Lasers Intenses (LULI)]; to provide an opportunity for students, postdoctoral fellows, and young researchers to present their research in an informal setting; and to provide feedback from the users to LLE management about ways to improve and keep the facility and future experimental campaigns at the cutting edge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new neutron time-of-flight detector for yield and ion-temperature measurements at the OMEGA Laser Facility

A new neutron time-of-flight (nTOF) detector for deuterium–deuterium (DD)-fusion yield and ion-temperature measurements was designed, installed, and calibrated for the OMEGA Laser Facility. This detector provides an additional line of sight for DD neutron yield and ion-temperature measurements for yields exceeding 1 × 10 10 with higher precision than existing detectors. The nTOF detector consists of a 90-mm-diam, 20-mm-thick BC-422 scintillator and a gated Photek photomultiplier tube (PMT240). The PMT collects scintillating light through the 20-mm side of the scintillator without the use of a light guide. There is no lead shielding from hard x rays in order to allow the x-ray instrument response function of the detector to be measured easily. Instead, hard x-ray signals generated in implosion experiments are gated out by the PMT. The design provides a place for glass neutral-density filters between the scintillator and the PMT to avoid PMT saturation at high yields. The nTOF detector is installed in the OMEGA Target Bay along the P8A sub-port line of sight at a distance of 5.3 m from the target chamber center. In addition to DD measurements, the same detector can be used to measure the neutron yield and ion temperature from deuterium–tritium (DT) implosion targets in the 5 × 10 10 to 2 × 10 12 yield range. Here, the design details and the calibration results of this nTOF detector for both D 2 and DT implosions on OMEGA will be presented.

47 OTHER INSTRUMENTATION↗

Nuclear activation analysis of zirconium-90 isomeric and ground-state reactions at the OMEGA Laser Facility

Nuclear activation is a well-established technique for inferring neutron yields in laser direct-drive deuterium–tritium (DT) and deuterium–deuterium (D 2 ) implosions at the OMEGA Laser Facility. Zirconium has long been considered an excellent candidate for measuring DT neutron fusion yields by observing decays of the 90 Zr(n,2n) 89 Zr ground-state reaction. As it has a higher energy threshold than present activation detectors utilizing copper, zirconium provides a means to infer primary neutron yields that are less susceptible to being skewed due to neutron scattering within the experimental environment. However, with a 78.41-h half-life, it is not operationally practical to utilize this reaction for OMEGA experiments, which have a 1-h shot cycle. Zirconium’s 90 Zr(n,2n) 89 mZr reaction presents itself as a viable candidate to infer neutron yields within a shot cycle, given its half-life of 4.16 min. Here, we present an overview of the approach and methodology, utilizing first principles techniques, to infer the primary neutron yields from OMEGA DT fusion experiments by using both the isomeric and the ground-state reaction. Yields inferred from both reactions are compared, which are in good agreement between the two.

Activation analysis↗

Hohlraum-Driven Mid-Z (SiO{sub 2}) Double-Shell Implosions on the Omega Laser Facility and Their Scaling to NIF

High-convergence, hohlraum-driven implosions of double-shell capsules using mid-Z (SiO{sub 2}) inner shells have been performed on the OMEGA laser facility [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)]. These experiments provide an essential extension of the results of previous low-Z (CH) double-shell implosions [P. A. Amendt et al., Phys. Rev. Lett. 94, 065004 (2005)] to materials of higher density and atomic number. Analytic modeling, supported by highly resolved 2D numerical simulations, is used to account for the yield degradation due to interfacial atomic mixing. This extended experimental database from OMEGA enables a validation of the mix model, and provides a means for quantitatively assessing the prospects for high-Z double-shell implosions on the National Ignition Facility [Paisner et al., Laser Focus World 30, 75 (1994)].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In situ calibration of charged particle spectrometers on the OMEGA Laser Facility using 241 Am and 226 Ra sources

Charged particle spectrometry is a critical diagnostic to study inertial-confinement-fusion plasmas and high energy density plasmas. The OMEGA Laser Facility has two fixed magnetic charged particle spectrometers (CPSs) to measure MeV-ions. In situ calibration of these spectrometers was carried out using 241 Am and 226 Ra alpha emitters. The alpha emission spectrum from the sources was measured independently using surface-barrier detectors (SBDs). The energy dispersion and broadening of the CPS systems were determined by comparing the CPS measured alpha spectrum to that of the SBD. The calibration method significantly constrains the energy dispersion, which was previously obtained through the measurement of charged particle fusion products. Overall, a small shift of 100 keV was observed between previous and the calibration done in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of a Faraday rotation diagnostic at the OMEGA laser facility

Magnetic field measurements in turbulent plasmas are often difficult to perform. Here we show that for ${\geqslant}$ kG magnetic fields, a time-resolved Faraday rotation measurement can be made at the OMEGA laser facility. This diagnostic has been implemented using the Thomson scattering probe beam and the resultant path-integrated magnetic field has been compared with that of proton radiography. As a result, accurate measurement of magnetic fields is essential for satisfying the scientific goals of many current laser–plasma experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using millimeter-sized carbon–deuterium foils for high-precision deuterium–tritium neutron spectrum measurements in direct-drive inertial confinement fusion at the OMEGA laser facility

Millimeter-sized CD foils fielded close (order mm) to inertial confinement fusion (ICF) implosions have been proposed as a game-changer for improving energy resolution and allowing time-resolution in neutron spectrum measurements using the magnetic recoil technique. This paper presents results from initial experiments testing this concept for direct drive ICF at the OMEGA Laser Facility. Additionally, while the foils are shown to produce reasonable signals, inferred spectral broadening is seen to be high (~5 keV) and signal levels are low (by ~20%) compared to expectation. Before this type of foil is used for precision experiments, the foil mount must be improved, oxygen uptake in the foils must be better characterized, and impact of uncontrolled foil motion prior to detection must be investigated.

47 OTHER INSTRUMENTATION↗

Using millimeter-sized carbon-deuterium foils for high-precision deuterium-tritium neutron spectrum measurements in direct-drive inertial confinement fusion at the OMEGA laser facility

Millimeter-sized CD foils fielded close (order mm) to inertial confinement fusion (ICF) implosions have been proposed as a game-changer for improving energy resolution and allowing time-resolution in neutron spectrum measurements using the magnetic recoil technique. This paper presents results from initial experiments testing this concept for direct drive ICF at the OMEGA laser facility. While the foils are shown to produce reasonable signals, inferred spectral broadening is seen to be high (~5 keV) and signal levels low (by ~20%) compared to expectation. Before this type of foil is used for precision experiments, the foil mount must be improved, oxygen uptake in the foils better characterized, and impact of uncontrolled foil motion prior to detection investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a compact magnetic spectrometer for use at the OMEGA Laser Facility and the National Ignition Facility

Measurement of proton spectra is an important diagnostic for a variety of high energy density physics experiments. Current diagnostics are either not designed to capture the spectrum of low-energy protons or are unsuitable for high debris experiments. To bridge the gap, a new CR-39 based compact magnetic spectrometer (MagSpec) has been developed to measure proton spectra in the 1–20 MeV energy range, with a particular focus on the low-energy (1–6 MeV) spectrum, for use in experiments at the OMEGA Laser Facility and the National Ignition Facility (NIF). In the MagSpec diagnostic, protons of different energies are dispersed as they pass through a magnetic field before impinging on a differentially filtered CR-39 surface, resulting in a spatial distribution of CR-39 tracks that corresponds to the energy spectrum. In this paper, we discuss details of the design and implementation of MagSpec on the NIF and OMEGA.

47 OTHER INSTRUMENTATION↗

Deep learning-based predictive models for laser direct drive at the Omega Laser Facility

The rich and complex physics of inertial confinement fusion provides a unique and challenging space for high-fidelity first-principles modeling. Consequently, simulation codes that are used to design experiments are computationally expensive and lack the predictive capability required for extensive parameter exploration in search of a high-performing design for laser direct drive. In this article, we present two deep-learning-based predictive models intended to address these difficulties. The first model (TL DNN) acts as a fast emulator of simulations as well as experiments at the Omega Laser Facility. This model is trained on a simulation database and subsequently calibrated on experimental data using transfer learning. To facilitate the development of this model, an autoencoder is developed to reduce the dimensionality of the input space by compressing the laser pulse input. The model predicts key experimental scalar observables of Omega experiments with high accuracy and minimal computational cost. This deep neural net enables rapid exploration of a high-dimensional input parameter space for an optimal implosion design. The second model (DNN SM+) aims to extend the statistical modeling work of Lees et al. [Phys. Rev. Lett. 127, 105001 (2021)], by increasing the complexity of the model space and allowing for coupling between degradation terms. Since the model capacity of DNN SM+ is higher than the model of Lees et al., DNN SM+ can potentially provide an improvement in predictive capability, and we use this model to provide insight into complicated degradation dependencies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Foil backlighter development at the OMEGA laser facility for extended x-ray absorption fine structure experiments

Extended x-ray absorption fine structure (EXAFS) measurements require a bright and continuous x-ray source and a detection system with high spectral resolution to capture the modulations of the absorption coefficient above the material absorption edge. When performing EXAFS measurements under laser-driven dynamic compression, it is hence critical to optimize the backlighter x-ray emission. In this study, a series of experiments has been conducted at the OMEGA laser facility to characterize titanium (Z = 22), iron (Z = 26), germanium (Z = 32), molybdenum (Z = 42), silver (Z = 47), and gold (Z = 79) foil backlighters irradiated with 3 kJ–12 kJ of laser energy. The spectra have been recorded using a dual crystal spectrometer (DCS), a two-channel transmission spectrometer covering 11 keV–45 keV and 19 keV–90 keV energy bands. The DCS has been calibrated so that the spectral intensities can be compared between different campaigns.

47 OTHER INSTRUMENTATION↗

Summaries of FY12 LANL Experimental Campaigns at the OMEGA Laser Facility

In FY 2012, Los Alamos National Laboratory (LANL) executed 244 total shots on OMEGA. LANL experiments contributed to the National Ignition (NIC) campaign in the following ways: • Measured the x-ray ablative Richtmyer-Meshkov growth of isolated defects on plastic ablators, • Studied branching ratios in DT fusion plasmas, and • Continued neutron imaging and radchem scintillator development for NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three-dimensional reconstruction of laser-direct-drive inertial confinement fusion hot-spot plasma from x-ray diagnostics on the OMEGA laser facility (invited)

A deep-learning convolutional neural network (CNN) is used to infer, from x-ray images along multiple lines of sight, the low-mode shape of the hot-spot emission of deuterium–tritium (DT) laser-direct-drive cryogenic implosions on OMEGA. The motivation of this approach is to develop a physics-informed 3-D reconstruction technique that can be performed within minutes to facilitate the use of the results to inform changes to the initial target and laser conditions for the subsequent implosion. The CNN is trained on a 3D radiation-hydrodynamic simulation database to relate 2D x-ray images to 3D emissivity at stagnation. The CNN accounts for the lack of an absolute spatial reference and the different bands of photon energies in the x-ray images. While previous works studied the effect of mode-1 asymmetries on implosion performance using nuclear diagnostics, this work focuses on the effect of mode 2 inferred from x-ray diagnostics on implosion performance. A current analysis of 19 DT cryogenic implosions indicates there is an upper limit of ~20% reduction in the neutron yield caused by an ℓ = 2 amplitude for ℓ 2 /ℓ 0 ≤ 0.32. Here, these conclusions are supported by 2D simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase imaging of irradiated foils at the OMEGA EP facility using phase-stepping X-ray Talbot–Lau deflectometry

Abstract Diagnosing the evolution of laser-generated high energy density (HED) systems is fundamental to develop a correct understanding of the behavior of matter under extreme conditions. Talbot–Lau interferometry constitutes a promising tool, since it permits simultaneous single-shot X-ray radiography and phase-contrast imaging of dense plasmas. We present the results of an experiment at OMEGA EP that aims to probe the ablation front of a laser-irradiated foil using a Talbot–Lau X-ray interferometer. A polystyrene (CH) foil was irradiated by a laser of 133 J, 1 ns and probed with 8 keV laser-produced backlighter radiation from Cu foils driven by a short-pulse laser (153 J, 11 ps). The ablation front interferograms were processed in combination with a set of reference images obtained ex situ using phase-stepping. We managed to obtain attenuation and phase-shift images of a laser-irradiated foil for electron densities above ${10}^{22}\;{\mathrm{cm}}^{-3}$ . These results showcase the capabilities of Talbot–Lau X-ray diagnostic methods to diagnose HED laser-generated plasmas through high-resolution imaging.

47 OTHER INSTRUMENTATION↗

Monte Carlo validation experiments for the gas Cherenkov detectors at the National Ignition Facility and Omega

The gas Cherenkov detectors at NIF and Omega measure several ICF burn characteristics by detecting multi-MeV nuclear γ emissions from the implosion. Of primary interest are γ bang-time (GBT) and burn width defined as the time between initial laser-plasma interaction and peak in the fusion reaction history and the FWHM of the reaction history respectively. To accurately calculate such parameters the collaboration relies on Monte Carlo codes, such as GEANT4 and ACCEPT, for diagnostic properties that cannot be measured directly. This paper describes a series of experiments performed at the High Intensity γ Source (HIγS) facility at Duke University to validate the geometries and material data used in the Monte Carlo simulations. Results published here show that model-driven parameters such as intensity and temporal response can be used with less than 50% uncertainty for all diagnostics and facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimized x-ray sources for x-ray diffraction measurements at the Omega Laser Facility

The use of x-ray diffraction (XRD) measurements in laser-driven dynamic compression experiments at high-power laser facilities is becoming increasingly common. Diffraction allows one to probe in situ the transformations occurring at the atomic level at extreme conditions of pressure, temperature, and time scale. In these measurements, the x-ray source is generated by irradiation of a solid foil. Under certain laser drive conditions, quasimonochromatic He-α radiation is generated. Careful analysis of the x-ray source plasma spectra reveals that this radiation is not a single line emission and that monochromaticity is highly dependent on the laser irradiance. In this work, we analyze how the spectra emitted by laser-irradiated copper, germanium, and iron foils at the Omega Laser vary depending on different laser drive conditions and discuss the implications for XRD experiments.

47 OTHER INSTRUMENTATION↗