Search NASA⌕ Search

SEARCH · Search NASA

Results for “OPERATIONAL PROBLEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Variational stability of optimal control problems involving subdifferential operators

This paper is concerned with the problem of minimizing an integral functional with control-nonconvex integrand over the class of solutions of a control system in a Hilbert space subject to a control constraint given by a phase-dependent multivalued map with closed nonconvex values. The integrand, the subdifferential operators, the perturbation term, the initial conditions and the control constraint all depend on a parameter. Along with this problem, the paper considers the problem of minimizing an integral functional with control-convexified integrand over the class of solutions of the original system, but now subject to a convexified control constraint. By a solution of a control system we mean a 'trajectory-control' pair. For each value of the parameter, the convexified problem is shown to have a solution, which is the limit of a minimizing sequence of the original problem, and the minimal value of the functional with the convexified integrand is a continuous function of the parameter. This property is commonly referred to as the variational stability of a minimization problem. An example of a control parabolic system with hysteresis and diffusion effects is considered. Bibliography: 24 titles.

97 MATHEMATICS AND COMPUTING↗

Army Re-tuning™ Implementation Guides

The Army is a large, geographically dispersed organization with 156 installations and over 980 million square feet of building space to operate and maintain. The building stock spans a wide range of vintages and missions, with many serving cross-cutting functions and purposes. To meet Federal mandates and reduction goals organizationally, in recent years the Army has aggressively pursued policy and energy efficiency projects and programs resulting in a 9.6% reduction in energy use intensity (EUI) from fiscal year (FY) 2015 to FY2017. Despite these successes, the Army remains the largest consumer of electricity in the Federal government and spent approximately $1.1 billion in energy-related costs in FY2017 The Pacific Northwest National Laboratory (PNNL), in support of the Assistant Secretary of the Army (Installations, Energy and Environment) (ASA (IE&E)), was tasked with a multi-year study and pilot demonstration to develop a business case for the potential energy and cost reduction benefits from re-tuning™ efforts for the Army. Re tuning is a systematic process aimed at minimizing building energy consumption by identifying and correcting operational problems that plague buildings. The methodology was developed by PNNL research staff in an effort to improve building operational efficiency at no- or low-cost, primarily through building automation system (BAS) controls. The methodology is based on two basic principles: If the equipment is not needed, turn it off; and if the equipment is not needed at full power, turn it down. Implementation of identified low-cost/no-cost operational improvements through the re-tuning process results in increased building energy efficiency, reduced operating costs, and improvement to occupant comfort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Summary of DM1200 WESP History and Performance

The principal objective of this report was to summarize the testing experience on the DM1200 WESP. Further objectives were to provide descriptions of the history of all modifications and maintenance, methods of operation, problems and unit failures, and performance while processing a variety of feeds, and while employing a variety of operating methods, and to provide comparisons to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) high level waste (HLW) and low activity waste (LAW) WESP designs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Summary of DM1200 SBS history and performance

The principal objective of this report is to summarize the testing experience on the DM1200 SBS. Further objectives are to provide descriptions of the history of all modifications and maintenance, methods of operation, problems and unit failures, and performance while processing a variety of feeds, and while employing a variety of operating methods, and to provide comparisons to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) High Level Waste (HLW) and Low Activity Waste (LAW) Submerged Bed Scrubber (SBS) designs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NATURAL GAS VARIABILITY IN CALIFORNIA: ENVIRONMENTAL IMPACTS AND DEVICE PERFORMANCE EXPERIMENTAL EVALUATION OF POLLUTANT EMISSIONS FROM RESIDENTIAL APPLIANCES

The effect of liquefied natural gas on pollutant emissions was evaluated experimentally with used and new appliances in the laboratory and with appliances installed in residences, targeting information gaps from previous studies. Burner selection targeted available technologies that are projected to comprise the majority of installed appliances over the next decade. Experiments were conducted on 13 cooktop sets, 12 ovens, 5 broiler burners, 5 storage water heaters, 4 forced air furnaces, 1 wall furnace, and 6 tankless water heaters. Air-free concentrations and fuel-based emission factors were determined for carbon monoxide, nitrogen oxides, nitrogen dioxide, and the number of (predominantly ultrafine) particles over complete burns?including transient effects (device warm-up and intermittent firing of burners) following ignition--and during more stable end-of-burn conditions. Formaldehyde was measured over multi-burn cycles. The baseline fuel was Northern California line gas with Wobbe number (a measure of fuel energy delivery rate) of 1320-1340; test fuels had Wobbe numbers of roughly 1390 and 1420, and in some cases 1360. No ignition or operational problems were observed during test fuel use. Baseline emissions varied widely across and within burner groups and with burner operational mode. Statistically significant emissions changes were observed for some pollutants on some burners.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Conservation of Helium while Maintaining High System Purity

Recent helium shortages and helium price increases have lead to an increased emphasis being placed on conserving helium. The need to conserve helium must be balanced with need to maintain the high levels of purity necessary to prevent operational problems caused by contamination. Helium losses and contamination control are especially important for test stands that have cryogenic distribution systems operating continuously with frequent changeover of cryogenic temperature components that are being tested. This paper describes a mathematical model to estimate the quantity of helium lost and the purity of the helium after the pump and backfill procedure is complete. The process to determine the optimal time during pump down to cut off pumping and start backfilling is described. There is a tradeoff between trying to achieve the lowest possible pressure during pumping and the quantity of air leaking into the volume while pumping is occurring. An additional benefit of careful sel ection of pump and backfill parameters in conjunction with real-time pressure monitoring can reduce the labor and time required to complete a successful pump and backfill procedure. This paper is intended to be a tool for engineers to review their pump and backfill procedures and measured data to optimize helium losses, system purity, and labor required.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Conservation of Helium while Maintaining High System Purity

Recent helium shortages and helium price increases have lead to an increased emphasis being placed on conserving helium. The need to conserve helium must be balanced with need to maintain the high levels of purity necessary to prevent operational problems caused by contamination. Helium losses and contamination control are especially important for test stands that have cryogenic distribution systems operating continuously with frequent changeover of cryogenic temperature components that are being tested. This paper describes a mathematical model to estimate the quantity of helium lost and the purity of the helium after the pump and backfill procedure is complete. The process to determine the optimal time during pump down to cut off pumping and start backfilling is described. There is a tradeoff between trying to achieve the lowest possible pressure during pumping and the quantity of air leaking into the volume while pumping is occurring. An additional benefit of careful selection of pump and backfill parameters in conjunction with real-time pressure monitoring can reduce the labor and time required to complete a successful pump and backfill procedure. This paper is intended to be a tool for engineers to review their pump and backfill procedures and measured data to optimize helium losses, system purity, and labor required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimal Heliostat Assignment Strategy for Multiple-Receiver Systems

Next-generation concentrating solar power concepts currently being developed under the U.S. Department of Energy's Gen3 program include several novel heliostat field and receiver arrangements. Among these concepts are solar fields utilizing multiple receivers or several distinct receiver flux control zones, and each of which has particular power or peak flux constraints. In this paper, we present a linear program that identifies optimal heliostat-to-receiver assignment strategies for multi-receiver or multi-zone solar fields based on detailed calculations made by an optics modeling package. Two distinct problems are addressed: namely, (1) a design problem that chooses the optimal set of heliostats to include in a final layout given receiver constraints and performance, and (2) an operations problem that assigns existing heliostats to a receiver, maximizing field power output while maintaining receiver power constraints. The optimization methodology is integrated into the concentrating solar power tower modeling package SolarPILOTTM, and results are presented showing that heliostat assignment strategies can impact both initial heliostat field layout characteristics and the cost of thermal energy produced by the field. The methodology succeeds in maintaining power requirements but at the expense of producing different flux profiles on each receiver surface. Consequently, the paper also discusses additional measures that are applied to ensure that desirable flux distribution properties are maintained, reducing local flux mean-absolute-deviation values from a baseline of 17% or greater to less than 5% compared to a desired reference flux profile.

41 EE - Solar Energy Technologies Office (EE-4S)↗

State-of-the-art short-term electricity market operation with solar generation: A review

With the accelerating penetration of solar energy in energy systems, market operations concerning the solar-associated intermittency are widely discussed. How to correctly model the solar generation in the market and solve the uncertainty-based operation problems call for solutions. Unlike other renewable resources, solar power can be more easily applied to the demand side through behind-the-meter installations in a distributed manner with significant future extensibility. The corresponding operational rules in the markets are largely being revised. Over the past two decades, with the development of deregulated power markets, numerous studies related to uncertainty-based market operations tend to transform the market from a deterministic and centralized framework to a stochastic and decentralized one. As the relevant literature is most recent, this paper reviews their contributions to electricity market operations with solar integration and underlines the research directions of this topic and ongoing industry practices. A thorough review of the electricity markets worldwide with solar energy is provided. A variety of proposed mathematical solutions to the problem are also addressed.

14 SOLAR ENERGY↗

Relaxations of the steady optimal gas flow problem for a non-Ideal gas

Natural gas ranks second in U.S. primary energy consumption. Because most production sites are remote, gas must be transported through pipeline networks equipped with compressors, valves, and other components. For both economic efficiency and system reliability, it is desirable to operate these networks optimally. The governing physics across pipeline components entails nonlinear, non-convex equality and inequality constraints, and the most general steady-flow operations problem is a Mixed-Integer Nonlinear Program (MINLP).This work focuses on one such steady-flow problem-the Optimal Gas Flow (OGF) for a natural gas pipeline network-which minimizes production cost subject to the steady-flow physics. For day-to-day operations, the ability to quickly compute a globally optimal solution and a strong lower bound for varying demand profiles is crucial. A promising strategy is to build tight relaxations of the OGF’s nonlinear constraints. However, many nonlinearities arising from non-ideal equations of state either lack relaxations or have relaxations that do not scale to realistic network sizes. We address this gap by combining recent advances in polyhedral relaxations for univariate functions to construct tight, computationally efficient relaxations of the OGF with a non-ideal equation of state. These relaxations solve within seconds on a standard laptop. In conclusion, we demonstrate their quality through extensive numerical experiments on very large-scale test networks from the literature and find that the proposed approach proves optimality in 92% of tested instances.

03 NATURAL GAS↗

Improved liquid lithium surfaces in the Lithium Tokamak Experiment-β

Advances in vacuum, surface, and lithium conditioning techniques throughout five years of continuous operations in LTX-β have produced mirror-like liquid lithium surfaces and demonstrated the feasibility of high-performance tokamak discharges fully surrounded by liquid metal without significant operational problems. Improvements in conditioning techniques and procedures, including many weeks of baking and accumulation of 70 g of Li, led to reduced residual gasses and clean Li surfaces - all while still maintaining enough operational flexibility for multiple in-vacuum diagnostic upgrades and calibrations. Coatings had a visibly clean appearance, with reflective liquid metal demonstrating good wetting and surface adhesion with films that were now macroscopically thick. Solidified Li showed large crystal grains, while surface science measurements observed reduced impurities in the lithium. Steadily improved plasma performance was achieved with liquid lithium, with discharges able to match solid Li in terms of evolution of I p and n e , including rapid density pumping indicating low recycling. There were indications of moderately increased Li impurity influx, though few significant disturbances by the large liquid surfaces on tokamak operations over hundreds of discharges. Liquid metal plasma facing components are a potential solution to the extreme heat and particle fluxes that could cause unacceptable damage to solid materials, while liquid lithium also has the potential for greatly increased confinement in the low-recycling regime. While many liquid metal approaches are possible, and numerous experiments have been conducted in test stands and small modules in fusion devices, LTX-β is the only tokamak operated while fully surrounded by liquid metal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EFFLUENT TREATMENT FACILITY PEROXIDE DESTRUCTION CATALYST TESTING

The 200 Area Effluent Treatment Facility (ETF) main treatment train includes the peroxide destruction module (PDM) where the hydrogen peroxide residual from the upstream ultraviolet light/hydrogen peroxide oxidation unit is destroyed. Removal of the residual peroxide is necessary to protect downstream membranes from the strong oxidizer. The main component of the PDM is two reaction vessels utilizing granular activated carbon (GAC) as the reaction media. The PDM experienced a number of operability problems, including frequent plugging, and has not been utilized since the ETF changed to groundwater as the predominant feed. The unit seemed to be underperforming in regards to peroxide removal during the early periods of operation as well. It is anticipated that a functional PDM will be required for wastewater from the vitrification plant and other future streams. An alternate media or methodology needs to be identified to replace the GAC in the PDMs. This series of bench scale tests is to develop information to support an engineering study on the options for replacement of the existing GAC method for peroxide destruction at the ETF. A number of different catalysts will be compared as well as other potential methods such as strong reducing agents. The testing should lead to general conclusions on the viability of different catalysts and identify candidates for further study and evaluation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Final Report Summary of DM1200 Operation at VSL

The principal objective of this report was to summarize the testing experience on the DuraMelter 1200 (DMI200), which is the High Level Waste (HLW) Pilot Melter located at the Vitreous State Laboratory (VSL). Further objectives were to provide descriptions of the history of all modifications and maintenance, methods of operation, problems and unit failures, and melter emissions and performance while processing a variety of simulated HL W and low activity waste (LAW) feeds for the Hanford Waste Treatment and Immobilization Plant (WTP) and employing a variety of operating methods. All of these objectives were met. The River Protection Project - Hanford Waste Treatment and Immobilization Plant (RPP-WTP) Project has undertaken a 'tiered' approach to vitrification development testing involving computer-based glass formulation, glass property-composition models, crucible melts, and continuous melter tests of increasing, more realistic scales. Melter systems ranging from 0.02 to 1.2 m{sup 2} installed at the Vitreous State Laboratory (VSL) have been used for this purpose, which, in combination with the 3.3 m{sup 2} low activity waste (LAW) Pilot Melter at Duratek, Inc., span more than two orders of magnitude in melt surface area. In this way, less-costly small-scale tests can be used to define the most appropriate tests to be conducted at the larger scales in order to extract maximum benefit from the large-scale tests. For high level waste (HLW) vitrification development, a key component in this approach is the one-third scale DuraMelter 1200 (DM 1200), which is the HLW Pilot Melter that has been installed at VSL with an integrated prototypical off-gas treatment system. That system replaced the DM1000 system that was used for HLW throughput testing during Part B1. Both melters have similar melt surface areas (1.2 m{sup 2}) but the DM1200 is prototypical of the present RPP-WTP HLW melter design whereas the DM1000 was not. In particular, the DM1200 provides for testing on a vitrification system with the specific train of unit operations that has been selected for both HLW and LAW RPP-WTP off-gas treatment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Anaerobic co-digestion of aquatic flora and quinoa with manures from Bolivian Altiplano

Quinoa stalk (Chenopodium quinoa Willd.) from agricultural crop residue, totora (Schoenoplectus tatora) and o-macrophytes (aquatic flora) from Lake Titicaca (on the Bolivian Altiplano) were studied in a wet anaerobic co-digestion process together with manure from llama, cow and sheep. Anaerobic semi-continuous experiments were performed in (10) 2-l reactors at a temperature of 25 deg. C with 30 days of hydraulic retention time (HRT) and an organic loading rate (OLR) of 1.8 kg VS m{sup -3} d{sup -1}. Totora was found to be the best co-substrate. In mixture ratios of 1:1 (VS basis), it increased the biogas productivity by 130% for llama manure, 60% for cow manure, and 40% for sheep manure. It was possible to use up to 58% (VS basis) of totora in the substrate. Higher concentrations (including pure totora) could not be digested, as that caused acidification problems similar to those caused by other lignocellulosic materials. When quinoa and o-macrophytes were used as co-substrates, the increase in biogas productivity was slightly less. However, these co-substrates did not cause any operational problems. An additional advantage of quinoa and o-macrophytes was that they could be used in any proportion (even in pure form) without causing any destabilization problems in the anaerobic digestion process.

54 ENVIRONMENTAL SCIENCES↗

Switching Device-Cognizant Sequential Distribution System Restoration

This paper presents an optimization framework for sequential reconfiguration using an assortment of switching devices and repair process in distribution system restoration. Compared to existing studies, this paper considers types, capabilities and operational limits of different switching devices, making it applicable in practice. We develop a novel multi-phase method to find the optimal sequential operation of various switching devices and repair faulted areas. We consider circuit breakers, reclosers, sectionalizers, load breaker switches, and fuses. The switching operation problem is decomposed into two mixed-integer linear programming (MILP) subproblems. The first subproblem determines the optimal network topology and estimates the number of steps to reach that topology, while the second subproblem generates a sequence of switching operations to coordinate the switches. For repairing the faults, we design an MILP model that dispatches repair crews to clear faults and replace melted fuses. After clearing a fault, we update the topology of the network by generating a new sequence of switching operations, and the process continues until all faults are cleared. To improve the computational efficiency, a network reduction algorithm is developed to group line sections, such that only switchable sections are present in the reduced network. The proposed method is validated on the IEEE 123-bus and 8500-bus systems.

distribution system↗

REMOVAL OF SOLIDS FROM HIGHLY ENRICHED URANIUM SOLUTIONS USING THE H-CANYON CENTRIFUGE

Prior to the dissolution of Pu-containing materials in HB-Line, highly enriched uranium (HEU) solutions stored in Tanks 11.1 and 12.2 of H-Canyon must be transferred to provide storage space. The proposed plan is to centrifuge the solutions to remove solids which may present downstream criticality concerns or cause operational problems with the 1st Cycle solvent extraction due to the formation of stable emulsions. An evaluation of the efficiency of the H-Canyon centrifuge concluded that a sufficient amount (> 90%) of the solids in the Tank 11.1 and 12.2 solutions will be removed to prevent any problems. We based this conclusion on the particle size distribution of the solids isolated from samples of the solutions and the calculation of particle settling times in the centrifuge. The particle size distributions were calculated from images generated by scanning electron microscopy (SEM). The mean particle diameters for the distributions were 1-3 {micro}m. A significant fraction (30-50%) of the particles had diameters which were < 1 {micro}m; however, the mass of these solids is insignificant (< 1% of the total solids mass) when compared to particles with larger diameters. It is also probable that the number of submicron particles was overestimated by the software used to generate the particle distribution due to the morphology of the filter paper used to isolate the solids. The settling times calculated for the H-Canyon centrifuge showed that particles with diameters less than 1 to 0.5 {micro}m will not have sufficient time to settle. For this reason, we recommend the use of a gelatin strike to coagulate the submicron particles and facilitate their removal from the solution; although we have no experimental basis to estimate the level of improvement. Incomplete removal of particles with diameters < 1 {micro}m should not cause problems during purification of the HEU in the 1st Cycle solvent extraction. Particles with diameters > 1 {micro}m account for > 99% of the solid mass and will be efficiently removed by the centrifuge; therefore, the formation of emulsions during solvent extraction operations is not an issue. Under the current processing plan, the solutions from Tanks 11.1 and 12.2 will be transferred to the enriched uranium storage (EUS) tank following centrifugation. The solution from Tanks 11.1 and 12.2 may remain in the EUS tank for an extended time prior to purification. The effects of extended storage on the solution were not evaluated as part of this study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Final Report - "Foaming and Antifoaming and Gas Entrainment in Radioactive Waste Pretreatment and Immobilization Processes"

The Savannah River Site (SRS) and Hanford site are in the process of stabilizing millions of gallons of radioactive waste slurries remaining from production of nuclear materials for the Department of Energy (DOE). The Defense Waste Processing Facility (DWPF) at SRS is currently vitrifying the waste in borosilicate glass, while the facilities at the Hanford site are in the construction phase. Both processes utilize slurry-fed joule-heated melters to vitrify the waste slurries. The DWPF has experienced difficulty during operations. The cause of the operational problems has been attributed to foaming, gas entrainment and the rheological properties of the process slurries. The rheological properties of the waste slurries limit the total solids content that can be processed by the remote equipment during the pretreatment and meter feed processes. Highly viscous material can lead to air entrainment during agitation and difficulties with pump operations. Excessive foaming in waste evaporators can cause carryover of radionuclides and non-radioactive waste to the condensate system. Experimental and theoretical investigations of the surface phenomena, suspension rheology and bubble generation of interactions that lead to foaming and air entrainment problems in the DOE High Level and Low Activity Radioactive Waste separation and immobilization processes were pursued under this project. The first major task accomplished in the grant proposal involved development of a theoretical model of the phenomenon of foaming in a three-phase gas-liquid-solid slurry system. This work was presented in a recently completed Ph.D. thesis (9). The second major task involved the investigation of the inter-particle interaction and microstructure formation in a model slurry by the batch sedimentation method. Both experiments and modeling studies were carried out. The results were presented in a recently completed Ph.D. thesis. The third task involved the use of laser confocal microscopy to study the effectiveness of three slurry rheology modifiers. An effective modifier was identified which resulted in lowering the yield stress of the waste simulant. Therefore, the results of this research have led to the basic understanding of the foaming/antifoaming mechanism in waste slurries as well as identification of a rheology modifier, which enhances the processing throughput, and accelerates the DOE mission. The objectives of this research effort were to develop a fundamental understanding of the physico-chemical mechanisms that produced foaming and air entrainment in the DOE High Level (HLW) and Low Activity (LAW) radioactive waste separation and immobilization processes, and to develop and test advanced antifoam/defoaming/rheology modifier agents. Antifoams/rheology modifiers developed from this research ere tested using non-radioactive simulants of the radioactive wastes obtained from Hanford and the Savannah River Site (SRS).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Convexity of Energy-Like Functions: Theoretical Results and Applications to Power System Operations

Power systems are undergoing unprecedented transformations with increased adoption of renewables and distributed generation, as well as the adoption of demand response programs. All of these changes, while making the grid more responsive and potentially more efficient, pose significant challenges for power systems operators. Conventional operational paradigms are no longer sufficient as the power system may no longer have big dispatchable generators with sufficient positive and negative reserves. This increases the need for tools and algorithms that can efficiently predict safe regions of operation of the power system. In this paper, we study energy functions as a tool to design algorithms for various operational problems in power systems. These have a long history in power systems and have been primarily applied to transient stability problems. In this paper, we take a new look at power systems, focusing on an aspect that has previously received little attention: Convexity. We characterize the domain of voltage magnitudes and phases within which the energy function is convex in these variables. We show that this corresponds naturally with standard operational constraints imposed in power systems. We show that power of equations can be solved using this approach, as long as the solution lies within the convexity domain. We outline various desirable properties of solutions in the convexity domain and present simple numerical illustrations supporting our results.

24 POWER TRANSMISSION AND DISTRIBUTION↗