Search NASA⌕ Search

SEARCH · Search NASA

Results for “OPTICAL EQUIPMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Optics-Free Chip-Scale Intraoperative Imaging Using NIR-Excited Upconverting Nanoparticles

Here we present an optics-free CMOS image sensor that incorporates a novel time-gated dual-photodiode pixel design to allow filter- and lens-less image acquisition of near-infrared-excited (NIR-excited) upconverting nanoparticles. Recent biomedical advances have highlighted the benefits of NIR excitation, but NIR interaction with silicon has remained a challenge, even with high-performance optical blocking filters. Using a secondary diode and a dual-photodiode design, this sensor is able to remove the 100s of mV of NIR background on pixels and bring it down to single-digit mV level, nearing its noise floor of 2.2 mV rms, not achievable with any optical filter. Non-linear effects of background cancellation using the diode pair has been mitigated using an initial one-time pixel-level curve fitting and calibration in a post-processing setting. This imager comprises a highly linear 11 fF metal-oxide-metal (MOM) capacitor and includes integrated angle-selective gratings to reject oblique light and enhance sharpness. Each pixel also includes two distinct correlated double sampling schemes, to remove low frequency flicker noise and systematic offset in the datapath. We demonstrate the performance of this imager using pulsed NIR-excited upconverting nanoparticles on standard United-States-Air-Force (USAF) resolution targets and achieve an SNR of 15 dB, while keeping NIR background below 6 mV. This 36-by-80-pixel array measures only 2.3 mm by 4.8 mm and can be thinned down to 25 µm, allowing it to become surgically compatible with intraoperative instruments and equipment, while remaining optics-free.

42 ENGINEERING↗

Experiments with a prototype titanium hot cavity surface ionization source intended for electromagnetic separation of radioactive samarium and other lanthanide elements

This paper reports experimental results of a prototype titanium surface ionization source. For the first time, a lanthanide ion beam has been produced with a surface ionizer composed completely of titanium metal. Titanium does not readily activate with neutron irradiation. This offers the potential for inserting an ion source made of titanium directly into a reactor with a pre-loaded non-radioactive lanthanide target. This seamlessly integrates target irradiation with isotope separation, eliminating post irradiation sample manipulation. Samarium ion beam currents up to 960 nA have been produced in an off-line test bench equipped with rudimentary beam optics. This is a crucial step toward the development of an ionization source adopted for the electromagnetic isotope separator (EMIS) facility, which has been designed for high throughput separations of radioactive 153 Sm and other lanthanides of interest in the field of nuclear medicine. The ion current and important factors affecting the performance of the ion source, such as the ionizer temperature and thermal gradient, are discussed. Lastly, the experimental results are presented together with a discussion of future modifications to optimize the overall surface ionization source performance.

07 ISOTOPE AND RADIATION SOURCES↗

Copper-nickel electroplating of 3D-printed acrylonitrile butadiene styrene for interference and radiation shielding applications

Here, in this study, electromagnetic and radiation shielding structures were fabricated by 3D printing acrylonitrile butadiene styrene (ABS) structures via fused filament fabrication and electroplating with copper (Cu) and nickel (Ni) metals. Prior to electroplating, the printed ABS materials were made conductive by surface electrodeposition of polypyrrole (PPy). ABS adsorbs the pyrrole monomer, which subsequently polymerizes via oxidation forming conductive PPy layer on the printed structures. The successful anchoring of PPy layer can be attributed to its hydrogen bonding and electrostatic interactions with ABS. Thermal analysis, optical, and electron microscopy equipped with energy dispersive X-ray were employed to characterize the printed shielding structures, while the interference and radiation shielding effectiveness were evaluated using a spectrum analyzer and dosimeter, respectively. The interference shielding was found to be effective at 60 ± 5 dB over relatively small frequency range. Shielding was also apparent against gamma and X-ray ionizing rays, but more significantly effective against beta rays. Furthermore, the Cu/Ni coating was able to reduce any heat-induced dimensional changes for the 3D printed ABS substrate without compromising the mechanical integrity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Correcting aberrations of a transverse-field neutron resonance spin echo instrument

Neutron resonance spin echo (NRSE) technique has the potential to increase the Fourier time and energy resolution in neutron scattering by using radio frequency (rf) neutron spin-flippers. However, aberrations arising from variations in the neutron path length between the rf flippers reduce the polarization. Here, we develop and test a transverse static-field magnet, a series of which are placed between the rf flippers, to correct for these aberrations. The prototype correction magnet was both simulated in an NRSE beamline using McStas, a Monte Carlo neutron ray-tracing software package, and measured using neutrons. The results from the prototype demonstrate that this static-field design corrects for transverse-field NRSE aberrations.

47 OTHER INSTRUMENTATION↗

High power actively Q-switched downhole LIBS analysis systems

An actively Q-switched laser induced breakdown spectroscopy (LIBS) probe, utilizing an optical fiber, a pump beam transmitted through the optical fiber, a coupler, and a lens for collimating the pump beam. The actively Q-switched laser, coupled to a sensor which provides information to a computer that controls a high voltage pulser providing a pulse to a Pockels cell located within the laser which can selectively cause the laser to pulse, resulting in high energy pulses and a second lens for focusing the output pulse such that it creates a plasma or spark. The light from the spark is captured and directed back through an optical system to remote equipment for elemental and/or molecular analysis.

McIntyre, Dustin Langdon↗

Multiwell Fiber Optic Sensing Reveals Effects of CO2 Flow on Triggered Seismicity

Induced seismicity is one of the main risks for gigaton-scale geological storage of carbon dioxide (⁠CO 2 ⁠). Thus, passive seismic monitoring is often recommended as a necessary component of the monitoring systems for CO 2 storage projects, with a particular forcus on risk mitigation. We present the first field study, CO2CRC Otway Project Stage 3 (Victoria, Australia), where distributed acoustic sensing (DAS) enabled high-precision tracking of the induced seismicity triggered by a small CO 2 injection and also informed the reservoir models. In 610 days of passive seismic monitoring of the Stage 3 injection, we detected 17 microseismic events (maximum moment magnitude Mw 0.1) using five deep boreholes equipped with enhanced-sensitivity optical fiber. The DAS array has sensitivity sufficient for detection and location of induced events with M w ~ ₋2 in a monitoring borehole located up to 1500 m away. Thanks to the dense spatial sampling by the DAS, we were able to estimate the focal mechanisms for events with M w > ₋1.5; although the monitoring boreholes provided very limited angular coverage. The main cluster of the events has the same location and source mechanism as the one triggered by the previous CO 2 injection at the Otway Project site, Stage 2C. Surprizingly, the Stage 2C and Stage 3 events closely followed the actual movement of the CO 2 saturation plume front (not the pressure front), as observed using controlled-source reflection seismic images. The nature of the plume-fault interaction remains unclear, but some alteration of the fault gouge by CO 2 might be responsible for the faults’ reactivation by the pressure perturbation. Importantly, the seismogenic fault could not be identified in the seismic images and was only revealed by DAS observations, which also demonstrated the signature of fluid–rock interaction, that may control the CO 2 flow.

58 GEOSCIENCES↗

Experimental evaluation of the vapor box divertor concept with an open vapor box module in Magnum-PSI

A promising approach to handle the intense plasma heat flux in the divertor region of a tokamak is the Vapor Box Divertor (VBD). Here plasma-lithium interaction creates a dense lithium vapor cloud which interacts with the incoming plasma, effectively shielding the tungsten surface beneath, therefore preventing overheating and sputtering of the tungsten and increasing the component’s lifetime. Two key steps must be addressed to validate this concept: investigating plasma-Li interactions and the transport mechanism of the latter in the presence of plasma. To explore this, a Vapor Box Module (VBM) has been designed for use with the linear plasma generator Magnum-PSI. The VBM consists of a series of three cylindrical boxes, with Li being evaporated at a controlled temperature in the central box (CB). Divertor-like plasma enters the VBM from an upstream aperture, interacts with the Li vapor cloud and exits through a downstream aperture ultimately impacting a target equipped with a calorimetry system. Optical diagnostics Thomson scattering, Filtered fast camera Imaging and optical emission spectroscopy provided information on plasma parameters in terms of electron density n e , temperature T e and plasma composition before and after this interaction. A significant reduction in plasma power was observed upon the establishment of lithium vaporization determined via cooling water calorimetry and embedded thermocouples at the downstream target. This resulted in a drop of the target temperature from ∼800 °C to ∼350 °C (57%) at the highest applied power (11.1 MW m −2 ) and CB temperature (∼700 °C). Lithium condensation at the side boxes of the VBM in combination with strong plasma momentum transfer effectively prevented upstream migration of lithium, while enhancing Li transport toward the target. The achievement of the two main goals of reducing plasma power and confining the Li in the VBM, are consistent with earlier published preliminary SOLPS-ITER simulations. This study shows that the presence of lithium in a VBD-like configuration can result in a strong reduction of power to the target surface, while at the same time the lithium vapor is effectively confined by the VBM, aided by the incoming plasma, preventing its escape from the VBM geometry. This represents a valuable step toward validating the feasibility of the VBD configuration in future fusion reactors.

Magnum-PSI↗

Preload Characterization of Short Models of MQXF the Nb 3 Sn Low-β Quadrupole for the Hi-Lumi LHC

MQXF is the Nb3Sn Low-β Quadrupole magnet that the HL-LHC project is planning to install in the LHC interaction regions in 2026 as part of an upgrade to increase the LHC inte-grated luminosity by about a factor of ten. The magnet will be fab-ricated in two different lengths: 4.2 m for MQXFA, built in the US by the Accelerator Upgrade Project (AUP), and 7.15 m for MQXFB, fabricated by CERN. In order to qualify the magnet de-sign and characterize its performance with different conductors, cable geometries and pre-load configuration, five short model magnets, called MQXFS, were fabricated, assembled and tested. The latest model, MQXFS6, uses a new powder-in-tube (PIT) su-perconducting wire, featuring a bundle barrier surrounding the filaments. The coil and the support structure were equipped with strain gauges and optical fibres to monitor strain during assembly, cool-down and excitation. In this paper we further develop the conventional azimuthal preload analysis and introduce a new set of tools for MQXF coil pack characterization which we use to an-alyse the behaviour of MQXFS6 room temperature preload and to reanalyse all the short models tested at CERN. A comparison is made between all the studied magnets revealing new characteriz-ing preload parameters.

43 PARTICLE ACCELERATORS↗

Temperature Controlled Glass Additive Manufacturing

Glass additive manufacturing (AM) is an emerging technology with a wide range of applications in chemistry, biology, optical science, and engineering. A custom laser-based glass 3D printer was developed by a group of engineers at Los Alamos National Laboratory (LANL) and is being optimized to produce hardware for chemical processing equipment, microfluidic systems, as well as optical elements. AM glass using a filament deposition modeling (FDM) approach allows for generation of parts with high optical quality. The quality of the glass can be affected by the generation of defects such as bubbles and vaporization which affect the optical quality of the glass. The defects can also affect the mechanical performance of the glass and lead to sample cracking.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Upgrades to the Thomson Scattering Diagnostic on the Lithium Tokamak eXperiment-Beta (LTX-$β$)

We describe the upgrades to the Thomson scattering (TS) diagnostic on the Lithium Tokamak eXperiment-beta (LTX- β ) to provide complete radial coverage of the plasma. LTX- β is a spherical tokamak with plasma limited at a major radius of R = 14 cm and R = 66 cm. Flat temperature profiles with peaked density were observed in LTX- β using an existing multipoint TS diagnostic with radial coverage of the plasma core. There is a need for more comprehensive core and edge TS measurements to thoroughly examine beam fueling, beam heating, and transport under low recycling conditions with liquid lithium walls and a lower collisionality scrape-off layer (SOL). The core TS set up provides plasma profiles from R = 40–60 cm. To extend the TS diagnostic coverage: 1) we added a TS viewing optics to cover the SOL region at five radial points from R = 57–64 cm, and 2) another TS viewing optics in the HFS region from R = 15–45 cm to obtain TS data from ten radial positions while making use of the original laser beam. The main focus of this article is on the new HFS TS setup that is equipped with better-matched collection optics located in the horizontal midplane where the laser polarization lies and views from a scattering angle of 130°–150° with respect to the laser path. A set of unequal-length Y-branched fiber bundles transports the TS light from two radial points to each polychromator. The new HFS view is better matched in spot size, scattering angle, and throughput to the laser and polychromators and has new V-grooved style viewing dumps. The new HFS TS view, along with the core and SOL TS views, will provide a full radial measurement coverage from R = 15–64 cm to explore the flat temperature profiles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rapid Prototyping for Nanoparticle-Based Photonic Crystal Fiber Sensors

The advent of nanotechnology has motivated a revolution in the development of miniaturized sensors. Such sensors can be used for radiation detection, temperature sensing, radio-frequency sensing, strain sensing, and more. At the nanoscale, integrating the materials of interest into sensing platforms can be a common issue. One promising platform is photonic crystal fibers, which can draw in optically sensitive nanoparticles or have its optical properties changed by specialized nanomaterials. However, testing these sensors at scale is limited by the the need for specialized equipment to integrate these photonic crystal fibers into optical fiber systems. Having a method to enable rapid prototyping of new nanoparticle-based sensors in photonic crystal fibers would open up the field to a wider range of laboratories that could not have initially studied these materials in such a way before. This manuscript discusses the improved processes for cleaving, drawing, and rapidly integrating nanoparticle-based photonic crystal fibers into optical system setups. The method proposed in this manuscript achieved the following innovations: cleaving at a quality needed for nanoparticle integration could be done more reliably (≈100% acceptable cleaving yield versus ≈50% conventionally), nanoparticles could be drawn at scale through photonic crystal fibers in a safe manner (a method to draw multiple photonic crystal fibers at scale versus one fiber at a time), and the new photonic crystal fiber mount was able to be finely adjusted when increasing the optical coupling before inserting it into an optical system (before, expensive fusion splicing was the only other method).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of nitriding on mechanical and microstructural properties of Direct Metal Laser Sintered 17-4PH stainless steel

In this work, the effect of the nitriding process on microstructure and mechanical properties of additively manufactured (AM) 17-4PH stainless steel is investigated. The nitriding was performed at 530 °C, 560 °C, and 580 °C for 2 h. The nitriding process improves the hardness and surface roughness of the AM 17-4PH steel. Detailed microstructural characterizations of both as-built and nitride samples are performed using an optical microscope, scanning electron microscope (SEM) equipped with energy-dispersive X-ray spectroscopy (EDS), and X-ray diffraction technique. It reveals that the nitride layer thickness increases with nitriding temperature. A distinct transition layer between the substrate and nitride layer is observed in the 560 °C and 580 °C nitride samples. The nitriding process develops almost equiaxed grain microstructure with new secondary phase precipitates, whereas in the as-built material, the grains are primarily columnar along the AM process build direction. Specifically, the nitriding process introduces γ-Fe4N, ε-Fe3N, CrN, and Ni3N precipitates. The increase in Ni- and Cu-rich precipitates with the nitriding temperature explains the observed improvement in the hardness and surface roughness. Furthermore, the nitriding process does not alter the substrate's initial weak crystallographic texture.

17-4PH steel↗

Harmonizing solar induced fluorescence across spatial scales, instruments, and extraction methods using proximal and airborne remote sensing: A multi-scale study in a soybean field

Solar-induced chlorophyll fluorescence (SIF) has been widely used to track vegetation photosynthesis at different scales ranging from in-situ measurements to satellite products. Airborne platforms sample SIF data at a spatial scale intermediate between in-situ and satellite, matching that of ground measurement (e.g. flux tower footprints and other field sampling), enabling us to explore causes of SIF variation and validate satellite-based SIF products. However, harmonizing SIF across sensors and platforms (correcting for systematic errors to yield a consistent, comparable SIF product) is challenging because SIF can be retrieved in different absorption windows, with different instruments and methods complicating the comparison between different observational levels (i.e., ground, airborne, satellites) and between sites equipped with different instruments with varying optical properties (spectral resolution and sampling intervals, spatial resolution). Additionally, the spatial and temporal variability of atmospheric properties can influence the retrieval of the weak SIF signal. Because of these complications, direct comparisons of airborne and ground SIF across scales are rarely attempted. Here, in this study, we combined airborne SIF data with simultaneous ‘ground truth’ data collected by stationary and mobile platforms in a soybean field in Nebraska, USA. In this effort, we tested several SIF extraction methods, including Fraunhofer Line Discrimination (FLD), improved Fraunhofer Line Discrimination (iFLD), Spectral Fitting Method (SFM), SpecFit, and a Singular Vector Decomposition (SVD) method. The SpecFit method was sensitive to the 715–740 nm water bands and removing the water bands in the fitting process yielded better agreement between the airborne and ground SIF spectra. Accurate estimation of the ground level downwelling irradiance obtained by ground measurements over a calibration target improved agreement between airborne and ground SIF retrievals at the O 2 A band, and allowed us to derive a SIF dataset with improved agreement across platforms and sampling scales. This experimental approach provided a method for generating comparable SIF signals across instruments, methods and platforms, which is critical to understanding the SIF-GPP relationship at different scales and to cross-validate the diversity of platforms used for satellite products calibration and validation.

54 ENVIRONMENTAL SCIENCES↗

Using deep machine learning to interpret proton radiography data from a pulsed power experiment

Deep machine learning is used to analyze a proton radiograph from a tin pulsed power experiment and determine density values for each pixel in the image. Two promising convolutional neural network architectures that have proven to be effective for image analysis in other applications are applied to analyze a proton radiograph and find density values. The process of creating a suitable training dataset is described, involving the Lagrangian hydrodynamic model used for simulations of the experiment, the proton radiography forward model to make synthetic images for training, and the manner in which data augmentation is used to expand the resulting image dataset. It is shown that machine learning not only produces a reasonable density field but is also able to predict features in the density field that are suggested by the proton radiograph but not captured by simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tomographic imaging of atmospheric pressure plasma on complex surfaces

Many plasma types and behaviors such as streamer, arcs, cathode spots, anode spots, ionization waves, and magnetic field interactions create non-symmetric, fully 3D plasma structures. The plasma distribution in 3D space is heavily influenced by complex surfaces and the coupling interactions between plasma properties and the interfacing material properties. For example, ionization waves propagate in directions where ionization rates are highest, leading to complex configurations that are not fully understood or well characterized. Recent advances in laser diagnostics and models have been able to investigate well-controlled idealized plasmas in 2D fashion, but the complex structure in actual plasmas requires a technique than can provide a more complete 3D picture. However, 3D plasma diagnostics do not currently exist. To address this limitation, this activity will leverage available equipment to build a new tomographic optical imaging capability and advance the state-of-the-art in plasma diagnostics to investigate 3D phenomena on complex surfaces.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pre-commissioning of the wide-dynamic range halo monitor to be installed in the Fermilab MI-8 line

The beam halo can contribute to beam losses in accelerators and is very difficult to measure. With an increase in beam intensity following the PIP-II upgrade at Fermilab, the beam losses are expected to be higher with some coming from beam halo. Therefore, it is important to measure the sources of beam halo to minimize the beam losses. A modified Halo Monitor developed by J-PARC will be installed in Fermilab MI-8 transfer line to measure the beam halo. In this paper, an update on the beam profile monitor fabrication is covered. The updates include the location selection for the Halo Monitor in the MI-8 transfer line, shielding options for instrumentation, initial testing of equipment, and ray tracing simulations for the Offner optics and the targets used in the monitor.

Babacan, Betiay [IIT, Chicago; Fermilab]↗

Implementation of a portable diagnostic system for Thomson scattering measurements on an electrothermal arc source

To fulfill the increasing needs of diagnostic support for researchers in plasma technology, a portable diagnostic package (PDP) equipped for both laser Thomson scattering (TS) and optical emission spectroscopy has been designed and constructed at Oak Ridge National Laboratory (ORNL), aiming to measure the temperature and number density of electrons and temperatures of ions in plasma devices. The PDP has been initially implemented on a high density and low temperature electrothermal arc source (ET-arc) at ORNL to test its TS capability. TS from the plasmas in the ET-arc has been obtained using the PDP. The electron temperature and number density were determined from TS spectra. These results were then compared to measurements from previous studies on the ET-arc. The TS diagnostic measured 0.8 ± 0.1, 1.3 ± 0.2, and 0.7 ± 0.1 eV and (4.4 ± 0.5) × 1021, (5.9 ± 0.7) × 1021, and (4.3 ± 0.5) x 1021 m-3, respectively, from three lines of sight that transect the plasma column.

He, Z. (ORCID:0000000183159882)↗