Search NASA⌕ Search

SEARCH · Search NASA

Results for “OXYGEN SENSOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Hydrogen and oxygen sensor development

A reliable and low cost gas sensor was investigated for instantaneously detecting H2 in N2, H2 in air, and O2 in N2. The major portion of the research was spent in developing a sensor which would instantaneously detect H2 to + or - 50 ppm even in the presence of trace amounts of other gases. The experimental procedures used to provide the performance characteristics for the various oscillators are discussed describing the equipment with help of schematics and photographs where applicable. The resulting performance is given in graphical form. In some cases both hydrogen and helium may be present and since both of them effect gas sensors similarly, a method was found to determine the concentration of each. The methods developed are grouped into the following four broad categories: pure metal response, variation in heat conductivity, reduction methods, and exotic processes. From the above it was decided for the present to use a copper oxide reduction process as this process was demonstrated to be capable of determining the concentrations of hydrogen and helium respectively in a gas mixture with air or nitrogen.

Farber, E. A.↗

Synthesis and Characterization of Ru(II) Tris(1,1O-phenanthroline)-Electron Acceptor Dyads Incorporating the 4-benzoyl-N-methylpyridinium Cation or N-Benzyl-N'-methyl-viologen. Improving the Dynamic Range, Sensitivity and Response Time of Sol-Gel Based Optical Oxygen Sensors

The title compounds (1 and 2, above) were synthesized by Sonogashira coupling reactions of appropriate Ru(1I) complexes with the electron a cceptors. Characterization was conducted in solution and in frozen ma trices. Finally, the title compounds were evaluated as dopants of sol-gel materials. It was found that the intramolecular quenching efficie ncy of 4-benzoyl-Nmethylpyridinium cation in solution depends on the solvent: photoluminescence is quenched completely in CH,CN, but not i n methanol or ethanol. On the other hand, intramolecular emission que nching by 4-benzyl-N-methyl viologen is complete in all solvents. The difference between the two quenchers is traced electrochemically to t he solvation of the 4-benzoyl-Nmethylpyridiniums by alcohol. In froze n matrices or adsorbed on the surfaces of silica aerogel, both Ru(I1) complex/electron acceptor dyads of this study are photoluminescent, and the absence of quenching has been traced to the environmental rigi dity. When doped aerogels are cooled at 77 K, the emission intensity increases by approximately 4x, and the spectra shift to the blue, analogous to what is observed with Ru(I1) complexes in solutions undergoi ng fluid-to-rigid transition. However, in contrast to frozen solution s, the luminescent moieties in the bulk of aerogels kept at low tempe ratures are still accessible to gas-phase quenchers diffusing through the mesopores, leading to more sensitive platforms for sensors than o ther room-temperature configurations. Thus the photoluminescence of o ur Ru(I1) complex dyads adsorbed on aerogel is quenchable by O2 both at room temperature and at 77 K. Furthermore, it was also found that O 2 modulates the photoluminescence of aerogels doped with 4-benzoyl -N -methylpyridinium-based dyads over a wider dynamic range compared wi th aerogels doped with either our vislogen-based dyads or with Ru(I1) tris(1,lO-phenanthroline) itself.

Leventis, Nicholas↗

Effects of Oxygen Partial Pressure on the Surface Tension of Liquid Nickel

The NASA Marshall Space Flight Center's electrostatic levitation (ESL) laboratory has been recently upgraded with an oxygen partial pressure controller. This system allows the oxygen partial pressure within the vacuum chamber to be measured and controlled, theoretically in the range from 10‐36 to 100 bar. The oxygen control system installed in the ESL laboratory's main chamber consists of an oxygen sensor, oxygen pump, and a control unit. The sensor is a potentiometric device that determines the difference in oxygen activity in two gas compartments (inside the chamber and the air outside of the chamber) separated by an electrolyte, which is yttria‐stabilized zirconia. The pump utilizes coulometric titration to either add or remove oxygen. The system is controlled by a desktop control unit, which can also be accessed via a computer. The controller performs temperature control for the sensor and pump, PID-based current loop, and a control algorithm. Oxygen partial pressure has been shown to play a significant role in the surface tension of liquid metals. Oxide films or dissolved oxygen may lead to significant changes in surface tension. The effects of oxygen partial pressure on the surface tension of undercooled liquid nickel will be analyzed, and the results will be presented. The surface tension will be measured at several different oxygen partial pressures while the sample is undercooled. Surface tension will be measured using the oscillating drop method. While undercooled, each sample will be oscillated several times consecutively to investigate how the surface tension behaves with time while at a particular oxygen partial pressure.

SanSoucie, Michael P.↗

The NASA MSFC Electrostatic Levitation (ESL) Laboratory: Summary of Capabilities, Recent Upgrades, and Future Work

The NASA Marshall Space Flight Center (MSFC) electrostatic levitation (ESL) laboratory has a long history of providing materials research and thermophysical property data. A summary of the labs capabilities, recent upgrades, and ongoing and future work will be provided. The laboratory has recently added two new capabilities to its main levitation chamber: a rapid quench system and an oxygen control system. The rapid quench system allows samples to be dropped into a quench vessel that can be filled with a low melting point material, such as a gallium or indium alloy. Thereby allowing rapid quenching of undercooled liquid metals. The oxygen control system consists of an oxygen sensor, oxygen pump, and a control unit. The sensor is a potentiometric device that determines the difference in oxygen activity between two gas compartments separated by an electrolyte, which is yttria-stabilized zirconia. The pump utilizes coulometric titration to either add or remove oxygen. The system is controlled by a desktop control unit, which can also be accessed via a computer. This system allows the oxygen partial pressure within the vacuum chamber to be measured and controlled, theoretically in the range from 10-36 to 100 bar. The ESL laboratory also has an emissometer, called the High-Temperature Emissivity Measurement System (HiTEMS). This system measures the spectral emissivity of materials from 600degC to 3,000degC. The system consists of a vacuum chamber, a black body source, and a Fourier Transform Infrared Spectrometer (FTIR). The system utilizes optics to swap the signal between the sample and the black body. The system was originally designed to measure the hemispherical spectral emissivity of levitated samples, which are typically 2.5mm spheres. Levitation allows emissivity measurements of molten samples, but more work is required to develop this capability. The system is currently setup measure the near-normal spectral emissivity of stationary samples, which has been used to take measurements of ablative materials, rocket nozzle coating materials, and materials for spacecraft instruments.

SanSoucie, Michael P.↗

Effects of varying oxygen partial pressure on molten silicon-ceramic substrate interactions

The silicon sessile drop contact angle was measured on hot pressed silicon nitride, silicon nitride coated on hot pressed silicon nitride, silicon carbon coated on graphite, and on Sialon to determine the degree to which silicon wets these substances. The post-sessile drop experiment samples were sectioned and photomicrographs were taken of the silicon-substrate interface to observe the degree of surface dissolution and degradation. Of these materials, silicon did not form a true sessile drop on the SiC on graphite due to infiltration of the silicon through the SiC coating, nor on the Sialon due to the formation of a more-or-less rigid coating on the liquid silicon. The most wetting was obtained on the coated Si3N4 with a value of 42 deg. The oxygen concentrations in a silicon ribbon furnace and in a sessile drop furnace were measured using the protable thoria-yttria solid solution electrolyte oxygen sensor. Oxygen partial pressures of 10 to the minus 7 power atm and 10 to the minus 8 power atm were obtained at the two facilities. These measurements are believed to represent nonequilibrium conditions.

Ownby, D. P.↗

Oxygen-Partial-Pressure Sensor for Aircraft Oxygen Mask

A device that generates an alarm when the partial pressure of oxygen decreases to less than a preset level has been developed to help prevent hypoxia in a pilot or other crewmember of a military or other high-performance aircraft. Loss of oxygen partial pressure can be caused by poor fit of the mask or failure of a hose or other component of an oxygen distribution system. The deleterious physical and mental effects of hypoxia cause the loss of a military aircraft and crew every few years. The device is installed in the crewmember s oxygen mask and is powered via communication wiring already present in all such oxygen masks. The device (see figure) includes an electrochemical sensor, the output potential of which is proportional to the partial pressure of oxygen. The output of the sensor is amplified and fed to the input of a comparator circuit. A reference potential that corresponds to the amplified sensor output at the alarm oxygen-partial-pressure level is fed to the second input of the comparator. When the sensed partial pressure of oxygen falls below the minimum acceptable level, the output of the comparator goes from the low state (a few millivolts) to the high state (near the supply potential, which is typically 6.8 V for microphone power). The switching of the comparator output to the high state triggers a tactile alarm in the form of a vibration in the mask, generated by a small 1.3-Vdc pager motor spinning an eccentric mass at a rate between 8,000 and 10,000 rpm. The sensation of the mask vibrating against the crewmember s nose is very effective at alerting the crewmember, who may already be groggy from hypoxia and is immersed in an environment that is saturated with visual cues and sounds. Indeed, the sensation is one of rudeness, but such rudeness could be what is needed to stimulate the crewmember to take corrective action in a life-threatening situation.

Kelly, Mark↗

VfOx in GEER: Functional Test of a Venus Oxygen Fugacity Sensor

VfOx, which stands for “Venus Oxygen Fugacity” is the DAVINCI mission’s Student Collaboration Experiment (SCE); a small single- objective sensor used to measure the partial pressure of molecular oxygen in Venus’ lower atmosphere. Through the mission timeline, VƒOx will be designed, fabricated, tested, operated, and results analyzed by undergraduate and graduate students mentored by the DAVINCI team in partnership with Johns Hopkins University and other institutions. The simple principal of VƒOx is a ceramic O 2 sensor derived from common applications, utilizing diffusion of O -2 ions between a standard (PdO) inside the sensor and the target atmosphere measured by a mW level voltage that depends directly on the standard/sample fO 2 ratio. A 60-day environmental test of a prototype design of the sensor was conducted at the Glenn Extreme Environment Rig (GEER) from August to October of 2022, in which VƒOx (Fig. 1) was placed inside the experimental chamber (Fig. 2) and brought to Venus surface temperature (460 °C) and pressure (92 bar) conditions, in a Venus like atmosphere (96.5% CO 2 , 3.5% N 2 ) that included trace gases like SO 2 , maintained by occasional “boosts” of extra gas during the experimental run.

Noam R. Izenberg↗

An oxygen pressure sensor using surface acoustic wave devices

Surface acoustic wave (SAW) piezoelectric devices are finding widespread applications in many arenas, particularly in the area of chemical sensing. We have developed an oxygen pressure sensor based on coating a SAW device with an oxygen binding agent which can be tailored to provide variable sensitivity. The coating is prepared by dissolving an oxygen binding agent in a toluene solution of a copolymer which is then sprayed onto the surface of the SAW device. Experimental data shows the feasibility of tailoring sensors to measure the partial pressure of oxygen from 2.6 to 67 KPa (20 to 500 torr). Potential applications of this technology are discussed.

Leighty, Bradley D.↗

Effect of Multiple Oxygen Vacancies on the Optical and Thermodynamic Properties of La 0.75 Sr 0.25 Co 0.25 Fe 0.75 O 3-δ Perovskite

We report the oxygen vacancy concentration of perovskite changes with the work condition in applications such as oxygen carriers and oxygen sensors. To explore the effect of multiple oxygen vacancies on the optical and thermodynamic properties, we perform first-principles calculations to investigate the formation of multiple oxygen vacancies in the paramagnetic La 0.75 Sr 0.25 Co 0.25 Fe 0.75 O 3-δ . Our results show that the higher VO concentration in La 0.75 Sr 0.25 Co 0.25 Fe 0.75 O 3-δ occurs at the conditions of higher temperatures and lower oxygen partial pressures. The electrons liberated upon oxygen vacancy formation are partially localized on the nearby Fe/Co sites and partially delocalized through the lattice, with the result that the unoccupied Fe/Co states near the Fermi level decrease and the Fermi level shows an upward shift. From the results of optical absorption, the peaks from 250 to 600 nm are weakened and blue-shifted with increase of oxygen vacancy concentration, due to the decrease of empty Fe states and an upward shift of the Fermi level. The obvious change of optical absorption with oxygen vacancy concentration indicates that La 0.75 Sr 0.25 Co 0.25 Fe 0.75 O 3-δ could be a good candidate for optical oxygen sensors in the visible spectrum.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface acoustic wave oxygen pressure sensor

A transducer for the measurement of absolute gas-state oxygen pressure from pressures of less than 100 Pa to atmospheric pressure (1.01 x 10(exp 5) Pa) is based on a standard surface acoustic wave (SAW) device. The piezoelectric material of the SAW device is coated with a compound which will selectively and reversibly bind oxygen. When oxygen is bound by the coating, the mass of the coating increases by an amount equal to the mass of the bound oxygen. Such an increase in the mass of the coating causes a corresponding decrease in the resonant frequency of the SAW device.

Oglesby, Donald M.↗

Small-scale physics of the ocean

Observations and theoretical models of small-scale phenomena in the oceans are reviewed, with a focus on progress during the period 1983-1986. Topics examined include surface layers, equatorial turbulence, off-equator mixed layers, the scaling of mixing, turbulence concepts, laboratory results, internal waves and mixing, rings, the nature of the bottom layer, double diffusion and intrusions, salt fingers, and biological interactions. Also discussed are developments in instrumentation (fast sampling profilers with upward-profiling capability, deep profilers, ship-motion correction, horizontal samplers, small submersibles, submarines, towed packages, conductivity sensors, dissolved-oxygen sensors, and acoustic Doppler current profilers) and goals for future research.

Caldwell, Douglas R.↗

High-Temperature Gas Sensor Array (Electronic Nose) Demonstrated

The ability to measure emissions from aeronautic engines and in commercial applications such as automotive emission control and chemical process monitoring is a necessary first step if one is going to actively control those emissions. One single sensor will not give all the information necessary to determine the chemical composition of a high-temperature, harsh environment. Rather, an array of gas sensor arrays--in effect, a high-temperature electronic "nose"--is necessary to characterize the chemical constituents of a diverse, high-temperature environment, such as an emissions stream. The signals produced by this nose could be analyzed to determine the constituents of the emission stream. Although commercial electronic noses for near-room temperature applications exist, they often depend significantly on lower temperature materials or only one sensor type. A separate development effort necessary for a high-temperature electronic nose is being undertaken by the NASA Glenn Research Center, Case Western Reserve University, Ohio State University, and Makel Engineering, Inc. The sensors are specially designed for hightemperature environments. A first-generation high-temperature electronic nose has been demonstrated on a modified automotive engine. This nose sensor array was composed of sensors designed for hightemperature environments fabricated using microelectromechanical-systems- (MEMS-) based technology. The array included a tin-oxide-based sensor doped for nitrogen oxide (NOx) sensitivity, a SiC-based hydrocarbon (CxHy) sensor, and an oxygen sensor (O2). These sensors operate on different principles--resistor, diode, and electrochemical cell, respectively--and each sensor has very different responses to the individual gases in the environment. A picture showing the sensor head for the array is shown in the photograph on the left and the sensors installed in the engine are shown in the photograph on the right. Electronics are interfaced with the sensors for temperature control and signal conditioning, and packaging designed for high temperatures is necessary for the array to survive the engine environment.

Hunter, Gary W.↗

Isolating Gas Sensor From Pressure And Temperature Effects

Two-stage flow system enables oxygen sensor in system to measure oxygen content of low-pressure, possibly-high-temperature atmosphere in test environment while protecting sensor against possibly high temperature and fluctuations in pressure of atmosphere. Sensor for which flow system designed is zirconium oxide oxygen sensor sampling atmospheres in high-temperature wind tunnels. Also adapted to other gas-analysis instruments that must be isolated from pressure and temperature effects of test environments.

Sprinkle, Danny R.↗

Using Vanadium in Spinel as a Sensor of Oxygen Fugacity in Meteorites: Applications to Mars, Vesta, and Other Asteroids

Igneous and metamorphic rocks commonly contain a mineral assemblage that allows oxygen fugacity to be calculated or constrained such as FeTi oxides, olivine-opx-spinel, or some other oxybarometer [1]. Some rocks, however, contain a limited mineral assemblage and do not provide constraints on fO2 using mineral equilibria. Good examples of the latter are orthopyroxenites or dunites, such as diogenites, ALH 84001, chassignites, or brachinites. In fact it is no surprise that the fO2 of many of these samples is not well known, other than being "reduced" and below the metal saturation value. In order to bridge this gap in our understanding, we have initiated a study of V in chromites in natural meteorite samples. Because the V pre-edge peak intensity and energy in chromites varies with fO2 (Fig. 1) [2], and this has been calibrated over a large fO 2 range, we can apply this relation to rocks for which we otherwise have no fO2 constraints.

Righter, K.↗