At least 37 records · Page 2

Cardiac beta-adrenergic receptors and coronary hemodynamics in the conscious dog during hypoxic hypoxia.

The mechanisms by which acute hypoxia (10% and 5% oxygen) mediates changes in coronary blood flow and cardiac function were investigated in the conscious dog. When the dogs breathed hypoxic gas mixtures through a tracheostomy, both arterial and coronary sinus oxygen tensions were significantly decreased. With 5% oxygen, there were significant increases in heart rate (25%), maximum left ventricular dP/dt (39%), left circumflex coronary artery blood flow (163%), and left ventricular oxygen consumption (52%), which were attenuated by beta-adrenergic blockage with propranolol. When electrical pacing was used to keep the ventricular rate constant during hypoxia, there was no significant difference in coronary blood flow before and after beta blockade. Beta-adrenergic receptor activity in the myocardium participates in the integrated response to hypoxia although it may not cause active vasodilation of the coronary vessels.

Erickson, H. H.↗

Dynamic regulation of erythropoiesis: A computer model of general applicability

A mathematical model for the control of erythropoiesis was developed based on the balance between oxygen supply and demand at a renal oxygen detector which controls erythropoietin release and red cell production. Feedback regulation of tissue oxygen tension is accomplished by adjustments of hemoglobin levels resulting from the output of a renal-bone marrow controller. Special consideration was given to the determinants of tissue oxygenation including evaluation of the influence of blood flow, capillary diffusivity, oxygen uptake and oxygen-hemoglobin affinity. A theoretical analysis of the overall control system is presented. Computer simulations of altitude hypoxia, red cell infusion hyperoxia, and homolytic anemia demonstrate validity of the model for general human application in health and disease.

Leonard, J. I.↗

Hydrogen Fluxes from Photosynthetic Communities: Implications for Early Earth Biogeochemistry

More than half the history of life on Earth was dominated by photosynthetic microbial mats, which must have represented the preeminent biological influence on global geochemical cycling during that time. In modem analogs of then ancient communities, hypersaline microbial mats from Guerrero Negro, Mexico, we have observed a large flux of molecular hydrogen originating in the cyanobacteria-dominated surface layers. Hydrogen production follows a distinct diel pattern and is sensitive to both oxygen tension and microbial species composition within the mat. On an early Earth dominated by microbial mats, the observed H2 fluxes would scale to global levels far in excess of geothermal emissions. A hydrogen flux of this magnitude represents a profound transmission of reducing power from oxygenic photosynthesis, both to the anaerobic biosphere, where H2 is an almost universally-utilized substrate and regulator of microbial redox chemistry, and to the atmosphere, where subsequent escape to space could provide an important mechanism for the net oxidation of Earth's surface.

Hoehler, Tori M.↗

User's instructions for the erythropoiesis regulatory model

The purpose of the model provides a method to analyze some of the events that could account for the decrease in red cell mass observed in crewmen returning from space missions. The model is based on the premise that erythrocyte production is governed by the balance between oxygen supply and demand at a renal sensing site. Oxygen supply is taken to be a function of arterial oxygen tension, mean corpuscular hemoglobin concentration, oxy-hemoglobin carrying capacity, hematocrit, and blood flow. Erythrocyte destruction is based on the law of mass action. The instantaneous hematocrit value is derived by integrating changes in production and destruction rates and accounting for the degree of plasma dilution.

Source record↗

Application of gain scheduling to the control of batch bioreactors

The implementation of control algorithms to batch bioreactors is often complicated by the inherent variations in process dynamics during the course of fermentation. Such a wide operating range may render the performance of fixed gain PID controllers unsatisfactory. In this work, a detailed study on the control of batch fermentation is performed. Furthermore, a simple batch controller design is proposed which incorporates the concept of gain-scheduling, a subclass of adaptive control, with oxygen uptake rate as an auxiliary variable. The control of oxygen tension in the biorector is used as a vehicle to convey the proposed idea, analysis and results. Simulation experiments indicate significant improvement in controller performance can be achieved by the proposed approach even in the presence of measurement noise.

Cardello, Ralph↗

Effects of oxygen deprivation on incubated rat soleus muscle

Isolated soleus muscle deprived of oxygen produces more lactate and alanine than oxygen-supplied muscle. Oxygenated muscle synthesized glutamine, while anoxic muscle used this amino acid. Oxygen deprivation decreased adenine nucleotides leading to the efflux of nucleosides. Protein synthesis and degradation responded differently to anoxia. Synthesis almost completely ceased, while proteolysis increased. Therefore, protein degradation in soleus muscle is enhanced when energy supplies and oxygen tension are low.

Fagan, Julie M.↗

Environmental stressors during space flight: potential effects on body temperature

1. Organisms may be affected by many environmental factors during space flight, e.g., acceleration, weightlessness, decreased pressure, changes in oxygen tension, radiofrequency radiation and vibration. 2. Previous studies of change in body temperature--one response to these environmental factors--are reviewed. 3. Conditions leading to heat stress and hypothermia are discussed.

Review↗

Effects of Oxygen Partial Pressure on the Surface Tension of Liquid Nickel

The NASA Marshall Space Flight Center's electrostatic levitation (ESL) laboratory has been recently upgraded with an oxygen partial pressure controller. This system allows the oxygen partial pressure within the vacuum chamber to be measured and controlled, theoretically in the range from 10‐36 to 100 bar. The oxygen control system installed in the ESL laboratory's main chamber consists of an oxygen sensor, oxygen pump, and a control unit. The sensor is a potentiometric device that determines the difference in oxygen activity in two gas compartments (inside the chamber and the air outside of the chamber) separated by an electrolyte, which is yttria‐stabilized zirconia. The pump utilizes coulometric titration to either add or remove oxygen. The system is controlled by a desktop control unit, which can also be accessed via a computer. The controller performs temperature control for the sensor and pump, PID-based current loop, and a control algorithm. Oxygen partial pressure has been shown to play a significant role in the surface tension of liquid metals. Oxide films or dissolved oxygen may lead to significant changes in surface tension. The effects of oxygen partial pressure on the surface tension of undercooled liquid nickel will be analyzed, and the results will be presented. The surface tension will be measured at several different oxygen partial pressures while the sample is undercooled. Surface tension will be measured using the oscillating drop method. While undercooled, each sample will be oscillated several times consecutively to investigate how the surface tension behaves with time while at a particular oxygen partial pressure.

SanSoucie, Michael P.↗

Thermophysical Properties Measurement of High-Temperature Liquids Under Microgravity Conditions in Controlled Atmospheric Conditions

Microgravity conditions have advantages of measurement of surface tension and viscosity of metallic liquids by the oscillating drop method with an electromagnetic levitation (EML) device. Thus, we are preparing the experiments of thermophysical properties measurements using the Materials-Science Laboratories ElectroMagnetic-Levitator (MSL-EML) facilities in the international Space station (ISS). Recently, it has been identified that dependence of surface tension on oxygen partial pressure (Po2) must be considered for industrial application of surface tension values. Effect of Po2 on surface tension would apparently change viscosity from the damping oscillation model. Therefore, surface tension and viscosity must be measured simultaneously in the same atmospheric conditions. Moreover, effect of the electromagnetic force (EMF) on the surface oscillations must be clarified to obtain the ideal surface oscillation because the EMF works as the external force on the oscillating liquid droplets, so extensive EMF makes apparently the viscosity values large. In our group, using the parabolic flight levitation experimental facilities (PFLEX) the effect of Po2 and external EMF on surface oscillation of levitated liquid droplets was systematically investigated for the precise measurements of surface tension and viscosity of high temperature liquids for future ISS experiments. We performed the observation of surface oscillations of levitated liquid alloys using PFLEX on board flight experiments by Gulfstream II (G-II) airplane operated by DAS. These observations were performed under the controlled Po2 and also under the suitable EMF conditions. In these experiments, we obtained the density, the viscosity and the surface tension values of liquid Cu. From these results, we discuss about as same as reported data, and also obtained the difference of surface oscillations with the change of the EMF conditions.

Watanabe, Masahito↗