Search NASA⌕ Search

SEARCH · Search NASA

Results for “Oil Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Future Issues and Approaches to Health Monitoring and Failure Prevention for Oil-Free Gas Turbines

Recent technology advances in foil air bearings, high temperature solid lubricants and computer based modeling has enabled the development of small Oil-Free gas turbines. These turbomachines are currently commercialized as small (<100 kW) microturbine generators and larger machines are being developed. Based upon these successes and the high potential payoffs offered by Oil-Free systems, NASA, industry, and other government entities are anticipating Oil-Free gas turbine propulsion systems to proliferate future markets. Since an Oil-Free engine has no oil system, traditional approaches to health monitoring and diagnostics, such as chip detection, oil analysis, and possibly vibration signature analyses (e.g., ball pass frequency) will be unavailable. As such, new approaches will need to be considered. These could include shaft orbit analyses, foil bearing temperature measurements, embedded wear sensors and start-up/coast down speed analysis. In addition, novel, as yet undeveloped techniques may emerge based upon concurrent developments in MEMS technology. This paper introduces Oil-Free technology, reviews the current state of the art and potential for future turbomachinery applications and discusses possible approaches to health monitoring, diagnostics and failure prevention.

DellaCorte, Christopher↗

A Comparison of Vibration and Oil Debris Gear Damage Detection Methods Applied to Pitting Damage

Helicopter Health Usage Monitoring Systems (HUMS) must provide reliable, real-time performance monitoring of helicopter operating parameters to prevent damage of flight critical components. Helicopter transmission diagnostics are an important part of a helicopter HUMS. In order to improve the reliability of transmission diagnostics, many researchers propose combining two technologies, vibration and oil monitoring, using data fusion and intelligent systems. Some benefits of combining multiple sensors to make decisions include improved detection capabilities and increased probability the event is detected. However, if the sensors are inaccurate, or the features extracted from the sensors are poor predictors of transmission health, integration of these sensors will decrease the accuracy of damage prediction. For this reason, one must verify the individual integrity of vibration and oil analysis methods prior to integrating the two technologies. This research focuses on comparing the capability of two vibration algorithms, FM4 and NA4, and a commercially available on-line oil debris monitor to detect pitting damage on spur gears in the NASA Glenn Research Center Spur Gear Fatigue Test Rig. Results from this research indicate that the rate of change of debris mass measured by the oil debris monitor is comparable to the vibration algorithms in detecting gear pitting damage.

Dempsey, Paula J.↗

Ferrographic analysis of wear debris from full-scale bearing fatigue tests

The Ferrograph was used to determine the types and quantities of wear particles generated during full scale bearing fatigue tests. Deep-groove ball bearings made from steel were used. A tetraester lubricant was used in a recirculating lubricant system containing a 49 micrometers absolute filter. Test conditions include a maximum Hertz stress of 2.4 GPa, a shaft speed of 15,000 rpm, and a lubricant supply temperature of 74 C (165 F). Four fatigue failures were detected by accelerometers in this test set. In general, the Ferrograph was more sensitive (up to 23 hr) in detecting spall initiation than either accelerometers or the normal spectrographic oil analysis. Four particle types were observed: normal rubbing weather particles, spheres, nonferrous particles, and severe wear (spall) fragments.

Jones, W. R., Jr.↗

Analysis of wear debris from full-scale bearing fatigue tests using the Ferrograph

The Ferrograph was used to determine the types of quantities of wear particles generated during full-scale bearing fatigue tests. Deep-groove ball bearings made from AISI 52100 steel were used. A MIL-L-23699 tetraester lubricant was used in a recirculating lubrication system containing a 49-micron absolute filter. Test conditions included a maximum Hertz stress of 2.4 GPa, a shaft speed of 15,000 rpm and a lubricant supply temperature of 74 C (165 F). Four fatigue failures were detected by accelerometers in this test set. In general, the Ferrograph was more sensitive (up to 23 h) in detecting spall initiation than either accelerometers or the normal spectrographic oil analysis (SOAP). Four particle types were observed: normal rubbing wear particles, spheres, nonferrous particles, and severe wear (spall) fragments.

Jones, W. R., Jr.↗

Analysis of wear-debris from full-scale bearing fatigue tests using the ferrograph

The ferrograph was used to determine the types and quantities of wear particles generated during full-scale bearing fatigue tests. Deep-groove ball bearings made from AISI 52100 steel were used. A MIL-L-23699 tetraester lubricant was used in a recirculating lubrication system containing a 49 mm absolute filter. Test conditions included a maximum Hertz stress of 2.4 GPa, a shaft speed of 15,000 rpm, and a lubricant supply temperature of 74 C (165 F). Four fatigue failures were detected by accelerometers in this test set. In general, the ferrograph was more sensitive (up to 23 hr) in detecting spall initiation than either accelerometers or the normal spectrographic oil analysis. Four particle types were observed: normal rubbing wear particles, spheres, nonferrous particles, and severe wear (spall) fragments.

Jones, W. R.↗

Thermoelastohydrodynamic analysis of an oil pumping ring seal

The selection and evaluation of the numerical methods used in the thermoelastohydrodynamic analysis of an oil pumping ring seal are described, and the results from test problems used to demonstrate the validity of the implementing computer program are presented. A sampling of predicted pumping ring performance values is compared with existing experimental data. Agreement between prediction and test performance is obtained, yielding detailed information concerning fluid and solid parameters.

Smith, P. J.↗

Future of Condition Based Maintenance at Stennis

This study seeks to understand the current state of condition based maintenance (CBM) at Stennis Space Center and set a bench mark for the future expansion of the CBM program. Condition based maintenance is the idea of maintaining an asset upon decreasing performance or when a failure is impending instead of at some arbitrary time regardless of condition. Special attention was paid to remote sensing and monitoring of assets around the center to cut maintenance costs and extend overall operational lifetime of those assets. It was found that 55 percent of the categories of assets which could actually utilize a remote CBM program are currently being partially monitored. CBM solutions that have been investigated and proposed for future deployment cover areas such as building integrity, oil analysis, power line and water pipe inspection.

George, Cory A.↗

Simulated 'On-Line' Wear Metal Analysis of Lubricating Oils by X-Ray Fluorescence Spectroscopy

The objective of this project was to assess the sensitivity of X-ray Fluorescence Spectroscopy (XFS) for quantitative evaluation of metal particle content in engine oil suspensions and the feasibility of real-time, dynamic wear metal analysis. The study was focused on iron as the majority wear metal component. Variable parameters were: particle size, particle concentration and oil velocity. A commercial XFS spectrometer equipped with interchangeable static/dynamic (flow cell) sample chambers was used. XFS spectra were recorded for solutions of Fe-organometallic standard and for a series of DTE oil suspensions of high purity spherical iron particles of 2g, 4g, and 8g diameter, at concentrations from 5 ppm to 5,000 ppm. Real contaminated oil samples from Langley Air Force Base aircraft engines and NASA Langley Research Center wind tunnels were also analyzed. The experimental data conform the reliability of XFS as the analytical method of choice for this project. Intrinsic inadequacies of the instrument for precise analytic work at low metal concentrations were identified as being related to the particular x-ray beam definition, system geometry, and flow-cell materials selection. This work supports a proposal for the design, construction and testing of a conceptually new, miniature XFS spectrometer with superior performance, dedicated to on-line, real-time monitoring of lubricating oils in operating engines. Innovative design solutions include focalization of the incident x-ray beam, non-metal sample chamber, and miniaturization of the overall assembly. The instrument would contribute to prevention of catastrophic engine failures. A proposal for two-year funding has been presented to NASA Langley Research Center Internal Operation Group (IOG) Management, to continue the effort begun by this summer's project.

Kelliher, Warren C.↗

Analysis of remote sensing data collected for detection and mapping of oil spills: Reduction and analysis of multi-sensor airborne data of the NASA Wallops oil spill exercise of November 1978

Airborne, remotely sensed data of the NASA Wallops controlled oil spill were corrected, reduced and analysed. Sensor performance comparisons were made by registering data sets from different sensors, which were near-coincident in time and location. Multispectral scanner images were, in turn, overlayed with profiles of correlation between airborne and laboratory-acquired fluorosensor spectra of oil; oil-thickness contours derived (by NASA) from a scanning fluorosensor and also from a two-channel scanning microwave radiometer; and synthetic aperture radar X-HH images. Microwave scatterometer data were correlated with dual-channel (UV and TIR) line scanner images of the oil slick.

Source record↗

Diagnostics of wear in aeronautical systems

The use of appropriate diagnostic tools for aircraft oil wetted components is reviewed, noting that it can reduce direct operating costs through reduced unscheduled maintenance, particularly in helicopter engine and transmission systems where bearing failures are a significant cost factor. Engine and transmission wear modes are described, and diagnostic methods for oil and wet particle analysis, the spectrometric oil analysis program, chip detectors, ferrography, in-line oil monitor and radioactive isotope tagging are discussed, noting that they are effective over a limited range of particle sizes but compliment each other if used in parallel. Fine filtration can potentially increase time between overhauls, but reduces the effectiveness of conventional oil monitoring techniques so that alternative diagnostic techniques must be used. It is concluded that the development of a diagnostic system should be parallel and integral with the development of a mechanical system.

Wedeven, L. D.↗

X-ray fluorescence analysis of wear metals in used lubricating oils

Used oils from several aircraft at NASA's Langley Research Center were analyzed over a three year period using X-ray fluorescence (XRF) and atomic emission spectrometry. The results of both analyses are presented and comparisons are made. Fe and Cu data for oil from four internal combustion engines are provided and XRF and atomic emission spectrometry measurements were found to be in perfect agreement. However, distributions were found in the case of oil from a jet aircraft engine whereby the latter method gave values for total iron concentration in the oil and did not distinguish between suspended particles and oil additives. XRF does not have these particle-size limitations; moreover, it is a faster process. It is concluded that XRF is the preferred method in the construction of a man-portable oil wear analysis instrument.

Maddox, W. E.↗

An Analysis of Abandoned Oil Well Characteristics Affecting Methane Emissions Estimates in the Cherokee Platform in Eastern Oklahoma

Anthropogenic activities increase methane emissions, contributing to greenhouse gas levels and adversely affecting the environment. Abandoned oil and gas wells potentially leak methane, but data are limited. We analyze methane emissions from abandoned wells (n = 179) in the Cherokee Platform in Oklahoma, a previously unaccounted basin, and compare emissions factors (EFs) to those in the Greenhouse Gas Inventory. We compare the contribution of various characteristics to the propensity for leakage. Higher emissions were observed with shallower wells and with unplugged wells. Plugged wells (n = 20) had an average EF of 96 ± 429 g/day and 65 ± 294 g/day for unplugged wells (n = 159). The majority of wells had no detectable leak. We calculated ethane EFs based on geochemical analysis of gas samples, finding higher EFs for unplugged (1.2 ± 5.5 g/day) versus plugged (0.9 ± 4.6 g/day) wells. The data indicate that in addition to the location of abandoned wells, physical characteristics are necessary to consider in estimating methane emissions.

58 GEOSCIENCES↗

Techno-economic analysis of converting oil & gas produced water into valuable resources

Managing produced water from oil and gas wells constitutes a significant portion of the costs of operating a well. Here, in this work, we have designed two different centralized water treatment facilities capable of managing produced water from oil and gas wells in Texas and Louisiana, both of which convert the produced water into the following valuable resources: ten-pound brine and fresh water. The two main designs each use commercially available technology with varying levels of establishment in treating produced water. Both treatment processes remove oil and grease and suspended solids, reduce the divalent ion concentrations, and concentrate the brines to a near-saturation state. The baseline design uses chemical precipitation to remove the divalent ions to meet the reuse specifications, whereas the advanced design uses nanofiltration (NF) membranes to separate divalent ions and uses reverse osmosis (RO) membranes to partially concentrate the brine. Both models use mechanical vapor recompression to concentrate the brine up to NaCl saturation. The baseline process is shown to be cost-effective for low-hardness brines. In the case of high hardness, the chemical precipitation step is cost-prohibitive. We find that NF membranes are a promising alternative to chemical precipitation as a means of separating monovalent and divalent ions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Introducing bioderived solvents for safer and more sustainable 19 F benchtop NMR analysis of pyrolysis oils

The development of increasingly sustainable analytical chemistry techniques is a growing area of research. Detailed knowledge of bio-oil composition is crucial for the wider use of this alternative, sustainable fuel product, whether by guiding and optimising the pyrolysis processes or for indicating appropriate upgrading methods. The oxygen-containing species in the oil are most important to analyse as they are key to the long-term stability and further processing of the oil. A common analytical method is derivatisation, inserting 19 F nuclei only into specific compounds in the sample, so that a sparser NMR spectrum of a subset of the compounds present can be acquired with even a benchtop NMR spectrometer. However, the derivatisation reactions themselves are not benign, with the most commonly used method relying on DMF throughout. While DMF is highly effective in facilitating the derivatisation reaction, it is not only harmful but increasingly restricted in use. By substituting DMF with ethyl lactate, the reaction is rendered safer and more sustainable. The change in solvent does not affect the NMR results, with estimates of total carbonyl content comparable with those produced by titration. The spectra acquired are detailed enough to also allow the quantification of the different carbonyl functional groups present. By switching to ethyl lactate, it is possible to increase the amount of water in the solvent mixture, further reducing the environmental impact, user risks and cost of the analytical method. By replacing harmful solvents with greener alternatives, benchtop NMR analyses of pyrolysis oils are increasingly safer to run, increasingly cheaper to run, and increasingly more accessible to a wide range of different users.

Tang, Bridget [Aston University, Birmingham (Unite↗

Assessment of two neglected effects in the analysis of an oil pumping ring seal

Many factors have been found to affect the performance of a pumping ring seal. In this paper, two effects (elevated reservoir temperature and rod deformation), both heretofore neglected, are assessed through the use of a thermoelastohydrodynamic numerical model of the pumping ring. Elevated reservoir temperatures are found to result in an increase in the amount of lubricant pumped while deformation of the translating rod is shown to cause a reduction in the lubricant pumped.

Keith, T. G.↗