Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational amplifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Ultrastable low-noise current amplifier: A novel device for measuring small electric currents with high accuracy

An ultrastable low-noise current amplifier (ULCA) is presented. The ULCA is a non-cryogenic instrument based on specially designed operational amplifiers and resistor networks. It involves two stages, the first providing a 1000-fold current gain and the second performing a current-to-voltage conversion via an internal 1 MΩ reference resistor or, optionally, an external standard resistor. The ULCA’s transfer coefficient is highly stable versus time, temperature, and current amplitude within the full dynamic range of ±5 nA. The low noise level of 2.4 fA/√Hz helps to keep averaging times short at small input currents. A cryogenic current comparator is used to calibrate both input current gain and output transresistance, providing traceability to the quantum Hall effect. Within one week after calibration, the uncertainty contribution from short-term fluctuations and drift of the transresistance is about 0.1 parts per million (ppm). The long-term drift is typically 5 ppm/yr. A high-accuracy variant is available that shows improved stability of the input gain at the expense of a higher noise level of 7.5 fA/√Hz. The ULCA also allows the traceable generation of small electric currents or the calibration of high-ohmic resistors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Triple probe signal detection electronics for systems lacking a well defined ground

Triple probes have been used to measure plasma parameters of low temperature and edge plasmas, yielding simultaneous measurements of electron temperature, ion density, and floating potential. Unlike standard Langmuir and double probe techniques, there is no requirement to sweep the probe potential relative to the plasma, thus allowing fast time resolution. However, in some plasma systems 'ground' is not well defined with respect to a known ground, may vary strongly in time, or may be at an inconveniently high voltage. The resulting high plasma (or floating) potential requires common mode rejection before the signals can be digitized. A signal detection circuit constructed from inexpensive operational amplifiers and that makes use of a novel floating bias generation configuration is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of an integrated op-amp based chaotic neuron model and observation of its chaotic dynamics

This paper presents a fully integrated circuit implementation of an operational amplifier (op-amp) based chaotic neuron model with a bipolar output function, experimental measurements, and analyses of its chaotic behavior. The proposed chaotic neuron model integrated circuit consists of several op-amps, sample and hold circuits, a nonlinear function block for chaotic signal generation, a clock generator, a nonlinear output function, etc. Based on the HSPICE (circuit program) simulation results, approximated empirical equations for analyses were formulated. Then, the chaotic dynamical responses such as bifurcation diagrams, time series, and Lyapunov exponent were calculated using these empirical equations. In addition, we performed simulations about two chaotic neuron systems with four synapses to confirm neural network connections and got normal behavior of the chaotic neuron such as internal state bifurcation diagram according to the synaptic weight variation. The proposed circuit was fabricated using a 0.8-{mu}m single poly complementary metal-oxide semiconductor technology. Measurements of the fabricated single chaotic neuron with {+-}2.5 V power supplies and a 10 kHz sampling clock frequency were carried out and compared with the simulated results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nd.sup.3+fiber laser and amplifier

An Nd.sup.3+ optical fiber laser and amplifier operating in the wavelength range from 1300 to 1450 nm is described. The fiber includes a rare earth doped optical amplifier or laser operating within this wavelength band is based upon an optical fiber that guides light in this wavelength band. The waveguide structure attenuates light in the wavelength range from 850 nm to 950 nm and from 1050 nm to 1150 nm.

Dawson, Jay W.↗

Design and validation of a high-voltage levitation circuit for electrostatic accelerometers

A simple high-voltage circuit with a voltage range of 0 to 900 V and an open-loop bandwidth of 11 kHz is realized by using an operational amplifier and a MOSFET combination. The circuit is used for the levitation of a test mass of 71 g, suspended below the top-electrodes with a gap distance of 57 μm, so that the performance of an electrostatic accelerometer can be tested on the ground. The translation noise of the accelerometer, limited by seismic noise, is about 4 × 10{sup −8} m/s{sup 2}/Hz{sup 1/2} at 0.1 Hz, while the high-voltage coupling noise is one-order of magnitude lower.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated circuit physically unclonable function

An integrated circuit (IC) based physically unclonable function (PUF) that comprises a common source amplifier for generating PUF output voltages, a unity gain, negative feedback operational amplifier for generating bias voltages, a voltage regulator and a bit exclusion circuit that excludes unstable PUF bits. Compensation circuitry built into the IC-PUF provides a high power supply rejection ratio and enables highly reliable operation of the IC-PUF across varying input voltages and operating temperatures. The IC-PUF generates a uniformly random output bit stream by taking advantage of process variations that are inherent to the fabrication of (metal-oxide semiconductor) MOS transistors.

42 ENGINEERING↗

Diode amplifier of modulated optical beam power

Analytical relations are obtained between characteristics of modulated light at the output and input of an optical diode power amplifier operating in the highly saturated gain regime. It is shown that a diode amplifier may act as an amplitude-to-phase modulation converter with a rather large bandwidth (∼10 GHz). The low sensitivity of the output power of the amplifier to the input beam power and its high energy efficiency allow it to be used as a building block of a high-power multielement laser system with coherent summation of a large number of optical beams. (lasers)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlinear fibre-optic devices pumped by semiconductor disk lasers

Semiconductor disk lasers offer a unique combination of characteristics that are particularly attractive for pumping Raman lasers and amplifiers. The advantages of disk lasers include a low relative noise intensity (-150 dB Hz{sup -1}), scalable (on the order of several watts) output power, and nearly diffraction-limited beam quality resulting in a high ({approx}70 % - 90 %) coupling efficiency into a single-mode fibre. Using this technology, low-noise fibre Raman amplifiers operating at 1.3 {mu}m in co-propagation configuration are developed. A hybrid Raman-bismuth doped fibre amplifier is proposed to further increase the pump conversion efficiency. The possibility of fabricating mode-locked picosecond fibre lasers operating under both normal and anomalous dispersion is shown experimentally. We demonstrate the operation of 1.38-{mu}m and 1.6-{mu}m passively mode-locked Raman fibre lasers pumped by 1.29-{mu}m and 1.48-{mu}m semiconductor disk lasers and producing 1.97- and 2.7-ps pulses, respectively. Using a picosecond semiconductor disk laser amplified with an ytterbium-erbium fibre amplifier, the supercontinuum generation spanning from 1.35 {mu}m to 2 {mu}m is achieved with an average power of 3.5 W. (invited paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High Bandwidth Differential Amplifier for Shock Experiments

We developed a high bandwidth differential amplifier for gas gun shock experiments/applications. The circuit has a bandwidth > 1 GHz, and is capable of measuring signals of ≤1.5 V with a common mode rejection of 250 V. Conductivity measurements of gas gun targets are measured by flowing high currents through the targets. The voltage is measured across the target using a technique similar to a four-point probe. Because of the design of the current source and load, the target voltage is approximately 250 V relative to ground. Since the expected voltage change in the target is < 1 V, the differential amplifier must have a large common mode rejection. High pass filters suppress internal ringing of operational amplifiers. Results of bench tests are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

National Ignition Facility: Shot Operations Plan

This document identifies the policies and general procedures necessary to perform and support routine shot operations in the NIF Facility. Shot Operations are defined as those activities directly related to or supporting the operation of the NIF Main Laser System, Precision Diagnostic System (PDS), Target Chamber (TC), and associated systems located on the NIF. Operations include delivery of low-power laser light through to the firing of the main laser amplifiers, operation of the beampath and associated utilities, target positioners and diagnostics, and the various computer control systems. Construction and maintenance activities are not covered here, except as they interface to ongoing operations. This document, in conjunction with the NIF Operations Management Plan and NIF Maintenance Plan, satisfies the requirements for a Conduct of Operations.

42 ENGINEERING↗

Flying focus and its application to plasma-based laser amplifiers

Combining a chirped laser pulse with a chromatic lens yields a flying focus—a laser focus that moves dynamically in time. This provides control over the propagation of the peak laser intensity within an extended focal region that can be many times larger than the system’s Rayleigh length. Any velocity is achievable, including backward relative to the laser propagation direction. Previous simulation results have shown that a laser beam with a flying focus can create a counter-propagating ionization wave and subsequently pump a frequency-downshifted laser via the stimulated Raman scattering instability. Compared to a conventional Raman amplification scheme, several advantages were highlighted, including improved temperature control, plasma uniformity, and precursor growth mitigation. Here, we extend those results to demonstrate additional benefits: (1) the flying focus makes it possible for an unseeded Raman amplifier to produce a short, high-intensity beam; and (2) the flying focus minimizes collisional absorption of the pump, facilitating amplifier operation at higher plasma densities. Preliminary experiments have laid the groundwork for a high-performance plasma-based laser amplifier. The focal spot dynamics were initially confirmed at low intensity. It was subsequently demonstrated that ionization waves of arbitrary velocity can be produced at higher intensity. Here, we show a counter-propagating ionization front moving at approximately the speed of light—the optimal result for a Raman amplifier.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Power balancing a multibeam laser

Multibeam lasers often require an output beam balance that specifies the degree of simultaneity of the laser output energy, instantaneous power, or instantaneous irradiance (power per unit area). Here, this work describes the general problem of balancing a multibeam laser. Specific techniques used to balance the output power of the 60-beam pulsed OMEGA Laser System are discussed along with a measured reduction of beam-to-beam imbalance. In particular, the square-pulse distortion induced by a simple saturating amplifier operating with its output at some fraction of its saturation fluence is derived, and a method to exchange gain between saturated amplifiers in a single beam that have different saturation fluences to adjust balance is described.

47 OTHER INSTRUMENTATION↗

Power balancing the multibeam OMEGA laser

Multibeam lasers often require an output beam balance that specifies the degree of simultaneity of laser output energy, instantaneous power, or instantaneous irradiance (power per unit area). In this work the general problem of balancing a multibeam laser is described. Specific techniques used to balance the output power of the 60-beam pulsed OMEGA Laser System are discussed along with a measured reduction of beam-to-beam imbalance. In particular, the square-pulse distortion induced by a simple saturating amplifier operating with its output at some fraction of its saturation fluence is derived, and a novel method of exchanging gain between saturated amplifiers in a single beam that have different saturation fluences to adjust balance is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of Pump-Induced Temporal Contrast Degradation in Optical Parametric Chirped-Pulse Amplification

The pump-induced degradation of the temporal contrast of laser pulses amplified by optical parametric chirped-pulse amplification (OPCPA) is studied analytically. In OPCPA systems, the temporal fluctuations of the pump pulse are coupled to the spectrum of the chirped signal by the instantaneous parametric gain and lead to a reduction in the temporal contrast of the recompressed amplified signal. The intensity and shape of the induced temporal pedestal depend on the pump fluctuations and the parametric amplifier operating regime. General equations describing the contrast degradation are derived and applied to the case of sinusoidal pump-intensity modulation and pump amplified spontaneous emission. The reduction of the contrast in the amplified pulse is quantified analytically and via simulations for an OPCPA system.

42 ENGINEERING↗

Broadband calibrated scattering parameters characterization of a superconducting quantum interference device amplifier

In this work, we characterize the 2-port scattering parameters of a superconducting quantum interference device amplifier at {approx}20 mK over several gigahertz of bandwidth. The measurement reference plane is positioned on a 6.25 {Omega} microstrip line situated directly at the input and output of the device by means of a thru-reflect-line cryogenic calibration procedure. From the scattering parameters, we derive the device available power gain, isolation, and input impedance over the 2-8 GHz range. This measurement methodology provides a path towards designing wide-band matching circuits for low impedance superconducting amplifiers operating at dilution refrigerator temperatures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modelling of the laser amplification process with allowance for the effect of the temperature distribution in an Yb : YAG gain element on the thermophysical and lasing characteristics of the medium

A time-dependent three-dimensional model for the laser amplification process has been constructed with allowance for the effect of the temperature distribution on the thermophysical and lasing characteristics of gain media. We have performed numerical modelling of the laser amplification process in the gain elements of a two-stage subjoule-level cryogenic laser amplifier operating at a pulse repetition rate of up to 1 kHz. It has been shown that taking into account the temperature distribution is of critical importance in calculation of cryogenically cooled laser amplifiers pumped with high-power diodes. We have found optimal diode pump parameters at which the maximum achievable pulse energy at the amplifier output can reach 300 and 570 mJ at pulse repetition rates of 1000 and 500 Hz, respectively. (extreme light fields and their interaction with matter)

42 ENGINEERING↗

Three-Wave Mixing Kinetic Inductance Traveling-Wave Amplifier with Near-Quantum-Limited Noise Performance

We present a theoretical model and experimental characterization of a microwave kinetic inductance traveling-wave (KIT) amplifier, whose noise performance, measured by a shot-noise tunnel junction (SNTJ), approaches the quantum limit. Biased with a dc current, this amplifier operates in a three-wave mixing fashion, thereby reducing by several orders of magnitude the power of the microwave pump tone and associated parasitic heating compared to conventional four-wave mixing KIT amplifier devices. It consists of a 50 Ω artificial transmission line whose dispersion allows for a controlled amplification bandwidth. We measure $16.5^{+1}_{–1.3}$ dB of gain across a 2 GHz bandwidth with an input 1 dB compression power of –63 dBm, in qualitative agreement with theory. Using a theoretical framework that accounts for the SNTJ-generated noise entering both the signal and idler ports of the KIT amplifier, we measure the system-added noise of an amplification chain that integrates the KIT amplifier as the first amplifier. This system-added noise, 3.1 ± 0.6 quanta (equivalent to 0.66 ± 0.15 K) between 3.5 and 5.5 GHz, is the one that a device replacing the SNTJ in that chain would see. This KIT amplifier is therefore suitable to read large arrays of microwave kinetic inductance detectors and promising for multiplexed superconducting qubit readout.

42 ENGINEERING↗